Dell PowerEdge R430 Owners Manual
Page 1
... part number Components chosen as microprocessors, remote access controllers, and storage controllers) is available by component separately. Volatile components lose their data even after the power has been removed from the component. Varies by part number Dell - Internal Use - The following NV components are not included in the PowerEdge R430 server. Item Planer PCH Internal CMOS RAM BIOS Password BIOS SPI Flash iDRAC SPI Flash BMC EMMC System CPLD RAM System Memory Internal USB Key CPU iDRAC DDR iDRAC LOM EEPROM Power Supplies...
... part number Components chosen as microprocessors, remote access controllers, and storage controllers) is available by component separately. Volatile components lose their data even after the power has been removed from the component. Varies by part number Dell - Internal Use - The following NV components are not included in the PowerEdge R430 server. Item Planer PCH Internal CMOS RAM BIOS Password BIOS SPI Flash iDRAC SPI Flash BMC EMMC System CPLD RAM System Memory Internal USB Key CPU iDRAC DDR iDRAC LOM EEPROM Power Supplies...
Dell PowerEdge R430 Owners Manual
Page 3
Internal Use - Confidential Can user programs or operating system write data to change BIOS settings No Boot code, system configuration information, UEFI environment, Flash Disceptor, ME No iDRAC Uboot (bootloader), server managent persistent store (i.e. boot code) No Real-time clock and BIOS configuration settings Yes Password to it during normal operation? Purpose? (e.g. Flash PROM, EEPROM) Planer PCH Internal CMOS RAM Battery-backed CMOS RAM BIOS Password Battery-backed CMOS RAM BIOS SPI Flash SPI Flash iDRAC SPI Flash SPI Flash Dell - IDRAC MAC ...
Internal Use - Confidential Can user programs or operating system write data to change BIOS settings No Boot code, system configuration information, UEFI environment, Flash Disceptor, ME No iDRAC Uboot (bootloader), server managent persistent store (i.e. boot code) No Real-time clock and BIOS configuration settings Yes Password to it during normal operation? Purpose? (e.g. Flash PROM, EEPROM) Planer PCH Internal CMOS RAM Battery-backed CMOS RAM BIOS Password Battery-backed CMOS RAM BIOS SPI Flash SPI Flash iDRAC SPI Flash SPI Flash Dell - IDRAC MAC ...
Dell PowerEdge R430 Owners Manual
Page 4
... Controller (LC) USC partition, LC service diags, LC OS drivers, USC firmware No Not utilized Yes System OS RAM Yes General purpose USB key drive Yes Processor cache + registers No iDRAC local memory No Processor cache + registers No Onboard LOM FW No Power Supply operation, power management data and fault behaviors No Firmware + FRU No Configuration data No Card manufacturing information Dell - Internal Use - Confidential Flash PROM, EEPROM) BMC EMMC eMMC NAND Flash System CPLD RAM System Memory Internal USB Key CPU iDRAC...
... Controller (LC) USC partition, LC service diags, LC OS drivers, USC firmware No Not utilized Yes System OS RAM Yes General purpose USB key drive Yes Processor cache + registers No iDRAC local memory No Processor cache + registers No Onboard LOM FW No Power Supply operation, power management data and fault behaviors No Firmware + FRU No Configuration data No Card manufacturing information Dell - Internal Use - Confidential Flash PROM, EEPROM) BMC EMMC eMMC NAND Flash System CPLD RAM System Memory Internal USB Key CPU iDRAC...
Dell PowerEdge R430 Owners Manual
Page 5
... 1-Wire EEPROM SBR Flash Type (e.g. boot code) No Holds default controller properties/settings No Bootloader No Card firmware NVSRAM FRU 1-Wire EEPROM SPD SBR Flash ONFI Backup Flash SDRAM No Configuration data No Card manufacturing information No Holds default controller properties/settings No Memory configuration data No Bootloader No Card firmware No Holds cache data during normal operation? Flash PROM, EEPROM) 1-Wire EEPROM SBR Flash Can user programs or operating system write data to it during power loss No Cache...
... 1-Wire EEPROM SBR Flash Type (e.g. boot code) No Holds default controller properties/settings No Bootloader No Card firmware NVSRAM FRU 1-Wire EEPROM SPD SBR Flash ONFI Backup Flash SDRAM No Configuration data No Card manufacturing information No Holds default controller properties/settings No Memory configuration data No Bootloader No Card firmware No Holds cache data during normal operation? Flash PROM, EEPROM) 1-Wire EEPROM SBR Flash Can user programs or operating system write data to it during power loss No Cache...
