FTOS Command Reference Guide
Page 108
... for S-Series is chassis dependent. Enter the keyword fan to display fan speeds instead of this command is changed to view information on power entry modules. Power Supplies -- www.dell.com | support.dell.com FanNumber 0 1 2 3 4 5 FTOS# Speed 4170 4140 3870 4140 3870 3810 Status up up up up up up show environment [all | fan | stack...
... for S-Series is chassis dependent. Enter the keyword fan to display fan speeds instead of this command is changed to view information on power entry modules. Power Supplies -- www.dell.com | support.dell.com FanNumber 0 1 2 3 4 5 FTOS# Speed 4170 4140 3870 4140 3870 3810 Status up up up up up up show environment [all | fan | stack...
FTOS Command Reference Guide
Page 109
... removed from output of show inventory (C-Series and E-Series) c e Display the chassis type, components (including media), FTOS version including hardware identification numbers and configured protocols. Power Supplies -- Introduced on E-Series ExaScale Output expanded to include transceiver media Control and Monitoring | 109 Unit Status Temp Voltage 0* online 49C ok * Management Unit show inventory...
... removed from output of show inventory (C-Series and E-Series) c e Display the chassis type, components (including media), FTOS version including hardware identification numbers and configured protocols. Power Supplies -- Introduced on E-Series ExaScale Output expanded to include transceiver media Control and Monitoring | 109 Unit Status Temp Voltage 0* online 49C ok * Management Unit show inventory...
FTOS Command Reference Guide
Page 115
... line card in the line card. This field does not state whether the chassis is operating in the chassis: • AC = AC power supply • DC = DC Power Entry Module (PEM) Displays OK if the line voltage is within range. The [Booted] keyword next to the version states which specifies the ... on a specific line card. Syntax show linecard output Field Num Ports Up Time FTOS Version Jumbo Capable Boot Flash Ver Memory Size Temperature Power Status Voltage Serial Number Part Num Vendor ID Date Code Description Displays the number of the line card processor. Displays the number of the ...
... line card in the line card. This field does not state whether the chassis is operating in the chassis: • AC = AC power supply • DC = DC Power Entry Module (PEM) Displays OK if the line voltage is within range. The [Booted] keyword next to the version states which specifies the ... on a specific line card. Syntax show linecard output Field Num Ports Up Time FTOS Version Jumbo Capable Boot Flash Ver Memory Size Temperature Power Status Voltage Serial Number Part Num Vendor ID Date Code Description Displays the number of the line card processor. Displays the number of the ...
FTOS Command Reference Guide
Page 135
... Flash versions for the Routing Processor 2. C-Series possible values: • "normal power-cycle" (reset power-cycle command) • "reset by master" (peer RPM reset by master RPM) • "over temperature shutdown" • "power supply failed" E-Series possible values: • "normal power-cycle" (insufficient power, normal power cycle) • "reset by user" (automatic failover, software reload of show...
... Flash versions for the Routing Processor 2. C-Series possible values: • "normal power-cycle" (reset power-cycle command) • "reset by master" (peer RPM reset by master RPM) • "over temperature shutdown" • "power supply failed" E-Series possible values: • "normal power-cycle" (insufficient power, normal power cycle) • "reset by user" (automatic failover, software reload of show...
FTOS Command Reference Guide
Page 139
... Jumbo Capable : yes POE Capable : no FIPS Mode : disabled Stack MAC : 00:01:e8:8b:3e:42 Reload-Type : normal-reload [Next boot : normal-reload] -- Power Supplies -- Fan Status -Unit Bay TrayStatus Fan0 Speed Fan1 Speed Control and Monitoring | 139 Introduced for boot code 2.8.1.1 and newer, while older boot codes are displayed...
... Jumbo Capable : yes POE Capable : no FIPS Mode : disabled Stack MAC : 00:01:e8:8b:3e:42 Reload-Type : normal-reload [Next boot : normal-reload] -- Power Supplies -- Fan Status -Unit Bay TrayStatus Fan0 Speed Fan1 Speed Control and Monitoring | 139 Introduced for boot code 2.8.1.1 and newer, while older boot codes are displayed...
