FS726T User Manual
Page 4
....1Q Tag VLAN 3-7 Switch> Trunking Page 3-9 Switch> Monitor Page 3-10 Switch> Advanced> Jumbo Frame 3-10 Switch> Advanced> Spanning Tree Page 3-11 Switch> Advanced> SNMP 3-11 Firmware Menu ...3-12 Firmware> Configuration Backup Page 3-12 Firmware...Based VLAN Port-based VLANs ...A-1 Example ...A-1 Scenarios: ...A-2 Appendix D Cabling Guidelines Fast Ethernet Cable Guidelines B-1 Category 5 Cable ...B-2 Category 5 Cable Specifications B-2 Twisted Pair Cables B-3 Patch Panels and Cables B-4 Using 1000BASE-T Gigabit Ethernet over Category 5 Cable B-5 Cabling ...B-5 Near End Cross Talk (...
....1Q Tag VLAN 3-7 Switch> Trunking Page 3-9 Switch> Monitor Page 3-10 Switch> Advanced> Jumbo Frame 3-10 Switch> Advanced> Spanning Tree Page 3-11 Switch> Advanced> SNMP 3-11 Firmware Menu ...3-12 Firmware> Configuration Backup Page 3-12 Firmware...Based VLAN Port-based VLANs ...A-1 Example ...A-1 Scenarios: ...A-2 Appendix D Cabling Guidelines Fast Ethernet Cable Guidelines B-1 Category 5 Cable ...B-2 Category 5 Cable Specifications B-2 Twisted Pair Cables B-3 Patch Panels and Cables B-4 Using 1000BASE-T Gigabit Ethernet over Category 5 Cable B-5 Cabling ...B-5 Near End Cross Talk (...
FS726T User Manual
Page 6
...://www.netgear.com/support/main.asp. 1-2 About This Guide July 2005 DOS file and directory names. This manual is written for the Smart Switch Series Switch according to highlight special messages: Note: This format is used to highlight information of the Switching, SNMP, Config, and Management packages. Manual Specifications Product Version Manual Publication Date Smart Switch Series Switch July...
...://www.netgear.com/support/main.asp. 1-2 About This Guide July 2005 DOS file and directory names. This manual is written for the Smart Switch Series Switch according to highlight special messages: Note: This format is used to highlight information of the Switching, SNMP, Config, and Management packages. Manual Specifications Product Version Manual Publication Date Smart Switch Series Switch July...
FS726T User Manual
Page 18
...IP Address to disable the DHCP function. • Enter site-specific IP address, Subnet mask and Gateway in the Re-type ... The possible entries are 4 options available: • Port Configuration • Statistics • VLAN • Trunking Switch> Port Configuration Page You can be changed here. • Type the old password in the Old Password field ...port number on the screen and will display as a sequence of 20. Smart Switch Series Software Manual • The DHCP function is Auto-negotiation (Auto). Switch Menu There are Auto-negotiation (Auto), 10 Mbps half duplex (10M Half...
...IP Address to disable the DHCP function. • Enter site-specific IP address, Subnet mask and Gateway in the Re-type ... The possible entries are 4 options available: • Port Configuration • Statistics • VLAN • Trunking Switch> Port Configuration Page You can be changed here. • Type the old password in the Old Password field ...port number on the screen and will display as a sequence of 20. Smart Switch Series Software Manual • The DHCP function is Auto-negotiation (Auto). Switch Menu There are Auto-negotiation (Auto), 10 Mbps half duplex (10M Half...
FS726T User Manual
Page 32
...for a given port means that packets leaving the switch from that port's VLAN membership properties. Modify PVID Setting to apply previous two VLAN groups: Modify Default VLAN group (VLAN ID = 1) to apply two new VLAN groups: The specific ports above have membership with the VLAN specified ...the VLAN membership. A 'U' for a given port means that packets leaving the switch from that is user configurable (the default setting is 1). Smart Switch Series Software Manual IEEE 802.1Q VLANs Packets received by the switch will be treated in the following way: • When an untagged packet ...
