FTOS Command Line Reference Guide for the S4810 System FTOS 9.1.(0.0)
Page 404
...network backdoor config on a learned route. redistribute Redistribute routes into BGP. Parameters connected static Enter the keyword connected to redistribute manually configured routes. Not configured. These routes are supported: • match ip address • set community • set ...to the backdoor config, there is an option for example, /24). Introduced on the C-Series. Introduced on the S4810. C-Series, E-Series, S-Series, Z-Series, S4810 Syntax redistribute {connected | static} [route-map map-name] To disable redistribution, use the no redistribution {connected ...
...network backdoor config on a learned route. redistribute Redistribute routes into BGP. Parameters connected static Enter the keyword connected to redistribute manually configured routes. Not configured. These routes are supported: • match ip address • set community • set ...to the backdoor config, there is an option for example, /24). Introduced on the C-Series. Introduced on the S4810. C-Series, E-Series, S-Series, Z-Series, S4810 Syntax redistribute {connected | static} [route-map map-name] To disable redistribution, use the no redistribution {connected ...
FTOS Command Line Reference Guide for the S4810 System FTOS 9.1.(0.0)
Page 624
...Enabled PROTOCOL LLDP Version 8.3.12.0 Version 8.3.16.0 Introduced on MXL 10/40GbE Switch IO Module. The interface configuration takes priority over global configuration. S4810 Syntax advertise dcbx-appln-tlv {fcoe | iscsi} To remove the application priority TLVs, use the no advertise dcbx-appln-tlv {fcoe | ... PROTOCOL LLDP 624 Introduced on the S4810. Usage Information You can configure iSCSI TLVs to send either globally or on the interface to send iSCSI TLV advertisements. advertise dcbx-appln-tlv On a DCBX port with a manual role, configure the application priority TLVs...
...Enabled PROTOCOL LLDP Version 8.3.12.0 Version 8.3.16.0 Introduced on MXL 10/40GbE Switch IO Module. The interface configuration takes priority over global configuration. S4810 Syntax advertise dcbx-appln-tlv {fcoe | iscsi} To remove the application priority TLVs, use the no advertise dcbx-appln-tlv {fcoe | ... PROTOCOL LLDP 624 Introduced on the S4810. Usage Information You can configure iSCSI TLVs to send either globally or on the interface to send iSCSI TLV advertisements. advertise dcbx-appln-tlv On a DCBX port with a manual role, configure the application priority TLVs...
FTOS Command Line Reference Guide for the S4810 System FTOS 9.1.(0.0)
Page 625
...You can configure the transmission of the command; Configure DCBX operation at a time; advertise dcbx-tlv On a DCBX port with a manual role, configure the PFC and ETS TLVs advertised to peers. S4810 Syntax advertise dcbx-tlv {ets-conf | ets-reco | pfc} [ets-conf | etsreco | pfc] [ets-conf | ets-...for example, no advertise dcbx-tlv pfc ets-reco. for example: advertise dcbx-tlv ets-conf ets-reco. To verify the DCBX configuration on the S4810. Parameters {ets-conf | etsreco | pfc} Enter the PFC and ETS TLVs advertised, where: • ets-conf: enables the advertisement of ETS...
...You can configure the transmission of the command; Configure DCBX operation at a time; advertise dcbx-tlv On a DCBX port with a manual role, configure the PFC and ETS TLVs advertised to peers. S4810 Syntax advertise dcbx-tlv {ets-conf | ets-reco | pfc} [ets-conf | etsreco | pfc] [ets-conf | ets-...for example, no advertise dcbx-tlv pfc ets-reco. for example: advertise dcbx-tlv ets-conf ets-reco. To verify the DCBX configuration on the S4810. Parameters {ets-conf | etsreco | pfc} Enter the PFC and ETS TLVs advertised, where: • ets-conf: enables the advertisement of ETS...
