FTOS Command Reference Guide
Page 78
... (5 minutes) Defaults Disabled Command Modes CONFIGURATION Command History Version 8.3.10.0 Version 8.1.1.0 Deprecated command for S4820T only. Replaces the enable xfp-power-updates command. Range: 120 to 6000 seconds Default: 300 seconds (5 minutes) Disabled CONFIGURATION Version 8.3.19.0 Version 8.3.10.0 Replacement command for S4810 only. Introduced on temperature and power monitoring in the SNMP MIB. Parameters interval seconds Enter the keyword interval followed by the polling interval in seconds. Syntax Parameters Defaults Command Modes Command History Usage...
... (5 minutes) Defaults Disabled Command Modes CONFIGURATION Command History Version 8.3.10.0 Version 8.1.1.0 Deprecated command for S4820T only. Replaces the enable xfp-power-updates command. Range: 120 to 6000 seconds Default: 300 seconds (5 minutes) Disabled CONFIGURATION Version 8.3.19.0 Version 8.3.10.0 Replacement command for S4810 only. Introduced on temperature and power monitoring in the SNMP MIB. Parameters interval seconds Enter the keyword interval followed by the polling interval in seconds. Syntax Parameters Defaults Command Modes Command History Usage...
FTOS Command Reference Guide
Page 115
... card processor. Displays the line card part number. Display information on a specific line card. View information on all interfaces on all elements of power modules used at system boot. View information on the SFM. Displays the operating software version. Displays the line card's manufacturing date. Descriptions for the slot. Lists the type of the system. List the memory of the line card. show linecard boot-information Command Modes EXEC EXEC Privilege Control and Monitoring | 115 Syntax show linecard boot-information e View the line card status and boot...
... card processor. Displays the line card part number. Display information on a specific line card. View information on all interfaces on all elements of power modules used at system boot. View information on the SFM. Displays the operating software version. Displays the line card's manufacturing date. Descriptions for the slot. Lists the type of the system. List the memory of the line card. show linecard boot-information Command Modes EXEC EXEC Privilege Control and Monitoring | 115 Syntax show linecard boot-information e View the line card status and boot...
FTOS Command Reference Guide
Page 136
... power rails for the line card. Displays an internal code, which specifies the manufacturing vendor. View information on a line card. Enter the keyword ifagt followed by the number of the power modules in the chassis. Minor alarm status if temperature is over 65° C. Displays the line card serial number. Displays the line card part number. show rpm output Field Temperature Power Status Voltage Serial Num Part Num Vendor ID Date Code Country Code Description Displays the temperature of show software ifm c s Display interface management (IFM) data. Lists...
... power rails for the line card. Displays an internal code, which specifies the manufacturing vendor. View information on a line card. Enter the keyword ifagt followed by the number of the power modules in the chassis. Minor alarm status if temperature is over 65° C. Displays the line card serial number. Displays the line card part number. show rpm output Field Temperature Power Status Voltage Serial Num Part Num Vendor ID Date Code Country Code Description Displays the temperature of show software ifm c s Display interface management (IFM) data. Lists...
FTOS Command Reference Guide
Page 613
... line card. Configure a port channel. Use the ip address command to assign an IP address to the Management interface or a forwarding router. If two RPMs are installed in your system, use the show redundancy command to display which RPM is enabled by slot number (0-1) and port number zero (0). Clear FIB entries on a specified line card. Related Commands FTOS(conf-if-lo-1655)# interface interface null interface port-channel interface vlan Configure a physical interface. Z Syntax interface ManagementEthernet slot/port Parameters slot/port Enter the...
... line card. Configure a port channel. Use the ip address command to assign an IP address to the Management interface or a forwarding router. If two RPMs are installed in your system, use the show redundancy command to display which RPM is enabled by slot number (0-1) and port number zero (0). Clear FIB entries on a specified line card. Related Commands FTOS(conf-if-lo-1655)# interface interface null interface port-channel interface vlan Configure a physical interface. Z Syntax interface ManagementEthernet slot/port Parameters slot/port Enter the...
