Information Update
Page 1
Software RAID Solutions Software RAID PERC S100 and PERC S300 are not supported on the following Microsoft virtualization operating systems. Operating System Microsoft Hyper-V Server 2008 (x64) Microsoft Windows Server ...
Software RAID Solutions Software RAID PERC S100 and PERC S300 are not supported on the following Microsoft virtualization operating systems. Operating System Microsoft Hyper-V Server 2008 (x64) Microsoft Windows Server ...
Information Update
Page 3
信息更新 Error Logging Threshold Mode Memory Settings 软件 RAID 以下 Microsoft RAID PERC S100 和 PERC S300。 操作系统 Microsoft Hyper-V Server 2008 (x64) 启用了 Hyper-V 角色的 Microsoft Windows Server ...
信息更新 Error Logging Threshold Mode Memory Settings 软件 RAID 以下 Microsoft RAID PERC S100 和 PERC S300。 操作系统 Microsoft Hyper-V Server 2008 (x64) 启用了 Hyper-V 角色的 Microsoft Windows Server ...
Information Update
Page 9
Memory Settings Error Logging Threshold Mode RAID Software RAID PERC S100 と PERC S300 Microsoft 仮想化 OS OS Microsoft Hyper-V Server 2008 (x64) Microsoft Windows Server 2008 (x64)(Hyper-V Windows Server 2008 with SP2 (x64)(Hyper-V Windows Server 2008 R2(x64) (Hyper-V Enterprise、Web、Standard Enterprise、Web、Standard Enterprise、Web、Standard 2010 年 7 月
Memory Settings Error Logging Threshold Mode RAID Software RAID PERC S100 と PERC S300 Microsoft 仮想化 OS OS Microsoft Hyper-V Server 2008 (x64) Microsoft Windows Server 2008 (x64)(Hyper-V Windows Server 2008 with SP2 (x64)(Hyper-V Windows Server 2008 R2(x64) (Hyper-V Enterprise、Web、Standard Enterprise、Web、Standard Enterprise、Web、Standard 2010 年 7 月
Information Update
Page 11
Error Logging Threshold Mode Memory Settings RAID 솔루션 RAID PERC S100 및 PERC S300은 다음 Microsoft Microsoft Hyper-V Server 2008(x64) Microsoft Windows Server 2008(x64)(Hyper-V Windows Server 2008 SP2(x64)(Hyper-V Windows Server 2008 R2(x64)(Hyper-V 버전 Enterprise, Web 및 Standard Enterprise, Web 및 Standard Enterprise, Web 및 Standard 2010 년 7 월
Error Logging Threshold Mode Memory Settings RAID 솔루션 RAID PERC S100 및 PERC S300은 다음 Microsoft Microsoft Hyper-V Server 2008(x64) Microsoft Windows Server 2008(x64)(Hyper-V Windows Server 2008 SP2(x64)(Hyper-V Windows Server 2008 R2(x64)(Hyper-V 버전 Enterprise, Web 및 Standard Enterprise, Web 및 Standard Enterprise, Web 및 Standard 2010 년 7 월
Hardware Owner's Manual
Page 9
... 155 Troubleshooting an Internal USB Key 157 Troubleshooting an Optical Drive 158 Troubleshooting a Tape Backup Unit 159 Troubleshooting a Hard Drive 160 Troubleshooting a SAS or SAS RAID Controller . . . . 161 Troubleshooting Expansion Cards 162 Troubleshooting the Processor 163 5 Running the System Diagnostics 165 Using Online Diagnostics 165 Embedded System Diagnostics Features 165 When...
... 155 Troubleshooting an Internal USB Key 157 Troubleshooting an Optical Drive 158 Troubleshooting a Tape Backup Unit 159 Troubleshooting a Hard Drive 160 Troubleshooting a SAS or SAS RAID Controller . . . . 161 Troubleshooting Expansion Cards 162 Troubleshooting the Processor 163 5 Running the System Diagnostics 165 Using Online Diagnostics 165 Embedded System Diagnostics Features 165 When...
Hardware Owner's Manual
Page 18
Drives are not ready for insertion or removal NOTE: The drive status indicator remains off Drive predicted failure 18 About Your System Blinks green, amber, and off until all hard drives are initialized after system power is applied. Hard-Drive Indicator Patterns 1 2 1 hard-drive activity indicator (green) 2 hard-drive status indicator (green and amber) Drive-Status Indicator Pattern (RAID Only) Condition Blinks green two times per second Identify drive/preparing for removal Off Drive ready for insertion or removal during this time.
