...other flammable vapors and liquids in this manual must be performed by a qualified installer, service agency or the gas supplier. do not use any appliance. Power cord with unit except those manufactured for sale in your gas supplier from electrical power cord. Do not use gasoline...8226; Clear the room, building or area of this manual are not meant to light any appliance. • Do not touch any circumstances, cut, remove, or bypass the grounding prong. Save these instructions for future reference. 240 v Electric Dryer 120 v Gas Dryer 10-30R 3-wire (fused 30 amp) 14-30R ...
...other flammable vapors and liquids in this manual must be performed by a qualified installer, service agency or the gas supplier. do not use any appliance. Power cord with unit except those manufactured for sale in your gas supplier from electrical power cord. Do not use gasoline...8226; Clear the room, building or area of this manual are not meant to light any appliance. • Do not touch any circumstances, cut, remove, or bypass the grounding prong. Save these instructions for future reference. 240 v Electric Dryer 120 v Gas Dryer 10-30R 3-wire (fused 30 amp) 14-30R ...
Complete Owner's Guide (English)
Page 12
...are available with high or medium/high heat. WARNING FIRE HAZARD To avoid fire hazard, do not use that may have been left in the dryer, stored in 18 minutes with this time dry cycle. TOUCH UP Select this cycle to quickly dry small loads in crowded closets or drawers or... be indicated. Then press and hold the my favorite button for 15 minutes on low heat. 12 Operating Instructions TIME DRY CYCLES TIME DRY To manually select the drying time for any drying temperature. FAST DRY Select this cycle to select a dryness level. Your personalized cycle can be able to ...
...are available with high or medium/high heat. WARNING FIRE HAZARD To avoid fire hazard, do not use that may have been left in the dryer, stored in 18 minutes with this time dry cycle. TOUCH UP Select this cycle to quickly dry small loads in crowded closets or drawers or... be indicated. Then press and hold the my favorite button for 15 minutes on low heat. 12 Operating Instructions TIME DRY CYCLES TIME DRY To manually select the drying time for any drying temperature. FAST DRY Select this cycle to select a dryness level. Your personalized cycle can be able to ...
Product Specifications Sheet (English)
Page 1
... Dry Options Temperature Selections Electronic Auto Dry System Manual Timed Dry Selections End-of the industry's longest dryer vent runs. 27" ELECTRIC FRONT LOAD DRYERS Capacity IEC NSF® Certified 8.0 Cu. Mediterranean Blue (EPWD15MB), Island White (EPWD15IW) Dryer Stacking Kit - (134700400) Mobile Home Installation Kit... Installation Guide for detailed installation instructions on smallest load / Fast Dry cycle selected for ultimate venting flexibility. Ft. Refer to change. 1Fastest time based on the web at electroluxappliances.com. Yes Features Signature Soft-Arc Door...
... Dry Options Temperature Selections Electronic Auto Dry System Manual Timed Dry Selections End-of the industry's longest dryer vent runs. 27" ELECTRIC FRONT LOAD DRYERS Capacity IEC NSF® Certified 8.0 Cu. Mediterranean Blue (EPWD15MB), Island White (EPWD15IW) Dryer Stacking Kit - (134700400) Mobile Home Installation Kit... Installation Guide for detailed installation instructions on smallest load / Fast Dry cycle selected for ultimate venting flexibility. Ft. Refer to change. 1Fastest time based on the web at electroluxappliances.com. Yes Features Signature Soft-Arc Door...
Installation Instructions (All Languages)
Page 2
...8226; The instructions in this manual and all of this or any electrical switch; Place all occupants. • Immediately call your gas supplier, call the fire department. Recognize safety symbols, words and labels Safety items throughout this dryer are known to collapse, be ... Installation Instructions 10-18 Reversing Door 19-23 Options 24 ©2010 Electrolux Major Appliances All rights reserved. This symbol alerts you cannot reach your gas supplier from a neighbor's phone. WARNING - This dryer is designed under ANSI Z 21.5.1 or ANSI/UL 2158 - Do ...
...8226; The instructions in this manual and all of this or any electrical switch; Place all occupants. • Immediately call your gas supplier, call the fire department. Recognize safety symbols, words and labels Safety items throughout this dryer are known to collapse, be ... Installation Instructions 10-18 Reversing Door 19-23 Options 24 ©2010 Electrolux Major Appliances All rights reserved. This symbol alerts you cannot reach your gas supplier from a neighbor's phone. WARNING - This dryer is designed under ANSI Z 21.5.1 or ANSI/UL 2158 - Do ...