FTOS Command Reference Guide
Page 140
www.dell.com | support.dell.com Example (show system brief) 0 0 up 0 1 up up 6720 up 6960 up 6720 up 6960 Speed in RPM FTOS # FTOS#show system brief Stack MAC : 0:1:e8:d6:4:70 -- Power Supplies -- Stack Info -- Power Supplies -- Unit UnitType Status ReqTyp CurTyp Version Ports 0 Member not present 1 Standby online S50V S50V 7.7.1.0 52 2 Mgmt online S50V...
www.dell.com | support.dell.com Example (show system brief) 0 0 up 0 1 up up 6720 up 6960 up 6720 up 6960 Speed in RPM FTOS # FTOS#show system brief Stack MAC : 0:1:e8:d6:4:70 -- Power Supplies -- Stack Info -- Power Supplies -- Unit UnitType Status ReqTyp CurTyp Version Ports 0 Member not present 1 Standby online S50V S50V 7.7.1.0 52 2 Mgmt online S50V...
FTOS Command Reference Guide
Page 141
...-10GE-2C Num Ports : 2 Hot Pluggable : no : Present : 254701568 bytes : 43C : ok : DZ267160000 : 7590003600 Rev B : 07 : 12172007 : 01 : 00:01:e8:cc:cc:cc : 3 --Module 0-- Power Supplies -- Display information about the stack ports on running processes. Fan Status Unit TrayStatus Fan0 Fan1 Fan2 Fan3 Fan4 Fan5 0 up FTOS# up up up up...
...-10GE-2C Num Ports : 2 Hot Pluggable : no : Present : 254701568 bytes : 43C : ok : DZ267160000 : 7590003600 Rev B : 07 : 12172007 : 01 : 00:01:e8:cc:cc:cc : 3 --Module 0-- Power Supplies -- Display information about the stack ports on running processes. Fan Status Unit TrayStatus Fan0 Fan1 Fan2 Fan3 Fan4 Fan5 0 up FTOS# up up up up...
FTOS Command Reference Guide
Page 1575
... alarm: problem with power entry module %s CHM_PWRSRC_CLR ENVMON SUPPLY %CHMGR-5-PEM_OK: Major alarm cleared: power entry module %s is good CHM_MAJ_ALARM_PS ENVMON SUPPLY %CHMGR-0-MAJOR_PS: Major alarm: insufficient power %s CHM_MAJ_ALARM_PS_CLR ENVMON SUPPLY %CHMGR-5-MAJOR_PS_CLR: major alarm cleared: sufficient power CHM_MIN_ALARM_PS ENVMON SUPPLY %CHMGR-1-MINOR_PS: Minor alarm: power supply non-redundant CHM_MIN_ALARM_PS_CLR ENVMON SUPPLY %CHMGR-5-MINOR_PS_CLR: Minor alarm cleared: power supply redundant CHM_MIN_ALRM_TEMP ENVMON TEMP...
... alarm: problem with power entry module %s CHM_PWRSRC_CLR ENVMON SUPPLY %CHMGR-5-PEM_OK: Major alarm cleared: power entry module %s is good CHM_MAJ_ALARM_PS ENVMON SUPPLY %CHMGR-0-MAJOR_PS: Major alarm: insufficient power %s CHM_MAJ_ALARM_PS_CLR ENVMON SUPPLY %CHMGR-5-MAJOR_PS_CLR: major alarm cleared: sufficient power CHM_MIN_ALARM_PS ENVMON SUPPLY %CHMGR-1-MINOR_PS: Minor alarm: power supply non-redundant CHM_MIN_ALARM_PS_CLR ENVMON SUPPLY %CHMGR-5-MINOR_PS_CLR: Minor alarm cleared: power supply redundant CHM_MIN_ALRM_TEMP ENVMON TEMP...
