User Manual
Page 16
... Configuring the Banner 300 Managing the SDM Template 301 Configuring SNTP Authentication and an SNTP Server 301 Setting the System Time and Date Manually . . . 303 Configuring the Expansion Slots 304 Configuring PoE Settings (7024P/7048P Only 305 General System Settings Configuration Examples 308 Configuring... System and Banner Information 308 Configuring SNTP 310 Configuring the Time Manually 312 12 Configuring SNMP 313 SNMP Overview 313 What Is SNMP 313 What Are SNMP Traps 314 Why Is SNMP Needed 315...
... Configuring the Banner 300 Managing the SDM Template 301 Configuring SNTP Authentication and an SNTP Server 301 Setting the System Time and Date Manually . . . 303 Configuring the Expansion Slots 304 Configuring PoE Settings (7024P/7048P Only 305 General System Settings Configuration Examples 308 Configuring... System and Banner Information 308 Configuring SNTP 310 Configuring the Time Manually 312 12 Configuring SNMP 313 SNMP Overview 313 What Is SNMP 313 What Are SNMP Traps 314 Why Is SNMP Needed 315...
User Manual
Page 50
... document uses. In a command line, inclusive brackets indicate a selection of compulsory parameters separated by the | character. A keyboard combination that for the PowerConnect 7000 Series switches are available at support.dell.com/manuals: • Getting Started Guide-provides information about the command-line interface (CLI) commands used to configure and manage the switch. Additional...
... document uses. In a command line, inclusive brackets indicate a selection of compulsory parameters separated by the | character. A keyboard combination that for the PowerConnect 7000 Series switches are available at support.dell.com/manuals: • Getting Started Guide-provides information about the command-line interface (CLI) commands used to configure and manage the switch. Additional...
User Manual
Page 60
....1X and Port-Based Security" on that port, the protection mechanism is to help troubleshoot the configuration of a Dot1x authentication on page 505. Supplicants are manually defined or learned on page 505. 60 Switch Features MAC-Based 802.1X Authentication MAC-based authentication allows multiple supplicants connected to the same port...
....1X and Port-Based Security" on that port, the protection mechanism is to help troubleshoot the configuration of a Dot1x authentication on page 505. Supplicants are manually defined or learned on page 505. 60 Switch Features MAC-Based 802.1X Authentication MAC-based authentication allows multiple supplicants connected to the same port...
User Manual
Page 73
Routing Information Protocol Routing Information Protocol (RIP), like OSPF, is an IGP that have been manually configured. Router Discovery For each interface, you can configure static and default routes and route preferences. Routing Table The routing table displays information about the ...
Routing Information Protocol Routing Information Protocol (RIP), like OSPF, is an IGP that have been manually configured. Router Discovery For each interface, you can configure static and default routes and route preferences. Routing Table The routing table displays information about the ...
User Manual
Page 103
To access the switch by using a Telnet or SSH client. For information about creating a serial connection, see the Getting Started Guide available at support.dell.com/manuals. 1 Connect the DB-9 connector of the supplied serial cable to a management station, and connect the RJ-45 connector to a switch, see ... to use to access the device must have an IP address, and the management station you use the Command-Line Interface (CLI) on a PowerConnect 7000 Series switch. NOTE: For a stack of the front panel and is labeled with the |O|O| symbol. The console port is illuminated on ...
To access the switch by using a Telnet or SSH client. For information about creating a serial connection, see the Getting Started Guide available at support.dell.com/manuals. 1 Connect the DB-9 connector of the supplied serial cable to a management station, and connect the RJ-45 connector to a switch, see ... to use to access the device must have an IP address, and the management station you use the Command-Line Interface (CLI) on a PowerConnect 7000 Series switch. NOTE: For a stack of the front panel and is labeled with the |O|O| symbol. The console port is illuminated on ...
