Dell Force10 S25-01-GE-24V Support and Manuals

Get Help and Manuals for this Dell item

View All Support Options Below
Free Dell Force10 S25-01-GE-24V manuals!
Problems with Dell Force10 S25-01-GE-24V?

Ask a Question

Popular Dell Force10 S25-01-GE-24V Manual Pages

FTOS 8.4.2.6 Command Line Reference Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 83

..., the 2.4 setting has a lower latency. Dell Force10 recommends using the 10.4 setting when the system has 9 SFMs. Using 8 SFMs in an ExaScale chassis, the 10.4 and 2.4 settings are both line rate. The E-Series TeraScale E600/E600i and the E1200/E1200i systems support the 10.4 and the 3.2 epoch settings. Note: The E300 supports only the 10.4 epoch setting. Enter the...
FTOS 8.4.2.6 Command Line Reference Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 451

Parameters auto manual Enter auto to set a lock and then exit the CONFIGURATION mode and another user attempts to enter the CONFIGURATION mode while a lock is in place, the following message is generated: % Error: User "" on line console0 is in exclusive configuration mode If a user is already in CONFIGURATION mode when a lock is executed...
FTOS 8.4.2.6 Command Line Reference Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 454

...Force10# show configuration lock Configure exclusively locked by the following line: Line Line number User Type State Ip address : vty 0 : 2 : admin : AUTO : LOCKED : 10.11.9.97 Usage Information The type may be used to send the messages to that FTOS is in the output can be auto, manual...set to auto, FTOS automatically denies access to CONFIGURATION mode to manual....dell.com | support.dell....
FTOS 8.4.2.6 Command Line Reference Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1392

...and username. • With PAP authentication, the remote device must send a username/password set which must prove its identity before the FTOS sends Information traffic. The E-Series checks... chap to the E-Series with a username. www.dell.com | support.dell.com Syntax loopback {internal | line} To delete a loopback setting, use the no ppp authenticate. Command Modes INTERFACE ...
FTOS 8.4.2.6 Command Line Reference Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1499

... be taken in a card-problem state upon a Buffer Traffic Manager hardware error. Defaults None Command Mode CONFIGURATION Command History Version 8.2.1.0 Introduced hardware monitor mac e Configure the system to shut down all ports on -error port-shutdown Defaults None Command Mode CONFIGURATION Command History Version 8.2.1.0 Introduced hardware watchdog c Set the watchdog timer to...
FTOS 8.4.2.6 Command Line Reference Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1606

... fpc card-problem card-reset card-shutdown parity-correction Enter the keyword action-on-error to enable automatic parity corrections for the party-bus control switch on the IPC subsystem of a hardware error. clear hardware linecard Command Example Force10#clear hardware linecard 2 port-set 0 btm ingress errors Force10#clear hardware rpm 1 port-set 0 btm ingress errors Force10#clear hardware...
FTOS 8.4.2.6 Command Line Reference Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1660

www.dell.com | support.dell.com routing policies, apply 1081 run-cpu...service password-encryption 1287 service timestamps 101 service-class dynamic dot1p 1180 service-class dynamic dot1p (QoS) 1180, 1181 service-policy input 1201 service-policy output 1202 service-queue 1202 set (policy QoS) 1203 set as-path prepend (Route Map) 271 set automatic-tag (Route Map) 271 set comm-list (Route Map) 272 set...
FTOS 8.4.2.6 Configuraiton Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) Sytems - Page 527

...; This TLV is aligned with troubleshooting and configuration. To support IPv6, the Dell Force10 implementation of IS-IS performs the following tasks: • Advertise IPv6 information in the PDUs • Process IPv6 information received in the PDUs • Compute routes to IPv6 destinations • Download IPv6 routes to RTM for installing in the FIB •...
FTOS 8.4.2.6 Configuraiton Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) Sytems - Page 1222