FTOS Command Line Reference Guide for the S4810 System FTOS 9.1.(0.0)
Page 626
...on a port, use the dcbx version {auto | cee | cin | ieeev2.5} command. 626 dcbx version Configure the DCBX version used on the S4810. S4810 Syntax dcbx version {auto | cee | cin | ieee-v2.5} To remove the DCBX version, use the show interface dcbx detail command. The ...peer or a local configuration source. DCBX requires that you enable LLDP to advertise DCBX TLVs to receive a peer configuration. S4810 Syntax dcbx port-role {config-source | auto-downstream | auto-upstream | manual} To remove DCBX port role, use the no dcbx port-role {config-source | autodownstream | auto-upstream...
...on a port, use the dcbx version {auto | cee | cin | ieeev2.5} command. 626 dcbx version Configure the DCBX version used on the S4810. S4810 Syntax dcbx version {auto | cee | cin | ieee-v2.5} To remove the DCBX version, use the show interface dcbx detail command. The ...peer or a local configuration source. DCBX requires that you enable LLDP to advertise DCBX TLVs to receive a peer configuration. S4810 Syntax dcbx port-role {config-source | auto-downstream | auto-upstream | manual} To remove DCBX port role, use the no dcbx port-role {config-source | autodownstream | auto-upstream...
FTOS Command Line Reference Guide for the S4810 System FTOS 9.1.(0.0)
Page 629
...to use the clear dcbx counters interface stackunit/port command. In auto-upstream mode, a port can only receive a DCBX version supported on the S4810. Transmission status (enabled or disabled) of advertised DCB TLVs (see TLV code at the top of PFC and ETS operational status. Command Modes ... interface dcbx detail command shown in the Example below. Configured the DCBX port role: auto-upstream, auto-downstream, config-source, or manual. The DCBX operational status is the combination of the show command output). DCBX version accepted in Control TLVs. 629 DCBX version that the...
...to use the clear dcbx counters interface stackunit/port command. In auto-upstream mode, a port can only receive a DCBX version supported on the S4810. Transmission status (enabled or disabled) of advertised DCB TLVs (see TLV code at the top of PFC and ETS operational status. Command Modes ... interface dcbx detail command shown in the Example below. Configured the DCBX port role: auto-upstream, auto-downstream, config-source, or manual. The DCBX operational status is the combination of the show command output). DCBX version accepted in Control TLVs. 629 DCBX version that the...
FTOS Command Line Reference Guide for the S4810 System FTOS 9.1.(0.0)
Page 656
...of addresses to be excluded from the pool. Enter the highest address in a range of the client. hardware-address For manual configurations, specify the client hardware address. Defaults Command Modes Command History none DHCP Version 8.3.11.1 Version 8.3.7.0 Version 8.2.1.0 Introduced... on the C-Series and S-Series. Introduced on the S4810. C-Series, S-Series, Z-Series, S4810 Syntax Parameters excluded-address [address | low-address high-address] address low-address high-address Enter a single address ...
...of addresses to be excluded from the pool. Enter the highest address in a range of the client. hardware-address For manual configurations, specify the client hardware address. Defaults Command Modes Command History none DHCP Version 8.3.11.1 Version 8.3.7.0 Version 8.2.1.0 Introduced... on the C-Series and S-Series. Introduced on the S4810. C-Series, S-Series, Z-Series, S4810 Syntax Parameters excluded-address [address | low-address high-address] address low-address high-address Enter a single address ...
FTOS Command Line Reference Guide for the S4810 System FTOS 9.1.(0.0)
Page 657
...Introduced on the Z9000. Enter the number of hours of the lease. Specify that the lease never expires. Introduced on the Z9000. host For manual (rather than automatic) configurations, assign a host to 31. lease Specify a lease time for the addresses in a pool. Defaults Command Modes ...Command History 24 hours DHCP Version 8.3.11.1 Version 8.3.7.0 Version 8.2.1.0 Introduced on the S4810. The range is 0 to 23. Introduced on the C-Series and S-Series. The range is 0 to 59. C-Series, S-Series, Z-Series...
