FTOS Command Line Reference Guide for the S55 System FTOS 8.3.5.3
Page 102
...Unit Example Figure 4-20. Command Example: show environment thermal-sensor Force10#show inventory media. Vendor field removed from output of show environment thermal-sensor -- Unit Bay Status Type 0 0 up AC 0 1 absent Example Figure 4-19. Syntax show environment pem... Version 7.5.1.0 Version 6.2.1.0 Version 5.3.1.0 Introduced on E-Series 102 | Control and Monitoring www.dell.com | support.dell.com Example Figure 4-18. Command Example: show environment pem Force10#show inventory [media slot] Parameters media slot (OPTIONAL) Enter the keyword media followed by...
...Unit Example Figure 4-20. Command Example: show environment thermal-sensor Force10#show inventory media. Vendor field removed from output of show environment thermal-sensor -- Unit Bay Status Type 0 0 up AC 0 1 absent Example Figure 4-19. Syntax show environment pem... Version 7.5.1.0 Version 6.2.1.0 Version 5.3.1.0 Introduced on E-Series 102 | Control and Monitoring www.dell.com | support.dell.com Example Figure 4-18. Command Example: show environment pem Force10#show inventory [media slot] Parameters media slot (OPTIONAL) Enter the keyword media followed by...
FTOS Command Line Reference Guide for the S55 System FTOS 8.3.5.3
Page 103
... the frequency capability, which is stored in Figure 4-23. Use the show interfaces command to the SFMs, for C300 (C-Series) Force10# show inventory Chassis Type : C300 Chassis Mode : 1.0 Software Version : FTOS-EF-7.6.1.0 Slot Item Serial Number Part Number Revision... C300 TY000001400 7520029999 04 3 LC-CB-GE-48T FX000020075 7520036700 01 0 LC-CB-RPM 0060361 7520029300 02 0 CC-C-1200W-AC N/A N/A N/A 1 CC-C-1200W-AC N/A N/A N/A 0 CC-C300-FAN * - Example output of show inventory for example: ... 0 CC-E-SFM ** 0004875 1 CC-E-SFM **...
... the frequency capability, which is stored in Figure 4-23. Use the show interfaces command to the SFMs, for C300 (C-Series) Force10# show inventory Chassis Type : C300 Chassis Mode : 1.0 Software Version : FTOS-EF-7.6.1.0 Slot Item Serial Number Part Number Revision... C300 TY000001400 7520029999 04 3 LC-CB-GE-48T FX000020075 7520036700 01 0 LC-CB-RPM 0060361 7520029300 02 0 CC-C-1200W-AC N/A N/A N/A 1 CC-C-1200W-AC N/A N/A N/A 0 CC-C300-FAN * - Example output of show inventory for example: ... 0 CC-E-SFM ** 0004875 1 CC-E-SFM **...
FTOS Command Line Reference Guide for the S55 System FTOS 8.3.5.3
Page 105
... Type System Mode Software Version : S4810 : 1.0 : E8-3-12-2 Unit Type Serial Number Part Number Rev Piece Part ID * 2 S4810-01-64F HADL123J20113 7590009602 A N/A 2 S4810-PWR-AC H6DL123J20113 7590008502 A N/A 2 S4810-FAN N/A N/A N/A N/A 2 S4810-FAN N/A N/A N/A N/A Rev Svc Tag Exprs Svc Code N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A * - Management Unit Software Protocol Configured FTOS# Control and Monitoring | 105 show inventory for...
... Type System Mode Software Version : S4810 : 1.0 : E8-3-12-2 Unit Type Serial Number Part Number Rev Piece Part ID * 2 S4810-01-64F HADL123J20113 7590009602 A N/A 2 S4810-PWR-AC H6DL123J20113 7590008502 A N/A 2 S4810-FAN N/A N/A N/A N/A 2 S4810-FAN N/A N/A N/A N/A Rev Svc Tag Exprs Svc Code N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A * - Management Unit Software Protocol Configured FTOS# Control and Monitoring | 105 show inventory for...
