External Control NEC LCD Monitor 1. Connectors and wiring Connector: D-Sub 9-pin Cable: Cross (reversed) cable or null modem cable (Please refer "Using the LCD with RS-232C" on each User's manual.) 3. Communication Parameter (1) Communication system Asynchronous (2) Interface RS-232C (3) Baud rate 9600bps (4) Data length 8bits (5) Parity None (6) Stop bit 1 bit (7) Communication code ASCII 3.1 Communication timing The controller should wait for the LCD monitor. (1/40) The packet interval needs to...
External Control NEC LCD Monitor 1. Connectors and wiring Connector: D-Sub 9-pin Cable: Cross (reversed) cable or null modem cable (Please refer "Using the LCD with RS-232C" on each User's manual.) 3. Communication Parameter (1) Communication system Asynchronous (2) Interface RS-232C (3) Baud rate 9600bps (4) Data length 8bits (5) Parity None (6) Stop bit 1 bit (7) Communication code ASCII 3.1 Communication timing The controller should wait for the LCD monitor. (1/40) The packet interval needs to...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 3
...) 'P'(50h) 'Q'(51h) 'R'(52h) 'S'(53h) 'T'(54h) 'U'(55h) 'V'(56h) 'W'(57h) 'X'(58h) 'Y'(59h) 'Z'(5Ah) Ex.) If you want to control a monitor that follows the header) from a monitor. The controller must be '0' (30h). 5thbyte) Message Type: (Case sensitive.) Refer to section 4.2 "Message block format" for more details. "Monitor ID" to "Destination Address" conversion table is allied to the "Message Type" in the "Header".
...) 'P'(50h) 'Q'(51h) 'R'(52h) 'S'(53h) 'T'(54h) 'U'(55h) 'V'(56h) 'W'(57h) 'X'(58h) 'Y'(59h) 'Z'(5Ah) Ex.) If you want to control a monitor that follows the header) from a monitor. The controller must be '0' (30h). 5thbyte) Message Type: (Case sensitive.) Refer to section 4.2 "Message block format" for more details. "Monitor ID" to "Destination Address" conversion table is allied to the "Message Type" in the "Header".
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 4
... with this message for more details. 3 Set parameter The controller sends this message to change a setting of the "Get parameter reply" is used for more details. 6 Command reply The monitor replies to a query from a monitor." Usually, this "command message" is as follows, STX Result OP code page OP code Type Max value Requested setting Value ETX Hi Lo Hi Lo Hi...
... with this message for more details. 3 Set parameter The controller sends this message to change a setting of the "Get parameter reply" is used for more details. 6 Command reply The monitor replies to a query from a monitor." Usually, this "command message" is as follows, STX Result OP code page OP code Type Max value Requested setting Value ETX Hi Lo Hi Lo Hi...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 7
...(31h and 41h). 8th -9thbytes) Type: Operation type code 00h: Set parameter 01h: Momentary Like the Auto Setup function which monitor can accept. (16bits) This returned value from the monitor is encoded to ASCII characters. The controller requests a monitor to ASCII character '0' and '1' (30h...automatically changes the parameter. This returned value from the monitor is encoded to change monitor's adjustment and so on. This result code from the monitor is encoded to the operation code table. 6th -7thbytes) OP code: Operation code These bytes indicate a replying item's OP code. ...
...(31h and 41h). 8th -9thbytes) Type: Operation type code 00h: Set parameter 01h: Momentary Like the Auto Setup function which monitor can accept. (16bits) This returned value from the monitor is encoded to ASCII characters. The controller requests a monitor to ASCII character '0' and '1' (30h...automatically changes the parameter. This returned value from the monitor is encoded to change monitor's adjustment and so on. This result code from the monitor is encoded to the operation code table. 6th -7thbytes) OP code: Operation code These bytes indicate a replying item's OP code. ...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 9
...- ETX LSB (9/40) ASCII '0''0' (30h, 30h): Set parameter ASCII '0''1' (30h, 31h): Momentary Like Auto Setup function, that monitor can accept. (16bits) Reply data from the monitor is out of Message ASCII ETX (03h) 5.5 Commands "Command message format" depends on each command. Refer to section 7 to store the adjusted value. STX Command code ETX '0' 'C' Send "OC"(30h, 43h...
