Dell Force10 C300 Support and Manuals

Get Help and Manuals for this Dell item

View All Support Options Below
Free Dell Force10 C300 manuals!
Problems with Dell Force10 C300?

Ask a Question

Popular Dell Force10 C300 Manual Pages

FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 454

... lock status. The line number shown in a rollback process. Syntax show configuration lock Defaults None Command Modes EXEC Privilege Command History Example Version 7.7.1.0 Introduced on a VTY line. When set the lock each time before entering CONFIGURATION mode. www.dell.com | support.dell.com show run diff c e Display the difference between an archived file and a file...
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1560

... linecard 2 port-set 0 btm ingress errors FTOS#clear hardware rpm 1 port-set 0 btm ingress errors FTOS#clear hardware rpm 0 port-set 0 btm ingress errors % Error: RPM 0 is not active. Enter the keyword card-shutdown to enable automatic parity corrections for the party-bus control switch on -error to take an action upon a hardware error. www.dell.com | support.dell.com Example Figure...
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1573

...driver information which may be useful during troubleshooting line card initialization errors, such as downed Port-Pipe. show running-config hardware-monitor e Display the hardware-monitor action-on -error card-problem... mac action-on-error port-shutdown hardware monitor linecard asic BTM action-on-error card-reset hardware monitor linecard asic FPC action-on -error settings. show running-config...
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1596

...PEM_PRBLM: Major alarm: problem with power entry module %s NONE NONE NONE NONE NONE NONE NONE NONE NONE SUPPLY 1596 | SNMP Traps www.dell.com | support.dell.com Table B-1. type...SFM 1 CHM_MAJ_SFM_DOWN ENVMON %CHMGR-0-MAJOR_SFM: Major alarm: Switch fabric down - SNMP Traps and Error Messages (continued) Message ID Trap Type CHM_CARD_DOWN ENVMON %CHMGR-1-CARD_SHUTDOWN: %sLine card %d...
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1614

...FTSA command) 514 service password-encryption 1291 service timestamps 102 service-class dynamic dot1p 1184 service-class dynamic dot1p (QoS) 1184, 1185 service-policy input 1205 service-policy output 1206 service-queue 1206 set (policy QoS) 1207 set as-path prepend (Route Map) 278 set automatic-tag (Route Map) 278 set comm-list (Route Map) 279 set community (Route Map) 280 set extcommunity rt (BGP...
FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1635

... 514 service power-off 95 service timestamps 102 service-policy-input 1205, 1217, 1218 service-policy-output 1206 service-queue 1206 set (policy QoS) 1207 set as-path (Route Map) 278 set automatic-tag (Route Map) 278 set comm-list delete (Route Map) 279 set community (Route Map) 280 set extcommunity rt (BGP) 423 set extcommunity soo (BGP) 424 set ipv6 next-hop 712 set level...
FTOS Configuration Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 74

Recovering from a Forgotten Password If you configure authentication for a password to FTOS Boot Interface ***** Use "help" or "?" If you clear a console session, the user is renamed. Power-cycle the chassis by sending the break signal when prompted. for a password. Entering BOOT_USER mode Type "go 0x00040004" to enter the FTOS BLI shell You can clear any line using...
FTOS Configuration Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 75

.... reload 7 Configure a new enable password. Note: This command only bypasses the enable password once. BOOT_USER CONFIGURATION System Management | 75 copy flash://startup-config.bak running config. reload 8 Copy startup-config.bak to ignore the enable password on . Renaming the startup-config RPM0-CP BOOT_ADMIN # dir flash: Directory of the power modules and then switching them back...
FTOS Configuration Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 102

... is not supported on S-Series. www.dell.com | support.dell.com Task Specify the time period for any of the monitored error conditions. There are three critical events; Dying Gasp notification is not supported on S-Series. • Critical Event-An unspecified critical event occurred. When a link fault, dying gasp, or critical event occurs, the system sets an...
FTOS Configuration Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 224

... number. Traps (notifications) specified in a full mesh, and there is no synchronization) 224 | Border Gateway Protocol IPv4 (BGPv4) t = 60 or r = 5. • To return all values on an snmpwalk for various outbound counters. Dell Force10 recommends using options to ignore such errors. • Multiple BPG process instances are set to zero. • 4-byte ASN is supported. Thus...
FTOS Configuration Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 380

...switch fabric is online. RPM Redundancy The current version of FTOS supports 1+1 hitless Route Processor Module (RPM) redundancy. You can assume control of the system without requiring a chassis reboot. www.dell.com | support.dell.com Component Redundancy Dell Force10...on page 381 • Automatic and manual RPM failover on page 382 • Support for RPM redundancy by providing dedicated or...
FTOS Configuration Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 398

... Verify that this patch. www.dell.com | support.dell.com In-Service Modular Hot-Fixes e In-Service Modular Hot-Fixes are identified as though it affects (FTOS-platform-cpu-process-patchversion.rtp). For example, a patch labeled 7.8.1.0-EH-rp2-l2mgr-1.rtp identifies that the patch resides in a deployed system. patch flash://RUNTIME_PATCH_DIR/ CONFIGURATION For example: patch flash...
FTOS Configuration Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 511

...supported for IPv6 routing. This TLV is aligned with troubleshooting and configuration. Its structure is included in which the router determines that carry information required for addressing. This timer can track IS-IS information on adjacency settings with the extended IS Reachability TLV Type 236 and it has failed to achieve database synchronization (by setting a specific...
FTOS Configuration Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25) - Page 1208

...RPM1-S:CP %IRC-4-IRC_WARNLINKDN: Keepalive packet 7 to prevent a manual power cycle. CP trace log file (look for troubleshooting specific problems while working with the phrase "failure_trace") in the following directories... automatically reboots an FTOS switch/router with peer RPM. See the FTOS Command Reference for a filename with Dell Force10 technical support staff. As described in...
Installing and Maintaining the C150 System - Page 28

... LED, and, if configured, an SNMP trap. Blanks are required to the OFF (left) position. 2 Disconnect the AC power cable from the AC power source and the front of the power cord must comply with a redundant power supply, you can install, remove, or replace a power supply without affecting system operation. If you are operating your local electrical codes. Lift the latch, and...

Dell Force10 C300 Reviews

Do you have an experience with the Dell Force10 C300 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Dell yet.

Popular Dell Force10 C300 Search Terms

The following terms are frequently used to search for Dell Force10 C300 support:

Ask a New Question
Use the box below to post a new question about Dell Force10 C300.
Manuals / Documents
Download any of our Dell Force10 C300 manuals for free!

We have the following 5 documents available for the Dell Force10 C300:
  • FTOS Command Line Reference Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25)
  • FTOS Configuration Guide FTOS 8.4.2.7 E-Series TeraScale, C-Series, S-Series (S50/S25)
  • C300 Hardware Installation Guide
  • Installing and Maintaining the C150 System
  • Quick Start Guide

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell Force10 C300 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell Force10 C300 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.