FTOS Command Reference Guide
Page 691
... urg bit • User Datagram Protocol udp In the case of the IP address in access-group option (Refer to compose the filter. Enter the mask of ambiguous access control list rules, the debug ip packet access-control command will be disabled. Not configured. Usage Information Use the count option to stop packets from an interface, use the no ip address [ip-address] command. The access-group option supports only...
... urg bit • User Datagram Protocol udp In the case of the IP address in access-group option (Refer to compose the filter. Enter the mask of ambiguous access control list rules, the debug ip packet access-control command will be disabled. Not configured. Usage Information Use the count option to stop packets from an interface, use the no ip address [ip-address] command. The access-group option supports only...
FTOS Command Reference Guide
Page 983
... return to use the no default vlan disable is not listed in the running-configuration, but when the default VLAN is disabled, default-vlan disable is enabled. Command History Usage Information Related Commands Version 8.3.19.0 Version 8.3.7.0 Version 7.6.1.0 Version 7.5.1.0 pre-Version 6.2.1.1 Introduced on S4820T. VLAN counters are disabled in hardware (all switchports are placed in restricted mode to the default (disabled), use this command syntax (default-vlan-id 1). default-vlan disable c e s Disable the default VLAN so that all linecards/port-pipes) by default. You...
... return to use the no default vlan disable is not listed in the running-configuration, but when the default VLAN is disabled, default-vlan disable is enabled. Command History Usage Information Related Commands Version 8.3.19.0 Version 8.3.7.0 Version 7.6.1.0 Version 7.5.1.0 pre-Version 6.2.1.1 Introduced on S4820T. VLAN counters are disabled in hardware (all switchports are placed in restricted mode to the default (disabled), use this command syntax (default-vlan-id 1). default-vlan disable c e s Disable the default VLAN so that all linecards/port-pipes) by default. You...
FTOS Command Reference Guide
Page 1412
...EXEC Privilege Command History Usage Information Version 8.3.19.0 Version 8.3.11.1 Version 8.3.7.0 Version 7.6.1.0 Version 7.5.1.0 Introduced on S4820T Introduced on Z9000 Introduced on each group. Syntax Command Modes show snmp user User name: v1v2creadu Engine ID: 0000178B02000001E80214A8 storage-type: nonvolatile active Authentication Protocol: None Privacy Protocol: None FTOS# 1412 | Simple Network Management Protocol and Syslog www.dell.com | support.dell.com show snmp group c e s z Display the group name, security model, status, and storage type of version 3 (v3) with...
...EXEC Privilege Command History Usage Information Version 8.3.19.0 Version 8.3.11.1 Version 8.3.7.0 Version 7.6.1.0 Version 7.5.1.0 Introduced on S4820T Introduced on Z9000 Introduced on each group. Syntax Command Modes show snmp user User name: v1v2creadu Engine ID: 0000178B02000001E80214A8 storage-type: nonvolatile active Authentication Protocol: None Privacy Protocol: None FTOS# 1412 | Simple Network Management Protocol and Syslog www.dell.com | support.dell.com show snmp group c e s z Display the group name, security model, status, and storage type of version 3 (v3) with...
FTOS Command Reference Guide
Page 1422
... using the snmp-server community command prior to using this user with access rights. 4. Use the snmp-server enable command to specify which SNMP notifications are sent. Configuring Informs To send an inform, follow the step below. Configure a remote user. 3. Configure a host to 55 characters long. 1422 | Simple Network Management Protocol and Syslog Related Commands 1. Syntax snmp-server location text To delete the SNMP location, enter no notifications are sent globally. You can specify multiple notification types...
