Page 7
...), and line cards. Avoid exposure to ensure adequate system cooling and for RPM, SFM3, and line card slots. WARNING: The installation of this equipment. E1200i systems run Dell Force10 OS (FTOS™) software. Information Symbols Symbol Warning Note Description This symbol informs you that could result in empty slots to laser radiation and...
...), and line cards. Avoid exposure to ensure adequate system cooling and for RPM, SFM3, and line card slots. WARNING: The installation of this equipment. E1200i systems run Dell Force10 OS (FTOS™) software. Information Symbols Symbol Warning Note Description This symbol informs you that could result in empty slots to laser radiation and...
E1200i ExaScale Installation Guide
Page 9
... (Diffserv or 802.1p). The E1200 System | 9 The RPM is a carrier-class, high-capacity aggregation router. 2 The E1200 System The Dell Force10 E1200 system is the core for line cards with Layer 2 switching and Layer 3 and routing capabilities. The FPC accepts packets, feeds packets to ... Module (RPM), at least eight Switch Fabric Modules (SFM3s) for the E1200i terminates on each other, increasing reliability. Each line card has at least one line card, and at least one Force10 Networks proprietary ASIC. all traffic destined for packet processing. Routing table entries ...
... (Diffserv or 802.1p). The E1200 System | 9 The RPM is a carrier-class, high-capacity aggregation router. 2 The E1200 System The Dell Force10 E1200 system is the core for line cards with Layer 2 switching and Layer 3 and routing capabilities. The FPC accepts packets, feeds packets to ... Module (RPM), at least eight Switch Fabric Modules (SFM3s) for the E1200i terminates on each other, increasing reliability. Each line card has at least one line card, and at least one Force10 Networks proprietary ASIC. all traffic destined for packet processing. Routing table entries ...
E1200i ExaScale Installation Guide
Page 30
...ügt über mehr als einen Stromanschluß; The following are Dell Force10 supplied plug types. All power plugs must also conform to the nearest appropriate facility grounding post. Use ANSI UNC 1/4-20 x 1/2 bolt. Figure 7-2. Cable Connector Required for E1200i AC High-strand-count conductor 0.267 diameter 2 Holes FN00011A All measurements in...
...ügt über mehr als einen Stromanschluß; The following are Dell Force10 supplied plug types. All power plugs must also conform to the nearest appropriate facility grounding post. Use ANSI UNC 1/4-20 x 1/2 bolt. Figure 7-2. Cable Connector Required for E1200i AC High-strand-count conductor 0.267 diameter 2 Holes FN00011A All measurements in...
FTOS Command Line Reference Guide FTOS 8.4.2.8 E-Series TeraScale
Page 83
... Version 8.1.1.2 Version 8.1.1.0 Version 6.2.1.1 Version 6.1.1.0 Added 2.4 micro-seconds option. Introduced on E-Series ExaScale E600i Introduced on E-Series ExaScale E1200i Support for E300 introduced (10.4 only) Values changed as described above Usage You save the configuration and reload the chassis for the ...epoch to 3.2 micro-seconds and lower the latency. When using 9 SFMs in an ExaScale chassis reduces throughput at any epoch setting. Dell Force10 recommends using 10 SFMs in an ExaScale chassis, the 10.4 and 2.4 settings are both line rate. Additionally, the 2.4 setting has...
... Version 8.1.1.2 Version 8.1.1.0 Version 6.2.1.1 Version 6.1.1.0 Added 2.4 micro-seconds option. Introduced on E-Series ExaScale E600i Introduced on E-Series ExaScale E1200i Support for E300 introduced (10.4 only) Values changed as described above Usage You save the configuration and reload the chassis for the ...epoch to 3.2 micro-seconds and lower the latency. When using 9 SFMs in an ExaScale chassis reduces throughput at any epoch setting. Dell Force10 recommends using 10 SFMs in an ExaScale chassis, the 10.4 and 2.4 settings are both line rate. Additionally, the 2.4 setting has...
FTOS Configuration Guide FTOS 8.4.2.8 E-Series TeraScale
Page 454
The E300 only supports one portpipe. References to the E1200 in this section include the E1200i-AC and E1200i-DC. For the purposes of diagnostics, the major difference between the E-Series platforms is a Dell Force10 specific term for a given set . Each portpipe has nine 3.125Gbps channels to the backplane, one... Type Port-pipes Channels / Capacity of physical interfaces or a port-set of Each Raw Slot Capacity / Slot Port-pipe Channel (Gbps) (Gbps) E1200/E1200i-AC/DC 2 E600/E600i 2 E300 1 9 3.125 9 3.125 8 3.125 56.25 56.25 25 454 | Interfaces One or two port pipes...
The E300 only supports one portpipe. References to the E1200 in this section include the E1200i-AC and E1200i-DC. For the purposes of diagnostics, the major difference between the E-Series platforms is a Dell Force10 specific term for a given set . Each portpipe has nine 3.125Gbps channels to the backplane, one... Type Port-pipes Channels / Capacity of physical interfaces or a port-set of Each Raw Slot Capacity / Slot Port-pipe Channel (Gbps) (Gbps) E1200/E1200i-AC/DC 2 E600/E600i 2 E300 1 9 3.125 9 3.125 8 3.125 56.25 56.25 25 454 | Interfaces One or two port pipes...
