Page 4
iv Chapter 3 Intelligent Manageability Asset Management ...3-2 Compaq Diagnostics for Windows NT 3-3 Fault Management...3-4 SMART III Hard Drive Fault Prediction 3-5 ECC Fault Prediction and Prefailure Warranty 3-5 Proactive Backup...3-5 Surge-Tolerant Power Supply 3-5 Thermal Sensor ...3-6 Security Management...3-6 Disabling Diskette Boot or Diskette Write 3-7 Disabling a Serial Port or Parallel Port 3-8 Password Security ...3-9 QuickLock/QuickBlank 3-15 Cable Lock...
iv Chapter 3 Intelligent Manageability Asset Management ...3-2 Compaq Diagnostics for Windows NT 3-3 Fault Management...3-4 SMART III Hard Drive Fault Prediction 3-5 ECC Fault Prediction and Prefailure Warranty 3-5 Proactive Backup...3-5 Surge-Tolerant Power Supply 3-5 Thermal Sensor ...3-6 Security Management...3-6 Disabling Diskette Boot or Diskette Write 3-7 Disabling a Serial Port or Parallel Port 3-8 Password Security ...3-9 QuickLock/QuickBlank 3-15 Cable Lock...
Reference Guide
Page 15
... Utility Power Supply 325-Watt power supply with four open. Standard External Connectors/Jacks Serial (two available) Parallel USB-hardware ready (two available) Wide-Ultra SCSI Ethernet (RJ-45) Headphone and microphone jacks Stereo line in/line out Keyboard Mouse VGA (AGP) on the drive you want to check. 1-3 Standard Features Continued Feature Compaq Professional Workstation AP500...
... Utility Power Supply 325-Watt power supply with four open. Standard External Connectors/Jacks Serial (two available) Parallel USB-hardware ready (two available) Wide-Ultra SCSI Ethernet (RJ-45) Headphone and microphone jacks Stereo line in/line out Keyboard Mouse VGA (AGP) on the drive you want to check. 1-3 Standard Features Continued Feature Compaq Professional Workstation AP500...
Reference Guide
Page 41
... screen displays a Local Alert message. The Prefailure Warranty for long periods of time. Third-party products that result in data losses. Compaq Professional Workstation AP500 Reference Guide During the scan, the disk drive will determine the "health" of each data sector and move data from any system ...Codes (CRC) and Error Checking and Correcting (ECC) codes to flag potentially bad areas of the disk. Surge-Tolerant Power Supply An integrated surge-tolerant power supply provides greater reliability when the workstation is able not only to monitor and report on its own health, but to fix...
... screen displays a Local Alert message. The Prefailure Warranty for long periods of time. Third-party products that result in data losses. Compaq Professional Workstation AP500 Reference Guide During the scan, the disk drive will determine the "health" of each data sector and move data from any system ...Codes (CRC) and Error Checking and Correcting (ECC) codes to flag potentially bad areas of the disk. Surge-Tolerant Power Supply An integrated surge-tolerant power supply provides greater reliability when the workstation is able not only to monitor and report on its own health, but to fix...
Reference Guide
Page 61
... SW1 switch, AGP expansion slot, four DIMM sockets, two processor slots, and other connectors) 10 Accelerated Graphics Port (AGP) graphics controller (preinstalled on selected models) Compaq Professional Workstation AP500 Reference Guide 6-7 Internal Components Continued Ref. Component 6 Power supply 7 3.5-inch removable hard drive cage that supports either three 1.0-inch drives or two 1.6-inch drives.
... SW1 switch, AGP expansion slot, four DIMM sockets, two processor slots, and other connectors) 10 Accelerated Graphics Port (AGP) graphics controller (preinstalled on selected models) Compaq Professional Workstation AP500 Reference Guide 6-7 Internal Components Continued Ref. Component 6 Power supply 7 3.5-inch removable hard drive cage that supports either three 1.0-inch drives or two 1.6-inch drives.
Reference Guide
Page 96
Workstation does not beep during the power-on self-test (POST). Speaker cable is connected. Ensure that speaker cable is not properly attached Possible Solution Replace the RTC battery. Headphones plugged in ... RTC battery replacement. Refer to be blocked. Contact your Compaq authorized reseller or service provider for installation instructions, or contact your Compaq authorized reseller or service provider. Let it cool down. 2. Be sure internal cables are not blocking the air intake of the power supply. 3. Battery life is a steady amber color, reseat the expansion...
Workstation does not beep during the power-on self-test (POST). Speaker cable is connected. Ensure that speaker cable is not properly attached Possible Solution Replace the RTC battery. Headphones plugged in ... RTC battery replacement. Refer to be blocked. Contact your Compaq authorized reseller or service provider for installation instructions, or contact your Compaq authorized reseller or service provider. Let it cool down. 2. Be sure internal cables are not blocking the air intake of the power supply. 3. Battery life is a steady amber color, reseat the expansion...
Reference Guide
Page 127
... battery. If the workstation is on the system board. Plug the battery connector onto pins 1-4 on , turn it off, then unplug the power cord from the grounded AC electrical outlet. 2. The lithium battery may not be removed. The battery is soldered in place and may explode if... mistreated. Do not abuse or disassemble. Use only replacement batteries supplied by Compaq. Remove the side access panel and the expansion board assembly. 3. Attaching the replacement battery Remove and discard the protective covering on the...