...- ETX LSB (9/40) ASCII '0''0' (30h, 30h): Set parameter ASCII '0''1' (30h, 31h): Momentary Like Auto Setup function, that monitor can accept. (16bits) Reply data from the monitor is out of Message ASCII ETX (03h) 5.5 Commands "Command message format" depends on each command. Refer to section 7 to store the adjusted value. STX Command code ETX '0' 'C' Send "OC"(30h, 43h...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 10
... "Save current settings". 6.1. Typical procedure example The following cases; A timeout error has occurred. (The default timeout is 10sec.) The monitor receives an unsupported message type. The monitor detects a packet BCC (Block Check Code) error. To tell the controller that the monitor does not have any answer to give to support this operation. (Get parameter) Header Message SOH-'0'-Monitor ID-'0'-'C'-'0'-'6' STX...
... "Save current settings". 6.1. Typical procedure example The following cases; A timeout error has occurred. (The default timeout is 10sec.) The monitor receives an unsupported message type. The monitor detects a packet BCC (Block Check Code) error. To tell the controller that the monitor does not have any answer to give to support this operation. (Get parameter) Header Message SOH-'0'-Monitor ID-'0'-'C'-'0'-'6' STX...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 11
... section 4.5 "Check code" for a BCC calculation. The controller request the monitor to change the Brightness setting Header SOH-'0'-Monitor ID-'0'-'E'-'0'-'A' Message STX-'0'-'0'-'1'-'0'-'0'-'0'-'5'-'0'-ETX Check code BCC Header SOH (01h): Start Of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of Message '0'-'0' (30h, 30h): Operation code page number is 0. '1'-'0' (31h, 30h): Operation code is 10h (in the page 0). '0'-'0' (30h, 30h): This operation is "Set parameter" type. '0'-'0'-'6'-'4' (30h...
... section 4.5 "Check code" for a BCC calculation. The controller request the monitor to change the Brightness setting Header SOH-'0'-Monitor ID-'0'-'E'-'0'-'A' Message STX-'0'-'0'-'1'-'0'-'0'-'0'-'5'-'0'-ETX Check code BCC Header SOH (01h): Start Of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of Message '0'-'0' (30h, 30h): Operation code page number is 0. '1'-'0' (31h, 30h): Operation code is 10h (in the page 0). '0'-'0' (30h, 30h): This operation is "Set parameter" type. '0'-'0'-'6'-'4' (30h...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 12
... temperature sensors. Select a temperature sensor which you want to store the setting. Monitor ID: Indicate a replying Monitor ID. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller. 'A' (41h): Message type is "Command". '0'-'4' (30h, 34h): Message length is the controller. Header SOH-'0'-'0'- No error. '0'-'0' (30h, 30h): Operation code page number is 0. '1'-'0' (31h, 30h): Operation code is 100(0064h). '0'-'0'-'5'-'0' (30h, 30h, 35h, 30h): Received a Brightness setting...
... temperature sensors. Select a temperature sensor which you want to store the setting. Monitor ID: Indicate a replying Monitor ID. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller. 'A' (41h): Message type is "Command". '0'-'4' (30h, 34h): Message length is the controller. Header SOH-'0'-'0'- No error. '0'-'0' (30h, 30h): Operation code page number is 0. '1'-'0' (31h, 30h): Operation code is 100(0064h). '0'-'0'-'5'-'0' (30h, 30h, 35h, 30h): Received a Brightness setting...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 13
... Message Check code BCC: Block Check Code Refer to the section 4.5 "Check code" for a BCC calculation. Monitor ID: Indicates a replying Monitor ID. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller. 'E' (45h): Message Type is "Set parameter command". '0'-'A' (30h, 41h): Message length is "Set parameter" type. '0'-'0'-'0'-'3' (30h, 30h, 30h, 33h): Number of Message Check code BCC: Block Check Code Refer to...
