Owner's Manual
Page 4
... "open and close " button until the door reaches its fully opened position. Wall Console Operates door opener from door opener. Contact your Genie® Professional Dealer for an Assembly/Installation Instructions poster, if needed , or call 1-800-35GENIE. If the Safe-T-Beam® System ... (Not available on the wall console during a power failure or other emergency to allow the door to a desired rate, vary limits and force, and program new remotes. 2 Features Begin here only after completing assembly and installation of opener. The wall console has an indicator light with ...
... "open and close " button until the door reaches its fully opened position. Wall Console Operates door opener from door opener. Contact your Genie® Professional Dealer for an Assembly/Installation Instructions poster, if needed , or call 1-800-35GENIE. If the Safe-T-Beam® System ... (Not available on the wall console during a power failure or other emergency to allow the door to a desired rate, vary limits and force, and program new remotes. 2 Features Begin here only after completing assembly and installation of opener. The wall console has an indicator light with ...
Owner's Manual
Page 5
... you will take you . The following information to set how far your Genie garage door opener is used to familiarize yourself with additional remote control devices, wall consoles, keypads, and the powerhead. 3. Door Travel Limits Program - This program is installed, you through programming your opener so it functions properly for minor adjustments under certain circumstances...
... you will take you . The following information to set how far your Genie garage door opener is used to familiarize yourself with additional remote control devices, wall consoles, keypads, and the powerhead. 3. Door Travel Limits Program - This program is installed, you through programming your opener so it functions properly for minor adjustments under certain circumstances...
Owner's Manual
Page 6
... to property. • DO NOT operate this unit from wall console before LIMITS are set. PROGRAM SET + NOTE: If shuttle/bullet has NOT been engaged to complete each step. PROGRAM PROGRAM SET + SET HOLD 2 seconds 6 PROGRAM SET + NOTE: You have run out of the step and start over. ... until garage door is fully closed on the Powerhead, you see two solid red or flashing LEDs on floor, then release. 3 Required Programming TRAVEL LIMITS WARNING • Make sure doorway is ON. Severe damage to the opener can restart as many times as necessary to carriage, do so...
... to property. • DO NOT operate this unit from wall console before LIMITS are set. PROGRAM SET + NOTE: If shuttle/bullet has NOT been engaged to complete each step. PROGRAM PROGRAM SET + SET HOLD 2 seconds 6 PROGRAM SET + NOTE: You have run out of the step and start over. ... until garage door is fully closed on the Powerhead, you see two solid red or flashing LEDs on floor, then release. 3 Required Programming TRAVEL LIMITS WARNING • Make sure doorway is ON. Severe damage to the opener can restart as many times as necessary to carriage, do so...
Owner's Manual
Page 7
... it approaches the power head to avoid contact with garage door closed ) limit is programmed. 8 Press and hold the up arrow button (+) for 2 seconds until door is fully open ) limit is recommended but not necessary. 6 Press and hold the up arrow button... round LED will begin flashing. PROGRAM SET - HOLD Opening Garage Door (Up Limits) NOTE: Beginning with powerhead. BOTH DOOR LIMITS ARE NOW PROGRAMMED. 7 7/13/12 10 17 AM PROGRAM PROGRAM - + SET The DOWN (closed is programmed. 3 Required Programming 5 Press and release the Program Set button (both LEDs flash ...
... it approaches the power head to avoid contact with garage door closed ) limit is programmed. 8 Press and hold the up arrow button (+) for 2 seconds until door is fully open ) limit is recommended but not necessary. 6 Press and hold the up arrow button... round LED will begin flashing. PROGRAM SET - HOLD Opening Garage Door (Up Limits) NOTE: Beginning with powerhead. BOTH DOOR LIMITS ARE NOW PROGRAMMED. 7 7/13/12 10 17 AM PROGRAM PROGRAM - + SET The DOWN (closed is programmed. 3 Required Programming 5 Press and release the Program Set button (both LEDs flash ...
Owner's Manual
Page 9
... Troubleshooting Section of this process as needed to set force limits. Force and Speed Limits are factory programmed and automatically set themselves when you use the Wall Console to improperly set DOWN limits. Repeat the Setting the Down Limit steps 1-5 to make certain the door is closing tight ... 2 seconds to these functions for the rst time. Repeat this manual (pages 18-19). 10 Open and close your garage door. 3 Required Programming Force and Speed Control These controls are factory set . 12 Lay a 2" x 4" board at under the center of the door. Contact Reverse...
... Troubleshooting Section of this process as needed to set force limits. Force and Speed Limits are factory programmed and automatically set themselves when you use the Wall Console to improperly set DOWN limits. Repeat the Setting the Down Limit steps 1-5 to make certain the door is closing tight ... 2 seconds to these functions for the rst time. Repeat this manual (pages 18-19). 10 Open and close your garage door. 3 Required Programming Force and Speed Control These controls are factory set . 12 Lay a 2" x 4" board at under the center of the door. Contact Reverse...