Getting Started Guide
Page 3
Contents 1 About this Guide 1 2 Introduction 3 Product Description 3 3 Hardware Overview 5 Fans 6 Front Panel 7 System Status 8 4 Installation 11 Unpacking the Switch 11 Package Contents 11 Unpacking Steps 11 Power Supplies 12 Install an AC or DC Power Supply 13 Rack Mounting the Switch 14 Rack Mounting Safety Considerations 14 Installing the Dell ReadyRails System 15 Installing the Switch 19 5 Technical Specifications 21 Chassis Physical Design 21 Environmental Parameters 21 Power Requirements 22 DC Input Specification 22 Contents 1
Contents 1 About this Guide 1 2 Introduction 3 Product Description 3 3 Hardware Overview 5 Fans 6 Front Panel 7 System Status 8 4 Installation 11 Unpacking the Switch 11 Package Contents 11 Unpacking Steps 11 Power Supplies 12 Install an AC or DC Power Supply 13 Rack Mounting the Switch 14 Rack Mounting Safety Considerations 14 Installing the Dell ReadyRails System 15 Installing the Switch 19 5 Technical Specifications 21 Chassis Physical Design 21 Environmental Parameters 21 Power Requirements 22 DC Input Specification 22 Contents 1
Getting Started Guide
Page 11
...) • Software-readable thermal monitor • Real time clock (RTC) support • Hot-plugging redundant power supply • Current monitoring for Power management • Removable fan that you can manage • Standard 1U chassis high Hardware Overview 5 The S4820T has the following features: • Supports one universal serial bus (USB) port • Forty-eight...
...) • Software-readable thermal monitor • Real time clock (RTC) support • Hot-plugging redundant power supply • Current monitoring for Power management • Removable fan that you can manage • Standard 1U chassis high Hardware Overview 5 The S4820T has the following features: • Supports one universal serial bus (USB) port • Forty-eight...
Getting Started Guide
Page 12
...invalid configuration. Installation of the fans is designed to I/O All fans and PSUs in a configuration must be installed at the customer site (refer to Power Supplies). • AC PSU with fan airflow from I/O to PSU • AC PSU with fan airflow from PSU to I/O • DC PSU ... PSU to notify you of the factory install based on SKU type. The power supply units (PSUs) are to be in the same airflow direction. S4820T Fan Modules Fan Module 0 Fan Module 1 Grab Handles 6 Hardware Overview Fans The S4820T has stock keeping units (SKUs) that support the following configurations.
...invalid configuration. Installation of the fans is designed to I/O All fans and PSUs in a configuration must be installed at the customer site (refer to Power Supplies). • AC PSU with fan airflow from I/O to PSU • AC PSU with fan airflow from PSU to I/O • DC PSU ... PSU to notify you of the factory install based on SKU type. The power supply units (PSUs) are to be in the same airflow direction. S4820T Fan Modules Fan Module 0 Fan Module 1 Grab Handles 6 Hardware Overview Fans The S4820T has stock keeping units (SKUs) that support the following configurations.
Getting Started Guide
Page 15
...S4820T system. System LED Displays Feature System LED TEMP LED DIAG LED FAN LED STACK LED LOCATOR LED Detailed Description Comment • Solid blue -Normal Operation I/O side • Blinking blue -Booting • Solid red -Critical system error • Blinking red -Noncritical system error (fan fail, power supply... fail) • Off: Normal temperature PSU side • Solid red -Overtemp (Refer NOTE:) • Off -Normal operating PSU side • Solid green -System Booting or Diagnostics • Solid green -fan powered PSU side and running at...
...S4820T system. System LED Displays Feature System LED TEMP LED DIAG LED FAN LED STACK LED LOCATOR LED Detailed Description Comment • Solid blue -Normal Operation I/O side • Blinking blue -Booting • Solid red -Critical system error • Blinking red -Noncritical system error (fan fail, power supply... fail) • Off: Normal temperature PSU side • Solid red -Overtemp (Refer NOTE:) • Off -Normal operating PSU side • Solid green -System Booting or Diagnostics • Solid green -fan powered PSU side and running at...
Getting Started Guide
Page 18
... PSU is grounded properly. Figure 1-4. Dell Force10 recommends using power supply 1 (PSU1) as the blank plate slot. Always wear an ESD-preventive wrist or heel ground strap when handling the S4820T and its components. The S4820T supports AC and DC power supplies with two air-flow directions (I /O). Power Supplies The S4820T supports two hot-swappable power supplies units (PSUs) and fans that provide...