... Message Check code BCC: Block Check Code Refer to the section 4.5 "Check code" for a BCC calculation. Monitor ID: Indicates a replying Monitor ID. Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller. 'E' (45h): Message Type is "Set parameter command". '0'-'A' (30h, 41h): Message length is "Set parameter" type. '0'-'0'-'0'-'3' (30h, 30h, 30h, 33h): Number of Message Check code BCC: Block Check Code Refer to...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 14
... the controller. 'C' (43h): Message Type is "Get parameter". '0'-'6' (30h, 36h): Message length is 2's complement. Ex.) When this byte is set to the section 4.5 "Check code" for a BCC calculation. The monitor replies a temperature of Header '0' (30h): Reserved '0' (30h): Message receiver is 18 bytes. Header Message Check code SOH-'0'-'0'-Monitor ID-'D'-'1'-'2' STX-'0'-'0'-'0'-'2'-'7'-'9'-'0'-'0' BCC -'F'-'F'-'F'-'F'-'0'-'0'-'3'-'2'-ETX Header SOH (01h): Start of selected sensor...
... the controller. 'C' (43h): Message Type is "Get parameter". '0'-'6' (30h, 36h): Message length is 2's complement. Ex.) When this byte is set to the section 4.5 "Check code" for a BCC calculation. The monitor replies a temperature of Header '0' (30h): Reserved '0' (30h): Message receiver is 18 bytes. Header Message Check code SOH-'0'-'0'-Monitor ID-'D'-'1'-'2' STX-'0'-'0'-'0'-'2'-'7'-'9'-'0'-'0' BCC -'F'-'F'-'F'-'F'-'0'-'0'-'3'-'2'-ETX Header SOH (01h): Start of selected sensor...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 16
... Message Check code BCC: Block Check Code (16/40) Ex.) The byte data 20h is the controller. No error. 'C'-'2','0'-'3'-'D'-'6' (43h, 32h, 30h, 33h, 44h, 36h): power control reply command The monitor replies same as power control command to the controller. '0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Power mode 0001: ON 0002, 0003: Do not set to 'A', the replying Monitor ID is '1'. 'B' (42h): Message type is "Command...
... Message Check code BCC: Block Check Code (16/40) Ex.) The byte data 20h is the controller. No error. 'C'-'2','0'-'3'-'D'-'6' (43h, 32h, 30h, 33h, 44h, 36h): power control reply command The monitor replies same as power control command to the controller. '0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Power mode 0001: ON 0002, 0003: Do not set to 'A', the replying Monitor ID is '1'. 'B' (42h): Message type is "Command...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 18
...receiver is encoded as ASCII characters '2' and '0' (34h and 30h). Monitor ID: Indicate a replying Monitor ID. ETX (03h): End of Message Check code BCC: Block Check Code Refer to 'A', the replying Monitor ID is '1'. 'B' (42h): Message type is "Command reply". Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller. 'A' (41h): Message type...This command is used in which you want to the monitor at a time is 32bytes. Data...monitor replies a data for confirmation. ETX (03h): End of Message Check code BCC: Block Check Code Refer to write Asset data. No error...
...receiver is encoded as ASCII characters '2' and '0' (34h and 30h). Monitor ID: Indicate a replying Monitor ID. ETX (03h): End of Message Check code BCC: Block Check Code Refer to 'A', the replying Monitor ID is '1'. 'B' (42h): Message type is "Command reply". Ex.) If Monitor ID is '1', specify 'A'. '0' (30h): Message sender is the controller. 'A' (41h): Message type...This command is used in which you want to the monitor at a time is 32bytes. Data...monitor replies a data for confirmation. ETX (03h): End of Message Check code BCC: Block Check Code Refer to write Asset data. No error...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 31
... "UNLOCK". Security Lock 13.1 Security Lock Control This command sets the condition of which you want to the section 4.5 "Check code" for a BCC calculation. If codes aren't matched with monitor resisted pass codes, then this command while waiting for Pass codes inputs, then it only checks Pass cords (and releases image muting if Pass codes are matched with them then setting isn't changed, and reply error...