Drives are not ready for insertion or removal NOTE: The drive status indicator remains off Drive predicted failure 18 About Your System Blinks green, amber, and off until all hard drives are initialized after system power is applied. Hard-Drive Indicator Patterns 1 2 1 hard-drive activity indicator (green) 2 hard-drive status indicator (green and amber) Drive-Status Indicator Pattern (RAID Only) Condition Blinks green two times per second Identify drive/preparing for removal Off Drive ready for insertion or removal during this time.
Hardware Owner's Manual
Page 19
Back-Panel Features and Indicators Figure 1-3. Drive-Status Indicator Pattern (RAID Only) Condition Blinks amber four times per second Drive failed Blinks green slowly Drive rebuilding Steady green Drive online Blinks green three seconds, amber three Rebuild aborted seconds, and off six seconds. Back-Panel Features and Indicators 1 2 3 4 9 5 6 7 8 About Your System 19
Back-Panel Features and Indicators Figure 1-3. Drive-Status Indicator Pattern (RAID Only) Condition Blinks amber four times per second Drive failed Blinks green slowly Drive rebuilding Steady green Drive online Blinks green three seconds, amber three Rebuild aborted seconds, and off six seconds. Back-Panel Features and Indicators 1 2 3 4 9 5 6 7 8 About Your System 19
Hardware Owner's Manual
Page 27
... range. Check battery. Check battery. Remove and reseat the PCIe expansion cards. E1229 CPU # VCORE Regulator failure. Reseat the processor. See "RAID Battery (Optional)" on page 132 and "Troubleshooting System Cooling Problems" on page 163. If the problem persists, see "Getting Help" on of...Table 1-2. Memory has exceeded allowable temperature and has been disabled to prevent damage to the system for 10 seconds and restart the system. RAID battery is outside System Battery" on page 177. See "Troubleshooting the Processor" on page 154. If the problem persists, see "...
... range. Check battery. Check battery. Remove and reseat the PCIe expansion cards. E1229 CPU # VCORE Regulator failure. Reseat the processor. See "RAID Battery (Optional)" on page 132 and "Troubleshooting System Cooling Problems" on page 163. If the problem persists, see "Getting Help" on of...Table 1-2. Memory has exceeded allowable temperature and has been disabled to prevent damage to the system for 10 seconds and restart the system. RAID battery is outside System Battery" on page 177. See "Troubleshooting the Processor" on page 154. If the problem persists, see "...
Hardware Owner's Manual
Page 39
...< 24hr. Warns predictively that is running when the message appears or the operating system's documentation for the application that the Allow RAID battery to RAID battery has less than charge to notify you receive a system message not listed in the table, check the documentation for an ...off power to the system, reduce the hardware configuration or install higher-wattage power supplies, and then restart the system. See "Installing a RAID Battery" on the screen to greater than 24 hours of charge left. 24 hours of the message and recommended action. The system configuration...
...< 24hr. Warns predictively that is running when the message appears or the operating system's documentation for the application that the Allow RAID battery to RAID battery has less than charge to notify you receive a system message not listed in the table, check the documentation for an ...off power to the system, reduce the hardware configuration or install higher-wattage power supplies, and then restart the system. See "Installing a RAID Battery" on the screen to greater than 24 hours of charge left. 24 hours of the message and recommended action. The system configuration...
Hardware Owner's Manual
Page 91
... the hard-drive blank with your operating system for information about hot-swap drive removal. See "Removing the Front Bezel" on page 81. 2 From the RAID management software, prepare the drive for removal. Installing System Components 91
... the hard-drive blank with your operating system for information about hot-swap drive removal. See "Removing the Front Bezel" on page 81. 2 From the RAID management software, prepare the drive for removal. Installing System Components 91
Hardware Owner's Manual
Page 97
... connector on the card. Installing System Components 97 Damage due to the connector on the system board. NOTE: If connecting to a SAS RAID controller card (SAS or SATA hard drives), connect the data cable to servicing that is not authorized by your product documentation, or as... directed by a certified service technician. See the documentation that the hard drive's controller is not covered by Dell is enabled. You should only perform troubleshooting and simple repairs as authorized in your warranty. See Figure 3-11. 4 Snap the hard-drive ...
... connector on the card. Installing System Components 97 Damage due to the connector on the system board. NOTE: If connecting to a SAS RAID controller card (SAS or SATA hard drives), connect the data cable to servicing that is not authorized by your product documentation, or as... directed by a certified service technician. See the documentation that the hard drive's controller is not covered by Dell is enabled. You should only perform troubleshooting and simple repairs as authorized in your warranty. See Figure 3-11. 4 Snap the hard-drive ...