...Introduced on the Z9000. Enter the number of hours of the lease. Specify that the lease never expires. Introduced on the Z9000. host For manual (rather than automatic) configurations, assign a host to 31. lease Specify a lease time for the addresses in a pool. Defaults Command Modes ...Command History 24 hours DHCP Version 8.3.11.1 Version 8.3.7.0 Version 8.2.1.0 Introduced on the S4810. The range is 0 to 23. Introduced on the C-Series and S-Series. The range is 0 to 59. C-Series, S-Series, Z-Series...
FTOS Command Line Reference Guide for the S4810 System FTOS 9.1.(0.0)
Page 713
... bridged LAN maintain the same VLAN registration information. If a local bridge needs to classify and analyze packets by GVRP include both manually configured local static entries and dynamic entries from GVRP-enabled devices, GVRP allows the system to dynamically create a port-based VLAN ...or de-registers its attributes with GVRP exist only as long as a GVRP-enabled device is rebooted, all Dell Force10 C-Series, E-Series, S-Series, Z-Series, and S4810 platforms. The generic attribute registration protocol (GARP) mechanism allows the configuration of a GARP participant to propagate through...
... bridged LAN maintain the same VLAN registration information. If a local bridge needs to classify and analyze packets by GVRP include both manually configured local static entries and dynamic entries from GVRP-enabled devices, GVRP allows the system to dynamically create a port-based VLAN ...or de-registers its attributes with GVRP exist only as long as a GVRP-enabled device is rebooted, all Dell Force10 C-Series, E-Series, S-Series, Z-Series, and S4810 platforms. The generic attribute registration protocol (GARP) mechanism allows the configuration of a GARP participant to propagate through...
FTOS Command Line Reference Guide for the S4810 System FTOS 9.1.(0.0)
Page 714
...local bridge needs to know only how to reach a given VLAN, then GVRP provides all VLANs that are statically configured. C-Series, E-Series, S-Series, Z-Series, S4810 Syntax Parameters clear gvrp statistics interface interface interface interface Enter the following keywords and slot/port or number information: • For a Fast Ethernet interface, enter... necessary information. • The VLAN topologies that GVRP learns are saved in NVRAM, while static updates are treated differently from VLANs that were manually configured. The GVRP dynamic updates are not saved in NVRAM.
...local bridge needs to know only how to reach a given VLAN, then GVRP provides all VLANs that are statically configured. C-Series, E-Series, S-Series, Z-Series, S4810 Syntax Parameters clear gvrp statistics interface interface interface interface Enter the following keywords and slot/port or number information: • For a Fast Ethernet interface, enter... necessary information. • The VLAN topologies that GVRP learns are saved in NVRAM, while static updates are treated differently from VLANs that were manually configured. The GVRP dynamic updates are not saved in NVRAM.
FTOS Command Line Reference Guide for the S4810 System FTOS 9.1.(0.0)
Page 726
...the period parameter. Default Command Modes Command History By default, a process can be restartable. Introduced on the S4810. This command does not affect user-initiated (manual) failovers. The default is 60 minutes. The default is 3. On the exception that exceeds the limit, the... system reloads (for systems with dual RPMs). C-Series, E-Series, S4810 Syntax Parameters redundancy auto-failover-limit [count number [period ...
...the period parameter. Default Command Modes Command History By default, a process can be restartable. Introduced on the S4810. This command does not affect user-initiated (manual) failovers. The default is 60 minutes. The default is 3. On the exception that exceeds the limit, the... system reloads (for systems with dual RPMs). C-Series, E-Series, S4810 Syntax Parameters redundancy auto-failover-limit [count number [period ...
