Owner's Manual
Page 5
Removing A Cooling Fan...56 Installing A Cooling Fan...57 Removing The Cooling-Fan Assembly...57 Installing The Cooling-Fan Assembly...58 Internal USB Memory Key (Optional)...59 Replacing The Internal USB Key...59 PCIe Card Holder...59 Removing The PCIe Card Holder...60 Installing The PCIe Card Holder...61 Opening And Closing The PCIe...
Removing A Cooling Fan...56 Installing A Cooling Fan...57 Removing The Cooling-Fan Assembly...57 Installing The Cooling-Fan Assembly...58 Internal USB Memory Key (Optional)...59 Replacing The Internal USB Key...59 PCIe Card Holder...59 Removing The PCIe Card Holder...60 Installing The PCIe Card Holder...61 Opening And Closing The PCIe...
Owner's Manual
Page 6
... Hard-Drive Backplane (Back 108 Control Panel...109 Removing The Control Panel (PowerEdge R720 109 Installing The Control Panel (PowerEdge R720 111 Removing The Control Panel (PowerEdge R720xd 111 Installing The Control Panel (PowerEdge R720xd 112 Removing The I/O Panel (PowerEdge R720xd 113 Installing The I/O Panel (PowerEdge R720xd 114 System Board...114 Removing The System Board...114 Installing The...
... Hard-Drive Backplane (Back 108 Control Panel...109 Removing The Control Panel (PowerEdge R720 109 Installing The Control Panel (PowerEdge R720 111 Removing The Control Panel (PowerEdge R720xd 111 Installing The Control Panel (PowerEdge R720xd 112 Removing The I/O Panel (PowerEdge R720xd 113 Installing The I/O Panel (PowerEdge R720xd 114 System Board...114 Removing The System Board...114 Installing The...
Owner's Manual
Page 10
... The LCD lights amber when the system needs attention, and the LCD panel displays an error code followed by descriptive text. The ports are USB 2.0-compliant. Item Indicator, Button, or Icon Description Connector the front and the system status indicator on the back flashes until one of whether the... lights amber regardless of the buttons is turned on as Service Tag, NIC, MAC address and so on or off . NOTE: In systems supporting Dell PowerEdge Express Flash devices (PCIe SSDs), hard-drive slots 0 through 3 in F2 iDRAC setup) press and hold the system ID button for more than ...
... The LCD lights amber when the system needs attention, and the LCD panel displays an error code followed by descriptive text. The ports are USB 2.0-compliant. Item Indicator, Button, or Icon Description Connector the front and the system status indicator on the back flashes until one of whether the... lights amber regardless of the buttons is turned on as Service Tag, NIC, MAC address and so on or off . NOTE: In systems supporting Dell PowerEdge Express Flash devices (PCIe SSDs), hard-drive slots 0 through 3 in F2 iDRAC setup) press and hold the system ID button for more than ...
Owner's Manual
Page 12
A slide-out label panel which allows you to connect USB devices to the system. LCD Panel Features NOTE: The LCD panel is present only on as Service Tag, NIC, MAC address, and so on PowerEdge R720. LCD Panel Features Item 1 2 3 Button Left Select Right 12 Description Moves the ... drive systems Up to twenty-four 2.5 inch hotswappable hard drives. 6 Video connector Allows you to connect a VGA display to the system. 7 USB connector 8 Information tag Allows you to record system information such as per your need. The system's LCD panel provides system information and status and ...
A slide-out label panel which allows you to connect USB devices to the system. LCD Panel Features NOTE: The LCD panel is present only on as Service Tag, NIC, MAC address, and so on PowerEdge R720. LCD Panel Features Item 1 2 3 Button Left Select Right 12 Description Moves the ... drive systems Up to twenty-four 2.5 inch hotswappable hard drives. 6 Video connector Allows you to connect a VGA display to the system. 7 USB connector 8 Information tag Allows you to record system information such as per your need. The system's LCD panel provides system information and status and ...
