Glossary
Page 1
...British thermal unit. Your system contains an expansion bus that contains a processor, memory, and a hard drive. CIM - Centimeter(s). 1 Dell™ Glossary NOTE: For additional information on storage terminology, visit the Storage Networking Industry Association's website at www.snia.org and click ...the peripheral devices connected to start your system's hard drive(s) on the dictionary. The modules are mounted into a chassis that includes power supplies and fans. BMC - asset tag - A - A standard interface for developing technology standards in the U.S. As a precaution, ...
...British thermal unit. Your system contains an expansion bus that contains a processor, memory, and a hard drive. CIM - Centimeter(s). 1 Dell™ Glossary NOTE: For additional information on storage terminology, visit the Storage Networking Industry Association's website at www.snia.org and click ...the peripheral devices connected to start your system's hard drive(s) on the dictionary. The modules are mounted into a chassis that includes power supplies and fans. BMC - asset tag - A - A standard interface for developing technology standards in the U.S. As a precaution, ...
Glossary
Page 8
...in the cable. termination - When such devices are video standards for the devices. An unregistered (unbuffered) DDR3 memory module. Uninterruptible power supply. SMP - Symmetric multiprocessing. The amount of space used by an operating system, where each end of the space on the same... or switch used . system configuration information - Data stored in an array. A BIOS-based program that automatically supplies power to other hubs or switches without requiring a crossover cable. Transmission Control Protocol/Internet Protocol. TOE - TCP/IP offload engine. A battery...
...in the cable. termination - When such devices are video standards for the devices. An unregistered (unbuffered) DDR3 memory module. Uninterruptible power supply. SMP - Symmetric multiprocessing. The amount of space used by an operating system, where each end of the space on the same... or switch used . system configuration information - Data stored in an array. A BIOS-based program that automatically supplies power to other hubs or switches without requiring a crossover cable. Transmission Control Protocol/Internet Protocol. TOE - TCP/IP offload engine. A battery...
Glossary
Page 48
Watt WH - SMART - Uninterruptible power supply USB - Volt direct current VGA - Watt-hour WMI - Simple Network Management Protocol SVGA - Unregistered DDR3 UPS - Windows Management Instrumentation。CIM ZIF - Super video graphics ...
Watt WH - SMART - Uninterruptible power supply USB - Volt direct current VGA - Watt-hour WMI - Simple Network Management Protocol SVGA - Unregistered DDR3 UPS - Windows Management Instrumentation。CIM ZIF - Super video graphics ...
Glossary
Page 58
Windows Management Instrumentation 은 CIM ZIF Zero Insertion Force provider CIM management station managed system) 은 Dell OpenManage™ Server Administrator x x y x z 58 TCP/IP TCP/IP Offload Engine U-DIMM DDR3 Unregistered(Unbuffered) DDR3 Memory Module UPS Uninterruptible Power Supply USB Universal Serial Bus USB USB USB USB V - 볼트 (Volt VAC Volt Alternating Current...
Windows Management Instrumentation 은 CIM ZIF Zero Insertion Force provider CIM management station managed system) 은 Dell OpenManage™ Server Administrator x x y x z 58 TCP/IP TCP/IP Offload Engine U-DIMM DDR3 Unregistered(Unbuffered) DDR3 Memory Module UPS Uninterruptible Power Supply USB Universal Serial Bus USB USB USB USB V - 볼트 (Volt VAC Volt Alternating Current...
Information Update - Power Infrastructure Sizing
Page 1
... available from Dell system management software provide additional predictability for a particular system configuration. Example: If a server power supply is specific to the system configuration and to understand peak power consumption for peak power consumption. The power supply-rated approach requires additional power and cooling and results in 500W of Power Distribution Units (PDUs), Uninterruptible Power Supplies (UPSs), and other power infrastructure distribution...
... available from Dell system management software provide additional predictability for a particular system configuration. Example: If a server power supply is specific to the system configuration and to understand peak power consumption for peak power consumption. The power supply-rated approach requires additional power and cooling and results in 500W of Power Distribution Units (PDUs), Uninterruptible Power Supplies (UPSs), and other power infrastructure distribution...
Getting Started Guide
Page 7
Plug the other end of the power cables into a loop as an uninterruptible power supply (UPS) or a power distribution unit (PDU). Turning on the System Press the power button on the system and the monitor. Getting Started With Your System 5 The power indicators should light. Securing the Power Cord Bend the system power cable into a grounded electrical outlet or a separate power source such as shown in the illustration and secure the cable to the bracket using the provided strap.