... PSU is grounded properly. Figure 1-4. Dell Force10 recommends using power supply 1 (PSU1) as the blank plate slot. Always wear an ESD-preventive wrist or heel ground strap when handling the S4820T and its components. The S4820T supports AC and DC power supplies with two air-flow directions (I /O). Power Supplies The S4820T supports two hot-swappable power supplies units (PSUs) and fans that provide...
Getting Started Guide
Page 19
... 13 Dell Force10 recommends using the 2nd PSU slot on the left side of the PSU and the status LED is at the top of the two PSU slots may damage the PSU or the S4820T chassis. Step Task 1 Remove the PSU slot cover from the switch PSU to the external power source... (2nd PSU), repeat steps 1 through 5 above using power supply 1 (PSU1) as the cables are connected between the power supply and the power source. NOTE: The system powers up as soon as the blank plate slot. Install an AC or DC Power Supply To install an AC or DC power supply, follow these steps: NOTE: The PSU slides into a...
... 13 Dell Force10 recommends using the 2nd PSU slot on the left side of the PSU and the status LED is at the top of the two PSU slots may damage the PSU or the S4820T chassis. Step Task 1 Remove the PSU slot cover from the switch PSU to the external power source... (2nd PSU), repeat steps 1 through 5 above using power supply 1 (PSU1) as the cables are connected between the power supply and the power source. NOTE: The system powers up as soon as the blank plate slot. Install an AC or DC Power Supply To install an AC or DC power supply, follow these steps: NOTE: The PSU slides into a...
Getting Started Guide
Page 28
...5V/24A −48V/19.2A −60V/16.0A (with fan) 39.0+/−1.5V 37.5+/−1.5V 22 Technical Specifications Power Requirements Parameter Power supply Maximum current draw per system Maximum power consumption Reliability Specifications 100-240 VAC 50/60 Hz 4 A @ 398.02watts/100vac 2 A @ 398.02watts/200vac 398....02 Watts MTBF 355,178 hours NOTE: The table below represents the DC PSU's capabilities and does not represent the S4820T operation. DC Input Specification The power supply operates within all specified limits over the following input voltage range.
...5V/24A −48V/19.2A −60V/16.0A (with fan) 39.0+/−1.5V 37.5+/−1.5V 22 Technical Specifications Power Requirements Parameter Power supply Maximum current draw per system Maximum power consumption Reliability Specifications 100-240 VAC 50/60 Hz 4 A @ 398.02watts/100vac 2 A @ 398.02watts/200vac 398....02 Watts MTBF 355,178 hours NOTE: The table below represents the DC PSU's capabilities and does not represent the S4820T operation. DC Input Specification The power supply operates within all specified limits over the following input voltage range.
Installing the S4820T System
Page 3
...Selection 18 Cabinet Placement 18 Rack Mounting 18 Grounding 18 Fans and Airflow 18 Fan Combinations 19 Power 19 Storing Components 19 4 Installing the S4820T Unpacking the S4820T Switch 21 Package Contents 21 Unpacking Steps 22 Installing Rack or Cabinet Hardware 23 Rack Mounting ...Installing the Dell ReadyRails System 24 Two-post Flush-mount Configuration 25 Two-post Center-mount Configuration 26 Four-post Threaded Configuration 27 Installing the S4820T Switch 28 1U Front-rack Installation 28 Attaching the Ground Cable 28 Installing an AC or DC Power Supply 29 Installing ...
...Selection 18 Cabinet Placement 18 Rack Mounting 18 Grounding 18 Fans and Airflow 18 Fan Combinations 19 Power 19 Storing Components 19 4 Installing the S4820T Unpacking the S4820T Switch 21 Package Contents 21 Unpacking Steps 22 Installing Rack or Cabinet Hardware 23 Rack Mounting ...Installing the Dell ReadyRails System 24 Two-post Flush-mount Configuration 25 Two-post Center-mount Configuration 26 Four-post Threaded Configuration 27 Installing the S4820T Switch 28 1U Front-rack Installation 28 Attaching the Ground Cable 28 Installing an AC or DC Power Supply 29 Installing ...
Installing the S4820T System
Page 4
...-Stacking Points to Know 33 Connect Two S4820T Systems 34 Connect Three S4820T Systems 35 Hot-Swapping Units in a Stack 36 5 Power Supplies Components 39 Installing an AC or DC Power Supply 40 Replacing an AC or DC Power Supply 40 Connecting a DC Power Supply to the Power Source 41 Removing Power Connector from an S4820T DC Power Supply 42 6 Fans Components 43 Install a Fan...