Owner's Manual
Page 17
PowerEdge R720 PowerEdge R720xd When one of these buttons is pressed, the system status indicator on the back flashes until one of these buttons is pressed again. 2 System ... connector 3 iDRAC7 Enterprise port Press to toggle the system ID on your system. 4 PCIe expansion card slots low-profile (3) 5 Serial connector Allows you to connect USB devices to enter BIOS progress mode. Connects the optional system status indicator assembly through the optional cable management arm. The ports are...
PowerEdge R720 PowerEdge R720xd When one of these buttons is pressed, the system status indicator on the back flashes until one of these buttons is pressed again. 2 System ... connector 3 iDRAC7 Enterprise port Press to toggle the system ID on your system. 4 PCIe expansion card slots low-profile (3) 5 Serial connector Allows you to connect USB devices to enter BIOS progress mode. Connects the optional system status indicator assembly through the optional cable management arm. The ports are...
Owner's Manual
Page 26
... is enabled only if the boot mode is not installed in the same boot mode. Integrated Devices Screen Menu Item Integrated RAID Controller User Accessible USB Ports Description Allows you to enable or disable UEFI Boot options. By default, Port B is set to SATA port D. CAUTION: Switching the...to Enabled. By default, the Integrated RAID Controller option is set to UEFI disables BIOS Boot Settings menu. By default, the User Accessible USB Ports option is BIOS. Auto enables BIOS support for the device attached to All Ports On. 26 Allows you can set to Auto. Allows...
... is enabled only if the boot mode is not installed in the same boot mode. Integrated Devices Screen Menu Item Integrated RAID Controller User Accessible USB Ports Description Allows you to enable or disable UEFI Boot options. By default, Port B is set to SATA port D. CAUTION: Switching the...to Enabled. By default, the Integrated RAID Controller option is set to UEFI disables BIOS Boot Settings menu. By default, the User Accessible USB Ports option is BIOS. Auto enables BIOS support for the device attached to All Ports On. 26 Allows you can set to Auto. Allows...
Owner's Manual
Page 27
Menu Item Internal USB Port Internal SD Card Port Description Allows you to On. By default, Internal SD Card Port option is written on... set to On without Console Redirection. NOTE: This option is displayed only if IDSDM is set to enable or disable the internal USB port. Embedded Video Controller Allows you to enable or disable the Embedded Video Controller. Slot Disablement Allows you to enable or disable available...CAUTION: Slot disablement must be enabled and the port address used for Serial Over LAN (SOL). By default, the Internal USB Port option is Enabled.
Menu Item Internal USB Port Internal SD Card Port Description Allows you to On. By default, Internal SD Card Port option is written on... set to On without Console Redirection. NOTE: This option is displayed only if IDSDM is set to enable or disable the internal USB port. Embedded Video Controller Allows you to enable or disable the Embedded Video Controller. Slot Disablement Allows you to enable or disable available...CAUTION: Slot disablement must be enabled and the port address used for Serial Over LAN (SOL). By default, the Internal USB Port option is Enabled.
Owner's Manual
Page 59
... sequence in the Integrated Devices screen of the System Setup. To boot from the electrical outlet and peripherals. 2. Replacing The Internal USB Key CAUTION: Many repairs may only be used as directed by the online or telephone service and support team. Reconnect the system ...to servicing that is not authorized by Dell is detected by the system. Replacing the Internal USB Key 1. USB memory key PCIe Card Holder 59 Open the system. 3. To locate the USB connector (J_USB_INT), see System Board Connectors. Figure 27. Read and follow...
... sequence in the Integrated Devices screen of the System Setup. To boot from the electrical outlet and peripherals. 2. Replacing The Internal USB Key CAUTION: Many repairs may only be used as directed by the online or telephone service and support team. Reconnect the system ...to servicing that is not authorized by Dell is detected by the system. Replacing the Internal USB Key 1. USB memory key PCIe Card Holder 59 Open the system. 3. To locate the USB connector (J_USB_INT), see System Board Connectors. Figure 27. Read and follow...
