Replacing the Server Module Board
Page 3
Contents Required Tools 1-1 Parts Kit 1-1 Before You Begin 1-2 Turning Off the Server Module 1-2 Verifying the Hard-Drive Mirroring Mode 1-3 Manually Deconfiguring Mirrored Mode 1-4 Replacing the Server Module Board 1-6 Removing the Server Module 1-6 Opening the Server Module 1-7 Removing Memory Modules 1-8 Removing a Processor 1-10 Removing ...1-14 Closing the Server Module 1-14 Installing a Server Module 1-15 Verifying the System Setup Options 1-15 Running the PERC 4/im DOS Utility 1-16 Manually Configuring the Mirroring Mode 1-16 Programming the Service Tag 1-18 Contents 3
Contents Required Tools 1-1 Parts Kit 1-1 Before You Begin 1-2 Turning Off the Server Module 1-2 Verifying the Hard-Drive Mirroring Mode 1-3 Manually Deconfiguring Mirrored Mode 1-4 Replacing the Server Module Board 1-6 Removing the Server Module 1-6 Opening the Server Module 1-7 Removing Memory Modules 1-8 Removing a Processor 1-10 Removing ...1-14 Closing the Server Module 1-14 Installing a Server Module 1-15 Verifying the System Setup Options 1-15 Running the PERC 4/im DOS Utility 1-16 Manually Configuring the Mirroring Mode 1-16 Programming the Service Tag 1-18 Contents 3
Replacing the Server Module Board
Page 8
...you are installed in your Installation and Troubleshooting Guide. See "Troubleshooting Hard Drives" in mirrored mode: HBA ID LUN VENDOR PRODUCT 0 00 Dell VIRTUAL DISK 0 70 LSI Logic 1020/1030 REV 1000 1000c00 SYNC 320.0 WIDE 16 16 CAPACITY 18203 MB Table 1-1 lists the possible...mirrored mode and the actions required. NOTICE: If this message is displayed, press immediately before the server module boots to "Manually Deconfiguring Mirrored Mode." The following is faulty. Mir rored Mode Messages and Actions Message Action Logical drive optimal Go to reboot the server...
...you are installed in your Installation and Troubleshooting Guide. See "Troubleshooting Hard Drives" in mirrored mode: HBA ID LUN VENDOR PRODUCT 0 00 Dell VIRTUAL DISK 0 70 LSI Logic 1020/1030 REV 1000 1000c00 SYNC 320.0 WIDE 16 16 CAPACITY 18203 MB Table 1-1 lists the possible...mirrored mode and the actions required. NOTICE: If this message is displayed, press immediately before the server module boots to "Manually Deconfiguring Mirrored Mode." The following is faulty. Mir rored Mode Messages and Actions Message Action Logical drive optimal Go to reboot the server...
Replacing the Server Module Board
Page 19
... the server module. If the service tag information is correct. If the server module does not turn on, see "Programming the Service Tag." 4 Press to "Manually Configuring the Mirroring Mode." NOTE: The server module upgrade is complete. 4 If the server module was configured with one hard drive or two hard drives...
... the server module. If the service tag information is correct. If the server module does not turn on, see "Programming the Service Tag." 4 Press to "Manually Configuring the Mirroring Mode." NOTE: The server module upgrade is complete. 4 If the server module was configured with one hard drive or two hard drives...
Replacing the Server Module Board
Page 20
... diskette drive to the front of the server module. 2 Insert the PERC 4/im DOS Utility diskette. 3 Turn on the server module. Manually Configuring the Mirroring Mode NOTE: Perform this procedure only if you received the message Logical drive resynchronizing while verifying the mirroring mode and you...You must press . 1-16 Replacing the Server Module Board The server module reboots. 9 Remove the PERC 4/im DOS Utility diskette. www.dell.com | support.dell.com Running the PERC 4/im DOS Utility NOTICE: You must run this utility during POST: Press CTRL-M to start LSI logic configuration utility...
... diskette drive to the front of the server module. 2 Insert the PERC 4/im DOS Utility diskette. 3 Turn on the server module. Manually Configuring the Mirroring Mode NOTE: Perform this procedure only if you received the message Logical drive resynchronizing while verifying the mirroring mode and you...You must press . 1-16 Replacing the Server Module Board The server module reboots. 9 Remove the PERC 4/im DOS Utility diskette. www.dell.com | support.dell.com Running the PERC 4/im DOS Utility NOTICE: You must run this utility during POST: Press CTRL-M to start LSI logic configuration utility...
Replacing the Server Module Board
Page 21
... this menu and then press . 9 Press to exit the Adapter Properties Menu. 10 Press to Primary and Secondary. This indicates that the drives are in "Manually Deconfiguring Mirrored Mode." 6 Ensure that you select the same SCSI ID that the drive fields are listed with their SCSI IDs: SCSI ID 0 1 Device Fujitsu... reboots. REV 1000 1000c00 SYNC 320.0 WIDE 16 16 CAPACITY 18203 MB Replacing the Ser ver Module Board 1-17 HBA ID LUN VENDOR PRODUCT 0 00 Dell VIRTUAL DISK 0 70 LSI Logic 1020/1030 The server module upgrade is complete.
... this menu and then press . 9 Press to exit the Adapter Properties Menu. 10 Press to Primary and Secondary. This indicates that the drives are in "Manually Deconfiguring Mirrored Mode." 6 Ensure that you select the same SCSI ID that the drive fields are listed with their SCSI IDs: SCSI ID 0 1 Device Fujitsu... reboots. REV 1000 1000c00 SYNC 320.0 WIDE 16 16 CAPACITY 18203 MB Replacing the Ser ver Module Board 1-17 HBA ID LUN VENDOR PRODUCT 0 00 Dell VIRTUAL DISK 0 70 LSI Logic 1020/1030 The server module upgrade is complete.
Server Module Board Replacement (Restoring Integrated Mirroring)
Page 3
...system, but do not turn on your server module to the video connector on the server module. See "Installing a Server Module" in the system Service Manual. 2 Replace the server module board. The utility should be run on all server modules that server module attempts to boot to add another hard drive...mirrored hard drives and that have two hard drives because you cannot tell their state until step 6. 3 Install the server module in the system Service Manual. The utility should be run , your server module will not function properly. See "Removing a Server Module" in the system Service...
...system, but do not turn on your server module to the video connector on the server module. See "Installing a Server Module" in the system Service Manual. 2 Replace the server module board. The utility should be run on all server modules that server module attempts to boot to add another hard drive...mirrored hard drives and that have two hard drives because you cannot tell their state until step 6. 3 Install the server module in the system Service Manual. The utility should be run , your server module will not function properly. See "Removing a Server Module" in the system Service...