... a manual power cycle. When reporting an RPM failover triggered by a loss of the IPC or IRC heartbeats, look for troubleshooting specific problems while working with Dell Force10 technical support staff... unresponsive. Hardware watchdog timer The hardware watchdog command automatically reboots an FTOS switch/router with a single RPM that is transitioning to three persistent files depending...
FTOS 8.4.2.7 Command Line Reference Guide for E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 454

... mode. Send messages to manual, the user on the listed VTY line must explicitly set the lock each time before entering CONFIGURATION mode. When set to auto, FTOS automatically denies...the configuration lock status. When set to one or all other users every time the user on the listed VTY line enters CONFIGURATION mode. www.dell.com | support.dell.com show configuration lock Defaults...
FTOS 8.4.2.7 Command Line Reference Guide for E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1560

...#clear hardware rpm 1 port-set 0 btm ingress errors FTOS#clear hardware rpm 0 port-set 0 btm ingress errors % Error: RPM 0 is not active. Enter the keyword card-reset to take an action upon a hardware error. Enter the keyword fpc to configure the system to reset a line card upon a line card hardware error. www.dell.com | support.dell.com Example Figure 65...
FTOS 8.4.2.7 Command Line Reference Guide for E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1614

www.dell.com | support.dell.com S sample-rate (FTSA command) 513 ...service password-encryption 1291 service timestamps 102 service-class dynamic dot1p 1184 service-class dynamic dot1p (QoS) 1184, 1185 service-policy input 1205 service-policy output 1206 service-queue 1206 set (policy QoS) 1207 set as-path prepend (Route Map) 278 set automatic-tag (Route Map) 278 set comm-list (Route Map) 279 set...
FTOS 8.4.2.7 Configuration Guide for E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 511

... and the first fragment of time manually. This TLV is included in the...setting a specific amount of an LSP. • The MT Intermediate Systems TLV appears for installing in the FIB • Accept external IPv6 information and advertise this information in the supported...support IPv6, the Dell Force10 implementation of all the Remaining Time values advertised by the neighbors) or by setting...
FTOS 8.4.2.7 Configuration Guide for E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1208

... for a filename with Dell Force10 technical support staff. Application or kernel core dump RP in privileged EXEC mode. All debug commands are entered in the CORE_DUMP_DIR - As described in the High Availability chapter, an RPM failover can be triggered by loss of the IPC or IRC heartbeats, look for troubleshooting specific problems while working with the...
Installing the S25N and S25V Systems - Page 50

.... In FTOS, use show tech-support.) • Console captures showing the error messages • Console captures showing the troubleshooting steps taken • Saved messages to access the serial number of the designated switch (unit = stack ID). Figure 31 Serial Numbers on Back of Chassis Labels (Part #, Serial #, Mac Address, Bar Code, FRU #) 1234567 1234567 1234567 fn00163s25P...

Dell Force10 S25-01-GE-24V Reviews

Do you have an experience with the Dell Force10 S25-01-GE-24V that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Dell yet.

Popular Dell Force10 S25-01-GE-24V Search Terms

The following terms are frequently used to search for Dell Force10 S25-01-GE-24V support:

Ask a New Question
Use the box below to post a new question about Dell Force10 S25-01-GE-24V.
Manuals / Documents
Download any of our Dell Force10 S25-01-GE-24V manuals for free!

We have the following 7 documents available for the Dell Force10 S25-01-GE-24V:
  • FTOS 8.4.2.6 Command Line Reference Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25)
  • FTOS 8.4.2.7 Command Line Reference Guide for E-Series TeraScale, C-Series, S-Series (S50/S25)
  • FTOS 8.4.2.6 Configuraiton Guide for the E-Series TeraScale, C-Series, S-Series (S50/S25) Sytems
  • FTOS 8.4.2.7 Configuration Guide for E-Series TeraScale, C-Series, S-Series (S50/S25)
  • Installing the S25N and S25V Systems
  • Quick Start Guide for the S25 System
  • S-Series Secure Management

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell Force10 S25-01-GE-24V manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell Force10 S25-01-GE-24V user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.