... using the snmp-server community command prior to using this user with access rights. 4. Use the snmp-server enable command to specify which SNMP notifications are sent. Configuring Informs To send an inform, follow the step below. Configure a remote user. 3. Configure a host to 55 characters long. 1422 | Simple Network Management Protocol and Syslog Related Commands 1. Syntax snmp-server location text To delete the SNMP location, enter no notifications are sent globally. You can specify multiple notification types...
FTOS Command Reference Guide
Page 1501
... Failure Detection (UFD) | 1501 downstream uplink-state-group Assign a port or port-channel to be disabled if one upstream interface in an uplink-state group goes down. Brings down by UFD. UPLINK-STATE-GROUP Version 8.3.19.0 Version 8.3.12.0 Version 8.4.2.3 Introduced on S4820T Introduced on S4810 Introduced on the S-Series S50. To disable auto-recovery on downstream links, enter the no downstream disable links command. A user-configurable number of upstream links...
... Failure Detection (UFD) | 1501 downstream uplink-state-group Assign a port or port-channel to be disabled if one upstream interface in an uplink-state group goes down. Brings down by UFD. UPLINK-STATE-GROUP Version 8.3.19.0 Version 8.3.12.0 Version 8.4.2.3 Introduced on S4820T Introduced on S4810 Introduced on the S-Series S50. To disable auto-recovery on downstream links, enter the no downstream disable links command. A user-configurable number of upstream links...
Getting Started Guide
Page 11
... inches (W x D x H). The S4820T has a chassis design with large memory, P2020/128 MB NOR Flash/2GB DDR III RAM. • Temperature monitoring (TMP75) • Software-readable thermal monitor • Real time clock (RTC) support • Hot-plugging redundant power supply • Current monitoring for the S4820T switch. Hardware Overview This section contains information about device characteristics and modular hardware configurations for Power management • Removable fan that you can manage • Standard 1U chassis high Hardware Overview 5
... inches (W x D x H). The S4820T has a chassis design with large memory, P2020/128 MB NOR Flash/2GB DDR III RAM. • Temperature monitoring (TMP75) • Software-readable thermal monitor • Real time clock (RTC) support • Hot-plugging redundant power supply • Current monitoring for the S4820T switch. Hardware Overview This section contains information about device characteristics and modular hardware configurations for Power management • Removable fan that you can manage • Standard 1U chassis high Hardware Overview 5
Installing the S4820T System
Page 30
... soon as the cables are connected between the power supply and the power source. 30 | Installing the S4820T www.dell.com | support.dell.com 1 Remove the PSU slot cover from the S4820T (PSU side of switch), either AC wall outlet or DC rack bus bar). 5 If you have a redundant PSU (2nd PSU), repeat steps 1 through 5 above using the 2nd PSU slot on the S4820T switch. The PSU slot is installed correctly it should...
... soon as the cables are connected between the power supply and the power source. 30 | Installing the S4820T www.dell.com | support.dell.com 1 Remove the PSU slot cover from the S4820T (PSU side of switch), either AC wall outlet or DC rack bus bar). 5 If you have a redundant PSU (2nd PSU), repeat steps 1 through 5 above using the 2nd PSU slot on the S4820T switch. The PSU slot is installed correctly it should...
Installing the S4820T System
Page 40
... the PSU or the S4820T chassis. To ensure sufficient room, Dell Force10 recommends using power supply 1 (PSU1) as the blank plate slot 40 | Power Supplies NOTE: To comply with the GR-1089 Lightning Criteria for Equipment Interfacing with AC Power Ports, use an external SPD at the top of the router. Installing an AC or DC Power Supply To install an AC or DC power supply, follow these steps: NOTE...
... the PSU or the S4820T chassis. To ensure sufficient room, Dell Force10 recommends using power supply 1 (PSU1) as the blank plate slot 40 | Power Supplies NOTE: To comply with the GR-1089 Lightning Criteria for Equipment Interfacing with AC Power Ports, use an external SPD at the top of the router. Installing an AC or DC Power Supply To install an AC or DC power supply, follow these steps: NOTE...