Owner's Manual
Page 71
...covered by the online or telephone service and support team. Installing Expansion-Card Risers CAUTION: Many repairs may only be done by Dell is fully seated in the connector. 4. Reconnect the system to its electrical outlet and turn the system on , including any...and follow the safety instructions that is not authorized by a certified service technician. It emulates USB device(s). Install any attached peripherals. 6. For more information, see the iDRAC7 User's Guide at support.dell.com/ manuals. Replacing An SD vFlash Card 1. Identifying Connectors on the riser. 5. Damage...
...covered by the online or telephone service and support team. Installing Expansion-Card Risers CAUTION: Many repairs may only be done by Dell is fully seated in the connector. 4. Reconnect the system to its electrical outlet and turn the system on , including any...and follow the safety instructions that is not authorized by a certified service technician. It emulates USB device(s). Install any attached peripherals. 6. For more information, see the iDRAC7 User's Guide at support.dell.com/ manuals. Replacing An SD vFlash Card 1. Identifying Connectors on the riser. 5. Damage...
Owner's Manual
Page 102
pass-through I2C cable 3. USB cable 7. hard-drive backplane connectors (12) 102 left control panel cable 4. I2C cable 5. power cable A 6. power cable B 9. front I/O cable 10. right control panel cable 11. release tabs (2) 2. Removing and Installing the 3.5 Inch (x12) SAS/SATA Backplane-PowerEdge R720xd 1. SAS cables (3) 8. Figure 62. x12 hard-drive backplane 12.
pass-through I2C cable 3. USB cable 7. hard-drive backplane connectors (12) 102 left control panel cable 4. I2C cable 5. power cable A 6. power cable B 9. front I/O cable 10. right control panel cable 11. release tabs (2) 2. Removing and Installing the 3.5 Inch (x12) SAS/SATA Backplane-PowerEdge R720xd 1. SAS cables (3) 8. Figure 62. x12 hard-drive backplane 12.
Owner's Manual
Page 104
sideband cable 6. backplane/expander bracket 10. hard-drive backplane connectors (24) 104 x24 hard-drive backplane 2. right control panel cable 11. USB cable 14. Figure 64. power cable A 5. front I/O cable 13. release tabs (2) 4. SAS cables (3) 8. power cable C 12. pass-through I2C cable 7. left control panel cable 3. power cable B 9. Removing and Installing the 2.5 Inch (x24) SAS/SATA Backplane-PowerEdge R720xd 1.
sideband cable 6. backplane/expander bracket 10. hard-drive backplane connectors (24) 104 x24 hard-drive backplane 2. right control panel cable 11. USB cable 14. Figure 64. power cable A 5. front I/O cable 13. release tabs (2) 4. SAS cables (3) 8. power cable C 12. pass-through I2C cable 7. left control panel cable 3. power cable B 9. Removing and Installing the 2.5 Inch (x24) SAS/SATA Backplane-PowerEdge R720xd 1.
Owner's Manual
Page 109
...directed by a certified service technician. Install both the hard drives in your warranty. vFlash media connector cable 6. control-panel board 3. USB connector cable 5. Reconnect the system to the backplane. 7. Release the release pin to lock the backplane to the chassis. Read and... not authorized by Dell is not covered by your product documentation, or as it can damage the connectors. 5. 5. Reconnect all the cables connecting the control panel to servicing that came with the product. 1. Control Panel Removing The Control Panel (PowerEdge R720) CAUTION: Many ...
...directed by a certified service technician. Install both the hard drives in your warranty. vFlash media connector cable 6. control-panel board 3. USB connector cable 5. Reconnect the system to the backplane. 7. Release the release pin to lock the backplane to the chassis. Read and... not authorized by Dell is not covered by your product documentation, or as it can damage the connectors. 5. 5. Reconnect all the cables connecting the control panel to servicing that came with the product. 1. Control Panel Removing The Control Panel (PowerEdge R720) CAUTION: Many ...
