Service Guide - Page 79

...) The Main Screen is the first screen that setup is entered, unless an error has occurred. If an error has occurred, the Error Manager Screen appears instead. Platform ID Option Values: Help Text: < Platform ID> Intel® Server System R1000RP Service Guide 67 Main Screen Screen Field Descriptions: 1. With no passwords set, Administrator is the default mode. Back to [Main...
Service Guide - Page 11

... 108 Figure 98. Removing the Bracket with Power Distribution Board from Chassis 35 Figure 53. Installing 8x3.5" Hot-swap Backplane 46 Figure 71. Advanced Screen...61 Figure 86. Mass Storage Controller Configuration Screen 75 Figure 89. BMC LAN Configuration Screen 111 Intel® Server System P4000RP Family Service Guide xi List of Figures Figure 48. Loosening the Bracket...
Service Guide - Page 71

Displays password level that appears when the BIOS Setup configuration utility is executing POST. 58 Intel® Server System P4000RP Family Service Guide Server Utilities Main Screen (Tab) The Main Screen is the first screen that setup is the default mode. If an error has occurred, the Error Manager Screen appears instead Main Advanced Security Server Management Boot Options Logged in...
Service Guide - Page 116

... timer expires. [Reset] - Intel® Server System P4000RP Family Service Guide 103 OS Boot Watchdog Timer Policy Option Values: Power off repeatedly. System powers off. This option is the timeout value BIOS will set the BMC Watchdog to detect an apparent hang during OS boot. Unless the OS does have the correct IPMI driver software loaded. Comments: Timer...
Technical Product Specification - Page 35

... set of the Intel® C220 series chipset. Revision 1.0 23 Intel® Server Board S1200V3RP Functional Architecture requires appropriate software support (for example, an AHCI driver) and for details on LSI* MegaRAID Software Stack  Software RAID with system providing memory and CPU utilization  Supported RAID Levels - 0, 1, 10, RAID 5 support provides with upgrade...
Technical Product Specification - Page 37

...802.3 Ethernet interface for server and client configurations as defined in a ...Control (MAC) and Physical Layer (PHY) port. Intel® Server Board S1200V3RP Functional Architecture 3.4.6.3 eUSB SSD Support The server board provides support for Boot capability 3.4.7 Gigabit Ethernet Controller Network connectivity is provided by means of two onboard Intel® Ethernet Controller...
Technical Product Specification - Page 62

... Data Records (SDRs) so that are configured by BIOS MRC remain fixed after post. Platform Management Functional Overview Intel® Server Board S1200V3RP Type Profile Details OLTT 7 Performance, 3000M altitude CLTT 0 300M altitude CLTT 2 900M altitude CLTT 4 1500M altitude CLTT 6 3000M altitude Each group of profiles allows for varying fan control policies based on each...
Technical Product Specification - Page 65

Intel® Server Board S1200V3RP Platform Management Functional Overview The baseboard NICs are connected to a single BMC RMII/RGMII port that uses the RGMII interface to link with RMII. The logical layer (configuration commands) is hidden from the OS. 6.11.3.2.3 Concurrent Server Management Use of these baseboard ports to be on different subnets for RMII operation. Therefore...
Technical Product Specification - Page 88

...76 Revision 1.0 Note: This connector is not compatible with the previous generation Intel® Remote Management Modules (Intel® RMM/RMM2/RMM3) Table 29. CPU Power Connector Pin-out (J9B1) Pin Signal 1 GND of Pin 5 .../black Table 28. This server board does not support third-party management cards. On-board Connector/Header Overview Intel® Server Board S1200V3RP Table 27.
Technical Product Specification - Page 259

... erasable programmable read-only memory Emergency management port External Product Specification Fast management link Fast management link network interface Fault resilient booting Field replaceable unit Front side bus Firmware transfer mode General-purpose input/output Hot-swap backplane Hot-swap controller Instruction cache. Intel® Server Board S1200V3RP Glossary Glossary This appendix...
Technical Product Specification - Page 59

... the IP is configured using DHCP or Static, IP Address, Subnet Mask, and Gateway. ^ | DHCP (or Static) | IP Address: xxx.xxx.xxx.xxx | Subnet Mask: xxx.xxx.xxx.xxx | Gateway: xxx.xxx.xxx.xxx Figure 45. This applies to the previous screen by BIOS. Intel® Server System R1000RP Family TPS Intel® Local Control Panel This is...
Technical Product Specification - Page 61

Intel® Server System R1000RP Family TPS Intel® Local Control Panel ^ | IP Source | IP Address | Subnet | Gateway Figure 51. If the user selects Static or if the existing setting... to be selected to the following menu, the firmware sets the BMC IP source as 000.000.000.000...positions within the same item. 2. Screen Shot for Configuring IP Address, Subnet Mask, and Gateway By default, ...
Technical Product Specification - Page 63

... last BIOS post code.  Custom string: Displays a customizable text string. The power consumed will not display an informational message. Intel® Server System R1000RP Family TPS Intel® Local Control Panel ^ | Server Name | Server Model | Error | BMC IP | RMM4 IP | Power | Last PC | Custom String | Custom Logo Figure 56. If the system is modifiable through BIOS setup...
Technical Product Specification - Page 67

... system BIOS, FRUSDR, BMC firmware, and hot-swap controller firmware. Appendix A: Integration and Usage Tips Intel® Server System R1000RP Family TPS Appendix A: Integration and Usage Tips Before attempting to integrate and configure your system, you must populate all hard drive bays with processors, memory, and peripheral devices, the FRUSDR utility must be downloaded from accurately...
Technical Product Specification - Page 73

...codes in the BIOS setup determines whether the system pauses to the SEL with the error code. POST Error Message and Handling Error Code 0012 0048 0140 0141 Error Message System RTC date/time not set Password check failed PCI component encountered a PERR error PCI resource conflict Response Major Major Major Major Revision 1.2 Intel order number: G91532-003 63 These codes represent specific...

Intel S1200RP Reviews

Do you have an experience with the Intel S1200RP that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Intel yet.

Popular Intel S1200RP Search Terms

The following terms are frequently used to search for Intel S1200RP support:

Ask a New Question
Use the box below to post a new question about Intel S1200RP.
Manuals / Documents
Download any of our Intel S1200RP manuals for free!

We have the following 4 documents available for the Intel S1200RP:
  • Technical Product Specification
  • Service Guide
  • Service Guide
  • Technical Product Specification

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Intel Manuals

Find free Intel S1200RP manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Intel Reviews

View thousands of Intel S1200RP user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Intel customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Intel customer service rankings, employee comments and much more from our sister site.