... "UNLOCK". Security Lock 13.1 Security Lock Control This command sets the condition of which you want to the section 4.5 "Check code" for a BCC calculation. If codes aren't matched with monitor resisted pass codes, then this command while waiting for Pass codes inputs, then it only checks Pass cords (and releases image muting if Pass codes are matched with them then setting isn't changed, and reply error...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 33
Operation Code (OP code) Table Item Brightness OP code page 00h Contrast 00h Sharpness 00h Black Level 00h Tint 00h Color 02h Color Temperature 00h Color control 00h PICTURE Gamma Selection 02h Adaptive Contrast 02h Movie Noise 02h Settings Reduction Film Mode 02h Menu tree reset 02h (Picture) Auto Setup 00h Auto Adjust H Position 00h V Position 00h ADJUST OP code Parameter 10h 12h 8Ch 92h 90h 1Fh 54h Red: 9Bh Yellow: 9Ch Green: 9Dh Cyan: 9Eh...
Operation Code (OP code) Table Item Brightness OP code page 00h Contrast 00h Sharpness 00h Black Level 00h Tint 00h Color 02h Color Temperature 00h Color control 00h PICTURE Gamma Selection 02h Adaptive Contrast 02h Movie Noise 02h Settings Reduction Film Mode 02h Menu tree reset 02h (Picture) Auto Setup 00h Auto Adjust H Position 00h V Position 00h ADJUST OP code Parameter 10h 12h 8Ch 92h 90h 1Fh 54h Red: 9Bh Yellow: 9Ch Green: 9Dh Cyan: 9Eh...
LCD4020/4620/5220/6520, M40/M46 external control commands
Page 38
... code page 02h OP code 2Eh Volume UP/Down Mute MTS Sound Picture Mode Size PIP ON/OFF Still ON/OFF 00h 62h 00h 8Dh 02h 2Ch 02h 34h 02h 1Ah 02h 70h 02h 72h PIP Input 02h 73h Still Capture PIP H Position PIP V Position Signal Information 02h 76h 02h 74h 02h 75h 02h EAh TV-Channel UP/DOWN 00h 8Bh Parameter Remarks 1: Audio 1(PC) 2: Audio 2 3: Audio 3 4: HDMI...
... code page 02h OP code 2Eh Volume UP/Down Mute MTS Sound Picture Mode Size PIP ON/OFF Still ON/OFF 00h 62h 00h 8Dh 02h 2Ch 02h 34h 02h 1Ah 02h 70h 02h 72h PIP Input 02h 73h Still Capture PIP H Position PIP V Position Signal Information 02h 76h 02h 74h 02h 75h 02h EAh TV-Channel UP/DOWN 00h 8Bh Parameter Remarks 1: Audio 1(PC) 2: Audio 2 3: Audio 3 4: HDMI...
MPD-SBC accessory brochure
Page 1
... www.necdisplay.com Ethernet USB DVI-I output allows for government agencies 3-year warranty matches that eliminates the need for an external PC, cabling, mounting and power supply. Product specifications subject to process digital signage content. All rights reserved. These benefits make NEC's single board computer ideal for NEC Large-Screen LCD Displays Enjoy full PC functionality integrated directly within your NEC display. It provides for clean, hidden integration...
... www.necdisplay.com Ethernet USB DVI-I output allows for government agencies 3-year warranty matches that eliminates the need for an external PC, cabling, mounting and power supply. Product specifications subject to process digital signage content. All rights reserved. These benefits make NEC's single board computer ideal for NEC Large-Screen LCD Displays Enjoy full PC functionality integrated directly within your NEC display. It provides for clean, hidden integration...
