Information Update - Intel Xeon 5600 Series Processors
Page 1
... heat sinks to support Intel Xeon 5600 series processor (less than 130 W). T610 - NOTE: A BIOS and iDRAC firmware update only supports a limited feature set of the Intel Xeon 5600 series processor. • The following new Dell PowerEdge systems marked with the Roman Numeral II on the chassis support the complete feature set of Intel...
... heat sinks to support Intel Xeon 5600 series processor (less than 130 W). T610 - NOTE: A BIOS and iDRAC firmware update only supports a limited feature set of the Intel Xeon 5600 series processor. • The following new Dell PowerEdge systems marked with the Roman Numeral II on the chassis support the complete feature set of Intel...
Information Update
Page 11
... module. CMC Firmware Requirements PowerEdge M905 and M805 blades require CMC firmware version 1.2 or later. Information Update 11 NOTE: See the latest Dell Chassis Management Controller User's Guide at support.dell.com for complete instructions on how to configure and operate the CMC module. During the update process, you add these blades to an M1000e enclosure with your...
... module. CMC Firmware Requirements PowerEdge M905 and M805 blades require CMC firmware version 1.2 or later. Information Update 11 NOTE: See the latest Dell Chassis Management Controller User's Guide at support.dell.com for complete instructions on how to configure and operate the CMC module. During the update process, you add these blades to an M1000e enclosure with your...
Information Update
Page 12
... active or primary CMC. The Firmware Update page appears. 12 Information Update Updating the CMC Firmware Using the Web-based Interface 1 Log in the Web-based interface. Use the following procedure for the standby CMC to the Web-based interface. Failure to the CMC Using the Web-Based Interface" in your M1000e Configuration Guide. 2 Click Chassis...
... active or primary CMC. The Firmware Update page appears. 12 Information Update Updating the CMC Firmware Using the Web-based Interface 1 Log in the Web-based interface. Use the following procedure for the standby CMC to the Web-based interface. Failure to the CMC Using the Web-Based Interface" in your M1000e Configuration Guide. 2 Click Chassis...
Information Update
Page 13
... support.dell.com for complete instructions on your Hardware Owner's Manual and these blades' system information labels. Memory Sparing Requirements The following information updates the memory sparing subsections in Progress." PowerEdge M805 Memory sparing is supported if 24 identical memory modules (DIMMs) are installed. PowerEdge M905 and M805 Blades - Information Update 13 Updating the CMC Firmware Using...
... support.dell.com for complete instructions on your Hardware Owner's Manual and these blades' system information labels. Memory Sparing Requirements The following information updates the memory sparing subsections in Progress." PowerEdge M805 Memory sparing is supported if 24 identical memory modules (DIMMs) are installed. PowerEdge M905 and M805 Blades - Information Update 13 Updating the CMC Firmware Using...
Information Update
Page 14
... Gb Ethernet card • Emulex LPe1205-M FC8 card • ConnectX MDI QDR NOTE: CMC firmware version 1.3 is required to support FC8 mezzanine cards and I/O modules. 14 Information Update For detailed information on configuring a particular card, see the card's documentation on installing a mezzanine ...Intel® Gigabit ET Quad-Port Mezzanine Card. New Mezzanine Cards Your blade now supports the following additional I/O modules: • Dell PowerConnect™ M8024 10 Gb Ethernet switch module • Mellanox M2401G DDR Infiniband switch module • Brocade M5424 FC8 switch module...
... Gb Ethernet card • Emulex LPe1205-M FC8 card • ConnectX MDI QDR NOTE: CMC firmware version 1.3 is required to support FC8 mezzanine cards and I/O modules. 14 Information Update For detailed information on configuring a particular card, see the card's documentation on installing a mezzanine ...Intel® Gigabit ET Quad-Port Mezzanine Card. New Mezzanine Cards Your blade now supports the following additional I/O modules: • Dell PowerConnect™ M8024 10 Gb Ethernet switch module • Mellanox M2401G DDR Infiniband switch module • Brocade M5424 FC8 switch module...
Information Update
Page 18
... Infiniband network established Data transfer is required to Infiniband network Brocade M5424 FC8 I/O Module The Brocade M5424 I /O modules. NOTE: CMC firmware version 1.3 is occurring No logical link to support FC8 mezzanine cards and I /O module includes eight external autosensing Fibre Channel ports (four... four additional ports may be enabled as an optional upgrade), 16 internal ports, and one serial port with this module. 18 Information Update To ensure proper functionality, use only SFPs provided with an RJ-45 connector. Table 1-5. The external Fibre Channel ports operate at ...