Hardware Owner's Manual
Page 132
...battery carrier out of the connector on the storage card. 13 Close the system. See Figure 3-25. 132 Installing System Components RAID Battery (Optional) Removing the RAID Battery The information in the System Setup program's Time and Date fields. 19 Exit the System Setup program. See "Removing ... a flat surface. 15 Reattach any peripherals and connect the system to an electrical outlet. 16 Turn on the two tabs holding the RAID battery and lift the RAID battery from the electrical outlet. 2 Open the system. See "Opening the System" on page 87. 4 Remove the storage controller card...
...battery carrier out of the connector on the storage card. 13 Close the system. See Figure 3-25. 132 Installing System Components RAID Battery (Optional) Removing the RAID Battery The information in the System Setup program's Time and Date fields. 19 Exit the System Setup program. See "Removing ... a flat surface. 15 Reattach any peripherals and connect the system to an electrical outlet. 16 Turn on the two tabs holding the RAID battery and lift the RAID battery from the electrical outlet. 2 Open the system. See "Opening the System" on page 87. 4 Remove the storage controller card...
Hardware Owner's Manual
Page 133
Figure 3-25. Removing and Installing the RAID Battery 1 2 6 3 5 4 1 battery cable connector 3 battery carrier 5 battery carrier release tab 2 battery carrier slots (2) 4 battery carrier tabs 6 RAID battery Installing a RAID Battery 1 Insert the RAID battery into place. See Figure 3-25. See Figure 3-25. 2 Align the tabs on the battery carrier with the battery carrier slots on the chassis. 3 Slide the battery carrier into the battery carrier slots until it locks into the battery carrier. Installing System Components 133
Figure 3-25. Removing and Installing the RAID Battery 1 2 6 3 5 4 1 battery cable connector 3 battery carrier 5 battery carrier release tab 2 battery carrier slots (2) 4 battery carrier tabs 6 RAID battery Installing a RAID Battery 1 Insert the RAID battery into place. See Figure 3-25. See Figure 3-25. 2 Align the tabs on the battery carrier with the battery carrier slots on the chassis. 3 Slide the battery carrier into the battery carrier slots until it locks into the battery carrier. Installing System Components 133
Hardware Owner's Manual
Page 160
...and follow the safety instructions that is not authorized by Dell is enabled and the drives appear in the System Setup...4 Restart the system, enter the System Setup program, and verify that the required device drivers for the RAID array. a Restart the system and enter the host adapter configuration utility program by a certified service technician. ... information about the configuration utility. You should only perform troubleshooting and simple repairs as authorized in a RAID array, perform the following steps. b Ensure that the hard drive(s) have been configured correctly for ...
...and follow the safety instructions that is not authorized by Dell is enabled and the drives appear in the System Setup...4 Restart the system, enter the System Setup program, and verify that the required device drivers for the RAID array. a Restart the system and enter the host adapter configuration utility program by a certified service technician. ... information about the configuration utility. You should only perform troubleshooting and simple repairs as authorized in a RAID array, perform the following steps. b Ensure that the hard drive(s) have been configured correctly for ...
Hardware Owner's Manual
Page 161
... Cooling Shroud" on page 88. 8 Ensure that is not authorized by Dell is enabled. See "Installing an Expansion Card" on page 115 9 If you have a battery-cached PERC controller, ensure that the RAID battery is properly connected and, if applicable, the memory module on page ...or PERC controller is not covered by your product documentation, or as directed by a certified service technician. Troubleshooting a SAS or SAS RAID Controller NOTE: When troubleshooting a SAS or PERC controller, also see the documentation for information about configuration settings. 4 Check the configuration ...
... Cooling Shroud" on page 88. 8 Ensure that is not authorized by Dell is enabled. See "Installing an Expansion Card" on page 115 9 If you have a battery-cached PERC controller, ensure that the RAID battery is properly connected and, if applicable, the memory module on page ...or PERC controller is not covered by your product documentation, or as directed by a certified service technician. Troubleshooting a SAS or SAS RAID Controller NOTE: When troubleshooting a SAS or PERC controller, also see the documentation for information about configuration settings. 4 Check the configuration ...
Hardware Owner's Manual
Page 183
...time, and system configuration information. You must format each logical drive with a USB connector. Master boot record. memory key - mirroring - See also striping and RAID. Network Attached Storage. NAS is installed or integrated in memory modules (DIMMs). A device that stores basic system data. NVRAM - An area in your system. ... device sends an NMI to a network. memory module - memory - parity - MHz - ms - Each partition can contain multiple logical drives. Megabits per second. In RAID arrays, a striped hard drive containing parity data.
...time, and system configuration information. You must format each logical drive with a USB connector. Master boot record. memory key - mirroring - See also striping and RAID. Network Attached Storage. NAS is installed or integrated in memory modules (DIMMs). A device that stores basic system data. NVRAM - An area in your system. ... device sends an NMI to a network. memory module - memory - parity - MHz - ms - Each partition can contain multiple logical drives. Megabits per second. In RAID arrays, a striped hard drive containing parity data.
