...STARTED...7 FOR THE OPERATOR OVERVIEW OF FLOW OF DAILY SALES ENTRIES 11 BASIC SALES ENTRY ...12 1 Basic Sales Entry Example ...12 2 Error Warning ...13 3 Item Entries ...14 Single item entries ...14 Repeat entries ...15 Multiplication entries ...15 Split pricing entries ...16 Single item... cash sale (SICS) entry 17 4 Displaying Subtotal...17 5 Finalization of Transaction ...17 Cash or check tendering...17 Cash or check sale that does not require tender entry 18 Charge (credit) sale ...18 ...
...STARTED...7 FOR THE OPERATOR OVERVIEW OF FLOW OF DAILY SALES ENTRIES 11 BASIC SALES ENTRY ...12 1 Basic Sales Entry Example ...12 2 Error Warning ...13 3 Item Entries ...14 Single item entries ...14 Repeat entries ...15 Multiplication entries ...15 Split pricing entries ...16 Single item... cash sale (SICS) entry 17 4 Displaying Subtotal...17 5 Finalization of Transaction ...17 Cash or check tendering...17 Cash or check sale that does not require tender entry 18 Charge (credit) sale ...18 ...
XE-A202 Operation Manual in English and Spanish
Page 5
...Miscellaneous Key Programming ...35 % & V Rate for , and ...35 - Amount for ...36 % & Percent rate limitation for service ...67 Error code table ...67 SPECIFICATIONS ...68 MANUAL DE INSTRUCCIONES (VERSION EN ESPAÑOL) 3 BASIC FUNCTION PROGRAMMING (For Quick Start 27 1 Date ... Function 28 Tax programming using as CA key 38 4 Text programming ...39 ADVANCED PROGRAMMING ...44 1 Register Number and Consecutive Number Programming 44 2 Electronic Journal (EJ) Programming 45 3 Various Function Selection Programming 1 47 Function selection for miscellaneous keys 47 Print...
...Miscellaneous Key Programming ...35 % & V Rate for , and ...35 - Amount for ...36 % & Percent rate limitation for service ...67 Error code table ...67 SPECIFICATIONS ...68 MANUAL DE INSTRUCCIONES (VERSION EN ESPAÑOL) 3 BASIC FUNCTION PROGRAMMING (For Quick Start 27 1 Date ... Function 28 Tax programming using as CA key 38 4 Text programming ...39 ADVANCED PROGRAMMING ...44 1 Register Number and Consecutive Number Programming 44 2 Electronic Journal (EJ) Programming 45 3 Various Function Selection Programming 1 47 Function selection for miscellaneous keys 47 Print...
XE-A202 Operation Manual in English and Spanish
Page 8
...full. Refer to page 63 for repetitive registrations: The number of a transaction when the electronic journal (EJ) memory is not set or out. 6 Drawer Lock Key This key locks and unlocks the drawer. SK1-1 6 When you have registered ten times, the display will show "0."(2 → 3 ..... 9 → 0 ...or hour-minute -" ") in the far-right eight (max.) positions. Machine state symbols : Appears during programming. : Appears when an error is detected. : Appears when the subtotal is displayed or when the amount tendered is negative, the minus symbol "-" appears before the amount...
...full. Refer to page 63 for repetitive registrations: The number of a transaction when the electronic journal (EJ) memory is not set or out. 6 Drawer Lock Key This key locks and unlocks the drawer. SK1-1 6 When you have registered ten times, the display will show "0."(2 → 3 ..... 9 → 0 ...or hour-minute -" ") in the far-right eight (max.) positions. Machine state symbols : Appears during programming. : Appears when an error is detected. : Appears when the subtotal is displayed or when the amount tendered is negative, the minus symbol "-" appears before the amount...