User Manual
Page 117
...of the TFTP server instead of the switch. How Is Basic Network Information Configured? When you perform the initial switch configuration. PowerConnect 7000 Series switches have an external port intended solely for the initial configuration information, you can enable the DHCP client on ...-time. For more information about performing the initial switch configuration by using the wizard, see the Getting Started Guide at support.dell.com/manuals. The only applications available on the OOB port are protocols required to perform the initial switch configuration. It is often easier to...
...of the TFTP server instead of the switch. How Is Basic Network Information Configured? When you perform the initial switch configuration. PowerConnect 7000 Series switches have an external port intended solely for the initial configuration information, you can enable the DHCP client on ...-time. For more information about performing the initial switch configuration by using the wizard, see the Getting Started Guide at support.dell.com/manuals. The only applications available on the OOB port are protocols required to perform the initial switch configuration. It is often easier to...
User Manual
Page 121
... IP Interface Configuration page to assign the Default VLAN IP address and Subnet Mask, the Default Gateway IP address, and to assign a static IP address (Manual) or use DHCP for automatic address assignment. Figure 7-2. IP Interface Configuration (Default VLAN) Assigning Network Information to the Default VLAN To assign an IP Address...
... IP Interface Configuration page to assign the Default VLAN IP address and Subnet Mask, the Default Gateway IP address, and to assign a static IP address (Manual) or use DHCP for automatic address assignment. Figure 7-2. IP Interface Configuration (Default VLAN) Assigning Network Information to the Default VLAN To assign an IP Address...
User Manual
Page 122
.... 5 Click Apply. Route Entry Configuration (Switch Default Gateway) Use the Route Entry Configuration page to configure any additional fields on page 843. 4 If you select Manual for the Switch: To configure the switch default gateway: 1 Open the Route Entry Configuration page. 2 From the Route Type field, select Default. 122 Setting Basic...
.... 5 Click Apply. Route Entry Configuration (Switch Default Gateway) Use the Route Entry Configuration page to configure any additional fields on page 843. 4 If you select Manual for the Switch: To configure the switch default gateway: 1 Open the Route Entry Configuration page. 2 From the Route Type field, select Default. 122 Setting Basic...
User Manual
Page 135
...stack is manageable as the standby, or the system can manually configure which becomes the Master if the Master unit is... the units in Expansion Slots for stacking, the unit automatically operates as a standalone unit. NOTE: Each PowerConnect 7000 Series switch in the stack must have the optional Stacking module installed in this chapter include: •...the Stack (Web) • Managing the Stack (CLI) • Stacking and NSF Usage Scenarios Stacking Overview PowerConnect 7000 Series switches include a stacking feature that allows up to 12 switches to configure and manage a stack of...
...stack is manageable as the standby, or the system can manually configure which becomes the Master if the Master unit is... the units in Expansion Slots for stacking, the unit automatically operates as a standalone unit. NOTE: Each PowerConnect 7000 Series switch in the stack must have the optional Stacking module installed in this chapter include: •...the Stack (Web) • Managing the Stack (CLI) • Stacking and NSF Usage Scenarios Stacking Overview PowerConnect 7000 Series switches include a stacking feature that allows up to 12 switches to configure and manage a stack of...
User Manual
Page 138
... the unit that you add to the stack changes its configured unit number to the lowest unassigned unit number. • If the switch you can manually set the unit number for the switch. If there are any links are UP, the STP reconvergence will remain the Management Unit after it unable...
... the unit that you add to the stack changes its configured unit number to the lowest unassigned unit number. • If the switch you can manually set the unit number for the switch. If there are any links are UP, the STP reconvergence will remain the Management Unit after it unable...
User Manual
Page 211
... panel. Begin generating DSA host keys. Figure 9-38. Begin generating RSA host keys. Secure Public Key Configuration Use the Secure Public Key Configuration page to manually configure SSH public keys to generate SSH key files, SSH must be administratively disabled and there must be no active SSH sessions. • Generate DSA...
... panel. Begin generating DSA host keys. Figure 9-38. Begin generating RSA host keys. Secure Public Key Configuration Use the Secure Public Key Configuration page to manually configure SSH public keys to generate SSH key files, SSH must be administratively disabled and there must be no active SSH sessions. • Generate DSA...
