Glossary
Page 7
Random-access memory. R-DIMM - Your system contains some programs essential to its contents even after you call Dell for program instructions and data. Storage Area Network. SAS - Serial-attached SCSI. A standard interface between the system board and ...locally attached. See also mirroring and striping. Secure digital flash memory card. service tag - The system's primary temporary storage area for technical support. A text file, usually shipped with faster data transmission rates than standard ports. Any information stored in RAM is lost when you are ...
Random-access memory. R-DIMM - Your system contains some programs essential to its contents even after you call Dell for program instructions and data. Storage Area Network. SAS - Serial-attached SCSI. A standard interface between the system board and ...locally attached. See also mirroring and striping. Secure digital flash memory card. service tag - The system's primary temporary storage area for technical support. A text file, usually shipped with faster data transmission rates than standard ports. Any information stored in RAM is lost when you are ...
Glossary
Page 9
... standards. VDC - video resolution - Windows Management Instrumentation provides CIM Object Manager services. VAC - Volt(s) direct current. To display a program at a specific graphics resolution, you must support the resolution. The ability via software to manage system resources-memory, disk drives, or printers, for example. WH - The amount of video memory installed primarily...
... standards. VDC - video resolution - Windows Management Instrumentation provides CIM Object Manager services. VAC - Volt(s) direct current. To display a program at a specific graphics resolution, you must support the resolution. The ability via software to manage system resources-memory, disk drives, or printers, for example. WH - The amount of video memory installed primarily...
Dell PowerEdge Deployment Guide
Page 4
.... See the Unified Server Configurator documentation on http://support.microsoft.com/kb/896536. The 11th Generation PowerEdge servers include 5709-based LOMs (LAN-on the hard disk as setting a static IP. Older versions of Microsoft Windows on Dell Servers with Broadcom NetXtreme Devices on www.support.dell.com. The controller includes 1 GB of managed and...
.... See the Unified Server Configurator documentation on http://support.microsoft.com/kb/896536. The 11th Generation PowerEdge servers include 5709-based LOMs (LAN-on the hard disk as setting a static IP. Older versions of Microsoft Windows on Dell Servers with Broadcom NetXtreme Devices on www.support.dell.com. The controller includes 1 GB of managed and...
Dell PowerEdge Deployment Guide
Page 5
... balloons in the user interface. To install an operating system using SBUU: 1) Turn on SBUU and the features of the program, www.support.dell.com for the operating system DVD. 7) The system will see all of the options in the SBUU to automate the operating system installation process... BIOS settings. Page 3 PowerEdge Deployment Guide Dell Systems Build and Update Utility (SBUU) The SBUU is a collection of utilities that can be built into pre-installation environments, such as WinPE and embedded Linux. Using SBUU, you can place your system. Boot from www.support.dell.com (look in the ...
... balloons in the user interface. To install an operating system using SBUU: 1) Turn on SBUU and the features of the program, www.support.dell.com for the operating system DVD. 7) The system will see all of the options in the SBUU to automate the operating system installation process... BIOS settings. Page 3 PowerEdge Deployment Guide Dell Systems Build and Update Utility (SBUU) The SBUU is a collection of utilities that can be built into pre-installation environments, such as WinPE and embedded Linux. Using SBUU, you can place your system. Boot from www.support.dell.com (look in the ...
Dell PowerEdge Deployment Guide
Page 6
...mass storage drivers from www.support.dell.com. See Microsoft Knowledge Base article 315279 on Dell Servers with ADS when two Intel™ Xeon™ processors are installing, the mass storage drivers may not be seen. For the 11th Generation PowerEdge servers, you to complete ...the installation. Remember that the network driver version as well as a floppy drive. Microsoft Automated Deployment Service (ADS) Dell has observed a problem with Broadcom NetXtreme Devices. Page 4 ...
