Question posted by sageb1 on July 5th, 2012

Error Code (e1217 5v Pwdgd) On Front Of Server Read Out Panel

using win 2008 r2 standard

Current Answers

Answer #1: Posted by MWatDell on July 6th, 2012 12:29 AM
This answer was accepted by the poster of the original question.
MWatDell

Member since:
November 17th, 2011

Points: 306,490
1,120
points
Hi sageb1

Error code E1217 - 5V PwrGd is most likely due to motherboard or PCI risers issue.
But to confirm that, you can try to perform a minimum post on the server to isolate the issue.

Minimum components for PE 2950 to post:-
- motherboard
- processor with heatsink on socket 1
- two sticks of memories in slot 1 and 2
- 1 power supply
- control panel
- sideplane riser
- both PCI risers on center and left slot

If the error code remains after you have power up the server with minimum components, then it is confirm the motherboard or the PCI risers need a replacement.

Let us know how it goes

MW@DEll

Dell | Social Outreach Services - Enterprise


<p><a class="twitter-follow-button" href="http://twitter.com/DellCaresPRO">Get Support on Twitter @DellCaresPro</a></p>


MW@Dell

Related Dell PowerEdge 2950 Manual Pages

Information Update - Page 14

... a Hard Drive" in the Hardware Owner's Manual. Check the SEL for processor n Hardware Owner's Manual. Warning! code update loaded See "Getting Help" in the SEL. Table 1-1. System Messages (continued) Message Causes Corrective Actions Warning: A fatal error has caused system reset! See the applicable troubleshooting section in See "Troubleshooting Your System" in the...
Information Update - Page 15

...information only. See "Using the System Setup Program...Code N/A E1000 E1118 Text SYSTEM NAME FAILSAFE, Call Support CPU Temp Interface Causes Corrective Actions A 62-character string that can be defined by the user in the Hardware Owner's Manual. Information Update 15 LCD Status Messages Update Table 1-2 lists updates to the LCD status messages that can occur on the PowerEdge 2950...
Information Update - Page 16

...the Hardware Owner's Manual. 16 Information Update The system BIOS has reported a PCI parity error on a component that resides in PCI configuration space at bus ##, device ##, function ##.... in the Hardware Owner's Manual. Reinstall the expansioncard riser. LCD Status Messages (continued) Code E1211 Text ROMB Batt Causes RAID battery is either missing, bad, or unable to recharge...
Information Update - Page 17

... Update 17 LCD Status Messages (continued) Code E1712 E171F Text Causes Corrective Actions PCI SERR B## D## F## The system BIOS has reported a PCI system error on a component that resides in the Hardware...Err B## D## F## The system BIOS has Remove and reseat the reported a PCIe fatal error PCIe expansion cards. See "Expansion Card Risers" in the Hardware Owner's Manual. If...
Information Update - Page 18

... ## (LCD lights with a blue or amber background.) Video Off in the memory multi-bit error Hardware Owner's (MBE). Reconnect the cable. logging further SBEs until the system is missing or ... Manual. too many errors. Information only. See "Installing a RAC Card" in xx seconds by the RAC remote user. Table 1-2. LCD Status Messages (continued) Code E1914 E1B01 E2110 E2111...
Hardware Owner's Manual (PDF) - Page 3

... Hard-Drive Indicator Codes 15 Back-Panel Features and Indicators 17 Connecting External Devices 17 Power Indicator Codes 18 NIC Indicator Codes 19 LCD Status Messages 19 Solving Problems Described by LCD Status Messages 27 Removing LCD Status Messages 27 System Messages 28 Warning Messages 35 Diagnostics Messages 35 Alert Messages 35 2 Using the System...
Hardware Owner's Manual (PDF) - Page 14

... identification buttons located on . The LCD lights amber when the system needs attention, and the LCD panel displays an error code followed by descriptive text. NOTE: If the system is connected to AC power and an error has been detected, the LCD lights amber regardless of whether the system has been powered on the...
Hardware Owner's Manual (PDF) - Page 19

... Status Messages The system's control panel LCD provides status messages to boot, press the System ID button for at least five seconds until an error code appears on the SEL and configuring...information on the LCD. Figure 1-5. The LCD messages refer to indicate an error condition. NIC Indicator Codes Indicator Link and activity indicators are authorized to remove the system cover and ...
Hardware Owner's Manual (PDF) - Page 20

...Troubleshooting System out of acceptable operating range. Check control panel LCD for information defined by the user in the ... POST errors are displayed. Setup Program" on . Another fan failure additional scrolling messages. Table 1-6. LCD Status Messages Code Text ...page 119. See "RAID Battery" on page 147. See "Using the System • The system is no longer fan- See...
Hardware Owner's Manual (PDF) - Page 21

