... Be sure to -FRU index, service information, error codes, error messages, and configuration information for trained servicers who are familiar with IBM PC Server products. Prenez connaissance de toutes les consignes de type Attention et Danger avant de procéder aux opérations décrites par les instructions. © Copyright...
... Be sure to -FRU index, service information, error codes, error messages, and configuration information for trained servicers who are familiar with IBM PC Server products. Prenez connaissance de toutes les consignes de type Attention et Danger avant de procéder aux opérations décrites par les instructions. © Copyright...
User Guide
Page 8
... . . . . 80 Ethernet port connector 84 Advanced System Management ports. . . . . 84 Cabling the server 85 Netfinity Manager 87 Managing your IBM Netfinity server with Netfinity Manager 87 Netfinity Manager documentation 88 Netfinity Manager system requirements . . . . . 88 Netfinity Manager for OS/2 system requirements 88...144 DASD checkout 144 Host Built-In Self Test (BIST 144 Bus fault messages 145 Undetermined Problems 145 Parts listing (Type 8658 147 Keyboards 149 Power cords 150 Related service information . . . . . 151 Safety information 152 General safety 152 Electrical safety ...
... . . . . 80 Ethernet port connector 84 Advanced System Management ports. . . . . 84 Cabling the server 85 Netfinity Manager 87 Managing your IBM Netfinity server with Netfinity Manager 87 Netfinity Manager documentation 88 Netfinity Manager system requirements . . . . . 88 Netfinity Manager for OS/2 system requirements 88...144 DASD checkout 144 Host Built-In Self Test (BIST 144 Bus fault messages 145 Undetermined Problems 145 Parts listing (Type 8658 147 Keyboards 149 Power cords 150 Related service information . . . . . 151 Safety information 152 General safety 152 Electrical safety ...
User Guide
Page 12
... cords. v Check the information LED panel System Error LED; If an error was recorded by the system, see "Undetermined Problems" on page 145. 2 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY b. YES. Readable instructions or the Main Menu. 3. If the diagnostics completed successfully and you...
... cords. v Check the information LED panel System Error LED; If an error was recorded by the system, see "Undetermined Problems" on page 145. 2 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY b. YES. Readable instructions or the Main Menu. 3. If the diagnostics completed successfully and you...
User Guide
Page 13
...microprocessor with MMX technology and SIMD extensions v 256 KB Level-2 cache (min.) v Supports up -to two microprocessors Memory: v Standard: 128 MB v Maximum: 4GB v Type: 133 MHz, ECC, SDRAM, Registered DIMMs v Sockets: 4 dual inline sockets Drives standard: v Diskette: 1.44 MB v CD-ROM: 40X IDE Expansion bays: v Hot...) PCI expansion slots: v Three 33 MHz/ 64-bit slots v Two 33 MHz/ 32-bit slots Power supplies: 250 W (115-230 Vac) © Copyright IBM Corp. 2000 3 It is a high-performance, symmetric multiprocessing (SMP) server. To register your server, go to the following World Wide Web...
...microprocessor with MMX technology and SIMD extensions v 256 KB Level-2 cache (min.) v Supports up -to two microprocessors Memory: v Standard: 128 MB v Maximum: 4GB v Type: 133 MHz, ECC, SDRAM, Registered DIMMs v Sockets: 4 dual inline sockets Drives standard: v Diskette: 1.44 MB v CD-ROM: 40X IDE Expansion bays: v Hot...) PCI expansion slots: v Three 33 MHz/ 64-bit slots v Two 33 MHz/ 32-bit slots Power supplies: 250 W (115-230 Vac) © Copyright IBM Corp. 2000 3 It is a high-performance, symmetric multiprocessing (SMP) server. To register your server, go to the following World Wide Web...
User Guide
Page 14
...) per hour: v Minimum configuration: 683 BTU (200 watts) v Maximum configuration: 2048 BTU (600 watts) Electrical input: v Sine-wave input (50-60 Hz) required 4 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY Server off : 10║ to 43║ C (50.0║ to 109.4║ F). Altitude: 0 to...
...) per hour: v Minimum configuration: 683 BTU (200 watts) v Maximum configuration: 2048 BTU (600 watts) Electrical input: v Sine-wave input (50-60 Hz) required 4 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY Server off : 10║ to 43║ C (50.0║ to 109.4║ F). Altitude: 0 to...
User Guide
Page 16
... and Netfinity Manager Information section. v Menu-driven setup, system configuration, RAID configuration, and diagnostic programs v Power-on your IBM server meets stringent worldwide certifications for additional information. The controller provides full-duplex (FDX) capability, which allows simultaneous transmission and ...restart after a power failure 6 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY Refer to 10-Mbps or 100-Mbps networks. v IBM ServerGuide CDs The ServerGuide CDs included with IBM Netfinity servers provide programs to use it; Your...