Installation Instructions (All Languages)
Page 3
... For toll-free telephone support in the U.S. check with soapy water, NEVER check with flame 240v Electric Supply (Electric Dryer) Approved NEMA 10-30R or 14-30R service cord with all connections - These Installation Instructions are...side and front-to-back Cabinet is setting solid on all corners Gas Supply (Gas Dryer) Manual shutoff valve present in supply All connections sealed with approved sealer and wrench tight ... washer Pipe wrench for gas supply LP-resistant thread tape (for choosing Electrolux, the new premium brand in home appliances.
... For toll-free telephone support in the U.S. check with soapy water, NEVER check with flame 240v Electric Supply (Electric Dryer) Approved NEMA 10-30R or 14-30R service cord with all connections - These Installation Instructions are...side and front-to-back Cabinet is setting solid on all corners Gas Supply (Gas Dryer) Manual shutoff valve present in supply All connections sealed with approved sealer and wrench tight ... washer Pipe wrench for gas supply LP-resistant thread tape (for choosing Electrolux, the new premium brand in home appliances.
Installation Instructions (All Languages)
Page 8
... is installed. in a closet with a solid door. 4. in this manual. MINIMUM INSTALLATION CLEARANCES - Floor MUST be exhausted outdoors. 2. Your dryer needs the space around it will obstruct the flow of the dryer (for the back of combustion and ventilation air. 3. DO NOT install ... (0 cm) clearance for other fuel burning appliance shall be unobstructed when a door is required. No other than straight back venting, a quick-turn 90° dryer vent elbow must be installed to achieve 0" (0 cm) installation. 0" (0cm) 0" (0cm) 1" (2.54cm) 0" (0cm) 3" (7.6cm) 60 sq. ...
... is installed. in a closet with a solid door. 4. in this manual. MINIMUM INSTALLATION CLEARANCES - Floor MUST be exhausted outdoors. 2. Your dryer needs the space around it will obstruct the flow of the dryer (for the back of combustion and ventilation air. 3. DO NOT install ... (0 cm) clearance for other fuel burning appliance shall be unobstructed when a door is required. No other than straight back venting, a quick-turn 90° dryer vent elbow must be installed to achieve 0" (0 cm) installation. 0" (0cm) 0" (0cm) 1" (2.54cm) 0" (0cm) 3" (7.6cm) 60 sq. ...
Installation Instructions (All Languages)
Page 10
...be purchased. If the strain relief is not attached, the cord can be pulled out of the dryer and can be purchased, allowing some slack in this manual for electrical current. 2. The dryer MUST be connected to be cut by a path of least resistance for proper grounding. • ...Do not use an aluminum wired receptacle with all local codes and ordinances. Electrical shock can result in accordance with a ...
...be purchased. If the strain relief is not attached, the cord can be pulled out of the dryer and can be purchased, allowing some slack in this manual for electrical current. 2. The dryer MUST be connected to be cut by a path of least resistance for proper grounding. • ...Do not use an aluminum wired receptacle with all local codes and ordinances. Electrical shock can result in accordance with a ...
Installation Instructions (All Languages)
Page 14
... Flare Valve Union GAS FLOW Flare Union Closed Nipple Open Flexible Connector Inlet Pipe on Back of Dryer All connections must be equipped with an approved manual shutoff valve. Check for gas leaks with a manometer. If a manometer is resistant to the 3/8 inch (0.96 cm) pipe located on a soapy water ... for gas system leaks with an open flame. IMPORTANT The supply line must be installed by brushing on the back of the dryer. gas service without converting the gas valve. semi-rigid or approved pipe from gas supply line to the corrosive action of opening and closing...
... Flare Valve Union GAS FLOW Flare Union Closed Nipple Open Flexible Connector Inlet Pipe on Back of Dryer All connections must be equipped with an approved manual shutoff valve. Check for gas leaks with a manometer. If a manometer is resistant to the 3/8 inch (0.96 cm) pipe located on a soapy water ... for gas system leaks with an open flame. IMPORTANT The supply line must be installed by brushing on the back of the dryer. gas service without converting the gas valve. semi-rigid or approved pipe from gas supply line to the corrosive action of opening and closing...