Question posted by LizzMe on December 9th, 2013

Can A Clogged Dryer Vent Cause A Error Code 64

The person who posted this question about this Electrolux product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

Answer #1: Posted by OnlineOutreachSpecialist on January 3rd, 2014 8:31 AM
This answer was accepted by the poster of the original question.
OnlineOutreachSpecialist

Member since:
March 30th, 2011

Points: 2,848,320
1,110
points
Hello LizzMe, thank you for your post!

That is a good question! An error code E64 is associated with the heater circuit in the open position. A technician would typically check the heater coils and connections for short circuits to the cabinet to determine if it is the cause of the error code. Depending on the readings, the heater and/or wiring will need replacing. This is not a normal DIY job so you may want to connect with a local servicer to determine the exact diagnosis to help reduce the risk of unnecessary parts. I hope this helps explain the error code you are receiving.

Best regards!

Chris


Online Outreach Specialist

Related Electrolux EIED55HIW Manual Pages

Complete Owner's Guide (English) - Page 3

...Use and Care Guide, Installation Instructions and on electric dryers (not provided with unit except those manufactured for future reference. 240 v Electric Dryer 120 v Gas Dryer 10-30R 3-wire (fused 30 amp) ... flammable vapors and liquids in your appliance. Safety items throughout this warning can cause serious injury, fire or death. NOTE The instructions appearing in this or any...
Complete Owner's Guide (English) - Page 4

...cause a load to comply with gasoline, cleaning solvents, kerosene, waxes, etc. Close supervision of all warnings on or in serious personal injuries. As children grow, teach them for play on product labels. • Before the dryer...chambers. • Keep laundry products out of fire, electrical shock, or injury to persons when using this dryer, comply with cooking ...
Complete Owner's Guide (English) - Page 5

... factory parts. • Do not tamper with local codes. If the dryer is moving. Do not use any service or cleaning. Safety 5 Important Safety Instructions, con't PREVENT INJURY • To prevent shock hazard and assure stability during operation, the dryer must be installed and electrically grounded by a qualified service person in accordance with controls...
Complete Owner's Guide (English) - Page 9

NOTE Over-drying can cause wrinkles, shrinkage, lint, harshness and a build up of the cycle if the chime option has been selected. See the "Dryer Settings Chart" for 5 seconds. 5. To change ... for the cycle selected, the indicator will no longer be displayed at the end of static electricity. To interrupt the cycle, press pause; Select the appropriate cycle and settings for Time Dry...
Complete Owner's Guide (English) - Page 16

...cycle, drying temperature, dryness level and options. Check fabric care labels to prevent damage caused by NSF International®, an independent, third-party testing and certification organization dedicated to ... can be selected with wrinkle release to add another 30 minutes of Residential Clothes Dryers Saving Favorites To program a cycle with no carryover of 45 minutes. 16 Operating...
Complete Owner's Guide (English) - Page 19

...Important Safety Instructions and those listed below. • Before cleaning the dryer interior, unplug the electrical power cord to avoid electrical shock hazards. • Do not use any accumulation of lint ...air flow, which causes longer drying times. Dry the filter thoroughly and replace. Do not operate the dryer without the lint filter in place. • If the dryer drum becomes stained ...
Complete Owner's Guide (English) - Page 20

...off, ball up and cling to fabric.) Shrinking Wrinkling POSSIBLE CAUSES • Fabric softener sheet. • Overloading. • Overdrying causes static electricity. • Lint screen not clean when cycle began. .... • Follow fabric care label directions. • If shrinking is clean and in dryer after cycle ends. Rinse and rewash. • Add a few bath towels to small loads...
Complete Owner's Guide (English) - Page 21

... or replace fuse. Drying time will not operate. (electric models) Gas supply valve is blown, the drum may be clogged or restricted. It may be loose. Outside exhaust hood or exhaust duct may save both time and expense. POSSIBLE CAUSE SOLUTION Electrical power cord is restored. Dryer runs but the heater will be at the...
Wiring Diagram (All Languages) - Page 1

... (0209) Wake the dryer up to 30 minutes to reset). To view the last 5 error codes recorded, refer to motor relay output (J3-1) with vent restrictions, check/replace High...tripped (Electric Model only) problems are found with power applied check for continuity. If no further damage is pressed, check for Future Reference Contents Page Error code explanation 1 Error Code Chart ...
Wiring Diagram (All Languages) - Page 2

...10 seconds after pressing "cancel", press any load from the dryer and press "start pause" to the far left cycle and...be between Electronic Control Board and Interface Board. Error Code E71 Fault Outlet Control Thermistor open circuit Outlet...Board defective Replace Electronic Control Board. High vent restriction, Exhaust Control Check vent restrictions and resistance values of Exhaust Control ...
Wiring Diagram (All Languages) - Page 3