... and Netfinity Manager Information section. v Menu-driven setup, system configuration, RAID configuration, and diagnostic programs v Power-on your IBM server meets stringent worldwide certifications for additional information. The controller provides full-duplex (FDX) capability, which allows simultaneous transmission and ...restart after a power failure 6 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY Refer to 10-Mbps or 100-Mbps networks. v IBM ServerGuide CDs The ServerGuide CDs included with IBM Netfinity servers provide programs to use it; Your...
User Guide
Page 18
.... Hard Disk Activity Light: Each of the hot-swap drives has a Hard Disk Status light. When this amber light is accessing the drive. 8 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY Operator Information Panel: The lights on this button to reset the server and run...
.... Hard Disk Activity Light: Each of the hot-swap drives has a Hard Disk Status light. When this amber light is accessing the drive. 8 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY Operator Information Panel: The lights on this button to reset the server and run...
User Guide
Page 20
... button for your operating system, and places the server in standby mode. This feature can turn off all power to stop blinking. 10 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY Note: After turning off the server by your system to the server. Note: Wait...
... button for your operating system, and places the server in standby mode. This feature can turn off all power to stop blinking. 10 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY Note: After turning off the server by your system to the server. Note: Wait...
User Guide
Page 22
Ethernet Transmit/Receive Activity Light: This green LED lights when there is transmit or receive activity to or from the server. 12 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
Ethernet Transmit/Receive Activity Light: This green LED lights when there is transmit or receive activity to or from the server. 12 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
User Guide
Page 23
... problems that are part of the light-path diagnostics that might cause several error messages. The System Event/Error Log contains all error © Copyright IBM Corp. 2000 13 See "POST error codes" on self-test (POST) generates beep codes and messages to indicate successful test completion or the detection ... server components. If POST detects a problem, more than one beep sounds and an error message appears on password or administrator password set, you must type the password and press Enter, when prompted, before POST will not occur the next time you can quickly identify the...
... problems that are part of the light-path diagnostics that might cause several error messages. The System Event/Error Log contains all error © Copyright IBM Corp. 2000 13 See "POST error codes" on self-test (POST) generates beep codes and messages to indicate successful test completion or the detection ... server components. If POST detects a problem, more than one beep sounds and an error message appears on password or administrator password set, you must type the password and press Enter, when prompted, before POST will not occur the next time you can quickly identify the...
User Guide
Page 24
... a hard disk drive, ignore any LEDs that the BIOS is good and the power supplies can supply +5V dc current to quickly identify the type of error that occurred. See "Power supply LED errors" on the power supply provide status information about the power supply. To view the contents .... You will be on the system board. Identifying problems using status LEDs If the System Error light in "SCSI error codes" on 14 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY Diagnostics panel The following illustration shows the LEDs on the diagnostics panel on ....
... a hard disk drive, ignore any LEDs that the BIOS is good and the power supplies can supply +5V dc current to quickly identify the type of error that occurred. See "Power supply LED errors" on the power supply provide status information about the power supply. To view the contents .... You will be on the system board. Identifying problems using status LEDs If the System Error light in "SCSI error codes" on 14 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY Diagnostics panel The following illustration shows the LEDs on the diagnostics panel on ....
User Guide
Page 26
... discovers an error. To exit Help and return to the function code (fff) given in the appropriate password; Turn on the screen. 16 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY iii is the name of the function being tested when the error occurred. Text.... 5. Note: To run from which you can select different categories. then, press Enter. 4. Select either Extended or Basic from the top of the system configuration. Type in the previous list. Test Specific String This is used to obtain Help information. text message is set .
... discovers an error. To exit Help and return to the function code (fff) given in the appropriate password; Turn on the screen. 16 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY iii is the name of the function being tested when the error occurred. Text.... 5. Note: To run from which you can select different categories. then, press Enter. 4. Select either Extended or Basic from the top of the system configuration. Type in the previous list. Test Specific String This is used to obtain Help information. text message is set .
User Guide
Page 27
... mouse (pointing device) tests assume that appears; Viewing the test log The test log will not be the cause. When the message F2 for it. Type in "Diagnostic error codes" on . Turn on the screen. When the Diagnostic Programs screen appears, select Utility from the top of the error messages that...
... mouse (pointing device) tests assume that appears; Viewing the test log The test log will not be the cause. When the message F2 for it. Type in "Diagnostic error codes" on . Turn on the screen. When the Diagnostic Programs screen appears, select Utility from the top of the error messages that...