... battery. If the workstation is on the system board. Plug the battery connector onto pins 1-4 on , turn it off, then unplug the power cord from the grounded AC electrical outlet. 2. The lithium battery may not be removed. The battery is soldered in place and may explode if... mistreated. Do not abuse or disassemble. Use only replacement batteries supplied by Compaq. Remove the side access panel and the expansion board assembly. 3. Attaching the replacement battery Remove and discard the protective covering on the...
Reference Guide
Page 129
... F Workstation Specifications Table F-1 Workstation Specifications Dimensions (with bezel and without feet) Height Depth Width Weight Power Supply Input Requirements Rated Input Voltage Rated Input Frequency Input Power (W) Input Power (BTU/hr) Power Supply Output Power Rated Steady-State Power Maximum Peak Power Relative Humidity Operating Nonoperating Temperature Operating Nonoperating U.S. 18.7 in 23.2 in 8.03 in 54.75 lb... 200 to 240 V 50 to 60 Hz 540 1830 325 325 5% - 95% 5% - 95% Metric 5°C to 35°C -40°C to 85°C Compaq Professional Workstation AP500 Reference Guide
... F Workstation Specifications Table F-1 Workstation Specifications Dimensions (with bezel and without feet) Height Depth Width Weight Power Supply Input Requirements Rated Input Voltage Rated Input Frequency Input Power (W) Input Power (BTU/hr) Power Supply Output Power Rated Steady-State Power Maximum Peak Power Relative Humidity Operating Nonoperating Temperature Operating Nonoperating U.S. 18.7 in 23.2 in 8.03 in 54.75 lb... 200 to 240 V 50 to 60 Hz 540 1830 325 325 5% - 95% 5% - 95% Metric 5°C to 35°C -40°C to 85°C Compaq Professional Workstation AP500 Reference Guide
Reference Guide
Page 133
... slot 1-2 identifying PCI/ISA 9-2 removing cover 9-4 external battery jumper 6-11 external connectors 1-8 F F10 key, accessing the Compaq Utilities menu 2-1 F12 key, initiating remote system installation 3-26 F1-F12 keys 1-11 FailSafe Boot Block ROM described 3-22 ...management described 3-4 ECC fault prediction 3-5 prefailure warranty for ECC memory 3-5 proactive backup 3-5 SMART III hard drive fault prediction 3-5 surge-tolerant power supply 3-5 thermal sensor 3-6 features Asset Management 1-4 audio 1-3 diagnostic tools 1-4 drive bays 1-3 drive controller 1-2 ECC 1-2 expansion slots 1-2 ...
... slot 1-2 identifying PCI/ISA 9-2 removing cover 9-4 external battery jumper 6-11 external connectors 1-8 F F10 key, accessing the Compaq Utilities menu 2-1 F12 key, initiating remote system installation 3-26 F1-F12 keys 1-11 FailSafe Boot Block ROM described 3-22 ...management described 3-4 ECC fault prediction 3-5 prefailure warranty for ECC memory 3-5 proactive backup 3-5 SMART III hard drive fault prediction 3-5 surge-tolerant power supply 3-5 thermal sensor 3-6 features Asset Management 1-4 audio 1-3 diagnostic tools 1-4 drive bays 1-3 drive controller 1-2 ECC 1-2 expansion slots 1-2 ...
Reference Guide
Page 136
...connectors POST D-1 sequence of tests 2-9 setting the POST mode 2-3 power connector 6-11 power cord 1-8 power cord set requirements C-1 power LED blink, enabling/disabling 2-4 power management 3-27 power supply 1-3 input and output F-1 surge tolerance 3-5 power switch 1-7 using for suspend mode 3-26 Compaq Professional Workstation AP500 Reference Guide messages error D-1 microphone jack 1-9 monitor troubleshooting 11-6 ... 4-1 Num Lock key 1-11 Num Lock state, setting 2-4 P parallel connector 1-9 disabling 2-4, 3-8 enabling 2-4 interface control 3-6 I-7 passwords See also Power-on Password;
...connectors POST D-1 sequence of tests 2-9 setting the POST mode 2-3 power connector 6-11 power cord 1-8 power cord set requirements C-1 power LED blink, enabling/disabling 2-4 power management 3-27 power supply 1-3 input and output F-1 surge tolerance 3-5 power switch 1-7 using for suspend mode 3-26 Compaq Professional Workstation AP500 Reference Guide messages error D-1 microphone jack 1-9 monitor troubleshooting 11-6 ... 4-1 Num Lock key 1-11 Num Lock state, setting 2-4 P parallel connector 1-9 disabling 2-4, 3-8 enabling 2-4 interface control 3-6 I-7 passwords See also Power-on Password;
Reference Guide
Page 139
..., solving 11-3 special function keys 1-11 specifications F-1 standard features 1-2 standard interfaces 1-3 Support Software CD Kit 3-29 support software, obtaining 3-29 surge-tolerant power supply 3-5 suspend mode 3-26 enabling/disabling power LED blink 2-4 SW1 switch 3-12, 6-12 symbols in text x on equipment xi symbols in text x system board components 6-11 system board revision, viewing...
..., solving 11-3 special function keys 1-11 specifications F-1 standard features 1-2 standard interfaces 1-3 Support Software CD Kit 3-29 support software, obtaining 3-29 surge-tolerant power supply 3-5 suspend mode 3-26 enabling/disabling power LED blink 2-4 SW1 switch 3-12, 6-12 symbols in text x on equipment xi symbols in text x system board components 6-11 system board revision, viewing...