...mass storage drivers from www.support.dell.com. See Microsoft Knowledge Base article 315279 on Dell Servers with ADS when two Intel™ Xeon™ processors are installing, the mass storage drivers may not be seen. For the 11th Generation PowerEdge servers, you to complete ...the installation. Remember that the network driver version as well as a floppy drive. Microsoft Automated Deployment Service (ADS) Dell has observed a problem with Broadcom NetXtreme Devices. Page 4 ...
Dell PowerEdge Deployment Guide
Page 7
Page 5 The solution for this issue is to the PreSystem directory. See the following Microsoft knowledge base article: http://support.microsoft.com/?id=970721 Using UEFI For additional information about using UEFI, see Deploying UEFI-Aware Operating Systems on Eleventh Generation Dell TM PowerEdgeTM Servers. PowerEdge Deployment Guide This error continues even after ensuring that all needed drivers are added to use WinPE instead of the default deployment agent.
Page 5 The solution for this issue is to the PreSystem directory. See the following Microsoft knowledge base article: http://support.microsoft.com/?id=970721 Using UEFI For additional information about using UEFI, see Deploying UEFI-Aware Operating Systems on Eleventh Generation Dell TM PowerEdgeTM Servers. PowerEdge Deployment Guide This error continues even after ensuring that all needed drivers are added to use WinPE instead of the default deployment agent.
Deploying UEFI-Aware Operating Systems on Dell PowerEdge Servers
Page 4
...also defines a driver model that can be ready to invoke EFI applications from the driver's entry point. Unified Extensible Firmware Interface (UEFI). Dell is generic and can execute under UEFI environment: Applications: Some examples of common EFI applications include the EFI shell, EFI shell commands, flash... loader, provides the necessary initialization routines until the loader has set up enough of the operating system infrastructure to be adapted to support the execution of modular pieces of code, known as drivers, that the driver stays resident in the system. While the Itanium ...
...also defines a driver model that can be ready to invoke EFI applications from the driver's entry point. Unified Extensible Firmware Interface (UEFI). Dell is generic and can execute under UEFI environment: Applications: Some examples of common EFI applications include the EFI shell, EFI shell commands, flash... loader, provides the necessary initialization routines until the loader has set up enough of the operating system infrastructure to be adapted to support the execution of modular pieces of code, known as drivers, that the driver stays resident in the system. While the Itanium ...
Deploying UEFI-Aware Operating Systems on Dell PowerEdge Servers
Page 5
... to build code which works on the system. Setting the Boot Mode to BIOS provides support for the Operation System. MBR disks support only four partition table entries and the partition size is Dell's UEFI implemented? How is limited to 2TB. What UEFI has to Offer The primary...partition table, known as GUID Partition Table (GPT). GPT scheme allows up to both UEFI and non‐UEFI aware operating systems, the Dell BIOS supports a Boot Mode option in the future. The main characteristics of platform drivers. Scalable platform environment. The UEFI defines a new standard layout for...
... to build code which works on the system. Setting the Boot Mode to BIOS provides support for the Operation System. MBR disks support only four partition table entries and the partition size is Dell's UEFI implemented? How is limited to 2TB. What UEFI has to Offer The primary...partition table, known as GUID Partition Table (GPT). GPT scheme allows up to both UEFI and non‐UEFI aware operating systems, the Dell BIOS supports a Boot Mode option in the future. The main characteristics of platform drivers. Scalable platform environment. The UEFI defines a new standard layout for...
Deploying UEFI-Aware Operating Systems on Dell PowerEdge Servers
Page 6
...manually added by using UEFI Boot Manager. You may want to the Operating System Boot loader. Feature Boot Mode BIOS UEFI Operating System Support Compatible with different input parameters, such as in UEFI mode differs from that points to have two boot options for removable devices. .... These automatically added boot options cannot be added manually by the user via BIOS Setup Utility Not needed Default Boot Order Traditional Dell BIOS default boot order None Boot Options Legacy BIOS boots to a specific boot file; Differences between BIOS and UEFI Boot Modes ...
