Getting Started Guide
Page 9
...cell Physical Height Width With rack latches Without rack latches Depth (includes bezel) Weight (maximum) 2.5-inch hard-drive systems 3.5-inch hard-drive systems (PowerEdge R720) 3.5-inch hard-drive systems (PowerEdge R720xd) Weight (empty) 2.5-inch hard-drive systems 3.5-inch hard-drive systems 87.3 mm... lbs) 10.3 kg (22.7 lbs) Environmental NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets. Temperature Operating Continuous operation: 10 °C to 35 °C at 10% to 80% relative humidity (RH...
...cell Physical Height Width With rack latches Without rack latches Depth (includes bezel) Weight (maximum) 2.5-inch hard-drive systems 3.5-inch hard-drive systems (PowerEdge R720) 3.5-inch hard-drive systems (PowerEdge R720xd) Weight (empty) 2.5-inch hard-drive systems 3.5-inch hard-drive systems 87.3 mm... lbs) 10.3 kg (22.7 lbs) Environmental NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets. Temperature Operating Continuous operation: 10 °C to 35 °C at 10% to 80% relative humidity (RH...
Technical Guide
Page 3
......52 Chassis weight...52 Power supply specifications ...53 Environmental specifications ...53 Video specifications ...54 Rack rail specifications ...55 USB peripherals ...55 iii PowerEdge R720 and R720xd Technical Guide Table of contents 1 System overview...6 Introduction...6 New technologies ...7 2 System features ...8 Specifications ...8 Comparison of PowerEdge systems ...10 ... systems and virtualization ...42 Supported operating systems...42 Supported virtualization ...43 11 Dell OpenManage systems management...44 Systems management solutions ...44 OpenManage systems management ...45...
......52 Chassis weight...52 Power supply specifications ...53 Environmental specifications ...53 Video specifications ...54 Rack rail specifications ...55 USB peripherals ...55 iii PowerEdge R720 and R720xd Technical Guide Table of contents 1 System overview...6 Introduction...6 New technologies ...7 2 System features ...8 Specifications ...8 Comparison of PowerEdge systems ...10 ... systems and virtualization ...42 Supported operating systems...42 Supported virtualization ...43 11 Dell OpenManage systems management...44 Systems management solutions ...44 OpenManage systems management ...45...
Technical Guide
Page 4
... efficiency ...36 Table 21. One-to-one and one-to-many operations 50 Table 30. Chassis weight ...52 Table 31. Additional resources ...57 Figure 1. R720xd front view (2.5-inch chassis without bezel 11 Figure 3. Comparison of PowerEdge R710, R720, and R720xd 10 Table 4. DIMMs supported ...22 Table 9. Chassis options...25 Table 12. Power tools and technologies...
... efficiency ...36 Table 21. One-to-one and one-to-many operations 50 Table 30. Chassis weight ...52 Table 31. Additional resources ...57 Figure 1. R720xd front view (2.5-inch chassis without bezel 11 Figure 3. Comparison of PowerEdge R710, R720, and R720xd 10 Table 4. DIMMs supported ...22 Table 9. Chassis options...25 Table 12. Power tools and technologies...
Technical Guide
Page 38
...is 75 cm above reflective floor). 3Prominent tone: Criteria of D.6 and D.11 of more information on Dell's acoustical design, see the Dell Enterprise Acoustics white paper. 38 PowerEdge R720 and R720xd Technical Guide UL is the upper limit sound power levels (LwA) calculated per section 4.3 of ISO 9296... (1988) and measured in accordance to ISO 7779 (2010). 2LpA is the average A-weighted sound pressure level...
...is 75 cm above reflective floor). 3Prominent tone: Criteria of D.6 and D.11 of more information on Dell's acoustical design, see the Dell Enterprise Acoustics white paper. 38 PowerEdge R720 and R720xd Technical Guide UL is the upper limit sound power levels (LwA) calculated per section 4.3 of ISO 9296... (1988) and measured in accordance to ISO 7779 (2010). 2LpA is the average A-weighted sound pressure level...
Technical Guide
Page 52
....4mm 444.0mm 87.3mm Za Za (with bezel) (without bezel) Zb Zc 32.0mm 18.0mm 684.0mm 723.0mm Table 30 lists the weight of the R720 and R720xd chassis at maximum configuration as well as empty of the Dell™ PowerEdge™ R720 and R720xd chassis. Figure 18 details the dimensions of any hardware.
....4mm 444.0mm 87.3mm Za Za (with bezel) (without bezel) Zb Zc 32.0mm 18.0mm 684.0mm 723.0mm Table 30 lists the weight of the R720 and R720xd chassis at maximum configuration as well as empty of the Dell™ PowerEdge™ R720 and R720xd chassis. Figure 18 details the dimensions of any hardware.