...-Stacking Points to Know 33 Connect Two S4820T Systems 34 Connect Three S4820T Systems 35 Hot-Swapping Units in a Stack 36 5 Power Supplies Components 39 Installing an AC or DC Power Supply 40 Replacing an AC or DC Power Supply 40 Connecting a DC Power Supply to the Power Source 41 Removing Power Connector from an S4820T DC Power Supply 42 6 Fans Components 43 Install a Fan...
Installing the S4820T System
Page 9
... and four ports of -rack (ToR) switch/router product for purchase. The S4820T Power Supply Unit (PSU) side (Figure 2-1) contains the PSU, fan modules, and management ports. The S4820T Switch | 9 Figure 2-1. S4820T I /O) side (Figure 2-2) contains the 48 10Gbps RJ-45 auto-sensing ports... 40Gbps QSPFP+ ports, a Universal Serial Bus port (USB), and stacking identification LEDs. S4820T PSU-Side View Power Supply 0 Fan Module 0 Fan Module 1 Power Supply 1 Port Grab Handles Figure 2-2. The S4820T Input/Output (I /O-Side View 10GBase-T RJ-45 Ports USB (Type-A) Port QSFP+ ...
... and four ports of -rack (ToR) switch/router product for purchase. The S4820T Power Supply Unit (PSU) side (Figure 2-1) contains the PSU, fan modules, and management ports. The S4820T Switch | 9 Figure 2-1. S4820T I /O) side (Figure 2-2) contains the 48 10Gbps RJ-45 auto-sensing ports... 40Gbps QSPFP+ ports, a Universal Serial Bus port (USB), and stacking identification LEDs. S4820T PSU-Side View Power Supply 0 Fan Module 0 Fan Module 1 Power Supply 1 Port Grab Handles Figure 2-2. The S4820T Input/Output (I /O-Side View 10GBase-T RJ-45 Ports USB (Type-A) Port QSFP+ ...
Installing the S4820T System
Page 10
...to help transition a data center with multiple speed requirements. www.dell.com | support.dell.com The S4820T switch runs the Dell Force10 Operating System (FTOS), providing switching, bridging, and routing functionality for Power management • Removable fan that you can manage • ... (RTC) support • Hot-plugging redundant power supply • Current monitoring for transmitting data, storage, and server traffic. In a data center network, the S4820T switch provides converged network support and inter-operates with Dell and third-party ToR devices. The switch supports...
...to help transition a data center with multiple speed requirements. www.dell.com | support.dell.com The S4820T switch runs the Dell Force10 Operating System (FTOS), providing switching, bridging, and routing functionality for Power management • Removable fan that you can manage • ... (RTC) support • Hot-plugging redundant power supply • Current monitoring for transmitting data, storage, and server traffic. In a data center network, the S4820T switch provides converged network support and inter-operates with Dell and third-party ToR devices. The switch supports...
Installing the S4820T System
Page 12
www.dell.com | support.dell.com Table 2-1. Critical system error • Blinking red - System Booting ... blue - Link on 10Gbps speed • Solid Amber - Transmit/Receive is active 12 | The S4820T Switch fan powered and running at bottom of the thermal sensors exceeds this temperature, the TEMP LED turns RED. Link on...Displays Feature Detailed Description System LED • Solid blue - Booting • Solid red - Non-critical system error (fan fail, power supply fail) TEMP LED • Off: Normal temperature • Solid red - "Over-temp" (Refer to NOTE: at the expected ...
www.dell.com | support.dell.com Table 2-1. Critical system error • Blinking red - System Booting ... blue - Link on 10Gbps speed • Solid Amber - Transmit/Receive is active 12 | The S4820T Switch fan powered and running at bottom of the thermal sensors exceeds this temperature, the TEMP LED turns RED. Link on...Displays Feature Detailed Description System LED • Solid blue - Booting • Solid red - Non-critical system error (fan fail, power supply fail) TEMP LED • Off: Normal temperature • Solid red - "Over-temp" (Refer to NOTE: at the expected ...