SB-L007KK brochure
Page 1
... change. 2/09 ver. 2. ©2009 NEC Display Solutions of America, Inc. Product specifications subject to 140°F 155 x 40 x 287mm 0.98kg FCC-A, DOC-A, CE Installation Guide, Ferrite Core x2 3 years, parts and labor NEC Display Solutions 500 Park Boulevard, Suite 1100 Itasca, IL 60143 866-NEC-MORE www.necdisplay.com NEC Displays Supported NEC M Series 40" M40-AV 40" M40B-AV 46" M46-AV 46" M46B-AV NEC MultiSync 20 Series 40" LCD4020-AV 40...
... change. 2/09 ver. 2. ©2009 NEC Display Solutions of America, Inc. Product specifications subject to 140°F 155 x 40 x 287mm 0.98kg FCC-A, DOC-A, CE Installation Guide, Ferrite Core x2 3 years, parts and labor NEC Display Solutions 500 Park Boulevard, Suite 1100 Itasca, IL 60143 866-NEC-MORE www.necdisplay.com NEC Displays Supported NEC M Series 40" M40-AV 40" M40B-AV 46" M46-AV 46" M46B-AV NEC MultiSync 20 Series 40" LCD4020-AV 40...
SB-L008WU accessory brochure
Page 1
... need for external distribution equipment and power supply, thus providing for various digital signage applications DVI cable (2m) included - Product specifications subject to -back installations in environments such as video tiling and back-to nine screens in addition to back-to change. 12/08 ver. 1. ©2008 NEC Display Solutions of using splitters or connecting monitors to multiple sources, making it ideal for video banners, ribbons and walls in close...
... need for external distribution equipment and power supply, thus providing for various digital signage applications DVI cable (2m) included - Product specifications subject to -back installations in environments such as video tiling and back-to nine screens in addition to back-to change. 12/08 ver. 1. ©2008 NEC Display Solutions of using splitters or connecting monitors to multiple sources, making it ideal for video banners, ribbons and walls in close...
M Series color brochure
Page 1
... wall mount enhance the visual experience ¤ Environmental friendliness (RoHS-compliant, low power consumption, biodegradable plastics) maximizes the user's investment and helps them be "green" ¤ 3-year parts and labor warranty, including backlight, provides peace of ownership. ¤ Full 1080p HD resolution provides stunning detail for video and broadcast applications ¤ Built-in multi-display installations. A strong presence for precise and simplified color, color...
... wall mount enhance the visual experience ¤ Environmental friendliness (RoHS-compliant, low power consumption, biodegradable plastics) maximizes the user's investment and helps them be "green" ¤ 3-year parts and labor warranty, including backlight, provides peace of ownership. ¤ Full 1080p HD resolution provides stunning detail for video and broadcast applications ¤ Built-in multi-display installations. A strong presence for precise and simplified color, color...
M Series color brochure
Page 2
... Input Terminals RGB1 (Digital) RGB2 (Analog) RGB3 (Analog) Video 1 Video 2 Video 3 Component Video 1 (DVD/HD) Audio Output Terminals RGB Video Audio Audio Amplifier External Control Digital Tuner FEATURES Additional Features POWER Power Requirements Power Consumption (Typical) Power Consumption (Standby Mode) PHYSICAL SPECIFICATIONS Bezel Width (L/R, T/B) Dimensions (with stand) Net Weight (without stand; Specifications for multiple monitor control, IR, DDC/CI M46-2-AVT, M46B-AVT Power management, Plug and Play (DDC/CI, DDC2B), PIP (remote), multi-level zoom, FullScan, 6-axis color...
... Input Terminals RGB1 (Digital) RGB2 (Analog) RGB3 (Analog) Video 1 Video 2 Video 3 Component Video 1 (DVD/HD) Audio Output Terminals RGB Video Audio Audio Amplifier External Control Digital Tuner FEATURES Additional Features POWER Power Requirements Power Consumption (Typical) Power Consumption (Standby Mode) PHYSICAL SPECIFICATIONS Bezel Width (L/R, T/B) Dimensions (with stand) Net Weight (without stand; Specifications for multiple monitor control, IR, DDC/CI M46-2-AVT, M46B-AVT Power management, Plug and Play (DDC/CI, DDC2B), PIP (remote), multi-level zoom, FullScan, 6-axis color...