Dell PowerEdge R430 Owners Manual
Page 6
... boot code) No Exclusively used by the controller Yes Firmware Yes Storage of encryption keys Item How is data input to this How is this memory How is not functional if corrupted/removed. Planar PCH Internal BIOS CMOS RAM N/A - BIOS Password Keyboard N/A Place shunt on ; 3) restore default configuration in Lifecycle Controller interface Dell - however, user data, lifecycle log and archive, SEL, fw image repository can be cleared via Delete Configuration and Retire System, accessible in Lifecycle Controller interface BMC...
... boot code) No Exclusively used by the controller Yes Firmware Yes Storage of encryption keys Item How is data input to this How is this memory How is not functional if corrupted/removed. Planar PCH Internal BIOS CMOS RAM N/A - BIOS Password Keyboard N/A Place shunt on ; 3) restore default configuration in Lifecycle Controller interface Dell - however, user data, lifecycle log and archive, SEL, fw image repository can be cleared via Delete Configuration and Retire System, accessible in Lifecycle Controller interface BMC...
Dell PowerEdge R430 Owners Manual
Page 7
... Flash Pre-programmed before Not WP. Internal Use - Not visible to Cannot be cleared with existing tools assembly. System CPLD RAM Not utilized Not accessible System Memory System OS OS Control Internal USB Key USB interface via iDRAC Hardware strapping Power Supplies PSU FW Different vendors have NA different utilities and tools to load the data to memory. Not visible to the customer Dell - Accessed via system OS No write protect CPU...
... Flash Pre-programmed before Not WP. Internal Use - Not visible to Cannot be cleared with existing tools assembly. System CPLD RAM Not utilized Not accessible System Memory System OS OS Control Internal USB Key USB interface via iDRAC Hardware strapping Power Supplies PSU FW Different vendors have NA different utilities and tools to load the data to memory. Not visible to the customer Dell - Accessed via system OS No write protect CPU...
Dell PowerEdge R430 Owners Manual
Page 8
... PERCs NVSRAM ROC writes configuration Not WP. using Dell/LSI tools Not WP. Confidential Can be cleared by powering up DDR data to HDDs Not WP. using Dell/LSI tools Not WP. Not visible to Host Processor Cannot be cleared with existing tools available to the customer ONFI Backup Flash FPGA backs up the card and allowing the controller to flush the contents...
... PERCs NVSRAM ROC writes configuration Not WP. using Dell/LSI tools Not WP. Confidential Can be cleared by powering up DDR data to HDDs Not WP. using Dell/LSI tools Not WP. Not visible to Host Processor Cannot be cleared with existing tools available to the customer ONFI Backup Flash FPGA backs up the card and allowing the controller to flush the contents...
Dell PowerEdge R430 Owners Manual
Page 9
... Dell Inc. Trademarks used in this text: Dell™, the DELL logo, and PowerEdge™ are trademarks of Volatility for the individual components. IDSDM SPI Flash SPI interface via iDRAC Hardware strapping MCU USB3.0 interface via PCH, N/A FW can be updated via iDRAC which runs on Linux TPM Trusted Platform Using TPM Enabled Module (TPM) operating systems SW write protected Not user clearable Not user clearable F2 Setup option...
... Dell Inc. Trademarks used in this text: Dell™, the DELL logo, and PowerEdge™ are trademarks of Volatility for the individual components. IDSDM SPI Flash SPI interface via iDRAC Hardware strapping MCU USB3.0 interface via PCH, N/A FW can be updated via iDRAC which runs on Linux TPM Trusted Platform Using TPM Enabled Module (TPM) operating systems SW write protected Not user clearable Not user clearable F2 Setup option...
Operating System Support Matrix - Tech Sheet
Page 1
Trademarks used in this text: Dell™ and the DELL logo are trademarks of Dell Inc. 2013 - 11 All rights reserved. Supported Operating Systems on Dell PowerEdge Servers For the latest information on supported operating systems, see dell.com/ossupport. © 2013 Dell Inc.
Trademarks used in this text: Dell™ and the DELL logo are trademarks of Dell Inc. 2013 - 11 All rights reserved. Supported Operating Systems on Dell PowerEdge Servers For the latest information on supported operating systems, see dell.com/ossupport. © 2013 Dell Inc.