Wiring Diagram (All Languages)
Page 1
...any resulting E65 Thermostat trip count too high Thermostat defective or Inlet Thermal damage. Replace motor. If no failure code experienced. 3. Wake the dryer up to 30 minutes to reset). NOTE: E00 means no further damage is pressed, check for open circuit... Control Board defective Replace Electronic Control Board and retest. 1 137032700B (0209) CAUTION: DISCONNECT ELECTRICAL CURRENT BEFORE SERVICING Please Return This Sheet to the cabinet. Error Code Fault E31 Contact Sensor frequency too high E32 Contact Sensor frequency too low E42 Door Sensing ...
...any resulting E65 Thermostat trip count too high Thermostat defective or Inlet Thermal damage. Replace motor. If no failure code experienced. 3. Wake the dryer up to 30 minutes to reset). NOTE: E00 means no further damage is pressed, check for open circuit... Control Board defective Replace Electronic Control Board and retest. 1 137032700B (0209) CAUTION: DISCONNECT ELECTRICAL CURRENT BEFORE SERVICING Please Return This Sheet to the cabinet. Error Code Fault E31 Contact Sensor frequency too high E32 Contact Sensor frequency too low E42 Door Sensing ...
Wiring Diagram (All Languages)
Page 2
... and/or console. INSTALLATION CYCLE 1. DIAGNOSTIC MODE 1. Within 10 seconds after pressing "cancel", press any load from the dryer and press "start pause" to enter standby mode and enable diagnostic entry. 2. E74 Inlet Control Thermistor short circuit Inlet Control... Electronic Control Board defective EF3 Max Timeout Timer Exhaust blocked; Replace Outlet Control Thermistor and/or wiring and retest. Error Code E71 Fault Outlet Control Thermistor open circuit Outlet Control E72 Thermistor short circuit Possible Fault Conditions Outlet Control Thermistor or...
... and/or console. INSTALLATION CYCLE 1. DIAGNOSTIC MODE 1. Within 10 seconds after pressing "cancel", press any load from the dryer and press "start pause" to enter standby mode and enable diagnostic entry. 2. E74 Inlet Control Thermistor short circuit Inlet Control... Electronic Control Board defective EF3 Max Timeout Timer Exhaust blocked; Replace Outlet Control Thermistor and/or wiring and retest. Error Code E71 Fault Outlet Control Thermistor open circuit Outlet Control E72 Thermistor short circuit Possible Fault Conditions Outlet Control Thermistor or...
Wiring Diagram (All Languages)
Page 3
Selector Position 0 Test/Activated Component Electric Gas Lights / Buttons test 1 Motor Clockwise (CW) 2 Contact Sensor Diagnostic Mode Operator Check LCD row Check Motor function. Press all buttons and ...5 Motor CW + Heater 1 Motor CW + Heater Check Motor and Heater function. NTC1" display. 8 Motor Clockwise (CW) "MOTOR CW" 9 Error code history display Check last 5 error codes displayed (See Table above for error code definitions) 10 Software version Software version Software version LCD digits "1111" if Contact Sensor open circuit;"8888" if Contact Sensor short...
Selector Position 0 Test/Activated Component Electric Gas Lights / Buttons test 1 Motor Clockwise (CW) 2 Contact Sensor Diagnostic Mode Operator Check LCD row Check Motor function. Press all buttons and ...5 Motor CW + Heater 1 Motor CW + Heater Check Motor and Heater function. NTC1" display. 8 Motor Clockwise (CW) "MOTOR CW" 9 Error code history display Check last 5 error codes displayed (See Table above for error code definitions) 10 Software version Software version Software version LCD digits "1111" if Contact Sensor open circuit;"8888" if Contact Sensor short...