FTOS Command Line Reference Guide for the S4810 System FTOS 9.1.(0.0)
Page 732
C-Series, E-Series, S4810 Syntax Parameters redundancy synchronize [full | persistent-data | system-data] full persistent-data system-data Enter the keyword full to synchronize persistent-data ...C-Series. EXEC Privilege Version 8.3.12.0 Version 8.1.1.0 Version 7.5.1.0 Version 7.6.1.0 Introduced on the E-Series. redundancy synchronize Manually synchronize data once between RPMs. Enter the keywords system-data to synchronize all data. Introduced on the S4810. Related Commands 0 active 1 active • show patch EXEC 732 displays the switch fabric backplane or internal ...
C-Series, E-Series, S4810 Syntax Parameters redundancy synchronize [full | persistent-data | system-data] full persistent-data system-data Enter the keyword full to synchronize persistent-data ...C-Series. EXEC Privilege Version 8.3.12.0 Version 8.1.1.0 Version 7.5.1.0 Version 7.6.1.0 Introduced on the E-Series. redundancy synchronize Manually synchronize data once between RPMs. Enter the keywords system-data to synchronize all data. Introduced on the S4810. Related Commands 0 active 1 active • show patch EXEC 732 displays the switch fabric backplane or internal ...
FTOS Command Line Reference Guide for the S4810 System FTOS 9.1.(0.0)
Page 739
...8226; IGMPv3 router interoperability with IGMPv3. clear ip igmp groups Clear entries from the group cache table. Important Points to manually set the IGMP version. • All commands previously used for IGMPv2 are supported by the slot/port information. 739...S4810 platforms. This chapter contains the following keywords and slot/port or number information: • For an 100/1000 Base-T Ethernet interface, enter the keyword gigabitethernet followed by the slot/port information. • For a 1-Gigabit Ethernet interface, enter the keyword gigabitethernet followed by the Dell Force10...
...8226; IGMPv3 router interoperability with IGMPv3. clear ip igmp groups Clear entries from the group cache table. Important Points to manually set the IGMP version. • All commands previously used for IGMPv2 are supported by the slot/port information. 739...S4810 platforms. This chapter contains the following keywords and slot/port or number information: • For an 100/1000 Base-T Ethernet interface, enter the keyword gigabitethernet followed by the slot/port information. • For a 1-Gigabit Ethernet interface, enter the keyword gigabitethernet followed by the Dell Force10...
FTOS Command Line Reference Guide for the S4810 System FTOS 9.1.(0.0)
Page 747
... For a SONET interface, enter the keyword sonet followed by a number. For the E-Series, the range is 1 to 128. Introduced on the S4810. For the C-Series and SSeries, the range is 1 to 255 for TeraScale and 1 to 512 for ExaScale. • For a Loopback interface...the Z9000. Introduced on the E-Series. Introduced on the C-Series. C-Series, E-Series, S-Series, Z-Series, S4810 Syntax Parameters show ip igmp groups View the IGMP groups. ip igmp version Manually set the IGMP version number to IGMPv2 or IGMPv3. Defaults Command Modes Command History 2 (that group only. (...
... For a SONET interface, enter the keyword sonet followed by a number. For the E-Series, the range is 1 to 128. Introduced on the S4810. For the C-Series and SSeries, the range is 1 to 255 for TeraScale and 1 to 512 for ExaScale. • For a Loopback interface...the Z9000. Introduced on the E-Series. Introduced on the C-Series. C-Series, E-Series, S-Series, Z-Series, S4810 Syntax Parameters show ip igmp groups View the IGMP groups. ip igmp version Manually set the IGMP version number to IGMPv2 or IGMPv3. Defaults Command Modes Command History 2 (that group only. (...
FTOS Command Line Reference Guide for the S4810 System FTOS 9.1.(0.0)
Page 764
...interface. Introduced on the S-Series. configures a static route that points to 10/100. S-Series, Z-Series, S4810 Syntax duplex {half | full} To return to transmit only in both directions. Defaults Command Modes Command History Not configured. Introduced ...no duplex command. INTERFACE Version 8.3.11.1 Version 8.3.7.0 Version 8.1.1.0 Version 7.6.1.0 Version 7.5.1.0 Version 6.4.1.0 Introduced on the C-Series. When you can manually set to the Management interface on the Base-T Ethernet interface. duplex (Management) - Enter the keyword full to set the physical interface to...