S4820T Configuration Guide
Page 254
... configuration file stored in the local flash. The reload settings that the Management IP and Management Interface be used (disable). • dhcp-timeout: The amount of time the switch waits for a user-configured time (DHCP timeout). www.dell.com | support.dell.com Restrictions BMP 2.0 is set with the reload-type jump-start EXEC Privilege Reload a switch running BMP version 2.0 in either Normal or Jumpstart mode. This mode is supported on the ports for a DHCP server...
... configuration file stored in the local flash. The reload settings that the Management IP and Management Interface be used (disable). • dhcp-timeout: The amount of time the switch waits for a user-configured time (DHCP timeout). www.dell.com | support.dell.com Restrictions BMP 2.0 is set with the reload-type jump-start EXEC Privilege Reload a switch running BMP version 2.0 in either Normal or Jumpstart mode. This mode is supported on the ports for a DHCP server...
S4820T Configuration Guide
Page 316
... in CONFIGURATION versus INTERFACE Configurations in a manual role. www.dell.com | support.dell.com DCBx Prerequisites and Restrictions The following prerequisites and restrictions apply when you must: 1. and FCF-facing interfaces as auto-downstream ports. 3. it does not support iSCSI, backward congestion management (BCN), logical link down . • The CIN version of DCBx supports only PFC, ETS, and FCOE; Command interface type slot/port [no] protocol lldp Command Mode CONFIGURATION INTERFACE 316 | Data Center...
... in CONFIGURATION versus INTERFACE Configurations in a manual role. www.dell.com | support.dell.com DCBx Prerequisites and Restrictions The following prerequisites and restrictions apply when you must: 1. and FCF-facing interfaces as auto-downstream ports. 3. it does not support iSCSI, backward congestion management (BCN), logical link down . • The CIN version of DCBx supports only PFC, ETS, and FCOE; Command interface type slot/port [no] protocol lldp Command Mode CONFIGURATION INTERFACE 316 | Data Center...
S4820T Configuration Guide
Page 820
... not RADIUS authorization is configured for login authentication. In FTOS, AAA uses a list of authentication methods, called method lists, to define the types of all user authentication and network service access information. Note: If a console user logs in which you can specify the security protocol or mechanism for terminal lines You can define a method list or use the default method list. Dell Force10 uses local usernames/passwords (stored on page...
... not RADIUS authorization is configured for login authentication. In FTOS, AAA uses a list of authentication methods, called method lists, to define the types of all user authentication and network service access information. Note: If a console user logs in which you can specify the security protocol or mechanism for terminal lines You can define a method list or use the default method list. Dell Force10 uses local usernames/passwords (stored on page...
S4820T Configuration Guide
Page 894
.... %SPANMGR-5-MSTP_TOPOLOGY_CHANGE: Topology change BridgeAddr: 0001.e801.fc35 Mstp Instance Id 0 port Gi 11/38 transitioned from Forwarding to Blocking state. %SPANMGR-5-MSTP_NEW_ROOT_BRIDGE: Elected root bridge for instance 0. Dell Force10 Enterprise-specific SNMP Traps Command Option envmon supply envmon temperature envmon fan vlt vrrp xstp ecfm entity Trap PEM_PRBLM: Major alarm: problem with power entry module %s PEM_OK: Major alarm cleared: power entry module %s is good MAJOR_PS...
.... %SPANMGR-5-MSTP_TOPOLOGY_CHANGE: Topology change BridgeAddr: 0001.e801.fc35 Mstp Instance Id 0 port Gi 11/38 transitioned from Forwarding to Blocking state. %SPANMGR-5-MSTP_NEW_ROOT_BRIDGE: Elected root bridge for instance 0. Dell Force10 Enterprise-specific SNMP Traps Command Option envmon supply envmon temperature envmon fan vlt vrrp xstp ecfm entity Trap PEM_PRBLM: Major alarm: problem with power entry module %s PEM_OK: Major alarm cleared: power entry module %s is good MAJOR_PS...