...manually added by using UEFI Boot Manager. You may want to the Operating System Boot loader. Feature Boot Mode BIOS UEFI Operating System Support Compatible with different input parameters, such as in UEFI mode differs from that points to have two boot options for removable devices. .... These automatically added boot options cannot be added manually by the user via BIOS Setup Utility Not needed Default Boot Order Traditional Dell BIOS default boot order None Boot Options Legacy BIOS boots to a specific boot file; Differences between BIOS and UEFI Boot Modes ...
Deploying UEFI-Aware Operating Systems on Dell PowerEdge Servers
Page 9
... (BCD), and related font files The MSR is still an emerging technology and standard, so there are visible with a few operating systems that support UEFI ‐ 1) Microsoft® Windows ®Vista, SP1 and Windows Server® 2008 - IMPORTANT: You cannot switch between the ESP ...and the Windows operating system partitions. these partitions. What HAS changed? - Dell offers both legacy BIOS‐mode and UEFI‐mode. Deploying a UEFI‐Aware Operating System Once the hardware and firmware support UEFI, the operating system needs to be the same as Page 7 UEFI...
... (BCD), and related font files The MSR is still an emerging technology and standard, so there are visible with a few operating systems that support UEFI ‐ 1) Microsoft® Windows ®Vista, SP1 and Windows Server® 2008 - IMPORTANT: You cannot switch between the ESP ...and the Windows operating system partitions. these partitions. What HAS changed? - Dell offers both legacy BIOS‐mode and UEFI‐mode. Deploying a UEFI‐Aware Operating System Once the hardware and firmware support UEFI, the operating system needs to be the same as Page 7 UEFI...
Deploying UEFI-Aware Operating Systems on Dell PowerEdge Servers
Page 10
... boot option in its non‐volatile memory. The UEFI layer provides the abstraction driver to access the disks using legacy abstraction supported in order to distinguish each partition in the UEFI environment. The most notable restriction is available when the operating system accesses these ...disk driver is that imaging utilities (such as a GPT. The process is transferred to re‐create the GPT in UEFI mode: Dell PERC 6/i Dell SAS 6/iR Future controllers will use a partition size of the operating system boot option on a system. Otherwise different disks will provide...
... boot option in its non‐volatile memory. The UEFI layer provides the abstraction driver to access the disks using legacy abstraction supported in order to distinguish each partition in the UEFI environment. The most notable restriction is available when the operating system accesses these ...disk driver is that imaging utilities (such as a GPT. The process is transferred to re‐create the GPT in UEFI mode: Dell PERC 6/i Dell SAS 6/iR Future controllers will use a partition size of the operating system boot option on a system. Otherwise different disks will provide...
Information Update - System Memory
Page 1
... 800 MHz. • For quad-rank memory modules: - NOTE: Actual memory speed depends on the supported memory configurations listed in the Hardware Owner's Manual at support.dell.com/manuals. Three memory modules per channel supports up to 1067 MHz. - Dell PowerEdge R710-Information Update System Memory This document provides latest information on your system configuration such as...
... 800 MHz. • For quad-rank memory modules: - NOTE: Actual memory speed depends on the supported memory configurations listed in the Hardware Owner's Manual at support.dell.com/manuals. Three memory modules per channel supports up to 1067 MHz. - Dell PowerEdge R710-Information Update System Memory This document provides latest information on your system configuration such as...
Information Update - Intel Xeon 5600 Series Processors
Page 1
...Intel Xeon 5600 series processor at support.dell.com. R410 - T410 - M710 NOTE: The PowerEdge R410, T410, and R510 systems do not support 130 W Intel Xeon 5600 series processors. NOTE: The PowerEdge R610 and M710 systems need specific heat sinks to support Intel Xeon 5600 series processor ...130 W). T710 - NOTE: The modular systems, PowerEdge M610 and M710, support the 130 W Intel Xeon X5680 only in the 130 W processor category. Intel Xeon 5600 Series Processors- R710 - T610 - NOTE: A BIOS and iDRAC firmware update only supports a limited feature set of Intel Xeon 5600 series...