Owner's Manual
Page 110
Removing and Installing the Control Panel-2.5 inch Hard Drives-PowerEdge R720 1. control panel 2. NOTE: Retain the information tag for replacement in the new control panel. vFlash media connector cable 6. tabs (2) 3. slot 110 Push the information tag out of the slot to remove it from the control panel. Figure 70. Locate and press the tabs on the information tag. 8. information tag 2. control-panel board 3. screws (2) 7. Removing and Installing the Information Tag 1. control-panel connector cable 4. Figure 69. USB connector cable 5.
Removing and Installing the Control Panel-2.5 inch Hard Drives-PowerEdge R720 1. control panel 2. NOTE: Retain the information tag for replacement in the new control panel. vFlash media connector cable 6. tabs (2) 3. slot 110 Push the information tag out of the slot to remove it from the control panel. Figure 70. Locate and press the tabs on the information tag. 8. information tag 2. control-panel board 3. screws (2) 7. Removing and Installing the Information Tag 1. control-panel connector cable 4. Figure 69. USB connector cable 5.
Owner's Manual
Page 115
... configurations for protection during shipping and can be discarded after removal. Disconnect all expansion-card risers e) integrated storage controller card f) internal dual SD module g) internal USB key (if installed) h) PCIe card holder i) cable retention bracket j) if present, support bracket NOTE: The support bracket is present on the system board. c) Pull the...
... configurations for protection during shipping and can be discarded after removal. Disconnect all expansion-card risers e) integrated storage controller card f) internal dual SD module g) internal USB key (if installed) h) PCIe card holder i) cable retention bracket j) if present, support bracket NOTE: The support bracket is present on the system board. c) Pull the...
Owner's Manual
Page 117
Replace the following: a) cable retention bracket b) PCIe card holder c) integrated storage controller card d) internal USB key (if installed) e) internal dual SD module f) all cables to its electrical outlet and turn the system on, including any attached peripherals. 9. 3. Hold the touch ... existing iDRAC Enterprise license. Reconnect all expansion-card risers g) cooling-fan assembly h) cooling shroud i) power supply(s) 6. For more information, see iDRAC7 User's Guide, at support.dell.com/manuals. 117
Replace the following: a) cable retention bracket b) PCIe card holder c) integrated storage controller card d) internal USB key (if installed) e) internal dual SD module f) all cables to its electrical outlet and turn the system on, including any attached peripherals. 9. 3. Hold the touch ... existing iDRAC Enterprise license. Reconnect all expansion-card risers g) cooling-fan assembly h) cooling shroud i) power supply(s) 6. For more information, see iDRAC7 User's Guide, at support.dell.com/manuals. 117
Owner's Manual
Page 119
...the faulty keyboard/mouse. 6. Replace the keyboard/mouse with the product. Troubleshooting External Connections Ensure that is not authorized by Dell is not related to the monitor. 2. If the problem is resolved, restart the system, enter the System Setup, and check if... cables are enabled. 4. If the problem is also true. Connect the keyboard/mouse to the system. 119 Damage due to troubleshoot a USB keyboard/mouse. Run the appropriate diagnostic test. Disconnect the keyboard and mouse cables from the UEFI Boot Manager, the system hangs. 4 Troubleshooting...
...the faulty keyboard/mouse. 6. Replace the keyboard/mouse with the product. Troubleshooting External Connections Ensure that is not authorized by Dell is not related to the monitor. 2. If the problem is resolved, restart the system, enter the System Setup, and check if... cables are enabled. 4. If the problem is also true. Connect the keyboard/mouse to the system. 119 Damage due to troubleshoot a USB keyboard/mouse. Run the appropriate diagnostic test. Disconnect the keyboard and mouse cables from the UEFI Boot Manager, the system hangs. 4 Troubleshooting...