...for a given port means that packets leaving the switch from that port's VLAN membership properties. Modify PVID Setting to apply previous two VLAN groups: Modify Default VLAN group (VLAN ID = 1) to apply two new VLAN groups: The specific ports above have membership with the VLAN specified ...the VLAN membership. A 'U' for a given port means that packets leaving the switch from that is user configurable (the default setting is 1). Smart Switch Series Software Manual IEEE 802.1Q VLANs Packets received by the switch will be treated in the following way: • When an untagged packet ...
FS726T User Manual
Page 36
The specific ports above have to remove the ports that VLAN. Port 18, Port 21 - Port 8, for Sales department, port 7 and 8 connect to file archives and printer ... message. C-2 Port-Based VLAN July 2005 Port 24, Port 26, for Marketing department, port 7 and 8 connect to file archives and printer server. • VLAN 3: Port 7 - Smart Switch Series Software Manual • Setting up first VLAN group (IT), VLAN ID = 01, with membership of connecting file server and printer server. Scenarios: If a packet...
The specific ports above have to remove the ports that VLAN. Port 18, Port 21 - Port 8, for Sales department, port 7 and 8 connect to file archives and printer ... message. C-2 Port-Based VLAN July 2005 Port 24, Port 26, for Marketing department, port 7 and 8 connect to file archives and printer server. • VLAN 3: Port 7 - Smart Switch Series Software Manual • Setting up first VLAN group (IT), VLAN ID = 01, with membership of connecting file server and printer server. Scenarios: If a packet...
FS726T User Manual
Page 37
... Guidelines D-1 July 2005 Appendix D Cabling Guidelines This appendix provides specifications for 100BASE-TX.The specification requires Category 5 UTP cable consisting of either two-pair or four-pair twisted insulated copper conductors bound in the IEEE 802.3u standard for cables used with a NETGEAR Smart Switch Series Switch. Termination method To minimize cross-talk noise, maintain the...
... Guidelines D-1 July 2005 Appendix D Cabling Guidelines This appendix provides specifications for 100BASE-TX.The specification requires Category 5 UTP cable consisting of either two-pair or four-pair twisted insulated copper conductors bound in the IEEE 802.3u standard for cables used with a NETGEAR Smart Switch Series Switch. Termination method To minimize cross-talk noise, maintain the...
FS726T User Manual
Page 38
... 5 Cable Specifications Ensure that meets ANSI/EIA/TIA-568-A building wiring standards can be a maximum of 328 feet (ft.) or 100 meters (m) in the wire pair is crossed over to the desktop device The patch panel and other connecting hardware must meet the requirements for 100 Mbps operation (Category 5). Smart Switch Series Software...
... 5 Cable Specifications Ensure that meets ANSI/EIA/TIA-568-A building wiring standards can be a maximum of 328 feet (ft.) or 100 meters (m) in the wire pair is crossed over to the desktop device The patch panel and other connecting hardware must meet the requirements for 100 Mbps operation (Category 5). Smart Switch Series Software...
FS726T User Manual
Page 39
...through twisted pair cable. Most repeaters and switch ports are usually media-dependent interface ports, called MDI-X or normal ports. Figure D-1: Straight-Through Twisted-Pair Cable Cabling Guidelines D-3 July 2005 Electrical Requirements of Category 5 Cable SPECIFICATIONS Number of pairs Impedance Mutual capacitance at ... each device must be connected to the receiver of the circuitry in crossover ports, called MDI or uplink ports. Smart Switch Series Software Manual Table-D-1. The crossover function is needed and makes the right connection. Computers and workstation adapter cards are...
...through twisted pair cable. Most repeaters and switch ports are usually media-dependent interface ports, called MDI-X or normal ports. Figure D-1: Straight-Through Twisted-Pair Cable Cabling Guidelines D-3 July 2005 Electrical Requirements of Category 5 Cable SPECIFICATIONS Number of pairs Impedance Mutual capacitance at ... each device must be connected to the receiver of the circuitry in crossover ports, called MDI or uplink ports. Smart Switch Series Software Manual Table-D-1. The crossover function is needed and makes the right connection. Computers and workstation adapter cards are...
