Owner's Manual
Page 7
...1L 1M 1P Part Name Lens Top Plate Assembly Light Socket (2) Motor Assembly Cover Motor Drive Board Controller Board No. 10-24 x 3/8" Hex Head No. 8-32 x 1" Phillips Screw No. 8-32 x 3/8" Slotted Hex Head Screw Power Cord For Help, call 1-800-35-GENIE or visit www.geniecompany.com 7 Parts List...16"-18 x 11/16" Hex Head Shoulder Bolt (blue bag) 8 5/16"-18 Hex Serrated Flange Nut (blue & orange bags) varies/model 12 Magnetic Carriage Assembly (main carton) 1 1 Collar (blue bag) 3 Retaining Clip (blue bag) 3 Rail Strap (blue bag) 1 1 1/4"-20 Hex Head Bolt (blue bag) 2 2 Open...
...1L 1M 1P Part Name Lens Top Plate Assembly Light Socket (2) Motor Assembly Cover Motor Drive Board Controller Board No. 10-24 x 3/8" Hex Head No. 8-32 x 1" Phillips Screw No. 8-32 x 3/8" Slotted Hex Head Screw Power Cord For Help, call 1-800-35-GENIE or visit www.geniecompany.com 7 Parts List...16"-18 x 11/16" Hex Head Shoulder Bolt (blue bag) 8 5/16"-18 Hex Serrated Flange Nut (blue & orange bags) varies/model 12 Magnetic Carriage Assembly (main carton) 1 1 Collar (blue bag) 3 Retaining Clip (blue bag) 3 Rail Strap (blue bag) 1 1 1/4"-20 Hex Head Bolt (blue bag) 2 2 Open...
Owner's Manual
Page 10
... Twist Ties. #8-32 x 1" Hex Head Screws Open Limit Switch Assembly 22 Wire Clips 53 19Brown Wire 24 Emergency Release Cord 25 C Place Switches on Assembled Rail 10 For Help, call 1-800-35-GENIE or visit www.geniecompany.com Assembly Step C3H: INSTALL MAGNETIC CARRIAGE ASSEMBLY ONTO RAILS A Place Magnetic Carriage Assembly Lever in "release" position. End Rail Section 4C 8 Figure...
... Twist Ties. #8-32 x 1" Hex Head Screws Open Limit Switch Assembly 22 Wire Clips 53 19Brown Wire 24 Emergency Release Cord 25 C Place Switches on Assembled Rail 10 For Help, call 1-800-35-GENIE or visit www.geniecompany.com Assembly Step C3H: INSTALL MAGNETIC CARRIAGE ASSEMBLY ONTO RAILS A Place Magnetic Carriage Assembly Lever in "release" position. End Rail Section 4C 8 Figure...
Owner's Manual
Page 11
...wires Switch wires Figure 15 Connect Limit Switch Wires to call 1-800-35-GENIE or visit www.geniecompany.com 11 D Attach Emergency Release Tag to Magnetic Carriage Assembly Release Lever. 25 Emergency Release Tag Assembly Step C8H: RECORD OPENER MODEL AND SERIAL NUMBER Please note the following information... and Tag Model Number NOTE Please keep original or photocopy of your sales receipt with Wire Clips (Figure 14). F Lay Wires in Magnetic Carriage Assembly Release Lever (Figure 16). G Coil and bundle excess Limit Switch Wires on back of Power Head with Twist Ties. NOTE •...
...wires Switch wires Figure 15 Connect Limit Switch Wires to call 1-800-35-GENIE or visit www.geniecompany.com 11 D Attach Emergency Release Tag to Magnetic Carriage Assembly Release Lever. 25 Emergency Release Tag Assembly Step C8H: RECORD OPENER MODEL AND SERIAL NUMBER Please note the following information... and Tag Model Number NOTE Please keep original or photocopy of your sales receipt with Wire Clips (Figure 14). F Lay Wires in Magnetic Carriage Assembly Release Lever (Figure 16). G Coil and bundle excess Limit Switch Wires on back of Power Head with Twist Ties. NOTE •...