FTOS Command Line Reference Guide for the S55 System FTOS 8.3.5.3
Page 107
... Up Time : 18 hr, 42 min FTOS Version : 8-4-1-317 Jumbo Capable : yes Boot Flash : A: 2.9.1.1c B: 2.9.2.0E0 [booted] Memory Size : 1073741824 bytes Temperature : 65C Power Status : AC Voltage : ok Serial Number : FX000049121 Part Number : 7520042807 Rev 03 Vendor Id : 04 Date Code : 01212010 Country Code : 01 Piece Part ID : N/A PPID Revision : N/A Service...
... Up Time : 18 hr, 42 min FTOS Version : 8-4-1-317 Jumbo Capable : yes Boot Flash : A: 2.9.1.1c B: 2.9.2.0E0 [booted] Memory Size : 1073741824 bytes Temperature : 65C Power Status : AC Voltage : ok Serial Number : FX000049121 Part Number : 7520042807 Rev 03 Vendor Id : 04 Date Code : 01212010 Country Code : 01 Piece Part ID : N/A PPID Revision : N/A Service...
FTOS Command Line Reference Guide for the S55 System FTOS 8.3.5.3
Page 108
... card with SFP optics (EF) Current Type : E48PF - 48-port GE line card with SFP optics (EF) Hardware Rev : Base - 1.0 PP0 - www.dell.com | support.dell.com Table 4-1 list the definitions of the line card. Displays an internal code, which version was used in the line card. n/a Num Ports : 48... card is within range. Displays the line card type installed in show linecard 11 brief -- List the memory of ports in the chassis: • AC = AC power supply • DC = DC Power Entry Module (PEM) Displays OK if the line voltage is to reconfigure the line card type if they...
... card with SFP optics (EF) Current Type : E48PF - 48-port GE line card with SFP optics (EF) Hardware Rev : Base - 1.0 PP0 - www.dell.com | support.dell.com Table 4-1 list the definitions of the line card. Displays an internal code, which version was used in the line card. n/a Num Ports : 48... card is within range. Displays the line card type installed in show linecard 11 brief -- List the memory of ports in the chassis: • AC = AC power supply • DC = DC Power Entry Module (PEM) Displays OK if the line voltage is to reconfigure the line card type if they...
FTOS Command Line Reference Guide for the S55 System FTOS 8.3.5.3
Page 129
... Mem Size : 1073741824 bytes RP2 Mem Size : 1073741824 bytes MMC Mem Size : 3566329856 bytes External MMC : 128180224 bytes USB Mem Size : n/a Temperature : 36C Power Status : AC Voltage : ok Serial Number : FX000056234 Part Number : 7520043401 Rev 05 Vendor Id : 04 Date Code : 01072010 Country Code : 01 Piece Part ID : N/A PPID Revision : N/A Service...
... Mem Size : 1073741824 bytes RP2 Mem Size : 1073741824 bytes MMC Mem Size : 3566329856 bytes External MMC : 128180224 bytes USB Mem Size : n/a Temperature : 36C Power Status : AC Voltage : ok Serial Number : FX000056234 Part Number : 7520043401 Rev 05 Vendor Id : 04 Date Code : 01072010 Country Code : 01 Piece Part ID : N/A PPID Revision : N/A Service...
FTOS Command Line Reference Guide for the S55 System FTOS 8.3.5.3
Page 134
Stack Info -- Fan Status -- www.dell.com | support.dell.com Example Figure 4-55. Unit UnitType Status ReqTyp CurTyp Version Ports 0 Member not present 1 Standby online S50V S50V 7.7.1.0 52 2 Mgmt online S50V S50V 7.7.1.0 52 3 ...S50-01-10GE-2P 2 1 1 online S50-01-24G-2S 1 2 0 online S50-01-10GE-2P 2 2 1 online S50-01-24G-2S 1 -- Unit Bay Status Type 1 0 up AC 1 1 absent 2 0 up Force10# 134 | Control and Monitoring Unit TrayStatus Fan0 Fan1 Fan2 Fan3 Fan4 Fan5 1 up up up up up up up 2 up up up up up...