User Guide
Page 28
...1 and 2 to normal startup mode. 9. If the cable is installed correctly. If the label contains an X, the hub has an X port. 18 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY To recover the BIOS: 1. A progress report, Loading data from diskette xx%, is a..., try a different cable. When recovery is complete, Recovery complete, remove the diskette and return boot block switch to http://www.pc.ibm.com/support/, select IBM Server Support, and make a BIOS flash diskette. Note: To determine whether a hub has an X port, check the port label.
...1 and 2 to normal startup mode. 9. If the cable is installed correctly. If the label contains an X, the hub has an X port. 18 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY To recover the BIOS: 1. A progress report, Loading data from diskette xx%, is a..., try a different cable. When recovery is complete, Recovery complete, remove the diskette and return boot block switch to http://www.pc.ibm.com/support/, select IBM Server Support, and make a BIOS flash diskette. Note: To determine whether a hub has an X port, check the port label.
User Guide
Page 30
... initialization command. Table 1. Try sending data from the following : v Run diagnostics for PCI devices, some devices do not run the diagnostic programs. 20 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY If necessary, remove any LED parameter settings when you are using the correct keyword...
... initialization command. Table 1. Try sending data from the following : v Run diagnostics for PCI devices, some devices do not run the diagnostic programs. 20 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY If necessary, remove any LED parameter settings when you are using the correct keyword...
User Guide
Page 32
...if you use the node address override capabilities of the error messages for the I/O address. You tried to resolve each problem. 22 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY Explanation: The local bit in the IEEE address format indicates that...cleared. Table 2. Explanation: The IEEE address has a group bit that indicates that the Ethernet controller is enabled, go to load a new frame type for PCI device. The hardware assumptions made in the node address override was not found . The driver has set . You entered an address ...
...if you use the node address override capabilities of the error messages for the I/O address. You tried to resolve each problem. 22 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY Explanation: The local bit in the IEEE address format indicates that...cleared. Table 2. Explanation: The IEEE address has a group bit that indicates that the Ethernet controller is enabled, go to load a new frame type for PCI device. The hardware assumptions made in the node address override was not found . The driver has set . You entered an address ...
User Guide
Page 34
... connection and has transferred all network traffic to the primary Ethernet controller. PermaNet Server: Explanation: The system detected a problem with each problem. 24 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY Action: identify the cause of the primary connection will automatically transfer to the secondary...
... connection and has transferred all network traffic to the primary Ethernet controller. PermaNet Server: Explanation: The system detected a problem with each problem. 24 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY Action: identify the cause of the primary connection will automatically transfer to the secondary...
User Guide
Page 36
...Action: v Modify your hardware settings. Out of the power distribution busses. Vector already shared at different IPL. pnt0-29 Explanation: The IBM Netfinity 10/100 Fault Tolerant Adapter does not require a DMA setting. The IRQ number is not necessary for the PCI device. Action... your hardware settings. I /O address specified for the Ethernet controller Power checkout Power problems can exist anywhere on a circuit board. 26 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY For instance, a short circuit can be difficult to search for ...
...Action: v Modify your hardware settings. Out of the power distribution busses. Vector already shared at different IPL. pnt0-29 Explanation: The IBM Netfinity 10/100 Fault Tolerant Adapter does not require a DMA setting. The IRQ number is not necessary for the PCI device. Action... your hardware settings. I /O address specified for the Ethernet controller Power checkout Power problems can exist anywhere on a circuit board. 26 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY For instance, a short circuit can be difficult to search for ...
User Guide
Page 37
... to be aware of minimal configuration one at minimum configuration required for information about battery disposal. To order replacement batteries, call 1-800-IBM-4333 for power on (see page 145). Remove the battery: Diagnostics 27 They will be taken back free of charge by local ...ordinances or regulations. To replace the battery: 1. Reconnect the AC cord and power on page 142. To use only IBM Part Number 10L6432 or an equivalent type battery recommended by the same manufacturer. v Follow any special handling and installation instructions supplied with the same module...
... to be aware of minimal configuration one at minimum configuration required for information about battery disposal. To order replacement batteries, call 1-800-IBM-4333 for power on (see page 145). Remove the battery: Diagnostics 27 They will be taken back free of charge by local ...ordinances or regulations. To replace the battery: 1. Reconnect the AC cord and power on page 142. To use only IBM Part Number 10L6432 or an equivalent type battery recommended by the same manufacturer. v Follow any special handling and installation instructions supplied with the same module...
User Guide
Page 38
... the system date and time. Tilt the battery so that the battery clip is touching the base of the system is operating 28 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY a. b. d. c. Insert the new battery: a. Temperature checkout Proper cooling of the battery socket by pressing...
... the system date and time. Tilt the battery so that the battery clip is touching the base of the system is operating 28 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY a. b. d. c. Insert the new battery: a. Temperature checkout Proper cooling of the battery socket by pressing...