Owner's Manual
Page 15
...GENIE or visit www.geniecompany.com Figure 24 Assemble Arms (ONE-PIECE) 15 For one-piece doors: A Attach Straight Arm to Door Bracket with garage door fully or partially open, garage door may leave Emergency Release Knob within reach of children. WARNING Do Not skip Step D above floor: • Pull Cord through Magnetic Carriage Assembly... to 6' above floor: • Pull Cord through Magnetic Carriage Assembly Lever until Knob is 6' from floor. • Tie a new overhand knot in Cord at Magnetic Carriage Assembly Lever. Securely tighten fasteners. D Adjust height of Emergency...
...GENIE or visit www.geniecompany.com Figure 24 Assemble Arms (ONE-PIECE) 15 For one-piece doors: A Attach Straight Arm to Door Bracket with garage door fully or partially open, garage door may leave Emergency Release Knob within reach of children. WARNING Do Not skip Step D above floor: • Pull Cord through Magnetic Carriage Assembly... to 6' above floor: • Pull Cord through Magnetic Carriage Assembly Lever until Knob is 6' from floor. • Tie a new overhand knot in Cord at Magnetic Carriage Assembly Lever. Securely tighten fasteners. D Adjust height of Emergency...
Owner's Manual
Page 20
...garage door. - If door does not open ) Carriage (disengaged) Magnet Figure 34 Setting Limit Switches Force Controls HI LO HI LO OPEN CLOSE FORCE FORCE Figure 35 Making Force Adjustments 20 For Help, call 1-800-35-GENIE or visit www.geniecompany.com See Safe-T-Beam®...- If door fails to full open garage door to move slowly the first time it is aligned with Carriage Assembly Magnet. • Tighten Set Screw. Do Not over -tighten. • Re-engage Magnetic Carriage Assembly. B Setting Open Limit Switch: • Manually open position. • Slide Open Limit Switch until it...
...garage door. - If door does not open ) Carriage (disengaged) Magnet Figure 34 Setting Limit Switches Force Controls HI LO HI LO OPEN CLOSE FORCE FORCE Figure 35 Making Force Adjustments 20 For Help, call 1-800-35-GENIE or visit www.geniecompany.com See Safe-T-Beam®...- If door fails to full open garage door to move slowly the first time it is aligned with Carriage Assembly Magnet. • Tighten Set Screw. Do Not over -tighten. • Re-engage Magnetic Carriage Assembly. B Setting Open Limit Switch: • Manually open position. • Slide Open Limit Switch until it...
Owner's Manual
Page 25
...; Balance Door. - For Help, call Customer Service at 1-800-35-GENIE. - B Install Lens into Light Sockets (Figure 41): • Rough service, 130 Volt bulbs are broken. Pull the Emergency Release Knob toward Power Head. Operation is acceptable. Reattach Magnetic Carriage Assembly to close Lens Figure 41 Install Lens Cover and Light Bulbs A Install two...
...; Balance Door. - For Help, call Customer Service at 1-800-35-GENIE. - B Install Lens into Light Sockets (Figure 41): • Rough service, 130 Volt bulbs are broken. Pull the Emergency Release Knob toward Power Head. Operation is acceptable. Reattach Magnetic Carriage Assembly to close Lens Figure 41 Install Lens Cover and Light Bulbs A Install two...
Owner's Manual
Page 28
...licensed electrician must replace non-compatible GFCI's. Replace any loose connections. Wall Console Vacation Lock function does not work • Ensure Magnetic Carriage Assembly is "Closed" (not tripped). • If still no apparent reason Door starts down, then stops before it is completely closed... Force Controls on page 20). If not: - Adjust as detailed in contact with the garage door hardware or springs,contact a Genie Factory Authorized De aler for no power, have a licensed electrician check circuit and wiring. 2. Check their condition and either replace ...
...licensed electrician must replace non-compatible GFCI's. Replace any loose connections. Wall Console Vacation Lock function does not work • Ensure Magnetic Carriage Assembly is "Closed" (not tripped). • If still no apparent reason Door starts down, then stops before it is completely closed... Force Controls on page 20). If not: - Adjust as detailed in contact with the garage door hardware or springs,contact a Genie Factory Authorized De aler for no power, have a licensed electrician check circuit and wiring. 2. Check their condition and either replace ...