Hardware Owner's Manual (PDF)
Page 3
... Features During Startup 10 Front-Panel Features and Indicators 11 Back-Panel Features and Indicators 14 Connecting External Devices 15 NIC Indicator Codes 15 LCD Status Messages 16 Solving Problems Described by LCD Status Messages 22 Removing LCD Status Messages 23 System Messages 23 Warning ...Messages 30 Diagnostics Messages 30 Alert Messages 31 2 Using the System Setup Program Entering the System Setup Program 33 Responding to Error Messages 33 Using the System Setup Program 34 System Setup Options 34 Main Screen 34 CPU Information Screens 37 Integrated Devices Screen ...
... Features During Startup 10 Front-Panel Features and Indicators 11 Back-Panel Features and Indicators 14 Connecting External Devices 15 NIC Indicator Codes 15 LCD Status Messages 16 Solving Problems Described by LCD Status Messages 22 Removing LCD Status Messages 23 System Messages 23 Warning ...Messages 30 Diagnostics Messages 30 Alert Messages 31 2 Using the System Setup Program Entering the System Setup Program 33 Responding to Error Messages 33 Using the System Setup Program 34 System Setup Options 34 Main Screen 34 CPU Information Screens 37 Integrated Devices Screen ...
Hardware Owner's Manual (PDF)
Page 12
... after the power button is pushed again. Both the system management software and the identification buttons located on . Provides system ID, status information, and system error messages. Table 1-2. Front-Panel Components (continued) Item Component Icon 2 Power-on indicator, power button 3 NMI button 4 System identification button 5 LCD panel Description The power... on . 12 About Your System Used to the system. The LCD lights amber when the system needs attention, and the LCD panel displays an error code followed by the operating system's documentation.
... after the power button is pushed again. Both the system management software and the identification buttons located on . Provides system ID, status information, and system error messages. Table 1-2. Front-Panel Components (continued) Item Component Icon 2 Power-on indicator, power button 3 NMI button 4 System identification button 5 LCD panel Description The power... on . 12 About Your System Used to the system. The LCD lights amber when the system needs attention, and the LCD panel displays an error code followed by the operating system's documentation.
Hardware Owner's Manual (PDF)
Page 16
... For information on page 33. • The power is off and active POST errors are authorized to remove the system cover and access any group of messages with a lower priority. Record the code, then see the systems management software documentation. Setup program. Memory has exceeded acceptable ...powered on page 108. 16 About Your System Battery" on . NOTE: If your Product Information Guide for at least five seconds until an error code appears on the LCD. CMOS battery is missing, or the See "Troubleshooting the System voltage is assigned a priority. The LCD lights blue ...
... For information on page 33. • The power is off and active POST errors are authorized to remove the system cover and access any group of messages with a lower priority. Record the code, then see the systems management software documentation. Setup program. Memory has exceeded acceptable ...powered on page 108. 16 About Your System Battery" on . NOTE: If your Product Information Guide for at least five seconds until an error code appears on the LCD. CMOS battery is missing, or the See "Troubleshooting the System voltage is assigned a priority. The LCD lights blue ...
Hardware Owner's Manual (PDF)
Page 17
... voltage regulator has failed. RPM of acceptable operating range. Cooling Problems" on support.dell.com for the most current system information. About Your System 17 LCD Status Messages (continued) Code E1211 E12nn E1229 E122B E122C E1310 E1410 Text ROMB Batt XX PwrGd CPU # VCORE... "Getting Help" on page 131. Specified voltage regulator has See "Getting Help" on page 131. Specified microprocessor is reporting a system error. Table 1-4. A voltage regulator failure was detected when the processor regulator(s) was enabled See "Getting Help" on page 131. Controller Daughter...
... voltage regulator has failed. RPM of acceptable operating range. Cooling Problems" on support.dell.com for the most current system information. About Your System 17 LCD Status Messages (continued) Code E1211 E12nn E1229 E122B E122C E1310 E1410 Text ROMB Batt XX PwrGd CPU # VCORE... "Getting Help" on page 131. Specified voltage regulator has See "Getting Help" on page 131. Specified microprocessor is reporting a system error. Table 1-4. A voltage regulator failure was detected when the processor regulator(s) was enabled See "Getting Help" on page 131. Controller Daughter...
