Page 3
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell Contax\Dell_ContaxUG_PrintTOC.fm Table of Contents 1 Preface 13 2 Features 14 IP Version 6 (IPv6) Support 15 Stack Support 15 Power over Ethernet 15 Green Ethernet 16 Head of Line Blocking Prevention 16 Flow Control Support (IEEE 802.3X 16 Back Pressure Support 16 Virtual Cable Testing (VCT 17 Auto-Negotiation 17 MDI/MDIX Support 17 MAC Address Supported Features 17 Layer 2 Features 19 IGMP Snooping 19 Port Mirroring 19 Broadcast Storm Control 19 VLAN Supported Features 20 Contents 3
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell Contax\Dell_ContaxUG_PrintTOC.fm Table of Contents 1 Preface 13 2 Features 14 IP Version 6 (IPv6) Support 15 Stack Support 15 Power over Ethernet 15 Green Ethernet 16 Head of Line Blocking Prevention 16 Flow Control Support (IEEE 802.3X 16 Back Pressure Support 16 Virtual Cable Testing (VCT 17 Auto-Negotiation 17 MDI/MDIX Support 17 MAC Address Supported Features 17 Layer 2 Features 19 IGMP Snooping 19 Port Mirroring 19 Broadcast Storm Control 19 VLAN Supported Features 20 Contents 3
User Guide
Page 14
...Notes. For a complete list of the PowerConnect 5524/P and 5548/P switches. This section contains the following topics: • IP Version 6 (IPv6) Support • Stack Support • Power over Ethernet •...; Green Ethernet • Head of Line Blocking Prevention • Flow Control Support (IEEE 802.3X) • Back Pressure Support • Virtual Cable...; Device Management Features Dell PowerConnect 55xx Systems User Guide 14
...Notes. For a complete list of the PowerConnect 5524/P and 5548/P switches. This section contains the following topics: • IP Version 6 (IPv6) Support • Stack Support • Power over Ethernet •...; Green Ethernet • Head of Line Blocking Prevention • Flow Control Support (IEEE 802.3X) • Back Pressure Support • Virtual Cable...; Device Management Features Dell PowerConnect 55xx Systems User Guide 14
User Guide
Page 15
When PoE is recommended to use HDMI cable version 1.4 The stacking feature supports the following applications: • IP Phones • Wireless Access Points Dell PowerConnect 55xx Systems User Guide 15 The HDMI ports are 1.3a specification, Category 2 High Speed cables, 340 MHz (10.2 Gbit/s). PoE ...on page 43 Power over Ethernet Power over existing LAN cabling, without updating or modifying the network infrastructure. Stack Support The system supports up to be used in a pure IPv6 network as well as dual stack). This enables device operation in the following features: ...
When PoE is recommended to use HDMI cable version 1.4 The stacking feature supports the following applications: • IP Phones • Wireless Access Points Dell PowerConnect 55xx Systems User Guide 15 The HDMI ports are 1.3a specification, Category 2 High Speed cables, 340 MHz (10.2 Gbit/s). PoE ...on page 43 Power over Ethernet Power over existing LAN cabling, without updating or modifying the network infrastructure. Stack Support The system supports up to be used in a pure IPv6 network as well as dual stack). This enables device operation in the following features: ...
User Guide
Page 35
Dell PowerConnect 55xx Systems User Guide 35 They are 24 G ports and not 48. The default baud rate is used for debugging and software downloads. Figure 5-2 shows ... are 1.3a specification, category 2 high-speed cables, 340 MHz (10.2 Gbit/s). PowerConnect 5548 Ports Giga Ports (odd numbered) ConsoleUSB Port Port HDMI Ports Giga Ports (even numbered) SPF+ Ports The following ports are found on the right side in that there are used for a terminal connection for stacking purposes. The SFP+ ports are 10...
Dell PowerConnect 55xx Systems User Guide 35 They are 24 G ports and not 48. The default baud rate is used for debugging and software downloads. Figure 5-2 shows ... are 1.3a specification, category 2 high-speed cables, 340 MHz (10.2 Gbit/s). PowerConnect 5548 Ports Giga Ports (odd numbered) ConsoleUSB Port Port HDMI Ports Giga Ports (even numbered) SPF+ Ports The following ports are found on the right side in that there are used for a terminal connection for stacking purposes. The SFP+ ports are 10...
User Guide
Page 36
... that is activated by power-up or low-voltage conditions. 36 Dell PowerConnect 55xx Systems User Guide Button/LED Panel Console Port Stacking Unit ID Reset Power Status Fan RPS Port LEDs Master These LEDs are described in addition to use HDMI cable version 1.4 • Single USB Port This port is used for firmware...
... that is activated by power-up or low-voltage conditions. 36 Dell PowerConnect 55xx Systems User Guide Button/LED Panel Console Port Stacking Unit ID Reset Power Status Fan RPS Port LEDs Master These LEDs are described in addition to use HDMI cable version 1.4 • Single USB Port This port is used for firmware...
User Guide
Page 45
.... To connect the units in addition, continuously monitors the existence and operation of the stack. Runs as a slave unit, as described above, and in the stack: 1 Insert one end of an HDMI cable into the left-hand HDMI port on the Master's CPU to the right-hand HDMI... the left-hand HDMI port of the unit at the bottom of the stack to control and manage the resources of the slave unit. • Master Backup - Dell PowerConnect 55xx Systems User Guide 45 This step provides increased bandwidth and redundancy. Stacking Units PowerConnect 5500 series switches use two HDMI 10G ports for...
