Getting Started Guide
Page 7
... software, system updates, and system components that shipped with the requirements of the official Mexican standards (NOM): Importer: Dell Inc. NOM Information The following information is available online at support.dell.com/manuals. • The rack documentation included with your rack...and managing your system. Paseo de la Reforma 2620 -11º Piso Col. Dell offers comprehensive hardware training and certification. de C.V. Obtaining Technical Assistance If you purchased with 1100 W DC power supply unit) 7 Lomas Altas 11950 México, D.F. de México,...
... software, system updates, and system components that shipped with the requirements of the official Mexican standards (NOM): Importer: Dell Inc. NOM Information The following information is available online at support.dell.com/manuals. • The rack documentation included with your rack...and managing your system. Paseo de la Reforma 2620 -11º Piso Col. Dell offers comprehensive hardware training and certification. de C.V. Obtaining Technical Assistance If you purchased with 1100 W DC power supply unit) 7 Lomas Altas 11950 México, D.F. de México,...
Getting Started Guide
Page 8
... dissipation 1908 BTU/hr maximum (495 W power NOTE: Heat dissipation is also designed to be connected to IT power systems with a phase to support.dell.com. NOTE: The following specifications are only those required by law to ship with your system, ...(AC power supply unit) 12 A - 6.5 A (X 2) (with 1100 W AC power supply unit) 10 A - 5 A (X 2) (with 750 W AC power supply unit) 6.5 A - 3 A (X 2) (with 495 W AC power supply unit) 32 A (X 2) (with 1100 W DC power supply unit) Technical Specifications NOTE: The following specifications apply to both PowerEdge R720 and PowerEdge R720xd ...
... dissipation 1908 BTU/hr maximum (495 W power NOTE: Heat dissipation is also designed to be connected to IT power systems with a phase to support.dell.com. NOTE: The following specifications are only those required by law to ship with your system, ...(AC power supply unit) 12 A - 6.5 A (X 2) (with 1100 W AC power supply unit) 10 A - 5 A (X 2) (with 750 W AC power supply unit) 6.5 A - 3 A (X 2) (with 495 W AC power supply unit) 32 A (X 2) (with 1100 W DC power supply unit) Technical Specifications NOTE: The following specifications apply to both PowerEdge R720 and PowerEdge R720xd ...
Owner's Manual
Page 14
... without any error exists (for example, a failed fan or hard drive) Corrective Action None required. Run the appropriate Online Diagnostics test. If it into a working power source and press the power button. Option Description MAC Displays the MAC addresses for the system. The display format can be...system messages for the specific issue. The diagnostic indicators on PowerEdge R720xd. If the hard drives are lit when the system is on or in standby, and any video output. See Getting Help. Power Displays the power output of the system in the Set home submenu of ...
... without any error exists (for example, a failed fan or hard drive) Corrective Action None required. Run the appropriate Online Diagnostics test. If it into a working power source and press the power button. Option Description MAC Displays the MAC addresses for the system. The display format can be...system messages for the specific issue. The diagnostic indicators on PowerEdge R720xd. If the hard drives are lit when the system is on or in standby, and any video output. See Getting Help. Power Displays the power output of the system in the Set home submenu of ...
Owner's Manual
Page 15
... Corrective Action Ensure that none of range, or a failed power supply or voltage regulator). Corrective Action Restart the system. Update any required drivers for the location of range or fan failure). Re-seat the power supply by removing and reinstalling it. See Getting Help. Re...System cover, cooling shroud, EMI filler panel, memory- If the problem persists, see Getting Help. 15 Corrective Action LED on the power supply. If the problem persists, see Getting Help. If the problem persists, see Getting Help. Memory indicator Condition The indicator blinks ...
... Corrective Action Ensure that none of range, or a failed power supply or voltage regulator). Corrective Action Restart the system. Update any required drivers for the location of range or fan failure). Re-seat the power supply by removing and reinstalling it. See Getting Help. Re...System cover, cooling shroud, EMI filler panel, memory- If the problem persists, see Getting Help. 15 Corrective Action LED on the power supply. If the problem persists, see Getting Help. If the problem persists, see Getting Help. Memory indicator Condition The indicator blinks ...
Owner's Manual
Page 20
... your rack solution describes how to install your system into a rack, if required. • Any media that ships with your system that provides documentation and tools for updates on support.dell.com/manuals and read the updates first because they can output different wattages, ...Started Guide provides an overview of efficiency, feature set, health status, and supported voltage). Warranty information may be of the other installed power supply. NOTE: Always check for configuring and managing your system, including those pertaining to the operating system, system management software, system...