S4820T Configuration Guide
Page 936
.... Fan Status -- Unit Bay TrayStatus Fan0 Speed Fan1 Speed 1 0 up up 7200 up 7200 1 1 up up 7200 up stack-2# 936 | Stacking Power Supplies -- Unit Bay Status Type FanStatus Unit Bay Status Type FanStatus 1 0 absent absent 1 1 up AC up -- www.dell.com | support.dell.com Up Time FTOS Version Jumbo Capable POE Capable Boot Flash Memory Size Temperature Voltage Serial Number Part Number Vendor Id Date Code Country Code Piece Part ID PPID Revision Service Tag Expr Svc Code...
.... Fan Status -- Unit Bay TrayStatus Fan0 Speed Fan1 Speed 1 0 up up 7200 up 7200 1 1 up up 7200 up stack-2# 936 | Stacking Power Supplies -- Unit Bay Status Type FanStatus Unit Bay Status Type FanStatus 1 0 absent absent 1 1 up AC up -- www.dell.com | support.dell.com Up Time FTOS Version Jumbo Capable POE Capable Boot Flash Memory Size Temperature Voltage Serial Number Part Number Vendor Id Date Code Country Code Piece Part ID PPID Revision Service Tag Expr Svc Code...
S4820T Configuration Guide
Page 1010
... version in use the show vlt brief command on each VLT peer switch with independent control and data planes for devices attached on non-VLT ports. • One chassis in the VLT domain is required; You do not need to manually select VLANs. • VLT peer switches operate as a single logical device to network access devices connected to the lowest MAC address. www.dell.com | support.dell.com • If the DHCP server...
... version in use the show vlt brief command on each VLT peer switch with independent control and data planes for devices attached on non-VLT ports. • One chassis in the VLT domain is required; You do not need to manually select VLANs. • VLT peer switches operate as a single logical device to network access devices connected to the lowest MAC address. www.dell.com | support.dell.com • If the DHCP server...
S4820T Configuration Guide
Page 1018
... default VLT settings, such as a topology change. www.dell.com | support.dell.com Sample RSTP Configuration Using Figure 53-1 as a sample VLT topology, the primary VLT switch will send BPDUs to an access device (switch or server) with the primary switch. BPDUs generated by an RSTP-enabled access device are physically connected and treated as a single port channel by the primary VLT switch. In case of a primary VLT switch failure, the secondary switch starts...
... default VLT settings, such as a topology change. www.dell.com | support.dell.com Sample RSTP Configuration Using Figure 53-1 as a sample VLT topology, the primary VLT switch will send BPDUs to an access device (switch or server) with the primary switch. BPDUs generated by an RSTP-enabled access device are physically connected and treated as a single port channel by the primary VLT switch. In case of a primary VLT switch failure, the secondary switch starts...
S4820T Configuration Guide
Page 1040
.... 1040 | Virtual Link Trunking (VLT) A syslog error message and an SNMP trap are generated. A syslog error message and an SNMP trap are generated. A syslog error message is generated when the VLTi bandwidth usage goes above its impact, contact your Dell Force10 representative. Remote VLT port N/A N/A Use the show vlt detail and channel status show vlt brief commands to a VLT Domain (From an Attached Access Switch) FTOS_TORswitch(conf)# show running-config interface port-channel...
.... 1040 | Virtual Link Trunking (VLT) A syslog error message and an SNMP trap are generated. A syslog error message and an SNMP trap are generated. A syslog error message is generated when the VLTi bandwidth usage goes above its impact, contact your Dell Force10 representative. Remote VLT port N/A N/A Use the show vlt detail and channel status show vlt brief commands to a VLT Domain (From an Attached Access Switch) FTOS_TORswitch(conf)# show running-config interface port-channel...