XE-A202 Operation Manual in English and Spanish
Page 15
...code 1 to 25 L LL Receipt ON/OFF function When you use the error escape function as shown below: To clear the error state Transaction l E E The transaction is voided (treated as a cash sale. 13 When your register goes to see if the entered amount is correct, it can disable receipt ...printing in the REG mode to save mode, it is correct. Please note when your register is recovered by ...
...code 1 to 25 L LL Receipt ON/OFF function When you use the error escape function as shown below: To clear the error state Transaction l E E The transaction is voided (treated as a cash sale. 13 When your register goes to see if the entered amount is correct, it can disable receipt ...printing in the REG mode to save mode, it is correct. Please note when your register is recovered by ...
XE-A202 Operation Manual in English and Spanish
Page 23
... discount amount to both individual items and merchandise subtotal. When entry limit is programmed for a percent key, you can not enter a rate over the limit (error code 34 will occur.) Percent calculation for the merchandise subtotal Key operation example 4 @ 140 > 570 * m 10 % A Print Percent calculation for item ...amounts, enter the amount with the numeric keys (you need a decimal point when you can not enter an amount over the limit (error code 34 will occur.) 21 When entry digit limit is programmed for the key) Print Discount and premium entries using the discount key The...
... discount amount to both individual items and merchandise subtotal. When entry limit is programmed for a percent key, you can not enter a rate over the limit (error code 34 will occur.) Percent calculation for the merchandise subtotal Key operation example 4 @ 140 > 570 * m 10 % A Print Percent calculation for item ...amounts, enter the amount with the numeric keys (you need a decimal point when you can not enter an amount over the limit (error code 34 will occur.) 21 When entry digit limit is programmed for the key) Print Discount and premium entries using the discount key The...
XE-A202 Operation Manual in English and Spanish
Page 28
... be corrected by the Direct or Indirect Void Function Any errors found after the entry of Incorrect Entries not Handled by the manager. Make correct entries from the beginning. 3. Once subtotal void is executed, the transaction is aborted and the register issues a receipt. This function does not work when more than 30...
... be corrected by the Direct or Indirect Void Function Any errors found after the entry of Incorrect Entries not Handled by the manager. Make correct entries from the beginning. 3. Once subtotal void is executed, the transaction is aborted and the register issues a receipt. This function does not work when more than 30...
XE-A202 Operation Manual in English and Spanish
Page 32
....9999%) M max. Then program again from the beginning. • Limitations to its decimal equivalent (i.e. .375) and the resulting rate of breakpoints exceeds the register's table capacity, then the manual entry approach should be entered and the preceding minimum breakpoint is $1.00 or more than $1.00 or more .) If the... s key; five digits @ Repeat until the MAX point is not less than 99¢, enter "0" or nothing. and if you make an error after the decimal point) but you do not need to enter the trailing zeros of the tax rate (after entering the M, cancel it is to...
....9999%) M max. Then program again from the beginning. • Limitations to its decimal equivalent (i.e. .375) and the resulting rate of breakpoints exceeds the register's table capacity, then the manual entry approach should be entered and the preceding minimum breakpoint is $1.00 or more than $1.00 or more .) If the... s key; five digits @ Repeat until the MAX point is not less than 99¢, enter "0" or nothing. and if you make an error after the decimal point) but you do not need to enter the trailing zeros of the tax rate (after entering the M, cancel it is to...
XE-A202 Operation Manual in English and Spanish
Page 51
... printing for conversion of hourly sales total data in void mode Selection: Entry: (Fixed position) 0 By lock error* 0 By misoperation 1 Allow to 3 (default 2) Job code: 62 * Item: A B C D E F G H Always enter 0. unit price is selected. Error beep activation Key touch sound availability Buffered keyboard Void mode operation availability Void mode entry data print in...
... printing for conversion of hourly sales total data in void mode Selection: Entry: (Fixed position) 0 By lock error* 0 By misoperation 1 Allow to 3 (default 2) Job code: 62 * Item: A B C D E F G H Always enter 0. unit price is selected. Error beep activation Key touch sound availability Buffered keyboard Void mode operation availability Void mode entry data print in...