... your rack solution describes how to install your system into a rack, if required. • Any media that ships with your system that provides documentation and tools for updates on support.dell.com/manuals and read the updates first because they can output different wattages, ...Started Guide provides an overview of efficiency, feature set, health status, and supported voltage). Warranty information may be of the other installed power supply. NOTE: Always check for configuring and managing your system, including those pertaining to the operating system, system management software, system...
Owner's Manual
Page 29
...Enabled with Pre-boot Measurements or On without Pre-boot Measurements. For environments that do not require local BIOS updates, it is set this option. Power Button NMI Button AC Power Recovery Allows you to Auto. By default, the Memory Operating Voltage option is set to ...Power Recovery option is set to lock the system password. Password Status Allows you to Last. 29 BIOS Update Control Allows you to Off. NOTE: BIOS updates using either On with Pre-boot measurements. By default, the Intel TXT option is set to update the BIOS using Dell...
...Enabled with Pre-boot Measurements or On without Pre-boot Measurements. For environments that do not require local BIOS updates, it is set this option. Power Button NMI Button AC Power Recovery Allows you to Auto. By default, the Memory Operating Voltage option is set to ...Power Recovery option is set to lock the system password. Password Status Allows you to Last. 29 BIOS Update Control Allows you to Off. NOTE: BIOS updates using either On with Pre-boot measurements. By default, the Intel TXT option is set to update the BIOS using Dell...
Owner's Manual
Page 34
Embedded System Management The Dell Lifecycle Controller provides advanced embedded systems management throughout the server's lifecycle. The Lifecycle Controller can be started during Power-on Self-test (POST). 3. Press during the boot sequence and can enable or disable various iDRAC parameters ... 1. UEFI Boot Menu Menu Item Description Select UEFI Boot Option Displays the list of the features on the iDRAC Settings Utility requires the iDRAC7 Enterprise License upgrade. NOTE: Accessing some of available UEFI boot options (marked with asterisks), select the boot option ...
Embedded System Management The Dell Lifecycle Controller provides advanced embedded systems management throughout the server's lifecycle. The Lifecycle Controller can be started during Power-on Self-test (POST). 3. Press during the boot sequence and can enable or disable various iDRAC parameters ... 1. UEFI Boot Menu Menu Item Description Select UEFI Boot Option Displays the list of the features on the iDRAC Settings Utility requires the iDRAC7 Enterprise License upgrade. NOTE: Accessing some of available UEFI boot options (marked with asterisks), select the boot option ...
Owner's Manual
Page 35
... wire NOTE: Use alpha wire part number 3080 or equivalent (65/30 stranding). Lift the release latch next to ground Following tools are required for assembling cables for a DC power supply unit (PSU), when available: • AMP 90871-1 hand-crimping tool or equivalent • Wire-stripper pliers capable of the bezel away...
... wire NOTE: Use alpha wire part number 3080 or equivalent (65/30 stranding). Lift the release latch next to ground Following tools are required for assembling cables for a DC power supply unit (PSU), when available: • AMP 90871-1 hand-crimping tool or equivalent • Wire-stripper pliers capable of the bezel away...
Owner's Manual
Page 66
...attached peripherals, and disconnect the system from the expansion-card riser. 8. Damage due to the power connector on the cooling shroud. 9. Open the system. 3. NOTE: When installing a GPU card on riser 2... or riser 3 (default), connect the GPU card power cable to servicing that the connector on the expansion card aligns with the product. Read and... perform troubleshooting and simple repairs as authorized in the documentation for the card as directed by Dell is fully seated. 7. The brackets also keep dust and dirt out of the system. Reinstall...
...attached peripherals, and disconnect the system from the expansion-card riser. 8. Damage due to the power connector on the cooling shroud. 9. Open the system. 3. NOTE: When installing a GPU card on riser 2... or riser 3 (default), connect the GPU card power cable to servicing that the connector on the expansion card aligns with the product. Read and... perform troubleshooting and simple repairs as authorized in the documentation for the card as directed by Dell is fully seated. 7. The brackets also keep dust and dirt out of the system. Reinstall...
Owner's Manual
Page 71
Close the system. 7. expansion-card slot 7 3. power connector (for the card as described in the system. ...expansion card riser. 2. Install any attached peripherals. 6. For more information, see the iDRAC7 User's Guide at support.dell.com/ manuals. Locate the vFlash media slot on the riser. 5. If applicable, reinstall the expansion card(s) into ...and a custom deployment environment that came with the connector and the riser guide pin on , including any device drivers required for GPU cards) 4. Close the system. 5. SD vFlash Card A vFlash SD card is not covered by a...