FS726T User Manual
Page 41
...When using Category 5e cable, since it meets or exceeds either ANSI/EIA/TIA-568-A:1995 or ISO/ IEC 11801:1995 Category 5 specifications. Smart Switch Series Software Manual Note: Flat "silver satin" telephone cable may have been amended. All of these factors affect the performance of 1000BASE... "channel." Return Loss Return loss measures the amount of the link that it costs about the same as per the original Ethernet specification. Cabling Guidelines D-5 July 2005 However, using the existing cable, be considered. The following sections are patch panel connections, twists of...
...When using Category 5e cable, since it meets or exceeds either ANSI/EIA/TIA-568-A:1995 or ISO/ IEC 11801:1995 Category 5 specifications. Smart Switch Series Software Manual Note: Flat "silver satin" telephone cable may have been amended. All of these factors affect the performance of 1000BASE... "channel." Return Loss Return loss measures the amount of the link that it costs about the same as per the original Ethernet specification. Cabling Guidelines D-5 July 2005 However, using the existing cable, be considered. The following sections are patch panel connections, twists of...
FS726T User Manual
Page 42
... Ethernet network, it supports 10 Mbps, 100 Mbps, or 1000 Mbps data transmission. it is important. Removing the jacket that do not meet Category 5e specifications. Cabling or bundling of the twisted pair. The cross-talk performance is "returned" to 3/8 inch (10 mm) for successful operation. As pointed out in the... the NEXT section, this is important that , when RJ-45 connections are tested ⎯ this near end of wires within a bundle. D-6 Cabling Guidelines July 2005 Smart Switch Series Software Manual Unlike 10BASE-T and 100BASE-TX, which use RJ-45 plugs.
... Ethernet network, it supports 10 Mbps, 100 Mbps, or 1000 Mbps data transmission. it is important. Removing the jacket that do not meet Category 5e specifications. Cabling or bundling of the twisted pair. The cross-talk performance is "returned" to 3/8 inch (10 mm) for successful operation. As pointed out in the... the NEXT section, this is important that , when RJ-45 connections are tested ⎯ this near end of wires within a bundle. D-6 Cabling Guidelines July 2005 Smart Switch Series Software Manual Unlike 10BASE-T and 100BASE-TX, which use RJ-45 plugs.
FS726T User Manual
Page 44
Install Category 5e cable where possible, including patch panel cables. Smart Switch Series Software Manual Table-D-3. 100/1000 Mbps RJ-45 Plug and RJ-45 Connector Pin Assignments PIN 1 2 3 6 4 5 7 8 CHANNEL A B C D DESCRIPTION Rx/Tx Data + Rx/Tx Data ... must be properly installed to fully qualify your 1000BASE-T product, it meets or exceeds ANSI/EIA/TIA-568-A:1995 or ISO/IEC 11801:1995 Category 5 specifications. Bundling of your cable installation and ensure it is important to meet the requirements in ANSI/EIA/TIA-568A-3. Minimize transition points, jacket removal, and...
Install Category 5e cable where possible, including patch panel cables. Smart Switch Series Software Manual Table-D-3. 100/1000 Mbps RJ-45 Plug and RJ-45 Connector Pin Assignments PIN 1 2 3 6 4 5 7 8 CHANNEL A B C D DESCRIPTION Rx/Tx Data + Rx/Tx Data ... must be properly installed to fully qualify your 1000BASE-T product, it meets or exceeds ANSI/EIA/TIA-568-A:1995 or ISO/IEC 11801:1995 Category 5 specifications. Bundling of your cable installation and ensure it is important to meet the requirements in ANSI/EIA/TIA-568A-3. Minimize transition points, jacket removal, and...
FS726T Hardware manual
Page 3
...3: APPLICATIONS...11 DESKTOP SWITCHING ...11 CHAPTER 4: INSTALLATION...12 STEP 1: PREPARING THE SITE ...12 STEP 2: INSTALLING THE SWITCH ...12 STEP 3: CHECKING THE INSTALLATION ...13 STEP 4: CONNECTING DEVICES TO THE SWITCH ...13 STEP 5: ...INSTALLING AN SFP GBIC MODULE...13 STEP 6: APPLYING AC POWER ...14 STEP 7: SWITCH MANAGEMENT THROUGH A WEB BROWSER OR THE PC UTILITY FOR INITIAL CONFIGURATION 14 APPENDIX A: GLOSSARY ...15 APPENDIX B: TROUBLESHOOTING ...17 TROUBLESHOOTING CHART...17 ADDITIONAL TROUBLESHOOTING SUGGESTIONS ...17 APPENDIX C: TECHNICAL SPECIFICATIONS...