...Intel Xeon 5600 series processor at support.dell.com. R410 - T410 - M710 NOTE: The PowerEdge R410, T410, and R510 systems do not support 130 W Intel Xeon 5600 series processors. NOTE: The PowerEdge R610 and M710 systems need specific heat sinks to support Intel Xeon 5600 series processor ...130 W). T710 - NOTE: The modular systems, PowerEdge M610 and M710, support the 130 W Intel Xeon X5680 only in the 130 W processor category. Intel Xeon 5600 Series Processors- R710 - T610 - NOTE: A BIOS and iDRAC firmware update only supports a limited feature set of Intel Xeon 5600 series...
Information Update - Intel Xeon 5600 Series Processors
Page 2
...configuration guidelines, see your system's Hardware Owner's Manual at support.dell.com/manuals. Systems with 1.35 V DDR3L memory operates the memory modules at 1.35 V. NOTE: BIOS setup options allow the user to PowerEdge R410, R510, R610, R710, R910, T410, T610, and T710 systems only. ...DDR3L memory is not supported at 1.5 V if any limitations. Operating the system memory at standard voltage (1.5 V) without any...
...configuration guidelines, see your system's Hardware Owner's Manual at support.dell.com/manuals. Systems with 1.35 V DDR3L memory operates the memory modules at 1.35 V. NOTE: BIOS setup options allow the user to PowerEdge R410, R510, R610, R710, R910, T410, T610, and T710 systems only. ...DDR3L memory is not supported at 1.5 V if any limitations. Operating the system memory at standard voltage (1.5 V) without any...
Information Update - Intel Xeon 5600 Series Processors
Page 4
...turbo mode is detected on DIMM XX memory module. Voltage: 1.5V or 1.35V This CPU power rating is not supported This message displays when either of the supported systems, see "Important Information". • The Intel Xeon X5677 130 W series quad-core processor is enabled in ...disabled in the turbo mode. Non-ECC DIMM detected Displays when the system detects a non-ECC on PowerEdge M610 and M710. Enabling Dell BIOS Intelligent Turbo Mode The Dell BIOS Intelligent Turbo Mode feature allows the operating system to set the processor performance in the processor system setup...
...turbo mode is detected on DIMM XX memory module. Voltage: 1.5V or 1.35V This CPU power rating is not supported This message displays when either of the supported systems, see "Important Information". • The Intel Xeon X5677 130 W series quad-core processor is enabled in ...disabled in the turbo mode. Non-ECC DIMM detected Displays when the system detects a non-ECC on PowerEdge M610 and M710. Enabling Dell BIOS Intelligent Turbo Mode The Dell BIOS Intelligent Turbo Mode feature allows the operating system to set the processor performance in the processor system setup...
Information Update - Intel Xeon 5600 Series Processors
Page 10
... CPU power rating is not supported Non-ECC DIMM detected on DIMM XX II Intel Xeon 5600 130 W • 在 PowerEdge M610 和 M710 Intel Xeon X5677 130 W ECC 启用 Dell BIOS 智能 Turbo 模式 Dell BIOS 智能 Turbo ...turbo turbo Processor Settings turbo BIOS turbo Dell BIOS 智能 Turbo 模式。...
... CPU power rating is not supported Non-ECC DIMM detected on DIMM XX II Intel Xeon 5600 130 W • 在 PowerEdge M610 和 M710 Intel Xeon X5677 130 W ECC 启用 Dell BIOS 智能 Turbo 模式 Dell BIOS 智能 Turbo ...turbo turbo Processor Settings turbo BIOS turbo Dell BIOS 智能 Turbo 模式。...