Plug the other end of the power cables into a loop as an uninterruptible power supply (UPS) or a power distribution unit (PDU). Turning on the System Press the power button on the system and the monitor. Getting Started With Your System 5 The power indicators should light. Securing the Power Cord Bend the system power cable into a grounded electrical outlet or a separate power source such as shown in the illustration and secure the cable to the bracket using the provided strap.
Getting Started Guide
Page 12
...cm (18.99 in) with rack latches 44.31 cm (17.4 in) without rack latches 72.06 cm(28.4 in) with power supplies and bezel 68.07 cm(26.8) without power supplies and bezel 26.1 kg (57.54 lb) 17.7 kg (39 lb) 10 Getting Started With Your System Video Video type Video memory... Integrated Matrox G200 8 MB shared Power AC Power Supply (per power supply) Wattage 870 W (High Output) 570 W /200840 KB (Energy Smart) Voltage 90-264 VAC, autoranging, 47-63 Hz Heat dissipation 2968.6 BTU/hr maximum (...
...cm (18.99 in) with rack latches 44.31 cm (17.4 in) without rack latches 72.06 cm(28.4 in) with power supplies and bezel 68.07 cm(26.8) without power supplies and bezel 26.1 kg (57.54 lb) 17.7 kg (39 lb) 10 Getting Started With Your System Video Video type Video memory... Integrated Matrox G200 8 MB shared Power AC Power Supply (per power supply) Wattage 870 W (High Output) 570 W /200840 KB (Energy Smart) Voltage 90-264 VAC, autoranging, 47-63 Hz Heat dissipation 2968.6 BTU/hr maximum (...
Hardware Owner's Manual
Page 5
... Hard Drive 82 Installing a Hot-Swap Hard Drive 83 Removing a Hard Drive From a Hard-Drive Carrier 84 Installing a Hard Drive Into a Hard-Drive Carrier 84 Power Supplies 86 Removing a Power Supply 86 Replacing a Power Supply 87 Removing the Power Supply Blank 88 Installing the Power Supply Blank 88 Contents 5
... Hard Drive 82 Installing a Hot-Swap Hard Drive 83 Removing a Hard Drive From a Hard-Drive Carrier 84 Installing a Hard Drive Into a Hard-Drive Carrier 84 Power Supplies 86 Removing a Power Supply 86 Replacing a Power Supply 87 Removing the Power Supply Blank 88 Installing the Power Supply Blank 88 Contents 5
Hardware Owner's Manual
Page 9
...a NIC 155 Troubleshooting a Wet System 156 Troubleshooting a Damaged System 157 Troubleshooting the System Battery 158 Troubleshooting Power Supplies 158 Troubleshooting System Cooling Problems 159 Troubleshooting a Fan 160 Troubleshooting System Memory 160 Troubleshooting an Internal SD Card...Troubleshooting Expansion Cards 168 Troubleshooting the Processor(s 170 5 Running the System Diagnostics . . . . . 173 Using Dell™ PowerEdge™ Diagnostics 173 System Diagnostics Features 173 When to Use the System Diagnostics 174 Running the System Diagnostics 174 Contents 9
...a NIC 155 Troubleshooting a Wet System 156 Troubleshooting a Damaged System 157 Troubleshooting the System Battery 158 Troubleshooting Power Supplies 158 Troubleshooting System Cooling Problems 159 Troubleshooting a Fan 160 Troubleshooting System Memory 160 Troubleshooting an Internal SD Card...Troubleshooting Expansion Cards 168 Troubleshooting the Processor(s 170 5 Running the System Diagnostics . . . . . 173 Using Dell™ PowerEdge™ Diagnostics 173 System Diagnostics Features 173 When to Use the System Diagnostics 174 Running the System Diagnostics 174 Contents 9
Hardware Owner's Manual
Page 13
... installed in the system. The ports are USB 2.0-complaint. Connects USB devices to the system. The power button controls the DC power supply output to the system. NOTE: To force an ungraceful shutdown, press and hold the power button for system information including the Express Service tag, Embedded NIC1 MAC address, and iDRAC6 Enterprise...
... installed in the system. The ports are USB 2.0-complaint. Connects USB devices to the system. The power button controls the DC power supply output to the system. NOTE: To force an ungraceful shutdown, press and hold the power button for system information including the Express Service tag, Embedded NIC1 MAC address, and iDRAC6 Enterprise...