Stack Info -- Fan Status -- www.dell.com | support.dell.com Example Figure 4-55. Unit UnitType Status ReqTyp CurTyp Version Ports 0 Member not present 1 Standby online S50V S50V 7.7.1.0 52 2 Mgmt online S50V S50V 7.7.1.0 52 3 ...S50-01-10GE-2P 2 1 1 online S50-01-24G-2S 1 2 0 online S50-01-10GE-2P 2 2 1 online S50-01-24G-2S 1 -- Unit Bay Status Type 1 0 up AC 1 1 absent 2 0 up Force10# 134 | Control and Monitoring Unit TrayStatus Fan0 Fan1 Fan2 Fan3 Fan4 Fan5 1 up up up up up up up 2 up up up up up...
FTOS Command Line Reference Guide for the S55 System FTOS 8.3.5.3
Page 135
Command Example: show system stack-unit FTOS#show system stack-unit 0 -- Fan Status -- Power Supplies -- Unit Bay Status Type FanStatus 0 0 up AC up 11280 FTOS# Control and Monitoring | 135 Unit 0 -- Example Figure 4-56. Unit Type : Management Unit Status : online Next Boot : online Required Type : S4810 - 52-port ...
Command Example: show system stack-unit FTOS#show system stack-unit 0 -- Fan Status -- Power Supplies -- Unit Bay Status Type FanStatus 0 0 up AC up 11280 FTOS# Control and Monitoring | 135 Unit 0 -- Example Figure 4-56. Unit Type : Management Unit Status : online Next Boot : online Required Type : S4810 - 52-port ...
FTOS Command Line Reference Guide for the S55 System FTOS 8.3.5.3
Page 136
... show system stack-unit 0 -- Fan Status -- Status : not present -- Unit Bay Status Type 0 0 up AC 0 1 up 7200 21 Speed in the S-Series stack. www.dell.com | support.dell.com Example Figure 4-57. Unit 0 -- Unit Bay TrayStatus Fan0 Speed Fan1 Speed Fan2 Speed Temp 0 0 up ...up 7200 up 7200 up 7200 20 0 1 up up 7200 up 7200 up AC -- Command Example: show system stack-unit (S55) Force10#show hardware...
... show system stack-unit 0 -- Fan Status -- Status : not present -- Unit Bay Status Type 0 0 up AC 0 1 up 7200 21 Speed in the S-Series stack. www.dell.com | support.dell.com Example Figure 4-57. Unit 0 -- Unit Bay TrayStatus Fan0 Speed Fan1 Speed Fan2 Speed Temp 0 0 up ...up 7200 up 7200 up 7200 20 0 1 up up 7200 up 7200 up AC -- Command Example: show system stack-unit (S55) Force10#show hardware...
Installing the S55 System
Page 3
... ports (optional 21 Connect two S55s 22 Connect three or more S55s 23 Supply power and power up the system 24 Power up sequence 24 AC power 24 DC power 25 Hot-swap units in a stack 25 5 Power Supplies Components 27 Contents | 3
... ports (optional 21 Connect two S55s 22 Connect three or more S55s 23 Supply power and power up the system 24 Power up sequence 24 AC power 24 DC power 25 Hot-swap units in a stack 25 5 Power Supplies Components 27 Contents | 3
Installing the S55 System
Page 4
www.dell.com | support.dell.com Install an AC or DC power supply 27 Replace an AC or DC power supply 29 6 Fans Components 31 Install a fan module 31 Replace a fan module 32 7 Access the console ports Access the RJ45 console port (... Access the RJ-45 console port with a DB-9 adapter 34 Access the USB-B console port 34 8 S55 Specifications Chassis Physical Design 37 Environmental Parameters 37 AC Power Requirements 37 DC Power Requirements 38 IEEE Standards 38 Agency Compliance 38 NEBS (Network Equipment Building Systems) Compliance 38 Safety Standards and Compliance Agency...
