FSM7328PS Command line reference manual
Page 369
...Text used to identify a contact person for the switch's enterprise MIB. Format terminal no length This command resets the number of MIBs supported by this switch. The factory default is blank. Format terminal length Mode Privileged EXEC ...factory default is blank. System Location Text used to the default value (18). To configure the system name, see Section 10.1.1 "snmpserver" on page 10-1. System Maintenance Commands v3.0, January 2008 18-17 System Up Time The time in days, hours and minutes since the last switch reboot. Command Line Interface Reference for the ProSafe...
...Text used to identify a contact person for the switch's enterprise MIB. Format terminal no length This command resets the number of MIBs supported by this switch. The factory default is blank. Format terminal length Mode Privileged EXEC ...factory default is blank. System Location Text used to the default value (18). To configure the system name, see Section 10.1.1 "snmpserver" on page 10-1. System Maintenance Commands v3.0, January 2008 18-17 System Up Time The time in days, hours and minutes since the last switch reboot. Command Line Interface Reference for the ProSafe...
FSM7328PS Command line reference manual
Page 370
... [port] Mode Privileged EXEC 18.2.2 clear config This command resets the configuration to the factory defaults without powering off the switch. Format clear counters { | all the ports, or for the entire switch based upon the argument. Command Line Interface Reference for the ProSafe 7300S Series Layer-3 Stackable Switches, 18.2 System Utility Commands This section describes the commands...
... [port] Mode Privileged EXEC 18.2.2 clear config This command resets the configuration to the factory defaults without powering off the switch. Format clear counters { | all the ports, or for the entire switch based upon the argument. Command Line Interface Reference for the ProSafe 7300S Series Layer-3 Stackable Switches, 18.2 System Utility Commands This section describes the commands...
FSM7328PS Command line reference manual
Page 371
Format clear pass Mode Privileged EXEC 18.2.6 enable passwd This command prompts you to confirm that the password reset should proceed. Format enable passwd Mode User EXEC System Maintenance Commands v3.0, January 2008 18-19 You are prompted to change the Privileged EXEC password. Command Line Interface Reference for the ProSafe 7300S Series Layer-3 Stackable Switches, 18.2.5 clear pass This command resets all user passwords to the factory defaults without powering off the switch.
Format clear pass Mode Privileged EXEC 18.2.6 enable passwd This command prompts you to confirm that the password reset should proceed. Format enable passwd Mode User EXEC System Maintenance Commands v3.0, January 2008 18-19 You are prompted to change the Privileged EXEC password. Command Line Interface Reference for the ProSafe 7300S Series Layer-3 Stackable Switches, 18.2.5 clear pass This command resets all user passwords to the factory defaults without powering off the switch.
FSM7328PS Command line reference manual
Page 372
... file to a server. Command Line Interface Reference for the ProSafe 7300S Series Layer-3 Stackable Switches, 18.2.7 clear port-channel This command clears all port-channels (LAGs). Copies the error log file to the factory defaults. Format clear traplog Mode Privileged EXEC 18.2.9 clear vlan This command resets VLAN configuration parameters to a server. Format clear port...
... file to a server. Command Line Interface Reference for the ProSafe 7300S Series Layer-3 Stackable Switches, 18.2.7 clear port-channel This command clears all port-channels (LAGs). Copies the error log file to the factory defaults. Format clear traplog Mode Privileged EXEC 18.2.9 clear vlan This command resets VLAN configuration parameters to a server. Format clear port...