Hardware Maintenance Manual
Page 7
... messages . . . . 12 Text messages 13 Starting the diagnostic programs 14 Viewing the test log 14 Diagnostic error messages 15 Power checkout 15 Recovering BIOS 15 Identifying problems using status LEDs . . . . . 17 Front panel and system board LEDs . . . . . 17 Diagnostic LEDs 17... . . 37 Choices available from the PXE boot agent menu 37 Installing options 39 Major components of the xSeries 220 server . . . 39 System board 40 System board options connectors 40 © Copyright IBM Corp. 2001 System board internal cable connectors . . . . 41 System board external port connectors . ....
... messages . . . . 12 Text messages 13 Starting the diagnostic programs 14 Viewing the test log 14 Diagnostic error messages 15 Power checkout 15 Recovering BIOS 15 Identifying problems using status LEDs . . . . . 17 Front panel and system board LEDs . . . . . 17 Diagnostic LEDs 17... . . 37 Choices available from the PXE boot agent menu 37 Installing options 39 Major components of the xSeries 220 server . . . 39 System board 40 System board options connectors 40 © Copyright IBM Corp. 2001 System board internal cable connectors . . . . 41 System board external port connectors . ....
Hardware Maintenance Manual
Page 12
...available in drive cage (some models) Expansion bays: v Two 5.25-in . Features and specifications This section provides a summary of the features and specifications of the xSeries 220 server. bays (one diskette drive installed) v Three 3.5-in .) v Weight: approximately 19.5 kg (43 lb.) when fully configured or 15.9 kg (35 lb... MHz/32-bit Power supply: One 330 watt autosensing (115-230 V ac) Video: v S3 video controller (integrated on LAN® support v Automatic BIOS Recovery (ABR) v Automatic Server Restart (ASR) v Two serial ports 4 Hardware Maintenance Manual: xSeries 220 Type 8646
...available in drive cage (some models) Expansion bays: v Two 5.25-in . Features and specifications This section provides a summary of the features and specifications of the xSeries 220 server. bays (one diskette drive installed) v Three 3.5-in .) v Weight: approximately 19.5 kg (43 lb.) when fully configured or 15.9 kg (35 lb... MHz/32-bit Power supply: One 330 watt autosensing (115-230 V ac) Video: v S3 video controller (integrated on LAN® support v Automatic BIOS Recovery (ABR) v Automatic Server Restart (ASR) v Two serial ports 4 Hardware Maintenance Manual: xSeries 220 Type 8646
Hardware Maintenance Manual
Page 14
... Processor serial number access v System error logging (POST) v Upgradeable basic input/output system (BIOS) code and diagnostics 6 Hardware Maintenance Manual: xSeries 220 Type 8646 In addition, the ServerGuide CDs include a variety of data on LAN function and has an interface... 100BASE-TX environments. Reliability, availability, and serviceability Three of independent disks (RAID) configuration, and diagnostic programs v Optional IBM Remote Supervisor Adapter subsystem to provide control for more information. The following is included with internal error checking v Diagnostic light...
... Processor serial number access v System error logging (POST) v Upgradeable basic input/output system (BIOS) code and diagnostics 6 Hardware Maintenance Manual: xSeries 220 Type 8646 In addition, the ServerGuide CDs include a variety of data on LAN function and has an interface... 100BASE-TX environments. Reliability, availability, and serviceability Three of independent disks (RAID) configuration, and diagnostic programs v Optional IBM Remote Supervisor Adapter subsystem to provide control for more information. The following is included with internal error checking v Diagnostic light...
Hardware Maintenance Manual
Page 16
...system. v The server has an Automatic BIOS Recovery (ABR) feature which allows recovery from an Advanced Configuration and Power Interface (ACPI) operating system. - During this time, the system is present. - Notes: 1. v If the IBM Remote Supervisor Adapter is an operating system...can install a circular disk over . See "System board options connectors" on page 30 for connector locations. 8 Hardware Maintenance Manual: xSeries 220 Type 8646 The Wake on or off. Power-control button: Press this button to prevent accidental manual power-off. v The server provides Automatic ...