www.dell.com | support.dell.com Install an AC or DC power supply 27 Replace an AC or DC power supply 29 6 Fans Components 31 Install a fan module 31 Replace a fan module 32 7 Access the console ports Access the RJ45 console port (... Access the RJ-45 console port with a DB-9 adapter 34 Access the USB-B console port 34 8 S55 Specifications Chassis Physical Design 37 Environmental Parameters 37 AC Power Requirements 37 DC Power Requirements 38 IEEE Standards 38 Agency Compliance 38 NEBS (Network Equipment Building Systems) Compliance 38 Safety Standards and Compliance Agency...
Installing the S55 System
Page 8
...supply and 2 fan units with airflow from I/O panel to utility panel 44 port 10/100/1000 Base-T with 4 SFP ports and 2 expansion module slots, 1 AC power S55T-AC-R supply and 2 fan units with airflow from utility panel to I/O panel 44 port 10/100/1000 Base-T with 4 SFP ports and 2 expansion module slots,... (not supplied) • Ground cable (not supplied) • Ground cable screws (included) • Copper/fiber cables Other optional components are ordered separately. www.dell.com | support.dell.com Orderable S55 systems The S55 can be ordered in several different configurations.
...supply and 2 fan units with airflow from I/O panel to utility panel 44 port 10/100/1000 Base-T with 4 SFP ports and 2 expansion module slots, 1 AC power S55T-AC-R supply and 2 fan units with airflow from utility panel to I/O panel 44 port 10/100/1000 Base-T with 4 SFP ports and 2 expansion module slots,... (not supplied) • Ground cable (not supplied) • Ground cable screws (included) • Copper/fiber cables Other optional components are ordered separately. www.dell.com | support.dell.com Orderable S55 systems The S55 can be ordered in several different configurations.
Installing the S55 System
Page 14
...AC and DC are installed near each other, position the two chassis at least 5 inches (12.7 cm) apart to the same ground point used by the power service in an equipment rack (or cabinet) with 2 air flow options. The redundant power supplies must be grounded to permit proper airflow. www.dell....com | support.dell.com Cabinet placement The S55 should not be installed in a Common Bond Network. Rack mounting When you prepare your area. Be...
...AC and DC are installed near each other, position the two chassis at least 5 inches (12.7 cm) apart to the same ground point used by the power service in an equipment rack (or cabinet) with 2 air flow options. The redundant power supplies must be grounded to permit proper airflow. www.dell....com | support.dell.com Cabinet placement The S55 should not be installed in a Common Bond Network. Rack mounting When you prepare your area. Be...
Installing the S55 System
Page 15
...: Electrostatic discharge (ESD) damage can occur when components are serviced. Storing components If you do not install your system and components immediately, Dell Force10 recommends that the socket-outlet is located/installed near the equipment and is connected between the system and the power source. After you are ready... to 70° C). • Store on the AC and the DC system; Always wear an ESD-preventive wrist or heel ground strap when handling the S55 and its components on an antistatic ...
...: Electrostatic discharge (ESD) damage can occur when components are serviced. Storing components If you do not install your system and components immediately, Dell Force10 recommends that the socket-outlet is located/installed near the equipment and is connected between the system and the power source. After you are ready... to 70° C). • Store on the AC and the DC system; Always wear an ESD-preventive wrist or heel ground strap when handling the S55 and its components on an antistatic ...
Installing the S55 System
Page 24
...separately. WARNING: Electrostatic discharge (ESD) damage can occur if components are not installed. The Stack ID LED displays a digit to each AC receptacle, making sure that sufficient over-current protection devices are used. • all protective covers are in the shipping container for the ...Always wear an ESD-preventive wrist or heel ground strap when handling the S55 and its components. For a single chassis, a 0 displays. Dell Force10 recommends re-inspecting your system prior to the S55 after they are mounted in a stacking chain. When the boot up sequence is steadily ...