... Infiniband network established Data transfer is required to Infiniband network Brocade M5424 FC8 I/O Module The Brocade M5424 I /O modules. NOTE: CMC firmware version 1.3 is occurring No logical link to support FC8 mezzanine cards and I /O module includes eight external autosensing Fibre Channel ports (four... four additional ports may be enabled as an optional upgrade), 16 internal ports, and one serial port with this module. 18 Information Update To ensure proper functionality, use only SFPs provided with an RJ-45 connector. Table 1-5. The external Fibre Channel ports operate at ...
Information Update
Page 37
... RACADM 更新 CMC 固件"。 5 使用 getsysinfo Web CMC 或主 CMC 6 CMC cmcchangeover CMC CMC。 Web CMC 固件 1 Web M1000e Web CMC" 。 2 Chassis 3 单击 Update Updatable Components 4 在 Updatable Components CMC Firmware Update 5 在 Value Browse CMC firmimg.cmc 信息更新 37
... RACADM 更新 CMC 固件"。 5 使用 getsysinfo Web CMC 或主 CMC 6 CMC cmcchangeover CMC CMC。 Web CMC 固件 1 Web M1000e Web CMC" 。 2 Chassis 3 单击 Update Updatable Components 4 在 Updatable Components CMC Firmware Update 5 在 Value Browse CMC firmimg.cmc 信息更新 37
Information Update
Page 38
6 单击 Update 7 单击 Yes "Firmware Update in Progress CMC CMC User Interface 使用 RACADM 更新 CMC 固件 1 打开 CMC 2 键入: racadm fwupdate -g -u -a -d m 请参阅 support.dell.com Dell CMC PowerEdge M905 和 M805 PowerEdge M905 24 DIMM PowerEdge M805 16 38 信息更新
6 单击 Update 7 单击 Yes "Firmware Update in Progress CMC CMC User Interface 使用 RACADM 更新 CMC 固件 1 打开 CMC 2 键入: racadm fwupdate -g -u -a -d m 请参阅 support.dell.com Dell CMC PowerEdge M905 和 M805 PowerEdge M905 24 DIMM PowerEdge M805 16 38 信息更新
Dell PowerEdge M1000e Configuration Guide
Page 4
... . . . . 34 Configuring and Managing Power 35 Installing or Updating the CMC Firmware . . . . . 35 Configuring the Optional iKVM Switch Module . . . . 38 Enabling iKVM Access to the Dell CMC Console 38 Updating the iKVM Firmware 38 Tiering the Avocent iKVM Switch From an Analog KVM Switch 39 ... Network Information 52 Switch Modules 52 Configuring a Switch Module Network Ethernet Port Using the Web-Based Interface 52 Dell PowerConnect-KR 8024-k Switch 53 Dell M8428-k 10 Gb Converged Network Switch 55 Mellanox M2401G DDR Infiniband Switch I/O Module 57 Mellanox M3601Q QDR Infiniband...
... . . . . 34 Configuring and Managing Power 35 Installing or Updating the CMC Firmware . . . . . 35 Configuring the Optional iKVM Switch Module . . . . 38 Enabling iKVM Access to the Dell CMC Console 38 Updating the iKVM Firmware 38 Tiering the Avocent iKVM Switch From an Analog KVM Switch 39 ... Network Information 52 Switch Modules 52 Configuring a Switch Module Network Ethernet Port Using the Web-Based Interface 52 Dell PowerConnect-KR 8024-k Switch 53 Dell M8428-k 10 Gb Converged Network Switch 55 Mellanox M2401G DDR Infiniband Switch I/O Module 57 Mellanox M3601Q QDR Infiniband...
Dell PowerEdge M1000e Configuration Guide
Page 35
...spin at 100 percent during a CMC failover or failback. Failure to do so may cause unexpected behavior during CMC or iDRAC firmware updates on the demand. Configuring Power Budget and Redundancy The CMC's power management service optimizes power consumption for redundant CMC deployments. ...in the CMC User's Guide. Use the following sections. The Budget/Redundancy Configuration page is displayed. 4 Click the Configuration sub-tab. Updating Firmware in the enclosure and your needs. 6 Click Apply to save your changes. Configuring and Managing Power You can use the Web-based...
...spin at 100 percent during a CMC failover or failback. Failure to do so may cause unexpected behavior during CMC or iDRAC firmware updates on the demand. Configuring Power Budget and Redundancy The CMC's power management service optimizes power consumption for redundant CMC deployments. ...in the CMC User's Guide. Use the following sections. The Budget/Redundancy Configuration page is displayed. 4 Click the Configuration sub-tab. Updating Firmware in the enclosure and your needs. 6 Click Apply to save your changes. Configuring and Managing Power You can use the Web-based...
Dell PowerEdge M1000e Configuration Guide
Page 36
... through the Web-based interface. 4 After the standby CMC has rebooted, update the firmware on the standby CMC first. Downloading the CMC Firmware Before beginning the firmware update, download the latest firmware version from support.dell.com, and save it to your CMC firmware package: • Compiled CMC firmware code and data • Web-based interface, JPEG, and other...