.... To connect the units in addition, continuously monitors the existence and operation of the stack. Runs as a slave unit, as described above, and in the stack: 1 Insert one end of an HDMI cable into the left-hand HDMI port on the Master's CPU to the right-hand HDMI... the left-hand HDMI port of the unit at the bottom of the stack to control and manage the resources of the slave unit. • Master Backup - Dell PowerConnect 55xx Systems User Guide 45 This step provides increased bandwidth and redundancy. Stacking Units PowerConnect 5500 series switches use two HDMI 10G ports for...
User Guide
Page 56
... Ctrl keys. Figure 5-1. b Set the data rate to the terminal through a terminal desktop system that the setting is performed only from the stack master (Unit ID 1 or 2). 56 Dell PowerConnect 55xx Systems User Guide NOTE: You can connect a console to the Terminal The switch is configured and monitored through the console port. The..., and no parity. Connecting the Switch to the console port on the front panel of a desktop system running terminal emulation software. 2 Connect the RS-232 cable to the switch.
... Ctrl keys. Figure 5-1. b Set the data rate to the terminal through a terminal desktop system that the setting is performed only from the stack master (Unit ID 1 or 2). 56 Dell PowerConnect 55xx Systems User Guide NOTE: You can connect a console to the Terminal The switch is configured and monitored through the console port. The..., and no parity. Connecting the Switch to the console port on the front panel of a desktop system running terminal emulation software. 2 Connect the RS-232 cable to the switch.
User Guide
Page 249
...: Summary page. Figure 9-29. To perform a cable test and view the results: 1 Click System > Diagnostics > Integrated Cable Test: Summary in the down state, with the exception of Approximated Cable Length test. Integrated Cable Test: Summary 2 Select a unit in the stack in the Unit ID field. Dell PowerConnect 55xx Systems User Guide 249 Results from previously-run tests...
...: Summary page. Figure 9-29. To perform a cable test and view the results: 1 Click System > Diagnostics > Integrated Cable Test: Summary in the down state, with the exception of Approximated Cable Length test. Integrated Cable Test: Summary 2 Select a unit in the stack in the Unit ID field. Dell PowerConnect 55xx Systems User Guide 249 Results from previously-run tests...
User Guide
Page 386
... by the local system. - Port number. - Displays the operational status of the remote link partner's Tx value. 386 Dell PowerConnect 55xx Systems User Guide Indicates the time (in micro seconds) that the transmitting link partner waits before transmission of data following settings...is not enabled - • Current Power Consumption - Short-Reach • Oper - Displays the percentage of cable. 5 Click LLDP Interface Details. 6 Select a unit in the stack to display its power consumption parameters. Resolved Rx Timer (μsec) - Displays the current power consumption. •...
... by the local system. - Port number. - Displays the operational status of the remote link partner's Tx value. 386 Dell PowerConnect 55xx Systems User Guide Indicates the time (in micro seconds) that the transmitting link partner waits before transmission of data following settings...is not enabled - • Current Power Consumption - Short-Reach • Oper - Displays the percentage of cable. 5 Click LLDP Interface Details. 6 Select a unit in the stack to display its power consumption parameters. Resolved Rx Timer (μsec) - Displays the current power consumption. •...
User Guide
Page 711
...12 - FOR PROOF ONLY 711 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell Contax\Dell_ContaxUG_PrintIX.fm Auto update, configuration/image Cipher Block-Chaining 308 file 331 Class ..., 450, 697 Configuration Work Flow 55 BPDU Guard 22 Configuring Login Banners 74 BPDU Handling 432 Configuring the Stack 58 Bridge Multicast Forward All 517 Configuring the Switch 54 Bridge Multicast Groups 513 Bridge Protocol Data Unit 697 Broadcast...files 355 CoS 697 CoS 802.1p support 23 C CoS to Queue 650 Cables testing 249 Counter Summary 602 CBC 308 CPU Utilization 638...
...12 - FOR PROOF ONLY 711 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell Contax\Dell_ContaxUG_PrintIX.fm Auto update, configuration/image Cipher Block-Chaining 308 file 331 Class ..., 450, 697 Configuration Work Flow 55 BPDU Guard 22 Configuring Login Banners 74 BPDU Handling 432 Configuring the Stack 58 Bridge Multicast Forward All 517 Configuring the Switch 54 Bridge Multicast Groups 513 Bridge Protocol Data Unit 697 Broadcast...files 355 CoS 697 CoS 802.1p support 23 C CoS to Queue 650 Cables testing 249 Counter Summary 602 CBC 308 CPU Utilization 638...
User Guide
Page 727
... of using HDMI cable version to customer Dell PowerConnect 55xx Systems User Guide 727 A2 Sept 21, 2011 Entered comment that enabling iSCSI also enables flow control on page 331 A4 April 4, 2012 Made the following corrections: • Put a the note (of the recommendation of using HDMI cable version to 1.4 for stacking A3 Jan 31...
... of using HDMI cable version to customer Dell PowerConnect 55xx Systems User Guide 727 A2 Sept 21, 2011 Entered comment that enabling iSCSI also enables flow control on page 331 A4 April 4, 2012 Made the following corrections: • Put a the note (of the recommendation of using HDMI cable version to 1.4 for stacking A3 Jan 31...