XE-A202 Operation Manual in English and Spanish
Page 63
... been programmed not to the MGR position. 2. OVERRIDE ENTRIES Programmed limit for functions (such as for the incorrect receipt are removed from register memory; Make an override entry. Turn the mode switch to the VOID position using the manager key (MA), to the void-mode transaction totalizer.) REG ... X1/Z1 X2/Z2 discounts entries over $1.00. Return the mode switch to the MGR position. 250 - Key operation example REG-mode entries 1500 # - 250 ...Error l Print Turn the mode switch to the REG position.
... been programmed not to the MGR position. 2. OVERRIDE ENTRIES Programmed limit for functions (such as for the incorrect receipt are removed from register memory; Make an override entry. Turn the mode switch to the VOID position using the manager key (MA), to the void-mode transaction totalizer.) REG ... X1/Z1 X2/Z2 discounts entries over $1.00. Return the mode switch to the MGR position. 250 - Key operation example REG-mode entries 1500 # - 250 ...Error l Print Turn the mode switch to the REG position.
XE-A202 Operation Manual in English and Spanish
Page 64
... arm until you want to keep a permanent record, copy the printed text with glue, thinner or a freshly copied blueprint, and heat caused by SHARP. • Do not unpack the thermal paper until it . • Avoid heat. Avoid direct sunlight. • The printed text on the paper ...power recovery. • When power failure is encountered during a printing cycle, the register prints "========" and then carries out the correct printing procedure after power recovery. (See the sample print.) 2 In Case of Printer Error If the printer runs out of the print head and print roller. Refer to ...
... arm until you want to keep a permanent record, copy the printed text with glue, thinner or a freshly copied blueprint, and heat caused by SHARP. • Do not unpack the thermal paper until it . • Avoid heat. Avoid direct sunlight. • The printed text on the paper ...power recovery. • When power failure is encountered during a printing cycle, the register prints "========" and then carries out the correct printing procedure after power recovery. (See the sample print.) 2 In Case of Printer Error If the printer runs out of the print head and print roller. Refer to ...
XE-A202 Operation Manual in English and Spanish
Page 69
...Action Make a correct key entry. Make a tendering operation. Make a correct key entry. Error code table l When the following error codes are displayed, press the key and take a proper action according to the register? • Is the mode switch set properly at the "REG" position? • ... within 25 steps. Make a preset price entry. Enter a correct code a Program the key within a limit of a clerk code Overflow limitation error The open price entry. Finalize the transaction, and correct the wrong entries in the void mode. 67 Subtotal void is full (in the key ...
...Action Make a correct key entry. Make a tendering operation. Make a correct key entry. Error code table l When the following error codes are displayed, press the key and take a proper action according to the register? • Is the mode switch set properly at the "REG" position? • ... within 25 steps. Make a preset price entry. Enter a correct code a Program the key within a limit of a clerk code Overflow limitation error The open price entry. Finalize the transaction, and correct the wrong entries in the void mode. 67 Subtotal void is full (in the key ...
Service Manual
Page 3
...Appears in the afternoon (PM). Number of a transaction when the electronic journal (EJ) memory is nearly full. The manager can be ... morning (AM), and "P" in the far-right six positions (hour-minute - XE-A202U SPECIFICATIONS - 2 - Operator display PLU/SUB DEPT REPEAT Customer display (Pop-up...sMachine state symbols : Appears during programming. : Appears when an error is detected. : Appears when the subtotal is displayed or when...amount. PGM: To program various items. VOID: Enters into the void mode. When you have registered ten times, the display will show "0." (2 3 3 ..... 9 3 0 3 1 ...