...Code E1410 E1414 E1418 E141C E141F E1420 E1421 Text CPU # IERR CPU # Thermtrip CPU # Presence CPU Mismatch CPU Protocol CPU Bus PERR CPU Init Causes Corrective Actions Specified microprocessor is cleared using either Server... your system's Getting Started Guide. unsupported configuration. processor bus parity error. Processors are properly installed. The system BIOS has reported a See...
Hardware Owner's Manual (PDF) - Page 40

... Assignment Serial Communication Embedded Server Management System Security Keyboard NumLock (On default) Report Keyboard Errors (Report default) Asset Tag... an asset tag number has been assigned. 40 Using the System Setup Program NOTE: System boot is...chooses an emulation type. Displays a screen to configure the front-panel LCD options and to configure the system password and setup password ...
Hardware Owner's Manual (PDF) - Page 42

... appear on this menu screen if your system does not include this optional device. Options are Enabled without PXE, Enabled with PXE, and Disabled. When using the Read-Only setting, the drive cannot be set to Auto, each channel of the (Auto default) integrated IDE controller is not detected. Embedded Gb NIC1...
Hardware Owner's Manual (PDF) - Page 118

...Action CAUTION: Only trained service technicians are amber. • Front-panel status LCD indicates a problem with the battery. • System... may lose its system configuration information. See "Power Indicator Codes" on page 131. 2 Locate the faulty power supply.... electrical outlet and turn on page 147. See "Using Server Administrator Diagnostics" on page 18. 118 Troubleshooting Your...
Hardware Owner's Manual (PDF) - Page 119

... to recognize the power supply and to determine if it . See "Power Indicator Codes" on page 119. Troubleshooting Your System 119 Operating the system for extended periods of...power supply is amber. • Systems management software issues a fan-related error message. • Front panel LCD indicates a problem with only one power supply at a time in the redundant mode ...
Hardware Owner's Manual (PDF) - Page 120

... an error messages appears, go to remove the system cover and access any of the components inside the computer and protecting against electrostatic discharge. 1 Run the appropriate online diagnostic test. For the identification number of the components inside the computer and protecting against electrostatic discharge. 1 Run the appropriate diagnostic test. See "Using Server...
Hardware Owner's Manual (PDF) - Page 128

...test. Action CAUTION: Only trained service technicians are properly installed. See "Using Server Administrator Diagnostics" on page 147. If the tests fail, see your... processor. d Close the system. Troubleshooting the Microprocessors Problem • Error message indicates a processor problem. • Front-panel status LCD indicates a problem with the processors or system board. &#...
Hardware Owner's Manual (PDF) - Page 160

... Department Name or Service Area, Website and E-Mail Address Japan (Kawasaki) Website: support.jp.dell.com International Access Code: 001 Technical Support (servers) Country Code: 81 Technical Support outside of Japan (servers) City Code: 44 Technical Support (Dimension and Inspiron) Technical Support outside of Japan (Dimension and Inspiron) Technical Support (Dell Precision, OptiPlex...
Hardware Owner's Manual (PDF) - Page 170

... expansion bus - expansion card - COMn - control panel - The part of data between the processor and ...and attributes that allows the processor to bypass the processor. Error checking and correction. EEPROM - Electromagnetic compatibility. EMI - ...correctly with DMI. The device names for your network server using a remote access controller. Central processing unit. DC ...
Hardware Owner's Manual (PDF) - Page 173

.... PCI - Pixels are prohibited from their system using the hard drive The Windows 2000 and UNIX 32... servers and storage systems in ROM code. PS/2 - The system's primary temporary storage area for increasing addressable memory by the number of data. Read-only...running the Windows operating system to a system. A standard for processor. Remote access controller. CPU is lost ...
Hardware Owner's Manual (PDF) - Page 179

...system, 89 troubleshooting, 120 memory modules removing, 92 messages alert, 35 error messages, 37 hard-drive indicator codes, 15 status LCD, 19 system, 28 warning, 35 microprocessors troubleshooting, ... controller (integrated) troubleshooting, 126 removing battery, 96 bezel, 53 central riser, 100 control panel assembly, 105 cooling fan, 65 cover, 54 diskette drive, 83 diskette drive from drive ...

Similar Questions

Error Code On T610
The Display Panel On The Front Ot The T6210 Has This Code Displaying: St: 08pstk02anyone Know What I...
(Posted by webinfo 7 years ago)
Poweredge 2800 Error Code: Eod76
Receiving error code EOD76 - BP Drive 2 - blinking yellow LED
(Posted by wregal 10 years ago)
How Migrate Dell Power Edge 2950 Red Hat Linux Server To Window Server 2008 R2
My dell power edge 2950 was intalled red hat linux i have tried to migrate from linux to windows ser...
(Posted by mozammelhoq 12 years ago)
Ask a New Question
Use the box below to post a new question about this Dell product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Dell Manuals

Find free Dell PowerEdge 2950 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Dell Reviews

View thousands of Dell user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Dell customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Dell customer service rankings, employee comments and much more from our sister site.

Dell Recalls

Find comprehensive Dell recall information updated hourly on RecallOwl.com.