Information Update - Intel Xeon 5600 Series Processors
Page 30
Hardware Prefetcher Enabled DCU Streamer Prefetcher (DCU Enabled Data Reuse Enabled DCU HPC HPC POST Intel Xeon 5600 POST 説明 System Memory Size X.X GB, System Memory Speed: XXX MHz, ます。 Voltage: 1.5V or 1.35V This CPU power rating is not supported Non-ECC DIMM detected on DIMM XX Intel Xeon 5600 130 W II • PowerEdge M610/M710 で Intel Xeon X5677 130 W 非 ECC
Hardware Prefetcher Enabled DCU Streamer Prefetcher (DCU Enabled Data Reuse Enabled DCU HPC HPC POST Intel Xeon 5600 POST 説明 System Memory Size X.X GB, System Memory Speed: XXX MHz, ます。 Voltage: 1.5V or 1.35V This CPU power rating is not supported Non-ECC DIMM detected on DIMM XX Intel Xeon 5600 130 W II • PowerEdge M610/M710 で Intel Xeon X5677 130 W 非 ECC
Information Update - Intel Xeon 5600 Series Processors
Page 36
옵션 Data Reuse Enabled(활성화)) 설명 HPC 새 POST 메시지 다음은 Intel Xeon 5600 POST 메시지 설명 System Memory Size X.X GB, System Memory Speed: XXX MHz, Voltage: 1.5V or 1.35V This CPU power rating is not supported Non-ECC DIMM detected on DIMM XX II Intel Xeon 5600 130W • PowerEdge M610 및 M710 에서 Intel Xeon X5677 130W ECC
옵션 Data Reuse Enabled(활성화)) 설명 HPC 새 POST 메시지 다음은 Intel Xeon 5600 POST 메시지 설명 System Memory Size X.X GB, System Memory Speed: XXX MHz, Voltage: 1.5V or 1.35V This CPU power rating is not supported Non-ECC DIMM detected on DIMM XX II Intel Xeon 5600 130W • PowerEdge M610 및 M710 에서 Intel Xeon X5677 130W ECC
Information Update
Page 1
...on the Microsoft Help and Support website at support.microsoft.com: • Systems running Windows Server 2008 do not support iSCSI boot when they have been removed. Flash Memory The VFlash media provided by Microsoft. NOTE: On Dell PowerEdge R610 and PowerEdge R710 systems, the labels are located... on the information panel on the front of the system. For more information, see the knowledge base article at support.microsoft.com/kb/888575. • Systems running ...
...on the Microsoft Help and Support website at support.microsoft.com: • Systems running Windows Server 2008 do not support iSCSI boot when they have been removed. Flash Memory The VFlash media provided by Microsoft. NOTE: On Dell PowerEdge R610 and PowerEdge R710 systems, the labels are located... on the information panel on the front of the system. For more information, see the knowledge base article at support.microsoft.com/kb/888575. • Systems running ...
Information Update
Page 3
.../888575 Windows Server 2008 SD SD iSCSI USB iSCSI Microsoft support.microsoft.com/kb/968410。 Dell 提供的 VFlash iDRAC6 Enterprise iDRAC GUI Unified Server Configurator Red Hat® Enterprise Linux® 5.3 Unified Server Configurator MAC NIC 和 iDRAC6 Enterprise MAC 注:在 Dell PowerEdge R610 和 PowerEdge R710 PowerEdge T610 2009 年 3 月
.../888575 Windows Server 2008 SD SD iSCSI USB iSCSI Microsoft support.microsoft.com/kb/968410。 Dell 提供的 VFlash iDRAC6 Enterprise iDRAC GUI Unified Server Configurator Red Hat® Enterprise Linux® 5.3 Unified Server Configurator MAC NIC 和 iDRAC6 Enterprise MAC 注:在 Dell PowerEdge R610 和 PowerEdge R710 PowerEdge T610 2009 年 3 月