Hardware Owner's Manual (PDF)
Page 18
.... supply is out of See "Troubleshooting the Power acceptable range; unsupported configuration. processor bus parity error. machine check error. Power supply voltage is cleared using either Server Assistant or the BMC Management Utility. Processors are... a configuration unsupported by Dell. processor protocol error. processor initialization error. Table 1-4. See the Dell OpenManage Baseboard Management Controller User's Guide for information about these utilities. has halted operation. LCD Status Messages (continued) Code E1414 E1418 E141C E141F E1420...
.... supply is out of See "Troubleshooting the Power acceptable range; unsupported configuration. processor bus parity error. machine check error. Power supply voltage is cleared using either Server Assistant or the BMC Management Utility. Processors are... a configuration unsupported by Dell. processor protocol error. processor initialization error. Table 1-4. See the Dell OpenManage Baseboard Management Controller User's Guide for information about these utilities. has halted operation. LCD Status Messages (continued) Code E1414 E1418 E141C E141F E1420...
Hardware Owner's Manual (PDF)
Page 19
...Troubleshooting the Power Supply" on a component that resides in the system, but is faulty. Table 1-4. LCD Status Messages (continued) Code E161C E1620 E1710 E1711 E1712 E1714 E171F Text Causes Corrective Actions PS # Input Lost Power source for specified power supply is faulty.... If problem persists, see "Troubleshooting space at bus ##, device ##, function ##. The system BIOS has reported a PCI parity error on page 108. If the problem persists, the system board is unavailable, or out of acceptable range. that resides in slot #. See...
...Troubleshooting the Power Supply" on a component that resides in the system, but is faulty. Table 1-4. LCD Status Messages (continued) Code E161C E1620 E1710 E1711 E1712 E1714 E171F Text Causes Corrective Actions PS # Input Lost Power source for specified power supply is faulty.... If problem persists, see "Troubleshooting space at bus ##, device ##, function ##. The system BIOS has reported a PCI parity error on page 108. If the problem persists, the system board is unavailable, or out of acceptable range. that resides in slot #. See...
Hardware Owner's Manual (PDF)
Page 20
...Shutdown Test BIOS shutdown test failure. POST Mem Test BIOS POST memory test failure. See "Getting Help" on page 131. Parity Error Parity error. Memory subsystem failure. See "Getting Help" on page 131. See "Getting Help" on page 131. SIO Err SIO failure. ...Unusable Memory Memory is configured, but is installed in the system. Error detected during memory configuration. CMOS Fail CMOS failure. See "Getting Help" on page 131. Table 1-4. LCD Status Messages (continued) Code E1913 E2010 E2011 E2012 E2013 E2014 E2015 E2016 E2017 E2018 E2019 E201A...
...Shutdown Test BIOS shutdown test failure. POST Mem Test BIOS POST memory test failure. See "Getting Help" on page 131. Parity Error Parity error. Memory subsystem failure. See "Getting Help" on page 131. See "Getting Help" on page 131. SIO Err SIO failure. ...Unusable Memory Memory is configured, but is installed in the system. Error detected during memory configuration. CMOS Fail CMOS failure. See "Getting Help" on page 131. Table 1-4. LCD Status Messages (continued) Code E1913 E2010 E2011 E2012 E2013 E2014 E2015 E2016 E2017 E2018 E2019 E201A...
Hardware Owner's Manual (PDF)
Page 21
... disabled memory mirroring because it has Memory" on page 110. LCD Status Messages (continued) Code E201F E2020 E2021 E2022 E2110 E2111 E2112 E2113 Text Causes Corrective Actions DRAC Config Dell remote access controller Check screen for specific error messages. POST Fail General failure after video. About Your System 21 Memory Population Incorrect memory...
