Instruction Manual
Page 10
...becomes steady on . For connecting to a DC 12 V or AC 24 V, 50 Hz/ era in use, check the camera and/or the network equipment. & [MONITOR OUT] terminal For connecting to reset VN-C11. When the camera is in a way that does not cover the opening # [DC 12 V/AC 24 V] Power terminal For ...the internal cooling fan. If the indicator blinks while the camera is ready for 2 ...
...becomes steady on . For connecting to a DC 12 V or AC 24 V, 50 Hz/ era in use, check the camera and/or the network equipment. & [MONITOR OUT] terminal For connecting to reset VN-C11. When the camera is in a way that does not cover the opening # [DC 12 V/AC 24 V] Power terminal For ...the internal cooling fan. If the indicator blinks while the camera is ready for 2 ...
Instruction Manual
Page 13
...Length (a) C-mount lens 17.526mm 10 mm max. Attach the lens to the camera securely by turn the back-focus adjustment ring to the socket while examining the pin arrangement. 13 4 2 4-Pin Plug Pin No. VN-C11 is set for CS-mount at the factory. Do not use a lens with... a finger or a pointed tool like a screwdriver. Lens 1 2 3 4 DC IRIS Lens (Without a built-in the following procedure. (a) F 1. Before attaching a lens, check the mount method of a DC IRIS lens, connect the lens cable to change the mount method accordingly with a length longer than (a) as...
...Length (a) C-mount lens 17.526mm 10 mm max. Attach the lens to the camera securely by turn the back-focus adjustment ring to the socket while examining the pin arrangement. 13 4 2 4-Pin Plug Pin No. VN-C11 is set for CS-mount at the factory. Do not use a lens with... a finger or a pointed tool like a screwdriver. Lens 1 2 3 4 DC IRIS Lens (Without a built-in the following procedure. (a) F 1. Before attaching a lens, check the mount method of a DC IRIS lens, connect the lens cable to change the mount method accordingly with a length longer than (a) as...
Instruction Manual
Page 14
... set to 2-4 Other Settings with multiple VN-C11s In a system where more than one VN-C11 are correctly oriented. • For DC 12 V connection, the ripple voltage should not exceed 50 mV. Preparations (Step 1 Connection and Installation) 1-2 Connecting the Power Cord Connect the camera to 2-4. For a system with V.Networks Setup Tool. Note The IP address...
... set to 2-4 Other Settings with multiple VN-C11s In a system where more than one VN-C11 are correctly oriented. • For DC 12 V connection, the ripple voltage should not exceed 50 mV. Preparations (Step 1 Connection and Installation) 1-2 Connecting the Power Cord Connect the camera to 2-4. For a system with V.Networks Setup Tool. Note The IP address...
Instruction Manual
Page 17
..., lamp, LED etc. 17 Output Requirements • Equivalent to NPN open collector output (The output logic is set with [V.Networks Setup Tool.]) • Allowed applied voltage: DC 12 V max. • Allowed input current: 300 mA • Momentary output: 2 to the one of the annunciator.... 1-4 Connecting the Alarm I/O Terminals (continued) Alarm Output Terminal This terminal is for connecting with [V.Networks Setup Tool.]) Caution Connect the VN-C11 grounding ...
..., lamp, LED etc. 17 Output Requirements • Equivalent to NPN open collector output (The output logic is set with [V.Networks Setup Tool.]) • Allowed applied voltage: DC 12 V max. • Allowed input current: 300 mA • Momentary output: 2 to the one of the annunciator.... 1-4 Connecting the Alarm I/O Terminals (continued) Alarm Output Terminal This terminal is for connecting with [V.Networks Setup Tool.]) Caution Connect the VN-C11 grounding ...
Instruction Manual
Page 49
... there is 50 Hz. 4 Saturation Adjusts color saturation. A lower AGC : Automatically adjusts the gain in the background of the object, VN-C11 adjusts the weighted zone. speed in accordance with the brightness. Only for a manual iris lens. 2 White Balance BLC Auto : ...Automatically adjusts the white balance, the standard for a DC IRIS lens. quality. Factory set at the factory. 7 Iris level Brightness adjustment for color saturation. Value range: 0 to100 3 Shutter Speed 1/60...
... there is 50 Hz. 4 Saturation Adjusts color saturation. A lower AGC : Automatically adjusts the gain in the background of the object, VN-C11 adjusts the weighted zone. speed in accordance with the brightness. Only for a manual iris lens. 2 White Balance BLC Auto : ...Automatically adjusts the white balance, the standard for a DC IRIS lens. quality. Factory set at the factory. 7 Iris level Brightness adjustment for color saturation. Value range: 0 to100 3 Shutter Speed 1/60...
Instruction Manual
Page 68
Effect Sets the compression rate for a DC IRIS lens. A smaller rate means better image quality, but with more blue .... A smaller value makes images darker, closing the iris. AES : Automatically adjusts the shutter speed in the background of VN-C11.) Item Compression Rate Saturation White Balance Auto R gain B gain AGC, AES, BLC Shutter Speed Iris level 68 ... Settings) Image Quality Setting Window: http://******/configimage-e.html (****** represents the URL of the object, VN-C11 adjusts the weighted zone. 1/60 : Normal factory set speed. 1/100 : This reduces image flickers due to the ...
Effect Sets the compression rate for a DC IRIS lens. A smaller rate means better image quality, but with more blue .... A smaller value makes images darker, closing the iris. AES : Automatically adjusts the shutter speed in the background of VN-C11.) Item Compression Rate Saturation White Balance Auto R gain B gain AGC, AES, BLC Shutter Speed Iris level 68 ... Settings) Image Quality Setting Window: http://******/configimage-e.html (****** represents the URL of the object, VN-C11 adjusts the weighted zone. 1/60 : Normal factory set speed. 1/100 : This reduces image flickers due to the ...
Instruction Manual
Page 77
...Monitor output Image pickup device Available pixels Video S/N ratio Minimum required illumination Image compression Output image format Lens mount Alarm input Alarm output Network interfaces Internal memory Power supply voltage Power consumption Operating temperature Mass External Dimensions (Unit: mm) 70 IEEE802.3, IEEE802.3u TCP/IP, .... NPN open collector output (allowable impressed voltage: 12 V, allowable input current: 300 mA) RJ-45 (Category 5) 10BASE-T/100BASE-TX (Auto-Negotiation) 8 MB DC 12 V or AC 24 V, 50 Hz/60 Hz 1.2 A max. 0 °C to 40 °C Approx. 560 g U1-32 148 138 64.5...
...Monitor output Image pickup device Available pixels Video S/N ratio Minimum required illumination Image compression Output image format Lens mount Alarm input Alarm output Network interfaces Internal memory Power supply voltage Power consumption Operating temperature Mass External Dimensions (Unit: mm) 70 IEEE802.3, IEEE802.3u TCP/IP, .... NPN open collector output (allowable impressed voltage: 12 V, allowable input current: 300 mA) RJ-45 (Category 5) 10BASE-T/100BASE-TX (Auto-Negotiation) 8 MB DC 12 V or AC 24 V, 50 Hz/60 Hz 1.2 A max. 0 °C to 40 °C Approx. 560 g U1-32 148 138 64.5...