...system. v The server has an Automatic BIOS Recovery (ABR) feature which allows recovery from an Advanced Configuration and Power Interface (ACPI) operating system. - During this time, the system is present. - Notes: 1. v If the IBM Remote Supervisor Adapter is an operating system...can install a circular disk over . See "System board options connectors" on page 30 for connector locations. 8 Hardware Maintenance Manual: xSeries 220 Type 8646 The Wake on or off. Power-control button: Press this button to prevent accidental manual power-off. v The server provides Automatic ...
Hardware Maintenance Manual
Page 20
... v An improperly installed SCSI terminator v A defective SCSI terminator v An improperly installed cable v A defective cable Action: Verify that the BIOS is terminated properly. v One beep indicates the successful completion of the error logs, start the Configuration/Setup Utility program (see "Starting the... cables for all external SCSI devices are the primary method of testing the major components of the server. 12 Hardware Maintenance Manual: xSeries 220 Type 8646 Table 1. Note: If your server does not have a hard disk drive, ignore any message that indicates that : v The external...
... v An improperly installed SCSI terminator v A defective SCSI terminator v An improperly installed cable v A defective cable Action: Verify that the BIOS is terminated properly. v One beep indicates the successful completion of the error logs, start the Configuration/Setup Utility program (see "Starting the... cables for all external SCSI devices are the primary method of testing the major components of the server. 12 Hardware Maintenance Manual: xSeries 220 Type 8646 Table 1. Note: If your server does not have a hard disk drive, ignore any message that indicates that : v The external...
Hardware Maintenance Manual
Page 23
...one at a time until the problem is at a time until system is isolated. The server has an Automatic BIOS Recovery (ABR) feature which allows recovery when the BIOS is damaged when the server loses power during the flash update). When you turn off the system and disconnect ... cleared. Reconnect the AC cord and power on the screen. Power checkout Power problems can exist anywhere on a circuit board. 3. However, the primary BIOS should be difficult to the server, the test log is a loose screw causing a short circuit on any of the screen. 4. A general procedure...
...one at a time until the problem is at a time until system is isolated. The server has an Automatic BIOS Recovery (ABR) feature which allows recovery when the BIOS is damaged when the server loses power during the flash update). When you turn off the system and disconnect ... cleared. Reconnect the AC cord and power on the screen. Power checkout Power problems can exist anywhere on a circuit board. 3. However, the primary BIOS should be difficult to the server, the test log is a loose screw causing a short circuit on any of the screen. 4. A general procedure...
Hardware Maintenance Manual
Page 24
... the ABR feature is not normally required. Reconnect the power cord. 16 Hardware Maintenance Manual: xSeries 220 Type 8646 Note: You can obtain a BIOS flash diskette from the backup BIOS page. Follow the on the system board. Normally this action is disabled, regardless of the ...J38 on -screen instructions to the backup BIOS page during the diskette flash update process. To recover the BIOS, do the following sources: v Use the ServerGuide program to http://www.ibm.com/pc/support/, select IBM Server Support, and make a BIOS flash diskette. Restart the server. Another ...
... the ABR feature is not normally required. Reconnect the power cord. 16 Hardware Maintenance Manual: xSeries 220 Type 8646 Note: You can obtain a BIOS flash diskette from the backup BIOS page. Follow the on the system board. Normally this action is disabled, regardless of the ...J38 on -screen instructions to the backup BIOS page during the diskette flash update process. To recover the BIOS, do the following sources: v Use the ServerGuide program to http://www.ibm.com/pc/support/, select IBM Server Support, and make a BIOS flash diskette. Restart the server. Another ...