...Appears in the afternoon (PM). Number of a transaction when the electronic journal (EJ) memory is nearly full. The manager can be ... morning (AM), and "P" in the far-right six positions (hour-minute - XE-A202U SPECIFICATIONS - 2 - Operator display PLU/SUB DEPT REPEAT Customer display (Pop-up...sMachine state symbols : Appears during programming. : Appears when an error is detected. : Appears when the subtotal is displayed or when...amount. PGM: To program various items. VOID: Enters into the void mode. When you have registered ten times, the display will show "0." (2 3 3 ..... 9 3 0 3 1 ...
Service Manual
Page 4
...stamp • No 4) Printing area Number of thermal head heater elements 288 dots (4.75) 48 (288 dots) print area (max.24 characters) (4.75) 0.167 XE-A202U SPECIFICATIONS - 3 - 57.5±0.5 (Paper dimension) (units : mm) of key entry (by PGM selection) 6. of dot : 288 dots • ...the timing of station : 1 (Receipt or journal) • Validation : No. • Printing system : Line thermal • No. Segment Amount Minus sign Error PGM Mode CASH, CHECK, CHARGE SUB TOTAL/ short tender Change Currency Conversion Department PLU Repeat Receipt OFF DC SHIFT NUMBER Clerk No.
...stamp • No 4) Printing area Number of thermal head heater elements 288 dots (4.75) 48 (288 dots) print area (max.24 characters) (4.75) 0.167 XE-A202U SPECIFICATIONS - 3 - 57.5±0.5 (Paper dimension) (units : mm) of key entry (by PGM selection) 6. of dot : 288 dots • ...the timing of station : 1 (Receipt or journal) • Validation : No. • Printing system : Line thermal • No. Segment Amount Minus sign Error PGM Mode CASH, CHECK, CHARGE SUB TOTAL/ short tender Change Currency Conversion Department PLU Repeat Receipt OFF DC SHIFT NUMBER Clerk No.
Service Manual
Page 14
... can exit the test mode by pressing any key. B) The sensor correctly indicates the status of the drawer 1. *On the XE-A202, "C" (CLOSED) is always displayed. 4 End of paper Y:1 - If an error does not occur, the following : X:1 - This data to be checked: 10000H , 10001H , 10002H , 10004H , 10008H...up sensor. 7-segment display: 1 0 6 XY 3 Check the following addresses are lost after this test. XE-A202U TEST FUNCTION - 13 - Display 1 0 6 XXXXXX - Head DOWN O - If an error occurs at the position (excluding feed key) where there is an input data contact is pressed, the date ...
... can exit the test mode by pressing any key. B) The sensor correctly indicates the status of the drawer 1. *On the XE-A202, "C" (CLOSED) is always displayed. 4 End of paper Y:1 - If an error does not occur, the following : X:1 - This data to be checked: 10000H , 10001H , 10002H , 10004H , 10008H...up sensor. 7-segment display: 1 0 6 XY 3 Check the following addresses are lost after this test. XE-A202U TEST FUNCTION - 13 - Display 1 0 6 XXXXXX - Head DOWN O - If an error occurs at the position (excluding feed key) where there is an input data contact is pressed, the date ...
Service Manual
Page 15
...print. 4 End of testing Completion print RS TEST OK Error print RS TEST **NG**ERxx xx Contents of the error 01 ER DR error 02 ER CI error 03 RS CD error 04 RS CD error 05 SD RD error DATA data 06 SD RD error DATA error/framing error 14) Sleep mode test 1 Key operation 550 RCPT/...PO 2 Test procedure The test program checks the system in the following . 550 XE-A202U TEST ...
...print. 4 End of testing Completion print RS TEST OK Error print RS TEST **NG**ERxx xx Contents of the error 01 ER DR error 02 ER CI error 03 RS CD error 04 RS CD error 05 SD RD error DATA data 06 SD RD error DATA error/framing error 14) Sleep mode test 1 Key operation 550 RCPT/...PO 2 Test procedure The test program checks the system in the following . 550 XE-A202U TEST ...