Hardware Owner's Manual
Page 184
...essential to create an image. ROMB - peripheral - Power-on a video display. Preboot eXecution Environment. A way of RAID include RAID 0, RAID 1, RAID 5, RAID 10, and RAID 50. RAC - Redundant array of arithmetic and logic functions. RAM - Read-only memory. The primary computational chip inside... from editing or deleting. POST - Before the operating system loads when you turn on motherboard. Software written for processor. RAID - The system's primary temporary storage area for local-bus implementation. R-DIMM - A text file, usually shipped with multiple...
...essential to create an image. ROMB - peripheral - Power-on a video display. Preboot eXecution Environment. A way of RAID include RAID 0, RAID 1, RAID 5, RAID 10, and RAID 50. RAC - Redundant array of arithmetic and logic functions. RAM - Read-only memory. The primary computational chip inside... from editing or deleting. POST - Before the operating system loads when you turn on motherboard. Software written for processor. RAID - The system's primary temporary storage area for local-bus implementation. R-DIMM - A text file, usually shipped with multiple...
Hardware Owner's Manual
Page 185
... main circuit board, the system board usually contains most often used to connect a modem to identify it when you call Dell for video adapters with greater resolution and color display capabilities than standard ports. Data stored in memory that tells a system ...processors connected via a high-bandwidth link and managed by setting features such as the processor(s), RAM, controllers for operation. See also guarding, mirroring, and RAID. Small computer system interface. SVGA - See RAM. SCSI - A legacy I /O bus interface with a 9-pin connector that allows a network manager to...
... main circuit board, the system board usually contains most often used to connect a modem to identify it when you call Dell for video adapters with greater resolution and color display capabilities than standard ports. Data stored in memory that tells a system ...processors connected via a high-bandwidth link and managed by setting features such as the processor(s), RAM, controllers for operation. See also guarding, mirroring, and RAID. Small computer system interface. SVGA - See RAM. SCSI - A legacy I /O bus interface with a 9-pin connector that allows a network manager to...
Hardware Owner's Manual
Page 189
...B batteries troubleshooting, 152 battery troubleshooting the RAID card battery, 161 battery (system) replacing, 130 blank hard drive, 90 BMC configuring, 76 C CD drive troubleshooting, 158 connectors USB, 12, 19 video, 12, 19 contacting Dell, 177 control panel assembly features, 12 ...136 cooling fans troubleshooting, 154 cover closing, 86 D damaged systems troubleshooting, 152 Dell contacting, 177 Dell PowerEdge Diagnostics using, 165 diagnostics advanced testing options, 167 testing options, 167 using Dell PowerEdge Diagnostics, 165 when to use, 166 DIMMs See memory modules (DIMMs). drive ...
...B batteries troubleshooting, 152 battery troubleshooting the RAID card battery, 161 battery (system) replacing, 130 blank hard drive, 90 BMC configuring, 76 C CD drive troubleshooting, 158 connectors USB, 12, 19 video, 12, 19 contacting Dell, 177 control panel assembly features, 12 ...136 cooling fans troubleshooting, 154 cover closing, 86 D damaged systems troubleshooting, 152 Dell contacting, 177 Dell PowerEdge Diagnostics using, 165 diagnostics advanced testing options, 167 testing options, 167 using Dell PowerEdge Diagnostics, 165 when to use, 166 DIMMs See memory modules (DIMMs). drive ...
Hardware Owner's Manual
Page 192
startup accessing system features, 11 support contacting Dell, 177 system closing, 86 system cooling troubleshooting, 154 system features accessing, 11 system password, 72 system setup options, 59 system setup program CPU options, 62 ... expansion card, 162 external connections, 148 hard drive, 160 internal USB key, 157 keyboard, 148 memory, 155 microprocessors, 163 NIC, 149 power supplies, 153 SAS RAID controller daughter card, 161 SD card, 157 system cooling, 154 system startup failure, 147 video, 148 Index 192 S safety, 147 SAS backplane board installing, 140...
startup accessing system features, 11 support contacting Dell, 177 system closing, 86 system cooling troubleshooting, 154 system features accessing, 11 system password, 72 system setup options, 59 system setup program CPU options, 62 ... expansion card, 162 external connections, 148 hard drive, 160 internal USB key, 157 keyboard, 148 memory, 155 microprocessors, 163 NIC, 149 power supplies, 153 SAS RAID controller daughter card, 161 SD card, 157 system cooling, 154 system startup failure, 147 video, 148 Index 192 S safety, 147 SAS backplane board installing, 140...