... through the Web-based interface. 4 After the standby CMC has rebooted, update the firmware on the standby CMC first. Downloading the CMC Firmware Before beginning the firmware update, download the latest firmware version from support.dell.com, and save it to your CMC firmware package: • Compiled CMC firmware code and data • Web-based interface, JPEG, and other...
Dell PowerEdge M1000e Configuration Guide
Page 37
NOTE: The default CMC firmware image name is reset. The firmware transfer process begins and the status displays the message Firmware Update in to continue. Updating the CMC Firmware Using RACADM 1 Open a CMC command line console and log in. 2 Type: racadm fwupdate -g -u -a -d -m See the latest Dell Chassis Management Controller User's Guide at support.dell.com/manuals for complete instructions...
NOTE: The default CMC firmware image name is reset. The firmware transfer process begins and the status displays the message Firmware Update in to continue. Updating the CMC Firmware Using RACADM 1 Open a CMC command line console and log in. 2 Type: racadm fwupdate -g -u -a -d -m See the latest Dell Chassis Management Controller User's Guide at support.dell.com/manuals for complete instructions...
Dell PowerEdge M1000e Configuration Guide
Page 38
... been uploaded successfully. 1 Log in to locate ikvm.bin, determine whether another user has renamed the file. 6 Click Update. The Firmware Update page is displayed. 4 Select Allow access to CMC CLI from iKVM. 5 Click Apply to the CMC Web-based interface. 2 Select iKVM in to the CMC ... Yes to access the CMC directly and securely through the iKVM's CMC Console option. Configuring the Optional iKVM Switch Module Enabling iKVM Access to the Dell CMC Console Enabling access to the CMC allows you to continue. To enable the CMC Console using the Web-based interface: 1 Log in the system...
... been uploaded successfully. 1 Log in to locate ikvm.bin, determine whether another user has renamed the file. 6 Click Update. The Firmware Update page is displayed. 4 Select Allow access to CMC CLI from iKVM. 5 Click Apply to the CMC Web-based interface. 2 Select iKVM in to the CMC ... Yes to access the CMC directly and securely through the iKVM's CMC Console option. Configuring the Optional iKVM Switch Module Enabling iKVM Access to the Dell CMC Console Enabling access to the CMC allows you to continue. To enable the CMC Console using the Web-based interface: 1 Log in the system...
Dell PowerEdge M1000e Configuration Guide
Page 44
...PowerEdge M600/M605 LAN on a Secure Digital (SD) card that must be inserted into the CMC. FlexAddress Plus The FlexAddress Plus is delivered on motherboard (LOM) Boot code firmware 4.4.1 or later iSCSI boot firmware 2.7.11 or later iDRAC Version 1.11 or later 44 Initial System Configuration You must apply these updates...the following table, include server module BIOS, I/O mezzanine BIOS or firmware, and CMC firmware. FlexAddress Plus expands the number of MAC addresses to prevent accidently modifying any of 208. The updates, which are listed in the USB "Memory Card Reader" to 3136...
...PowerEdge M600/M605 LAN on a Secure Digital (SD) card that must be inserted into the CMC. FlexAddress Plus The FlexAddress Plus is delivered on motherboard (LOM) Boot code firmware 4.4.1 or later iSCSI boot firmware 2.7.11 or later iDRAC Version 1.11 or later 44 Initial System Configuration You must apply these updates...the following table, include server module BIOS, I/O mezzanine BIOS or firmware, and CMC firmware. FlexAddress Plus expands the number of MAC addresses to prevent accidently modifying any of 208. The updates, which are listed in the USB "Memory Card Reader" to 3136...
Hardware Owner's Manual
Page 45
... power supplies in progress. Amber blinking A fault has occurred. Table 1-10. Green CMC has power. Blue (solid) This CMC is the standby CMC. Green blinking Firmware update in standby dynamically depending on load and redundancy requirements to improve power efficiency. - Status/ identification indicator Off This CMC is the primary CMC. The CMC...
... power supplies in progress. Amber blinking A fault has occurred. Table 1-10. Green CMC has power. Blue (solid) This CMC is the standby CMC. Green blinking Firmware update in standby dynamically depending on load and redundancy requirements to improve power efficiency. - Status/ identification indicator Off This CMC is the primary CMC. The CMC...
Hardware Owner's Manual
Page 49
... Network Daughter Card support Port AutoDisablement feature. This feature disables the third (NIC3) and fourth (NIC4) ports of a quad-port Network Daughter Card. NOTE: LOM firmware updates are applied only to the enabled ports on the type of IO module installed. To communicate with an I /O module in the Fabric C slots, a blade must...