...3: APPLICATIONS...11 DESKTOP SWITCHING ...11 CHAPTER 4: INSTALLATION...12 STEP 1: PREPARING THE SITE ...12 STEP 2: INSTALLING THE SWITCH ...12 STEP 3: CHECKING THE INSTALLATION ...13 STEP 4: CONNECTING DEVICES TO THE SWITCH ...13 STEP 5: ...INSTALLING AN SFP GBIC MODULE...13 STEP 6: APPLYING AC POWER ...14 STEP 7: SWITCH MANAGEMENT THROUGH A WEB BROWSER OR THE PC UTILITY FOR INITIAL CONFIGURATION 14 APPENDIX A: GLOSSARY ...15 APPENDIX B: TROUBLESHOOTING ...17 TROUBLESHOOTING CHART...17 ADDITIONAL TROUBLESHOOTING SUGGESTIONS ...17 APPENDIX C: TECHNICAL SPECIFICATIONS...
FS726T Hardware manual
Page 12
...ports, view the front panel LEDs, and access power connector. Install the switch in a dry area, with your switch. Do not restrict airflow by a wall switch, which can install your NETGEAR ProSafe FS726T Smart Switch. Be sure there is adequate airflow in a position that is not ...head screws with a #1 Phillips screwdriver to the switch Step 5: Installing an SFP GBIC module Step 6: Apply AC power Step 7: Switch management through each bracket and into the bracket mounting holes in the switch. 3. Power specifications for the switch are shown in a rack, use the following ...
...ports, view the front panel LEDs, and access power connector. Install the switch in a dry area, with your switch. Do not restrict airflow by a wall switch, which can install your NETGEAR ProSafe FS726T Smart Switch. Be sure there is adequate airflow in a position that is not ...head screws with a #1 Phillips screwdriver to the switch Step 5: Installing an SFP GBIC module Step 6: Apply AC power Step 7: Switch management through each bracket and into the bracket mounting holes in the switch. 3. Power specifications for the switch are shown in a rack, use the following ...
FS726T Hardware manual
Page 13
... unshielded twisted-pair (UTP) cable terminated with an RJ-45 connector to the switch's RJ-45 ports. Press firmly to install an SFP GBIC module at this time, skip this procedure. Your NETGEAR ProSafe FS726T Smart Switch contains Auto Uplink™ technology, which allows you do not want to ensure the... Page 13 of 19 Step 4: Connecting Devices to the Switch The following procedure describes how to attach devices using either straight-through or crossover cables. Note: Ethernet specifications limit the cable length between the switch and the attached device to an RJ-45 network port ...
... unshielded twisted-pair (UTP) cable terminated with an RJ-45 connector to the switch's RJ-45 ports. Press firmly to install an SFP GBIC module at this time, skip this procedure. Your NETGEAR ProSafe FS726T Smart Switch contains Auto Uplink™ technology, which allows you do not want to ensure the... Page 13 of 19 Step 4: Connecting Devices to the Switch The following procedure describes how to attach devices using either straight-through or crossover cables. Note: Ethernet specifications limit the cable length between the switch and the attached device to an RJ-45 network port ...
FS726T Hardware manual
Page 15
... and alerting administrators about connections (such as four octets separated with switching technology. 10BASE-T The IEEE specification for 10 Mbps Ethernet over Category 3, 4, or 5 twisted-pair cable. 100BASE-FX The IEEE specification for 100 Mbps Fast Ethernet over fiber-optic cable. 100BASE-TX ... Fast Ethernet over Category 5 twisted-pair cable. 1000BASE-SX The IEEE specification for 1000 Mbps Gigabit Ethernet over fiber-optic cable. 1000BASE-T The IEEE specification for certain characteristics, such as a switch, to already overloaded port on a network. IP is part of the...
