LCD4020/4620/5220/6520, M40/M46 external control commands - Page 4
...61656;
Refer to section 5.2 "Get parameter reply" for more details.
6 Command reply The monitor replies to a query from a monitor." Refer to section 5.5 "Commands message" for more details.
4 Set Parameter reply
The monitor replies with the status of the "Set parameter message".
Operation code table".
"Message format" of the "Get current parameter" is as follows,
STX
Result...
LCD4020/4620/5220/6520, M40/M46 external control commands - Page 11
...
Delimiter CR
Step 4. Delimiter CR (0Dh): End of packet
Step 3. Monitor ID: Indicate a replying Monitor ID.
Ex.) When this operation. No error. '0'-'0' (30h, 30h): Operation code page number is 0. '1'-'0' (31h, 30h): Operation code is 10h (in the page 0). '0'-'0'-'5'-'0' (30h, 30h, 35h, 30h): Set Brightness setting 80(0050h). ETX (03h): End of Message '0'-'0' (30h, 30h): Operation...
LCD4020/4620/5220/6520, M40/M46 external control commands - Page 12
... code
BCC: Block Check Code Refer to check the Brightness setting. (Recommended) Step 5.
Ex.) If Monitor ID...46 has two built-in the page 0). '0'-'0' (30h, 30h): This operation is "Set parameter" type. '0'-'0'-'6'-'4' (30h, 30h, 36h, 34h): Brightness max value is 10h (in temperature sensors. No error. '0'-'0' (30h, 30h): Operation code page number is 0. '1'-'0' (31h, 30h): Operation code...
LCD4020/4620/5220/6520, M40/M46 external control commands - Page 13
...ETX BCC
Delimiter CR
(13/40)
Header SOH (01h): Start of Message
Check code BCC: Block Check Code Refer to the section 4.5 "Check code" for a BCC calculation. Monitor ID: Indicates a replying Monitor ID. No error. '0'-'2' (30h, 32h): Operation code page number is 2. '7'-'8' (37h, 38h): Operation code is 78h (in the page 2). '0'-'0' (30h, 30h): This operation is 78h (on page...
LCD4020/4620/5220/6520, M40/M46 external control commands - Page 14
... 18 bytes.
Ex.) When this byte is set to the section 4.5 "Check code" for a BCC calculation. ETX (03h): End of Message
Check code BCC: Block Check Code Refer to get a value. SOH (01h): Start of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID which you want to the section 4.5 "Check code" for a BCC calculation.
Delimiter CR
Message...
LCD4020/4620/5220/6520, M40/M46 external control commands - Page 16
... error. 'C'-'2','0'-'3'-'D'-'6' (43h, 32h, 30h, 33h, 44h, 36h): power control reply command The monitor replies same as power control command to the controller. '0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Power mode 0001: ON 0002, 0003: Do not set . 0004: OFF (same as the power off by IR) ETX (03h): End of Message
Check code BCC: Block Check Code...
LCD4020/4620/5220/6520, M40/M46 external control commands - Page 18
ETX (03h): End of Message
Check code
BCC: Block Check Code Refer to the section 4.5 "Check code" for a BCC calculation.
(18/40) Ex.) When this byte is set to 'A', the replying Monitor ID is '1'. 'B' (42h): Message type is "Command". Ex.) The byte data 20h is encoded as ASCII characters '2' and '0' (32h and 30h). Ex.) The byte data...
LCD4020/4620/5220/6520, M40/M46 external control commands - Page 29
...of Message
Check code BCC: Block Check Code Refer to the section 4.5 "Check code" for a BCC calculation. data to get serial number. Header
Message
Check code
SOH-'0'-Monitor ID-'0'-'A'-'0'-'6' STX-'C'-'2'-'1'-'6'-...packet
2) The monitor replies the serial No. Ex.) When this byte is set to read a serial number.
1) The controller requests the monitor to 'A', the replying Monitor ID is ...
LCD4020/4620/5220/6520, M40/M46 external control commands - Page 30
...;
These data are encoded to the section 4.5 "Check code" for a BCC calculation.
Delimiter CR (0Dh): End of Message
31h,
37h): Model Name command
Check code
BCC: Block Check Code Refer to ASCII characters strings.
(30/40) Note.) The maximum data length that can be returned from the monitor at a time is 32bytes.
N-N: Message length Note.) The...
LCD4020/4620/5220/6520, M40/M46 external control commands - Page 31
... want to change a setting.
ETX (03h): End of Message
Check code BCC: Block Check Code Refer to the section 4.5 "Check code" for Pass codes inputs, then it only checks Pass cords (and releases image muting if Pass codes are matched with them then setting isn't changed, and reply error status and a current condition. If the monitor receives this command is...
LCD4020/4620/5220/6520, M40/M46 external control commands - Page 33
...
Color Temperature
00h
Color control
00h
PICTURE
Gamma Selection
02h
Adaptive Contrast
02h
Movie
Noise
02h
Settings Reduction
Film Mode
02h
Menu tree reset
02h
(Picture)
Auto Setup
00h
Auto Adjust
H Position
00h
V Position
00h
ADJUST
OP code
Parameter
10h 12h 8Ch
92h 90h 1Fh 54h Red: 9Bh Yellow: 9Ch Green: 9Dh Cyan...
SB-L007KK brochure - Page 1
... large-screen LCD displays, this expansion board provides an SD/HD SDI input and loopthrough, and comes standard with the NEC SB-L007KK, an internal card that provides an HD-SDI input without using additional space or power.
NEC Displays Supported
NEC M Series 40" M40-AV 40" M40B-AV 46" M46-AV 46" M46B-AV
NEC MultiSync 20 Series 40" LCD4020-AV 40" LCD4020...
SB-L008WU accessory brochure - Page 1
... back-to -back installations. Further reduces installation costs
NEC Displays Supported
NEC M Series 40" M40-AV 40" M40-2-AV 40" M40B-AV 46" M46-AV 46" M46-2-AV 46" M46B-AV
NEC MultiSync® 20 Series 40" LCD4020-2-AV 46" LCD4620-2-AV 52" LCD5220-AV 65" LCD6520L-BK-AV 65" LCD6520P-BK-AV
Input Signal (DVI - Gives users a fast and easy way to nine displays. Product specifications subject to...
M Series color brochure - Page 1
...
40" and 46" full high-definition LCDs
Designer piece, entertainer and sales professional - A strong presence for video and broadcast applications ¤ Built-in flagship stores and designer shops. The M Series fascinates in all kinds on -AVT units only ¤ Available speakers and wall mount enhance the visual experience ¤ Environmental friendliness (RoHS-compliant, low...
M Series color brochure - Page 2
... 3000:1
M46-2 (-AV, -AVT) / M46B (-AV, -AVT) 46"
0.53mm 40.1 x 22.5 in. / 1018.1 x 572.7mm
DVI-D 24 pin (HDCP) 15-pin D-sub
5 BNC (RGBHV) Composite (Shared RCA and BNC)
S-Video HDMI Component BNC (Y,Cb/Pb, Cr/Pr) RCA (L/R) x 2: Stereo MiniJack + external speaker jacks
M40-2-AVT, M40B-AVT
Yes Yes Yes 15W Stereo RS-232 for M40/M46
MODE L
LCD MODULE Viewable...