Hardware Maintenance Manual
Page 25
... 4) fault VRM 1 Microprocessor VRM number 1 (connector J42) fault (see note 1) VRM 2 Microprocessor VRM number 2 (connector J12) fault (see "Symptom-to update the BIOS. 8. Re-connect the power cord and all external cables and re-install the cover. 11. Front panel and system board LEDs The system error LED... is operating properly. Restart the server. The fan and VRM LEDs will illuminate only if the IBM Remote Supervisor Adapter is complete. 9. Insert the BIOS flash diskette in the server. 2. Turn off the server and unplug the power cord when the flash update is...
... 4) fault VRM 1 Microprocessor VRM number 1 (connector J42) fault (see note 1) VRM 2 Microprocessor VRM number 2 (connector J12) fault (see "Symptom-to update the BIOS. 8. Re-connect the power cord and all external cables and re-install the cover. 11. Front panel and system board LEDs The system error LED... is operating properly. Restart the server. The fan and VRM LEDs will illuminate only if the IBM Remote Supervisor Adapter is complete. 9. Insert the BIOS flash diskette in the server. 2. Turn off the server and unplug the power cord when the flash update is...
Hardware Maintenance Manual
Page 28
...and installation instructions supplied with the same module type made by the manufacturer. v Set passwords if necessary. 20 Hardware Maintenance Manual: xSeries 220 Type 8646 Do the following to lift the battery from the battery. b. Reinstall the server cover and connect all external cables; v Set...Press the battery down into water v Heat to press the top of the battery socket by local ordinances or regulations. Start the BIOS Setup Utility program and set configuration parameters. b. If your thumb and index finger to replace the battery: 1. CAUTION: When replacing ...
...and installation instructions supplied with the same module type made by the manufacturer. v Set passwords if necessary. 20 Hardware Maintenance Manual: xSeries 220 Type 8646 Do the following to lift the battery from the battery. b. Reinstall the server cover and connect all external cables; v Set...Press the battery down into water v Heat to press the top of the battery socket by local ordinances or regulations. Start the BIOS Setup Utility program and set configuration parameters. b. If your thumb and index finger to replace the battery: 1. CAUTION: When replacing ...
Hardware Maintenance Manual
Page 30
...controllers. If not, try configuring the integrated Ethernet controller manually to noise-inducing sources like fluorescent lights. 22 Hardware Maintenance Manual: xSeries 220 Type 8646 v The network might be changed by device driver load parameters. Check the following : v Make sure that the device drivers...device drivers are operating and that have loaded the network device drivers. v Determine if the hub supports auto-negotiation. The PCI BIOS interrupt settings are using the most recent device driver available from this LED can use the following : v Determine if the ...
...controllers. If not, try configuring the integrated Ethernet controller manually to noise-inducing sources like fluorescent lights. 22 Hardware Maintenance Manual: xSeries 220 Type 8646 v The network might be changed by device driver load parameters. Check the following : v Make sure that the device drivers...device drivers are operating and that have loaded the network device drivers. v Determine if the hub supports auto-negotiation. The PCI BIOS interrupt settings are using the most recent device driver available from this LED can use the following : v Determine if the ...
Hardware Maintenance Manual
Page 31
... driver must be issued. The Ethernet controller stopped working when another adapter was made to another device in internal table. Refer to your PCI system BIOS is connected to the ServerGuide information. Table 4. AFT teams. If the problem persists, contact your network supplier. v Determine if the interrupt (IRQ) setting assigned to...
... driver must be issued. The Ethernet controller stopped working when another adapter was made to another device in internal table. Refer to your PCI system BIOS is connected to the ServerGuide information. Table 4. AFT teams. If the problem persists, contact your network supplier. v Determine if the interrupt (IRQ) setting assigned to...
Hardware Maintenance Manual
Page 37
...a collection of application programs, which you must use these CDs during the initial installation of the basic input/output system (BIOS) that comes with the server: v Configuration/Setup Utility This program is installed in SCSISelect Utility program, you install the ...utility program" on page 35 for more information. You can configure the devices attached to the ServeRAID documentation provided on the IBM xSeries Documentation CD. v ServerGuide CDs The ServerGuide CDs include software setup and installation tools specifically designed for Configuration/Setup appears, press ...