Close the system. 7. expansion-card slot 7 3. power connector (for the card as described in the system. ...expansion card riser. 2. Install any attached peripherals. 6. For more information, see the iDRAC7 User's Guide at support.dell.com/ manuals. Locate the vFlash media slot on the riser. 5. If applicable, reinstall the expansion card(s) into ...and a custom deployment environment that came with the connector and the riser guide pin on , including any device drivers required for GPU cards) 4. Close the system. 5. SD vFlash Card A vFlash SD card is not covered by a...
Owner's Manual
Page 85
... sleep state. If the output voltage of the active power supply. The active power supply can configure the Hot Spare feature using the iDRAC settings. CAUTION: The system requires one power supply at support.dell.com/manuals. Disconnect the power cable from the strap. 2. Damage due to remove and... remove the cables from the power source and the power supply you intend to servicing that is not covered...
... sleep state. If the output voltage of the active power supply. The active power supply can configure the Hot Spare feature using the iDRAC settings. CAUTION: The system requires one power supply at support.dell.com/manuals. Disconnect the power cable from the strap. 2. Damage due to remove and... remove the cables from the power source and the power supply you intend to servicing that is not covered...
Owner's Manual
Page 87
...-3 or equivalent), crimp the ring-tongue terminal (Jeeson Terminals Inc., R5-4SA or equivalent) to DC power or installing grounds yourself. Input Requirements • Supply voltage: -(48-60) V DC • Current consumption: 32 A (maximum) Kit Contents • Dell part number 6RYJ9 terminal block or equivalent (1) • #6-32 nut equipped with a yellow stripe, stranded...
...-3 or equivalent), crimp the ring-tongue terminal (Jeeson Terminals Inc., R5-4SA or equivalent) to DC power or installing grounds yourself. Input Requirements • Supply voltage: -(48-60) V DC • Current consumption: 32 A (maximum) Kit Contents • Dell part number 6RYJ9 terminal block or equivalent (1) • #6-32 nut equipped with a yellow stripe, stranded...
Owner's Manual
Page 89
... national codes and practices. captive screws (2) 4. Disconnect the safety ground wire. 3. CAUTION: The system requires one power supply at a time in a system that is not covered by Dell is powered on. NOTE: You may have to unlatch and lift the optional cable management arm if it interferes with... the product. Assembling the DC Input Power Wires 1. wire RTN 7. For information about the cable management arm, see the...
... national codes and practices. captive screws (2) 4. Disconnect the safety ground wire. 3. CAUTION: The system requires one power supply at a time in a system that is not covered by Dell is powered on. NOTE: You may have to unlatch and lift the optional cable management arm if it interferes with... the product. Assembling the DC Input Power Wires 1. wire RTN 7. For information about the cable management arm, see the...
Owner's Manual
Page 138
... • Do not perform a cold startup below 5 °C. • The operating temperature specified is for specific system configurations, see dell.com/environmental_datasheets. NOTE: When operating in the expanded temperature range, ambient temperature warnings may be reported on the LCD and in the expanded ...Redundant power supplies are required. • Non Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported. 138 De-rate maximum allowable dry bulb temperature at 10% to 85% RH with 26 °C max dew point. NOTE: When using PowerEdge R720 with...
... • Do not perform a cold startup below 5 °C. • The operating temperature specified is for specific system configurations, see dell.com/environmental_datasheets. NOTE: When operating in the expanded temperature range, ambient temperature warnings may be reported on the LCD and in the expanded ...Redundant power supplies are required. • Non Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported. 138 De-rate maximum allowable dry bulb temperature at 10% to 85% RH with 26 °C max dew point. NOTE: When using PowerEdge R720 with...
Owner's Manual
Page 149
... . If the issue persists, see Getting Help. Details System BIOS detected memory, but is detected, but was removed. LCD Message Power input for PSU is within the operating requirements for the power supply. Details The controller detected that the drive was unable to supported system memory configurations. Check memory devices. PSU0001 Message LCD...
... . If the issue persists, see Getting Help. Details System BIOS detected memory, but is detected, but was removed. LCD Message Power input for PSU is within the operating requirements for the power supply. Details The controller detected that the drive was unable to supported system memory configurations. Check memory devices. PSU0001 Message LCD...
Owner's Manual
Page 155
Warning messages usually interrupt the task and require you run diagnostic tests on the hard drive. NOTE: Warning messages are generated by typing y (yes) or n (no). Diagnostic Messages The system diagnostic ...management software generates alert messages for more information about system diagnostics. Alert messages include information, status, warning, and failure messages for drive, temperature, fan, and power conditions. For more information, see the documentation that you to respond before the system continues a task. Warning Messages A warning message alerts you to a possible...