FTOS Version 8.4.1.5 Configuration Guide for ExaScale
Page 446
... this section include the E1200i-AC and E1200i-DC. References to each SFM. • E300-Each slot has one port pipe on the line card • 48 port high density cards have only one portpipe. For the purposes of diagnostics, the major difference between the E-Series platforms is a Dell Force10 specific term for the... one port pipe per slot. • E1200 and E600-Each slot has two port-pipes. Example: If the members have different Link MTU values. www.dell.com | support.dell.com Link MTU and IP MTU considerations for a given set of physical interfaces or a port-set.
... this section include the E1200i-AC and E1200i-DC. References to each SFM. • E300-Each slot has one port pipe on the line card • 48 port high density cards have only one portpipe. For the purposes of diagnostics, the major difference between the E-Series platforms is a Dell Force10 specific term for the... one port pipe per slot. • E1200 and E600-Each slot has two port-pipes. Example: If the members have different Link MTU values. www.dell.com | support.dell.com Link MTU and IP MTU considerations for a given set of physical interfaces or a port-set.
FTOS Version 8.4.1.5 Configuration Guide for ExaScale
Page 447
... Differences Concerning Port-pipes Chassis Type Port-pipes Channels / Capacity of Each Raw Slot Capacity / Slot Port-pipe Channel (Gbps) (Gbps) E1200/E1200i-AC/DC 2 E600/E600i 2 E300 1 9 3.125 9 3.125 8 3.125 56.25 56.25 25 Auto-Negotiation on Ethernet Interfaces Setting...with the speed command. When the speed is capable of the S-Series, its speed can also be executed. Note: As a best practice, Dell Force10 recommends keeping auto-negotiation enabled. Auto-negotiation should only be manually set to 1000 or auto. Note: Starting with FTOS 7.8.1.0, when a copper...
... Differences Concerning Port-pipes Chassis Type Port-pipes Channels / Capacity of Each Raw Slot Capacity / Slot Port-pipe Channel (Gbps) (Gbps) E1200/E1200i-AC/DC 2 E600/E600i 2 E300 1 9 3.125 9 3.125 8 3.125 56.25 56.25 25 Auto-Negotiation on Ethernet Interfaces Setting...with the speed command. When the speed is capable of the S-Series, its speed can also be executed. Note: As a best practice, Dell Force10 recommends keeping auto-negotiation enabled. Auto-negotiation should only be manually set to 1000 or auto. Note: Starting with FTOS 7.8.1.0, when a copper...
Installing and Maintaining the E1200i System
Page 7
...empty slots to install fan trays, power supplies, route processor modules (RPMs), switch fabric modules (SFMs), and line cards. E1200i systems run Force10 OS (FTOS™) software. Information Symbols and Warnings Table 1-1 defines the information symbols used throughout this equipment. This symbol...installation could result in equipment damage or loss of this equipment shall be performed by -step procedures to rack mount the Dell Force10 E1200 chassis, as well as instructions to ensure adequate system cooling and for preliminary software configuration information. Read this guide before...
...empty slots to install fan trays, power supplies, route processor modules (RPMs), switch fabric modules (SFMs), and line cards. E1200i systems run Force10 OS (FTOS™) software. Information Symbols and Warnings Table 1-1 defines the information symbols used throughout this equipment. This symbol...installation could result in equipment damage or loss of this equipment shall be performed by -step procedures to rack mount the Dell Force10 E1200 chassis, as well as instructions to ensure adequate system cooling and for preliminary software configuration information. Read this guide before...
Installing and Maintaining the E1200i System
Page 9
...E1200i terminates on page 65. The E1200 System | 9 The RPM is a carrier-class, high-capacity aggregation router. Operating the E1200 system with the RPM contains the boot ROM and runtime images. the flexible packet classification (FPC) ASIC and the Buffer and Traffic Manager (BTM) ASIC. 2 The E1200 System The Dell Force10... routing and control operations; Each CPU has its own memory, which isolates processes from each CPU. Each line card has Dell Force10 proprietary ASICs - Each RPM accommodates an external flash memory card that can be used to input/output ports, handles packet ...
...E1200i terminates on page 65. The E1200 System | 9 The RPM is a carrier-class, high-capacity aggregation router. Operating the E1200 system with the RPM contains the boot ROM and runtime images. the flexible packet classification (FPC) ASIC and the Buffer and Traffic Manager (BTM) ASIC. 2 The E1200 System The Dell Force10... routing and control operations; Each CPU has its own memory, which isolates processes from each CPU. Each line card has Dell Force10 proprietary ASICs - Each RPM accommodates an external flash memory card that can be used to input/output ports, handles packet ...
Installing and Maintaining the E1200i System
Page 30
... is green or green with local codes. Check with your local electrical codes in inches. 0.750" 0.267 diameter 2 Holes FN00011A Installing Power Supplies CAUTION: An E1200i AC power supply still has power after extraction, and has completely powered off when the fans have an appropriately sized plug that complies with your... types. CAUTION: The power cord is easily accessible. Disconnect all power cords before reinserting the supply Power Cord Requirements If using a power cord other then a Dell Force10 supplied power cord, the cord must comply with yellow stripe).
... is green or green with local codes. Check with your local electrical codes in inches. 0.750" 0.267 diameter 2 Holes FN00011A Installing Power Supplies CAUTION: An E1200i AC power supply still has power after extraction, and has completely powered off when the fans have an appropriately sized plug that complies with your... types. CAUTION: The power cord is easily accessible. Disconnect all power cords before reinserting the supply Power Cord Requirements If using a power cord other then a Dell Force10 supplied power cord, the cord must comply with yellow stripe).