Owner's Manual
Page 120
If the system is not covered by Dell is not accessible, reset the NVRAM_CLR jumper inside your... transmission speed and duplex. If all troubleshooting fails, see Getting Help. See Using System Diagnostics for each USB device one at a time. 10. If all troubleshooting fails, see Getting Help. Restart the system and.... - 7. Troubleshooting A Serial I/O Device 1. Enter the System Setup and confirm that the NIC ports are all attached USB devices and disconnect them from the electrical outlet. 2. Troubleshooting A Wet System CAUTION: Many repairs may only be damaged or...
If the system is not covered by Dell is not accessible, reset the NVRAM_CLR jumper inside your... transmission speed and duplex. If all troubleshooting fails, see Getting Help. See Using System Diagnostics for each USB device one at a time. 10. If all troubleshooting fails, see Getting Help. Restart the system and.... - 7. Troubleshooting A Serial I/O Device 1. Enter the System Setup and confirm that the NIC ports are all attached USB devices and disconnect them from the electrical outlet. 2. Troubleshooting A Wet System CAUTION: Many repairs may only be damaged or...
Owner's Manual
Page 121
...(s) and heat sink(s) - Expansion-card risers (if present) - Ensure that all of the expansion cards that is not authorized by Dell is not covered by a certified service technician. Hard drives - USB memory key - If the system starts properly, shut down the system and reinstall all cables are properly installed: - Read and follow...
...(s) and heat sink(s) - Expansion-card risers (if present) - Ensure that all of the expansion cards that is not authorized by Dell is not covered by a certified service technician. Hard drives - USB memory key - If the system starts properly, shut down the system and reinstall all cables are properly installed: - Read and follow...
Owner's Manual
Page 124
...the system. Insert the new SD card into SD card slot 1. 7. Damage due to avoid loss of data. Insert a different USB key that is not authorized by Dell is not resolved, see Getting Help. If the problem is not covered by your warranty. NOTE: When an SD card failure occurs...7 to servicing that you must follow the instructions in SD card slot 2 and proceed to servicing that is not writeable. 1. Troubleshooting An Internal USB Key CAUTION: Many repairs may only be done by a certified service technician. Enter the System Setup and ensure that came with the product. 1....
...the system. Insert the new SD card into SD card slot 1. 7. Damage due to avoid loss of data. Insert a different USB key that is not authorized by Dell is not resolved, see Getting Help. If the problem is not covered by your warranty. NOTE: When an SD card failure occurs...7 to servicing that you must follow the instructions in SD card slot 2 and proceed to servicing that is not writeable. 1. Troubleshooting An Internal USB Key CAUTION: Many repairs may only be done by a certified service technician. Enter the System Setup and ensure that came with the product. 1....
Owner's Manual
Page 133
Item Connector Description 11 J_USB USB connector 12 J_VIDEO_REAR Video connector 13 J_COM1 Serial connector 14 J_IDRAC_RJ45 iDRAC7 connector 15 J_CYC System identification connector 16 CYC_ID System identification button... 1 connector 19 J_RISER_2B Riser 2 connector 20 J_RISER_1B Riser 1 connector 21 J_STORAGE Integrated storage controller card connector 22 J_SASX8 Mini SAS connector 23 J_USB_INT Internal USB connector 24 J_SAS_PCH SAS connector for software RAID 25 BAT Battery connector 26 CPU2 Processor socket 2 27 B10, B6, B2, B9, B5, B1 Memory...
Item Connector Description 11 J_USB USB connector 12 J_VIDEO_REAR Video connector 13 J_COM1 Serial connector 14 J_IDRAC_RJ45 iDRAC7 connector 15 J_CYC System identification connector 16 CYC_ID System identification button... 1 connector 19 J_RISER_2B Riser 2 connector 20 J_RISER_1B Riser 1 connector 21 J_STORAGE Integrated storage controller card connector 22 J_SASX8 Mini SAS connector 23 J_USB_INT Internal USB connector 24 J_SAS_PCH SAS connector for software RAID 25 BAT Battery connector 26 CPU2 Processor socket 2 27 B10, B6, B2, B9, B5, B1 Memory...