...a collection of application programs, which you must use these CDs during the initial installation of the basic input/output system (BIOS) that comes with the server: v Configuration/Setup Utility This program is installed in SCSISelect Utility program, you install the ...utility program" on page 35 for more information. You can configure the devices attached to the ServeRAID documentation provided on the IBM xSeries Documentation CD. v ServerGuide CDs The ServerGuide CDs include software setup and installation tools specifically designed for Configuration/Setup appears, press ...
Hardware Maintenance Manual
Page 38
... of the choices that you make to the following: IBM Setup - © IBM Corporation 2001 Configuration/Setup Utility · System Summary · System Information · Devices and I /O Ports 30 Hardware Maintenance Manual: xSeries 220 Type 8646 Product Data Select this choice to display help information for...in the server. The System Information choice appears only on the screen. The choices on some menus might appear on the BIOS version in the flash electrically erasable programmable ROM (EEPROM). Choices available from the main menu are described in this choice ...
... of the choices that you make to the following: IBM Setup - © IBM Corporation 2001 Configuration/Setup Utility · System Summary · System Information · Devices and I /O Ports 30 Hardware Maintenance Manual: xSeries 220 Type 8646 Product Data Select this choice to display help information for...in the server. The System Information choice appears only on the screen. The choices on some menus might appear on the BIOS version in the flash electrically erasable programmable ROM (EEPROM). Choices available from the main menu are described in this choice ...
Hardware Maintenance Manual
Page 39
.... You also can define a startup sequence that checks for devices and input/output ports. If the Boot Fail Count choice is disabled, the BIOS system defaults can enable a virus-detection test that checks for more information. v Advanced Setup Configuration 31 The system time is Disabled. See "...forgotten, it cannot be changed by the user. You can only be loaded from which the operating system starts. You also can restore the BIOS system defaults after three consecutive boot failures. If you can select to run without a diskette drive, monitor, or keyboard. Power-on page ...
.... You also can define a startup sequence that checks for devices and input/output ports. If the Boot Fail Count choice is disabled, the BIOS system defaults can enable a virus-detection test that checks for more information. v Advanced Setup Configuration 31 The system time is Disabled. See "...forgotten, it cannot be changed by the user. You can only be loaded from which the operating system starts. You also can restore the BIOS system defaults after three consecutive boot failures. If you can select to run without a diskette drive, monitor, or keyboard. Power-on page ...
Hardware Maintenance Manual
Page 50
... J16 On-board Ethernet controller No jumper J20 Automatic BIOS Recovery (ABR) No jumper J28 On-board Video controller No jumper J33 Reserved J37 On-board SCSI controller No jumper J38 Flash ROM page jumper Jumper pins 2 and 3 42 Hardware Maintenance Manual: xSeries 220 Type 8646 System board jumpers and switches The following table...
... J16 On-board Ethernet controller No jumper J20 Automatic BIOS Recovery (ABR) No jumper J28 On-board Video controller No jumper J33 Reserved J37 On-board SCSI controller No jumper J38 Flash ROM page jumper Jumper pins 2 and 3 42 Hardware Maintenance Manual: xSeries 220 Type 8646 System board jumpers and switches The following table...
Hardware Maintenance Manual
Page 51
...switch block, and switch 1 is no jumper installed (ASR enabled). The default setting for each switch. For backup POST/BIOS, place a jumper between pins 2 and 3 (primary POST/BIOS). As pictured in the switch block. Changing the jumper position after being reset. Automatic Server Restart (ASR) To enable Automatic...J38) 123 Flash ROM page jumper (J38) determines whether primary or secondary (backup) POST/BIOS code is Off for all switches in this action is not required, but if the primary BIOS is damaged, and ABR is not functioning properly, the jumper can be moved for J20 is...