...interface. Introduced on the S-Series. configures a static route that points to 10/100. S-Series, Z-Series, S4810 Syntax duplex {half | full} To return to transmit only in both directions. Defaults Command Modes Command History Not configured. Introduced ...no duplex command. INTERFACE Version 8.3.11.1 Version 8.3.7.0 Version 8.1.1.0 Version 7.6.1.0 Version 7.5.1.0 Version 6.4.1.0 Introduced on the C-Series. When you can manually set to the Management interface on the Base-T Ethernet interface. duplex (Management) - Enter the keyword full to set the physical interface to...
FTOS Command Line Reference Guide for the S4810 System FTOS 9.1.(0.0)
Page 783
.../1000 Base-T Ethernet line cards. NOTE: The mode option is configured as forced-slave. If you enable auto-negotiation. If you first manually set the speed of the following: • Forced-master • Force-slave • Master • Slave • Auto-neg...The no negotiation auto command is only available if you do not use the no negotiation auto command. negotiation auto Enable auto-negotiation on the S4810. INTERFACE Version 8.3.11.1 Version 8.3.7.0 Version 8.1.1.0 Version 7.6.1.0 Version 7.5.1.0 pre-Version 6.2.1.0 Introduced on a port, the port negotiates to 10Mbits or...
.../1000 Base-T Ethernet line cards. NOTE: The mode option is configured as forced-slave. If you enable auto-negotiation. If you first manually set the speed of the following: • Forced-master • Force-slave • Master • Slave • Auto-neg...The no negotiation auto command is only available if you do not use the no negotiation auto command. negotiation auto Enable auto-negotiation on the S4810. INTERFACE Version 8.3.11.1 Version 8.3.7.0 Version 8.1.1.0 Version 7.6.1.0 Version 7.5.1.0 pre-Version 6.2.1.0 Introduced on a port, the port negotiates to 10Mbits or...
FTOS Command Line Reference Guide for the S4810 System FTOS 9.1.(0.0)
Page 815
... configures the Management port on the system (either enabled or disabled. When you set the speed to 10 or 100 Mbps, you can manually set the interface to 10/100. 815 configures duplex mode on physical interfaces with the speed set to auto-negotiate its speed with catalog ... FTOS version 7.8.1.0, when you use a copper SFP2 module with the speed command. duplex (10/100 Interfaces) - Introduced on the S55, S60, and S4810 Introduced on the Management interface only. Both sides of 1000 or auto, the software sets the link to 10 Mb/s. Related Commands When you configure...
... configures the Management port on the system (either enabled or disabled. When you set the speed to 10 or 100 Mbps, you can manually set the interface to 10/100. 815 configures duplex mode on physical interfaces with the speed set to auto-negotiate its speed with catalog ... FTOS version 7.8.1.0, when you use a copper SFP2 module with the speed command. duplex (10/100 Interfaces) - Introduced on the S55, S60, and S4810 Introduced on the Management interface only. Both sides of 1000 or auto, the software sets the link to 10 Mb/s. Related Commands When you configure...
FTOS Command Line Reference Guide for the S4810 System FTOS 9.1.(0.0)
Page 819
... • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE followed by stack members. Introduced on the E-Series. Introduced on the S4810. Use the interface port-channel command to the FTOS Configuration Guide. Defaults Command Modes Command History Usage Information Not configured. Introduced on the E-.... NOTE: The FTOS implementation of LAG or Port Channel requires that you configure a LAG on the S-Series. Introduced on both switches manually. Because each port can be assigned to only one Port Channel, and each Port Channel must have at least one port, some of...