...Component Electric Gas Lights / Buttons test 1 Motor Clockwise (CW) 2 Contact Sensor Diagnostic Mode Operator Check LCD row Check Motor function. NTC1" 6 Motor CW + Heater 1 + Heater 2 Motor CW + Heater Check Motor and Heater function. Check Inlet Control Thermistor value in digit display. "HEAT2 - NTC1" display. 8 Motor Clockwise (CW) "MOTOR CW" 9 Error code history...
Product Specifications Sheet (English) - Page 1

...national electric codes. Gentle Tumble™ Dry System Our exclusive dryer design gently separates and tumbles clothes for detailed installation instructions on manufacturer specifications. Ft. Yes...dryer vent runs. 27" ELECTRIC FRONT LOAD DRYERS Capacity IEC NSF® Certified 8.0 Cu. Refer to change. 1Fastest time based on smallest load / Fast Dry cycle selected for ultimate venting...
Product Specifications Sheet (English) - Page 2

...to Built-In Installations on web.) • Closet installation requires vented door with matching Electrolux Washer in installations. Dryer 90° Countertop 54" min. 90° 38" ...on web.) • Always consult local and /or national electric codes. • Can be installed alone, with or without notice. Electric Dryer Specifications • Product Weight - 130 Lbs. • Voltage...
Installation Instructions (All Languages) - Page 2

...• Do not install a clothes dryer with a WARNING or CAUTION based on top of life. Flexible venting materials are known to situations that may cause bodily injury or property damage. CAN/CSA... become airtight chambers causing suffocation. Do not store or use any phone in Canada, the Canadian electrical code C22.1 part 1. • The gas service to the dryer must be easily ...
Installation Instructions (All Languages) - Page 5

... conditions will corrode when subjected to natural gas, causing gas leaks. Correct Incorrect If your present system is made up of your dryer to the gas supply line. Use ONLY black ...duct and approved vent hood which has a swing-out damper(s) that open when the dryer is free of 1/2 psig (3.45 kPa). 7. Installation MUST conform with local codes, or in operation. The dryer MUST be easily...
Installation Instructions (All Languages) - Page 6

... hazard, as well as increasing drying times. An accumulation of lint in the surrounding area. Dryer vent elbows are available through your local parts distributor or hardware store. See also CLEARANCE REQUIREMENTS on the screws or rivets, clogging the duct work and creating a fire hazard as well as increase drying times. Do...
Installation Instructions (All Languages) - Page 7

... with no obstructions. Installation Requirements 7 Exhaust system requirements, continued WARNING EXPLOSION HAZARD Do not install the dryer where gasoline or other important exhaust venting system requirements. 5. Failure to air fluff (cool down drafts causing an increase in vent restriction. • Running the exhaust system through the floor and area beneath the mobile...
Installation Instructions (All Languages) - Page 8

... REAR TOP FRONT Alcove 0" (0 cm) 0" (0 cm)* 0" (0 cm) n/a UnderCounter 0" (0 cm) 0" (0 cm)* 0" (0 cm) n/a Closet 0" (0 cm) 0" (0 cm)* 0" (0 cm) 1" (2.54 cm) * For other than straight back venting), a quick-turn 90° dryer vent elbow must be solid with a solid door. 4. in a bedroom, bathroom, recess or closet, MUST be installed to dripping water or outside weather conditions...
Installation Instructions (All Languages) - Page 10

... of a malfunction or breakdown, grounding will not fit the outlet, have longer drying times than dryers operating on 208 volt power supply will have a proper outlet installed by a path of the equipment grounding conductor can cause electrical shorts. If the strain relief is not properly grounded. DO NOT modify the plug you've...
Installation Instructions (All Languages) - Page 24

...of matching washer may be available. WARNING ELECTRICAL HAZARD Label all wires prior to aid in mobile homes require use of this dryer may be used to the height of ...P/N 5304468812 Mediterranean Blue Touch Up Pen - Wiring errors can cause improper and dangerous operation. P/N EPWD15KG A storage pedestal accessory, specifically designed for this dryer. If your unit for ease of 53" ...

Similar Questions

How Do I Clear The Error Code E66 After I Replace The Parts That I Have Put In ?
I have had the thermal limiter replaced and the high heat limiter and I keep getting the errorcode E...
(Posted by diladyjon57 10 years ago)
Error Code E92
I have an Electrolux EIED55HIW electric dryer. I have had it for 1 year and 1 month so it is not cov...
(Posted by kevconvt 13 years ago)
Ask a New Question
Use the box below to post a new question about this Electrolux product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Electrolux Manuals

Find free Electrolux EIED55HIW - 8.0 cu. Ft. Electric Dryer manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Electrolux Reviews

View thousands of Electrolux user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Electrolux customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Electrolux customer service rankings, employee comments and much more from our sister site.

Electrolux Recalls

Find comprehensive Electrolux recall information updated hourly on RecallOwl.com.