...switch block, and switch 1 is no jumper installed (ASR enabled). The default setting for each switch. For backup POST/BIOS, place a jumper between pins 2 and 3 (primary POST/BIOS). As pictured in the switch block. Changing the jumper position after being reset. Automatic Server Restart (ASR) To enable Automatic...J38) 123 Flash ROM page jumper (J38) determines whether primary or secondary (backup) POST/BIOS code is Off for all switches in this action is not required, but if the primary BIOS is damaged, and ABR is not functioning properly, the jumper can be moved for J20 is...
Hardware Maintenance Manual
Page 56
... of the PCI slots, but you install a video adapter, the server BIOS automatically disables the integrated video controller. See the xSeries 220 ServerProven list at http://www.ibm.com/pc/compat/ for 64-bit adapters. then the 48 Hardware Maintenance Manual: xSeries 220 Type 8646 Working with adapters You can install up to five peripheral component interconnect...
... of the PCI slots, but you install a video adapter, the server BIOS automatically disables the integrated video controller. See the xSeries 220 ServerProven list at http://www.ibm.com/pc/compat/ for 64-bit adapters. then the 48 Hardware Maintenance Manual: xSeries 220 Type 8646 Working with adapters You can install up to five peripheral component interconnect...
Hardware Maintenance Manual
Page 69
...select Advanced Setup, select Memory Settings, highlight the connector or bank of connectors from Disabled to update the server basic input/output system (BIOS). For a list of -sale applications, integrated manufacturing solutions, and other applications. If you install a microprocessor in microprocessor connector (U11...that is installed in this occurs, you must also install a VRM when you install a microprocessor. 4. If necessary, see http://www.ibm.com/pc/compat/ on the system board. The server comes with one microprocessor, which is installed on the World Wide Web. 3. ...
...select Advanced Setup, select Memory Settings, highlight the connector or bank of connectors from Disabled to update the server basic input/output system (BIOS). For a list of -sale applications, integrated manufacturing solutions, and other applications. If you install a microprocessor in microprocessor connector (U11...that is installed in this occurs, you must also install a VRM when you install a microprocessor. 4. If necessary, see http://www.ibm.com/pc/compat/ on the system board. The server comes with one microprocessor, which is installed on the World Wide Web. 3. ...
Hardware Maintenance Manual
Page 79
... SDA Horizontal synchronization (Hsync) Vertical synchronization (Vsync) DDC SCL Installing options 71 This controller is not removable, but you install a PCI video adapter, the server BIOS will automatically disable the integrated video controller. Auxiliary-device (pointing device) port The system board has one auxiliary-device port that supports a mouse or other...
... SDA Horizontal synchronization (Hsync) Vertical synchronization (Vsync) DDC SCL Installing options 71 This controller is not removable, but you install a PCI video adapter, the server BIOS will automatically disable the integrated video controller. Auxiliary-device (pointing device) port The system board has one auxiliary-device port that supports a mouse or other...
Hardware Maintenance Manual
Page 99
... servicing the computer. Once the configuration has reset to the default, it must be saved in CMOS. 3. The POST BIOS displays POST error codes and messages on page 1. Beep symptoms Beep symptoms are short tones or a series of short tones... (CMOS write/read test failed) 1-1-4 (BIOS EEPROM checksum failed) 1-2-1 (Programmable Interval Timer failed) 1-2-2 (DMA initialization failed) FRU/Action 1. System Board © Copyright IBM Corp. 2001 91 Notes: 1. Check the configuration before you decide which FRUs to -FRU index This index supports xSeries 220 servers. Reflash...
... servicing the computer. Once the configuration has reset to the default, it must be saved in CMOS. 3. The POST BIOS displays POST error codes and messages on page 1. Beep symptoms Beep symptoms are short tones or a series of short tones... (CMOS write/read test failed) 1-1-4 (BIOS EEPROM checksum failed) 1-2-1 (Programmable Interval Timer failed) 1-2-2 (DMA initialization failed) FRU/Action 1. System Board © Copyright IBM Corp. 2001 91 Notes: 1. Check the configuration before you decide which FRUs to -FRU index This index supports xSeries 220 servers. Reflash...