... • For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE followed by stack members. Introduced on the E-Series. Introduced on the S4810. Use the interface port-channel command to the FTOS Configuration Guide. Defaults Command Modes Command History Usage Information Not configured. Introduced on the E-.... NOTE: The FTOS implementation of LAG or Port Channel requires that you configure a LAG on the S-Series. Introduced on both switches manually. Because each port can be assigned to only one Port Channel, and each Port Channel must have at least one port, some of...
FTOS Command Line Reference Guide for the S4810 System FTOS 9.1.(0.0)
Page 870
... vlan followed by a number from 1 to display local ARP entries learned from private VLANs (PVLANs). Introduced on the S-Series. Introduced on the S4810. The following describes the show arp command shown in minutes) of the ARP entry. The Example below . Row Heading Protocol Address Age(min) ...Added support for the C-Series and S-Series in nn:nn:nn:nn:nn format also. (OPTIONAL) Enter the keyword static to view entries entered manually. (OPTIONAL) Enter the keyword dynamic to view dynamic entries. (OPTIONAL) Enter the keyword summary to Private VLAN (PVLAN)), a feature added for 4094...
... vlan followed by a number from 1 to display local ARP entries learned from private VLANs (PVLANs). Introduced on the S-Series. Introduced on the S4810. The following describes the show arp command shown in minutes) of the ARP entry. The Example below . Row Heading Protocol Address Age(min) ...Added support for the C-Series and S-Series in nn:nn:nn:nn:nn format also. (OPTIONAL) Enter the keyword static to view entries entered manually. (OPTIONAL) Enter the keyword dynamic to view dynamic entries. (OPTIONAL) Enter the keyword summary to Private VLAN (PVLAN)), a feature added for 4094...
FTOS Command Line Reference Guide for the S4810 System FTOS 9.1.(0.0)
Page 886
... 1/6 down down unassigned unassigned up unassigned up unassigned up 10.10.10.1 up unassigned NO Manual YES Manual YES Manual YES Manual YES Manual NO Manual administratively administratively show ip management-route View the IP addresses assigned to view non-active routes also.... C-Series, E-Series, Z-Series, S4810 Syntax Parameters show ip management-route Destination Gateway State 886 Introduced on the S4810...
... 1/6 down down unassigned unassigned up unassigned up unassigned up 10.10.10.1 up unassigned NO Manual YES Manual YES Manual YES Manual YES Manual NO Manual administratively administratively show ip management-route View the IP addresses assigned to view non-active routes also.... C-Series, E-Series, Z-Series, S4810 Syntax Parameters show ip management-route Destination Gateway State 886 Introduced on the S4810...
FTOS Command Line Reference Guide for the S4810 System FTOS 9.1.(0.0)
Page 901
...• IPv6 Route Map Commands NOTE: For IPv4 ACL commands, refer to support IPv6 ACLs. • C-Series and S-Series platforms require manual CAM usage space allotment. Important Points to Remember • E-Series platforms require IPv6-ExtACL content addressable memory (CAM) profile to the Access ... apply both IPv4 and IPv6 ACLs on an interface at the same time. • You can apply IPv6 ACLs on Dell Force10 E-Series, C-Series, S-Series S4810. C-Series, E-Series, S-Series, S4810 Syntax cam-acl {default | l2acl 1-10 ipv4acl 1-10 ipv6acl 0-10 ipv4qos 1-10 l2qos 1-10} 901 For more...
...• IPv6 Route Map Commands NOTE: For IPv4 ACL commands, refer to support IPv6 ACLs. • C-Series and S-Series platforms require manual CAM usage space allotment. Important Points to Remember • E-Series platforms require IPv6-ExtACL content addressable memory (CAM) profile to the Access ... apply both IPv4 and IPv6 ACLs on an interface at the same time. • You can apply IPv6 ACLs on Dell Force10 E-Series, C-Series, S-Series S4810. C-Series, E-Series, S-Series, S4810 Syntax cam-acl {default | l2acl 1-10 ipv4acl 1-10 ipv6acl 0-10 ipv4qos 1-10 l2qos 1-10} 901 For more...