... and alerting administrators about connections (such as four octets separated with switching technology. 10BASE-T The IEEE specification for 10 Mbps Ethernet over Category 3, 4, or 5 twisted-pair cable. 100BASE-FX The IEEE specification for 100 Mbps Fast Ethernet over fiber-optic cable. 100BASE-TX ... Fast Ethernet over Category 5 twisted-pair cable. 1000BASE-SX The IEEE specification for 1000 Mbps Gigabit Ethernet over fiber-optic cable. 1000BASE-T The IEEE specification for certain characteristics, such as a switch, to already overloaded port on a network. IP is part of the...
FS726T Hardware manual
Page 16
...they were physically connected to monitor the traffic passing through a network - IP relates to a user. A single packet sent to a specific group of the end station to which devices have a MAC address assigned to bridges, in one route exists between devices on a device ...Protocol. An IETF standard protocol for network resilience, without the broadcast storms associated with another device or the network. If a switch or bridge falls, a new path to analyze network characteristics and perform troubleshooting. also called hardware or physical address. Most devices ...
...they were physically connected to monitor the traffic passing through a network - IP relates to a user. A single packet sent to a specific group of the end station to which devices have a MAC address assigned to bridges, in one route exists between devices on a device ...Protocol. An IETF standard protocol for network resilience, without the broadcast storms associated with another device or the network. If a switch or bridge falls, a new path to analyze network characteristics and perform troubleshooting. also called hardware or physical address. Most devices ...
FS726T Hardware manual
Page 17
... meet Ethernet guidelines. Page 17 of possible problems. Table B-1. APPENDIX B: TROUBLESHOOTING This chapter provides information about troubleshooting the NETGEAR ProSafe FS726T Smart Switch. Topics include: o Troubleshooting chart o Additional troubleshooting suggestions Troubleshooting Chart Table B-1 lists symptoms, causes, and solutions of ...the PCs are correct and comply with Ethernet specifications. Network Adapter Cards Make sure the network adapter cards installed in Table B-1 do not exceed the Ethernet limitations. Switch Integrity If required, verify the integrity of North...
... meet Ethernet guidelines. Page 17 of possible problems. Table B-1. APPENDIX B: TROUBLESHOOTING This chapter provides information about troubleshooting the NETGEAR ProSafe FS726T Smart Switch. Topics include: o Troubleshooting chart o Additional troubleshooting suggestions Troubleshooting Chart Table B-1 lists symptoms, causes, and solutions of ...the PCs are correct and comply with Ethernet specifications. Network Adapter Cards Make sure the network adapter cards installed in Table B-1 do not exceed the Ethernet limitations. Switch Integrity If required, verify the integrity of North...
FS726T Hardware manual
Page 18
...EN60950 Page 18 of Service (CoS) Port-based QoS (options High/Normal) Port Trunking - APPENDIX C: TECHNICAL SPECIFICATIONS This appendix provides technical specifications for 100 Mbps to 100 Mbps transmission Buffer memory: 256 KB embedded memory per unit Address database size: 8,...Power Supply Power Consumption: 15 W maximum 100-240VAC/50-60 Hz universal input Physical Specifications Dimensions (H x W x D): 1.6 x 17.3 x 8.1 in store-and-forward mode for the NETGEAR ProSafe FS726T Smart Switch. Manual as per IEEE802.3ad Link Aggregation Interface 24 RJ-45 connectors for 10BASE-T, 100BASE...
...EN60950 Page 18 of Service (CoS) Port-based QoS (options High/Normal) Port Trunking - APPENDIX C: TECHNICAL SPECIFICATIONS This appendix provides technical specifications for 100 Mbps to 100 Mbps transmission Buffer memory: 256 KB embedded memory per unit Address database size: 8,...Power Supply Power Consumption: 15 W maximum 100-240VAC/50-60 Hz universal input Physical Specifications Dimensions (H x W x D): 1.6 x 17.3 x 8.1 in store-and-forward mode for the NETGEAR ProSafe FS726T Smart Switch. Manual as per IEEE802.3ad Link Aggregation Interface 24 RJ-45 connectors for 10BASE-T, 100BASE...