Hardware Owner's Manual
Page 20
... system Connector for the optional iDRAC6 Enterprise card 20 About Your System Item Indicator, Button, or Icon Connector 4 PCIe slot 4 5 power supply 1 (PS1) 6 power supply 2 (PS2) 7 system identification button 8 system status indicator 9 system status indicator connector 10 Ethernet connectors (4) 11 USB connectors (2) ... Description PCIe x8-link Gen 2 expansion slot (fullheight, 24.13-cm [9.5-in] length) 870-W or 570-W power supply 870-W or 570-W power supply The identification buttons on the front and back panels can be used on the back flash blue until one of these ...
... system Connector for the optional iDRAC6 Enterprise card 20 About Your System Item Indicator, Button, or Icon Connector 4 PCIe slot 4 5 power supply 1 (PS1) 6 power supply 2 (PS2) 7 system identification button 8 system status indicator 9 system status indicator connector 10 Ethernet connectors (4) 11 USB connectors (2) ... Description PCIe x8-link Gen 2 expansion slot (fullheight, 24.13-cm [9.5-in] length) 870-W or 570-W power supply 870-W or 570-W power supply The identification buttons on the front and back panels can be used on the back flash blue until one of these ...
Hardware Owner's Manual
Page 21
... a power supply mismatch, replace only the power supply with a power supply that the power supply is operational. In standby mode, indicates that a valid AC source is connected to the system. • Amber - Replace the power supply that the power supply is not connected. • Green - AC power is providing DC power to the power supply and that matches the capacity of the other power supply (a High Output 870-W power supply...
... a power supply mismatch, replace only the power supply with a power supply that the power supply is operational. In standby mode, indicates that a valid AC source is connected to the system. • Amber - Replace the power supply that the power supply is not connected. • Green - AC power is providing DC power to the power supply and that matches the capacity of the other power supply (a High Output 870-W power supply...
Hardware Owner's Manual
Page 22
NIC Indicators 1 2 1 link indicator 2 activity indicator Indicator Link and activity indicators are off Description The NIC is not connected to the network. 22 About Your System Power Supply Status Indicator 1 1 power supply status NIC Indicator Codes Figure 1-7. Figure 1-6.
NIC Indicators 1 2 1 link indicator 2 activity indicator Indicator Link and activity indicators are off Description The NIC is not connected to the network. 22 About Your System Power Supply Status Indicator 1 1 power supply status NIC Indicator Codes Figure 1-7. Figure 1-6.
Hardware Owner's Manual
Page 27
... "Troubleshooting Power Supplies." E1610 Power Supply # (### W) missing. E1614 Power Supply Specified power supply has See "Troubleshooting # (### W) failed. See "Troubleshooting Power Supplies." If the problem persists, see "Getting Help." AC. Power cycle AC. Remove AC power to the system for 10 seconds and restart the system. Check power supply. Check PSU. E1422 CPU # machine check error. Check power supply. Power Supplies error. E161C Power Supply # (### W) lost its AC input. Specified power supply was...
... "Troubleshooting Power Supplies." E1610 Power Supply # (### W) missing. E1614 Power Supply Specified power supply has See "Troubleshooting # (### W) failed. See "Troubleshooting Power Supplies." If the problem persists, see "Getting Help." AC. Power cycle AC. Remove AC power to the system for 10 seconds and restart the system. Check power supply. Check PSU. E1422 CPU # machine check error. Check power supply. Power Supplies error. E161C Power Supply # (### W) lost its AC input. Specified power supply was...
Hardware Owner's Manual
Page 28
... Actions E1620 Power Supply # (### W) AC power error. Check PSU cables. redundant. Ensure that power supplies with throttling. E1710 I /O channel check. If the problem persists, see "Troubleshooting Power Supplies." Table 1-1. Specified power supply's AC input is no longer Power Supplies." Remove AC power to the system, reduce the hardware configuration or install higher-wattage power supplies, and then restart the system. E1626 Power Supply The power supplies in your...
... Actions E1620 Power Supply # (### W) AC power error. Check PSU cables. redundant. Ensure that power supplies with throttling. E1710 I /O channel check. If the problem persists, see "Troubleshooting Power Supplies." Table 1-1. Specified power supply's AC input is no longer Power Supplies." Remove AC power to the system, reduce the hardware configuration or install higher-wattage power supplies, and then restart the system. E1626 Power Supply The power supplies in your...