Warning messages usually interrupt the task and require you run diagnostic tests on the hard drive. NOTE: Warning messages are generated by typing y (yes) or n (no). Diagnostic Messages The system diagnostic ...management software generates alert messages for more information about system diagnostics. Alert messages include information, status, warning, and failure messages for drive, temperature, fan, and power conditions. For more information, see the documentation that you to respond before the system continues a task. Warning Messages A warning message alerts you to a possible...
Technical Guide
Page 7
...-less. Next generation PERC options The R720 and R720xd support new PERC controller cards with Lifecycle Controller Internal GPU support Advanced power management Dell Express Flash PCIe solid-state drives provide fast performance without requiring processor resources or capturing DRAM. PERC ... Express Flash drives. See the Storage section for details. The R720 and R720xd support advanced power monitoring and power capping tools that enables you to customize your LAN port combinations from your Dell PowerEdge servers. See the Memory section for details. See the Networking...
...-less. Next generation PERC options The R720 and R720xd support new PERC controller cards with Lifecycle Controller Internal GPU support Advanced power management Dell Express Flash PCIe solid-state drives provide fast performance without requiring processor resources or capturing DRAM. PERC ... Express Flash drives. See the Storage section for details. The R720 and R720xd support advanced power monitoring and power capping tools that enables you to customize your LAN port combinations from your Dell PowerEdge servers. See the Memory section for details. See the Networking...
Technical Guide
Page 24
... once a correctable error is stored in rapid, accurate diagnosis of faults which require service. Memory RAID is a method of keeping a duplicate (secondary or mirrored...prevent DIMMs from causing an uncorrectable failure. This feature helps to optimize power/performance and can also be a result from this selectable platform profile ...PowerEdge R720 and R720xd Technical Guide This feature provides the ability to identify a specific failing DIMM channel pair, thereby enabling the user to errors. For information on memory mirroring and sparing configurations, see the Dell PowerEdge R720...
... once a correctable error is stored in rapid, accurate diagnosis of faults which require service. Memory RAID is a method of keeping a duplicate (secondary or mirrored...prevent DIMMs from causing an uncorrectable failure. This feature helps to optimize power/performance and can also be a result from this selectable platform profile ...PowerEdge R720 and R720xd Technical Guide This feature provides the ability to identify a specific failing DIMM channel pair, thereby enabling the user to errors. For information on memory mirroring and sparing configurations, see the Dell PowerEdge R720...
Technical Guide
Page 38
... 6 x 300GB 2 x SAS (10K) 750W 8 x 8GB H710, 1 x GbE Stressed4 4.5 26 None NIC Configuration (23 ± 2°C CPUs ambient) Hard drives Power supply unit PCI Memory card/HDD controller Operating mode LWA-UL1 LpA2 (bels) (dBA) Prominent tones3 Minimum 1 1 x 250GB 1 x SATA (7.2k) 495W 1 x 8GB 1...io® cards require greater airflow for the R720 and R720xd. UL is the upper limit sound power levels (LwA) calculated per section 4.3 of more information on Dell's acoustical design, see the Dell Enterprise Acoustics white paper. 38 PowerEdge R720 and R720xd Technical Guide...
... 6 x 300GB 2 x SAS (10K) 750W 8 x 8GB H710, 1 x GbE Stressed4 4.5 26 None NIC Configuration (23 ± 2°C CPUs ambient) Hard drives Power supply unit PCI Memory card/HDD controller Operating mode LWA-UL1 LpA2 (bels) (dBA) Prominent tones3 Minimum 1 1 x 250GB 1 x SATA (7.2k) 495W 1 x 8GB 1...io® cards require greater airflow for the R720 and R720xd. UL is the upper limit sound power levels (LwA) calculated per section 4.3 of more information on Dell's acoustical design, see the Dell Enterprise Acoustics white paper. 38 PowerEdge R720 and R720xd Technical Guide...
Technical Guide
Page 45
...power monitoring and capping (requires iDRAC7 Enterprise) To obtain a software license key for better performance; free 30-day trial versions are available; These embedded features improve all aspects of deploying, updating, monitoring, and maintaining your Dell PowerEdge servers. The Dell OpenManage™ systems management portfolio includes powerful... hardware and software management tools and consoles. In addition to simplify license management 45 PowerEdge R720 and ...
...power monitoring and capping (requires iDRAC7 Enterprise) To obtain a software license key for better performance; free 30-day trial versions are available; These embedded features improve all aspects of deploying, updating, monitoring, and maintaining your Dell PowerEdge servers. The Dell OpenManage™ systems management portfolio includes powerful... hardware and software management tools and consoles. In addition to simplify license management 45 PowerEdge R720 and ...