... disabled memory mirroring because it has Memory" on page 110. LCD Status Messages (continued) Code E201F E2020 E2021 E2022 E2110 E2111 E2112 E2113 Text Causes Corrective Actions DRAC Config Dell remote access controller Check screen for specific error messages. POST Fail General failure after video. About Your System 21 Memory Population Incorrect memory...
Hardware Owner's Manual (PDF)
Page 22
... of the connections in this table, see the "Glossary" on the Northbound side has failed. E2119 Fatal SB Mem CRC One of three error events. Solving Problems Described by deleting event entries. For example, if you receive a series of the connections in Table 1-4 and perform the... precise fault condition that a microprocessor is unable to determine the problem if multiple related errors occur. Clear the log by LCD Status Messages When a single message appears on the status LCD, locate the code in the Fully Buffered DIMM (FBD) memory subsystem link on page 155. LCD Status...
... of the connections in this table, see the "Glossary" on the Northbound side has failed. E2119 Fatal SB Mem CRC One of three error events. Solving Problems Described by deleting event entries. For example, if you receive a series of the connections in Table 1-4 and perform the... precise fault condition that a microprocessor is unable to determine the problem if multiple related errors occur. Clear the log by LCD Status Messages When a single message appears on the status LCD, locate the code in the Fully Buffered DIMM (FBD) memory subsystem link on page 155. LCD Status...
Hardware Owner's Manual (PDF)
Page 135
...record the contents of each file. Error message, beep code, or diagnostic code: Description of problem and troubleshooting procedures you connected to determine the contents of the system's start-up files. If possible, print each file before calling Dell. Yes No Network, version, and...a network? Diagnostics Checklist Name: Date: Address: Phone number: Service Tag (bar code on the back of the computer): Express Service Code: Return Material Authorization Number (if provided by Dell support technician): Operating system and version: Peripherals: Expansion cards: Are you performed: ...
...record the contents of each file. Error message, beep code, or diagnostic code: Description of problem and troubleshooting procedures you connected to determine the contents of the system's start-up files. If possible, print each file before calling Dell. Yes No Network, version, and...a network? Diagnostics Checklist Name: Date: Address: Phone number: Service Tag (bar code on the back of the computer): Express Service Code: Return Material Authorization Number (if provided by Dell support technician): Operating system and version: Peripherals: Expansion cards: Are you performed: ...
Hardware Owner's Manual (PDF)
Page 160
..., and keyboard drivers are connected in a series, you call Dell for operation. Some devices (such as the last device at each processor has equal access to record system events and errors. Serial Advanced Technology Attachment. Small computer system interface. Disk striping... and storage devices. SCSI - simple disk volume - spanning - System Setup program - See also guarding, mirroring, and RAID. A bar code label on the screen. SATA - An I/O port used to identify it consults the system.ini file to your system's integral components, such...
..., and keyboard drivers are connected in a series, you call Dell for operation. Some devices (such as the last device at each processor has equal access to record system events and errors. Serial Advanced Technology Attachment. Small computer system interface. Disk striping... and storage devices. SCSI - simple disk volume - spanning - System Setup program - See also guarding, mirroring, and RAID. A bar code label on the screen. SATA - An I/O port used to identify it consults the system.ini file to your system's integral components, such...
Information Update
Page 4
...CPU(s) temperature status. System Messages Message Causes Corrective Actions The FBD link to the following memory branch has been disabled: Branch x An error has occurred on the FBD Reseat all of messages with a lower priority. 4 Information Update A fault is unable to the system and... restart the system. When this error problem persists, see "Getting Help" in the second error message. LCD Status Messages Code E1118 E122B E122C Text Causes CPU Temp Interface The BMC is indicated on the channel that can ...
...CPU(s) temperature status. System Messages Message Causes Corrective Actions The FBD link to the following memory branch has been disabled: Branch x An error has occurred on the FBD Reseat all of messages with a lower priority. 4 Information Update A fault is unable to the system and... restart the system. When this error problem persists, see "Getting Help" in the second error message. LCD Status Messages Code E1118 E122B E122C Text Causes CPU Temp Interface The BMC is indicated on the channel that can ...