Hardware Owner's Manual
Page 36
.... NOTE: For the full name of sustained charge. Check SEL to the system, reduce the hardware configuration or install higher-wattage power supplies, and then restart the system. LCD overflow message. A maximum of events and is unable to the system, reduce the hardware... see "Glossary." 36 About Your System The system configuration requires more power than what the power supply can provide. W1228 RAID Controller battery capacity < 24hr. Remove AC power to greater than what the power supply can provide, but it can display sequentially on the events. Warns predictively...
.... NOTE: For the full name of sustained charge. Check SEL to the system, reduce the hardware configuration or install higher-wattage power supplies, and then restart the system. LCD overflow message. A maximum of events and is unable to the system, reduce the hardware... see "Glossary." 36 About Your System The system configuration requires more power than what the power supply can provide. W1228 RAID Controller battery capacity < 24hr. Remove AC power to greater than what the power supply can provide, but it can display sequentially on the events. Warns predictively...
Hardware Owner's Manual
Page 39
...continued) Message Causes Corrective Actions Alert! If the system boots without warning. If Energy Smart power supplies are not supported with the High Output power supplies to take the system mode. System is in the system setup program, but the current ...configuration does not support redundant memory. BIOS MANUFACTURING MODE detected. Memory configuration does not support redundant memory. See "Power Supplies." Reset the memory setting, if appropriate. Check the memory modules for possible causes. System reboot required for normal operation...
...continued) Message Causes Corrective Actions Alert! If the system boots without warning. If Energy Smart power supplies are not supported with the High Output power supplies to take the system mode. System is in the system setup program, but the current ...configuration does not support redundant memory. BIOS MANUFACTURING MODE detected. Memory configuration does not support redundant memory. See "Power Supplies." Reset the memory setting, if appropriate. Check the memory modules for possible causes. System reboot required for normal operation...
Hardware Owner's Manual
Page 52
...configuration. then the replaced Warning! modules, and expansion the system to use the components. See "Power Supplies." You can also run but with High Output power supplies to the previous Check PSU and cards may not be supported configuration. The memory configuration is ...Troubleshooting System Memory." 52 About Your System If the system system by the power supplies. Performance degraded. System will run the system on one power supply until you can obtain two power supplies of If any system components required exceeds processor(s), memory were just upgraded, return...
...configuration. then the replaced Warning! modules, and expansion the system to use the components. See "Power Supplies." You can also run but with High Output power supplies to the previous Check PSU and cards may not be supported configuration. The memory configuration is ...Troubleshooting System Memory." 52 About Your System If the system system by the power supplies. Performance degraded. System will run the system on one power supply until you can obtain two power supplies of If any system components required exceeds processor(s), memory were just upgraded, return...
Hardware Owner's Manual
Page 76
... card (optional) 11 SAS backplane 13 RAID battery (PERC only) 15 control panel 2 Internal SD Module 4 memory modules (up to 18 total, 9 for each processor) 6 power supply bays (2) 8 riser 1 (PCIe slots 1 and 2) 10 integrated storage controller card 12 SAS or SATA hard drives (up to 8) 14 flex bay for optional tape backup...
... card (optional) 11 SAS backplane 13 RAID battery (PERC only) 15 control panel 2 Internal SD Module 4 memory modules (up to 18 total, 9 for each processor) 6 power supply bays (2) 8 riser 1 (PCIe slots 1 and 2) 10 integrated storage controller card 12 SAS or SATA hard drives (up to 8) 14 flex bay for optional tape backup...
Hardware Owner's Manual
Page 79
... the system, get others to assist you are installing a hot-swappable component such as authorized in a clockwise direction to servicing that is not authorized by Dell is not covered by your product documentation, or as directed by the online or telephone service and support team. To avoid injury, do not attempt... and Closing the System CAUTION: Many repairs may only be done by yourself. You should only perform troubleshooting and simple repairs as a cooling fan or power supply, turn off the system and attached peripherals, and disconnect the system from the system.
... the system, get others to assist you are installing a hot-swappable component such as authorized in a clockwise direction to servicing that is not authorized by Dell is not covered by your product documentation, or as directed by the online or telephone service and support team. To avoid injury, do not attempt... and Closing the System CAUTION: Many repairs may only be done by yourself. You should only perform troubleshooting and simple repairs as a cooling fan or power supply, turn off the system and attached peripherals, and disconnect the system from the system.