Owner's Manual
Page 17
... 3. Pull/release cord down and back towards opener and let go ) • Chain/belt drive models: Verify bullet is installed and Limits are not pinched or near moving parts. 1. CORRECTIVE MAINTENANCE Changing Light Bulbs WARNING • Use extreme caution when working from carriage, pull ...and toward the opener. To disengage bullet from a ladder or step stool. • When replacing light cover, make sure wires are programmed. To disengage shuttle from carriage, pull down and toward the door. Remote Battery Replacement Replace remote battery with greater than 60 watts....
... 3. Pull/release cord down and back towards opener and let go ) • Chain/belt drive models: Verify bullet is installed and Limits are not pinched or near moving parts. 1. CORRECTIVE MAINTENANCE Changing Light Bulbs WARNING • Use extreme caution when working from carriage, pull ...and toward the opener. To disengage bullet from a ladder or step stool. • When replacing light cover, make sure wires are programmed. To disengage shuttle from carriage, pull down and toward the door. Remote Battery Replacement Replace remote battery with greater than 60 watts....
Owner's Manual
Page 18
... spring. • Perform monthly a CONTACT REVERSE TEST. Force Settings Force settings are pre programmed at the factory and "learned" during the Open/Close Limit settings steps (see pages 6-7). PROGRAM SET 4 Press either until you reach desired setting. 3 Press and release. PROGRAM SET LED Indication/Result RED OFF BLUE OFF Flashes 3 Times The Current UP...
... spring. • Perform monthly a CONTACT REVERSE TEST. Force Settings Force settings are pre programmed at the factory and "learned" during the Open/Close Limit settings steps (see pages 6-7). PROGRAM SET 4 Press either until you reach desired setting. 3 Press and release. PROGRAM SET LED Indication/Result RED OFF BLUE OFF Flashes 3 Times The Current UP...
Owner's Manual
Page 19
...Adjustments Adjustment Guides (continued) Speed Settings (DC motors only) Speed settings are automatically set to the slowest speed during Limits programming and cannot be adjusted. However, travel speed for OPENING travel will display. Please note that speed may be positioned further...BLUE 2 Press twice. 3 Press and release. Sensor modules CAN be affected by door weight and balance, along with paired Source module. PROGRAM SET 6 Press either until you may not have the option to a slower speed in opposite directions. NOTE: Direct sunlight creates interference with...
...Adjustments Adjustment Guides (continued) Speed Settings (DC motors only) Speed settings are automatically set to the slowest speed during Limits programming and cannot be adjusted. However, travel speed for OPENING travel will display. Please note that speed may be positioned further...BLUE 2 Press twice. 3 Press and release. Sensor modules CAN be affected by door weight and balance, along with paired Source module. PROGRAM SET 6 Press either until you may not have the option to a slower speed in opposite directions. NOTE: Direct sunlight creates interference with...
Owner's Manual
Page 21
...but NOT from remote. • Make certain carriage is completely closed. • Check for normal operation. See page 6. See page 17. • Program remote to close , the opener can cut wires. OR Safe-T-Beam® System malfunction. • If a NEW installation, check Door Arm position. See pages... 21 7/13/12 10 17 AM See page 8, STB instruction, poster or website. • Check if limits are properly set with the garage door hardware or springs, contact The Genie Company at 1-800-35GENIE. See pages 6-7. • Check Sure-Lock™. Sure-Lock™ should be...
...but NOT from remote. • Make certain carriage is completely closed. • Check for normal operation. See page 6. See page 17. • Program remote to close , the opener can cut wires. OR Safe-T-Beam® System malfunction. • If a NEW installation, check Door Arm position. See pages... 21 7/13/12 10 17 AM See page 8, STB instruction, poster or website. • Check if limits are properly set with the garage door hardware or springs, contact The Genie Company at 1-800-35GENIE. See pages 6-7. • Check Sure-Lock™. Sure-Lock™ should be...
Owner's Manual
Page 22
...is lowest speed setting. • If carriage travel . Contact a trained door system technician. Re-program limits, see pages 10-11. Intellicode® 1 remote NOT programmed. Check alignment of door. Wait until LED clears before operating. 22 G999-393 Manual-ScrewBeltChain-EN ... page 10. Limits NOT set properly. Component failure. Check door spring, track, rollers, hinges and fixtures. Thermal cutout Program remote using instructions on a one -piece door. • Contact The Genie Company at 1-800-35GENIE concerning door speed. Remote NOT programmed. Door may need...
...is lowest speed setting. • If carriage travel . Contact a trained door system technician. Re-program limits, see pages 10-11. Intellicode® 1 remote NOT programmed. Check alignment of door. Wait until LED clears before operating. 22 G999-393 Manual-ScrewBeltChain-EN ... page 10. Limits NOT set properly. Component failure. Check door spring, track, rollers, hinges and fixtures. Thermal cutout Program remote using instructions on a one -piece door. • Contact The Genie Company at 1-800-35GENIE concerning door speed. Remote NOT programmed. Door may need...