... Network Daughter Card support Port AutoDisablement feature. This feature disables the third (NIC3) and fourth (NIC4) ports of a quad-port Network Daughter Card. NOTE: LOM firmware updates are applied only to the enabled ports on the type of IO module installed. To communicate with an I /O module in the Fabric C slots, a blade must...
Fabric OS Message Reference
Page 153
...,, INFO, , Connection established between CP and blade in the indicated slot and determine the AP blade's firmware version. • The CP blade is running an earlier version of firmware than the AP blade. Probable Cause Indicates the control processor (CP) has established a connection to determine ...to the release notes to the blade processor (BP) and can modify the firmware version on the control processor (CP) cannot communicate with the blade processor (BP) to the factory for a firmware update. Because the AP and CP blades cannot communicate, it is the expected behavior....
...,, INFO, , Connection established between CP and blade in the indicated slot and determine the AP blade's firmware version. • The CP blade is running an earlier version of firmware than the AP blade. Probable Cause Indicates the control processor (CP) has established a connection to determine ...to the release notes to the blade processor (BP) and can modify the firmware version on the control processor (CP) cannot communicate with the blade processor (BP) to the factory for a firmware update. Because the AP and CP blades cannot communicate, it is the expected behavior....
Technical Guide
Page 35
... of these bounds in the ESSA tool: http://solutions.dell.com/DellStarOnline/Launch.aspx/ESSA A few things to be aware of the fans to settle back to a quieter state. • Whenever communication to the CMC or iDRAC is lost such as during firmware update, the fan speed will be set to 50% speed... will cause the rest of : • Fans are loud when running at full speed. It is removed, all fans will increase and create more noise. PowerEdge M1000e Technical Guide 34 Please ensure that is appropriate to keep all modules cool. • If a single fan is rare that fans need to a setting that...
... of these bounds in the ESSA tool: http://solutions.dell.com/DellStarOnline/Launch.aspx/ESSA A few things to be aware of the fans to settle back to a quieter state. • Whenever communication to the CMC or iDRAC is lost such as during firmware update, the fan speed will be set to 50% speed... will cause the rest of : • Fans are loud when running at full speed. It is removed, all fans will increase and create more noise. PowerEdge M1000e Technical Guide 34 Please ensure that is appropriate to keep all modules cool. • If a single fan is rare that fans need to a setting that...
Technical Guide
Page 62
...console vendors can initiate and schedule an upgrade to the chassis and installed modules. The M1000e must have at least one serial port. Dell • Integration with BIOS, diagnostics, driver pack, USC, RAID controller firmware, iDRAC6 firmware, and NIC firmware. o Updates are supported. The CMC provides many features, including: Deployment o LCD based... and I/O Modules o Centralized configuration for Network Time Protocol (NTP) Monitoring and Troubleshooting o User interface entry point (web, telnet, SSH, serial) PowerEdge M1000e Technical Guide 61
...console vendors can initiate and schedule an upgrade to the chassis and installed modules. The M1000e must have at least one serial port. Dell • Integration with BIOS, diagnostics, driver pack, USC, RAID controller firmware, iDRAC6 firmware, and NIC firmware. o Updates are supported. The CMC provides many features, including: Deployment o LCD based... and I/O Modules o Centralized configuration for Network Time Protocol (NTP) Monitoring and Troubleshooting o User interface entry point (web, telnet, SSH, serial) PowerEdge M1000e Technical Guide 61
Technical Guide
Page 63
...8213;Virtual Server Reseat‖ simulates blade removal/insertion o Remotely blink LEDs to Identify Components Updating o Reporting of Firmware versions o 1:Many iDRAC Firmware update o Consolidated CMC and iKVM F/W update o 1:Many update of drivers & Firmware via Remote File Share (w/ Repository Manager) o 2 x 10/100/1000Mb Ethernet ports + ... (SSL) and CLI (Telnet/SSH) interfaces Support for chassis environmental conditions or component health thresholds. Dell o Monitoring and alerting for Industry-Standard Interfaces o SMASH CLP o WSMAN o CIM XML PowerEdge M1000e Technical Guide 62
...8213;Virtual Server Reseat‖ simulates blade removal/insertion o Remotely blink LEDs to Identify Components Updating o Reporting of Firmware versions o 1:Many iDRAC Firmware update o Consolidated CMC and iKVM F/W update o 1:Many update of drivers & Firmware via Remote File Share (w/ Repository Manager) o 2 x 10/100/1000Mb Ethernet ports + ... (SSL) and CLI (Telnet/SSH) interfaces Support for chassis environmental conditions or component health thresholds. Dell o Monitoring and alerting for Industry-Standard Interfaces o SMASH CLP o WSMAN o CIM XML PowerEdge M1000e Technical Guide 62