...separately. WARNING: Electrostatic discharge (ESD) damage can occur if components are not installed. The Stack ID LED displays a digit to each AC receptacle, making sure that sufficient over-current protection devices are used. • all protective covers are in the shipping container for the ...Always wear an ESD-preventive wrist or heel ground strap when handling the S55 and its components. For a single chassis, a 0 displays. Dell Force10 recommends re-inspecting your system prior to the S55 after they are mounted in a stacking chain. When the boot up sequence is steadily ...
Installing the S55 System
Page 25
AC power connection DC power Connect the plug to an existing stack, the CLI will display an error, and the unit will not be powered down. ...
AC power connection DC power Connect the plug to an existing stack, the CLI will display an error, and the unit will not be powered down. ...
Installing the S55 System
Page 27
... supply unit, use the following power supply options are field replaceable. 5 Power Supplies The S55 is designed to that power supply. The S55T-AC/S55TAC-R system comes from the modules prior to ensure that provide the cooling for the chassis. The power supply units are required for the...grounded properly. WARNING: To prevent electrical shock, make sure the S55 is orderable as an empty chassis (S55T) or with integrated reverse flow fan (Catalog# S55-PWR-DC-R) Install an AC or DC power supply The power supply units in a single piece with a single power supply. Components ...
... supply unit, use the following power supply options are field replaceable. 5 Power Supplies The S55 is designed to that power supply. The S55T-AC/S55TAC-R system comes from the modules prior to ensure that provide the cooling for the chassis. The power supply units are required for the...grounded properly. WARNING: To prevent electrical shock, make sure the S55 is orderable as an empty chassis (S55T) or with integrated reverse flow fan (Catalog# S55-PWR-DC-R) Install an AC or DC power supply The power supply units in a single piece with a single power supply. Components ...
Installing the S55 System
Page 28
...device (SPD) to protect the AC power supplies from damage to -48V. CAUTION: The DC power supply comes with a 6-8inch cord with a snap-in plug that attaches to the DC power supply and screw terminals that the power supply is marked + 48V - . Dell Force10 recommends using a longer cable,... to the main power. AC Power Supply Cable Connector PSU1 Fan Module Grab Handle PSU0 Optional Module Cable Connector PSU1 Grab Handle To install a ...
...device (SPD) to protect the AC power supplies from damage to -48V. CAUTION: The DC power supply comes with a 6-8inch cord with a snap-in plug that attaches to the DC power supply and screw terminals that the power supply is marked + 48V - . Dell Force10 recommends using a longer cable,... to the main power. AC Power Supply Cable Connector PSU1 Fan Module Grab Handle PSU0 Optional Module Cable Connector PSU1 Grab Handle To install a ...
Installing the S55 System
Page 29
... to the new module. 6 The system powers up as soon as the cables are connected between the power supply and the power source. Replace an AC or DC power supply NOTE: If a power supply fails, it into the power supply bay. 4 Tighten the securing screws on the replacement unit, slide it...
... to the new module. 6 The system powers up as soon as the cables are connected between the power supply and the power source. Replace an AC or DC power supply NOTE: If a power supply fails, it into the power supply bay. 4 Tighten the securing screws on the replacement unit, slide it...
Installing the S55 System
Page 37
...°F (-40° to 70°C) No performance degradation to 10,000 feet (3,048 meters) 10 to 85% non-condensing MIL-STD-810 AC Power Requirements Parameter Nominal Input Voltage Maximum AC Power Supply Input Current Maximum System Power Input Specifications 100 to 240 VAC, 47-63 Hz 5 A 135 W 8 S55 Specifications | 37
...°F (-40° to 70°C) No performance degradation to 10,000 feet (3,048 meters) 10 to 85% non-condensing MIL-STD-810 AC Power Requirements Parameter Nominal Input Voltage Maximum AC Power Supply Input Current Maximum System Power Input Specifications 100 to 240 VAC, 47-63 Hz 5 A 135 W 8 S55 Specifications | 37