User Manual
Page 212
SSH Public Key Summary 212 Controlling Management Access Figure 9-39. Add 2 Specify the algorithm to use of the public-key cryptography, either DSA or RSA. 3 Specify the user to associate with the public key. 4 Click Configuration to return to configure a public key for SSH. 1 From the Secure Public Key page, click Add. Secure Public Key - Configuring a Public Key Use the following steps to the Secure Public Key page. 5 Select the user name and type the key string. 6 Click Apply. 7 To view the manually-configured public keys, click Summary. Figure 9-40.
SSH Public Key Summary 212 Controlling Management Access Figure 9-39. Add 2 Specify the algorithm to use of the public-key cryptography, either DSA or RSA. 3 Specify the user to associate with the public key. 4 Click Configuration to return to configure a public key for SSH. 1 From the Secure Public Key page, click Add. Secure Public Key - Configuring a Public Key Use the following steps to the Secure Public Key page. 5 Select the user name and type the key string. 6 Click Apply. 7 To view the manually-configured public keys, click Summary. Figure 9-40.
User Manual
Page 222
...management interface by default. ip telnet server disable Disable the Telnet service on the switch. Configuring Telnet and SSH Access Beginning in order to manually ssh specify public keys such as the authorized keys file used by row. • key-string - DSA key key-string [row]... keystring Specify an SSH public key manually. • row - A key pair is disabled by using SSH, which SSH public key you are configuring manually and enter SSH Public Key Configuration mode. • username - crypto key pubkey-chain Enter Public...
...management interface by default. ip telnet server disable Disable the Telnet service on the switch. Configuring Telnet and SSH Access Beginning in order to manually ssh specify public keys such as the authorized keys file used by row. • key-string - DSA key key-string [row]... keystring Specify an SSH public key manually. • row - A key pair is disabled by using SSH, which SSH public key you are configuring manually and enter SSH Public Key Configuration mode. • username - crypto key pubkey-chain Enter Public...
User Manual
Page 272
...up to specify the offset from a Simple Network Time Protocol (SNTP) server, or you manage several standalone PowerConnect 7000 Series switches and have 272 Managing General System Settings The PowerConnect 7024P and 7048P switch ports are IEEE 802.3at-2009compliant (PoE Plus) and can be helpful in the... fall and spring. on page 273 The switch can obtain the time from Coordinated Universal Time (UTC), which is disabled, you can set the time manually. Allows...
...up to specify the offset from a Simple Network Time Protocol (SNTP) server, or you manage several standalone PowerConnect 7000 Series switches and have 272 Managing General System Settings The PowerConnect 7024P and 7048P switch ports are IEEE 802.3at-2009compliant (PoE Plus) and can be helpful in the... fall and spring. on page 273 The switch can obtain the time from Coordinated Universal Time (UTC), which is disabled, you can set the time manually. Allows...
User Manual
Page 283
Figure 11-7. Managing General System Settings 283 Use the SNTP Global Settings page to enable or disable the SNTP client. To display the Clock page, click System → Time Synchronization → Clock in the navigation panel. Clock NOTE: The system time cannot be set the date and time on the switch on the switch. The Clock page also displays information about the time settings configured on the Clock page. Clock If you do not obtain the system time from an SNTP server, you can manually set manually if the SNTP client is enabled.
Figure 11-7. Managing General System Settings 283 Use the SNTP Global Settings page to enable or disable the SNTP client. To display the Clock page, click System → Time Synchronization → Clock in the navigation panel. Clock NOTE: The system time cannot be set the date and time on the switch on the switch. The Clock page also displays information about the time settings configured on the Clock page. Clock If you do not obtain the system time from an SNTP server, you can manually set manually if the SNTP client is enabled.
User Manual
Page 303
... example.) • hh:mm - Command Purpose clock set pattern. clock timezone hours- Month. (The first three letters by name; Setting the System Time and Date Manually Beginning in Privileged EXEC mode, use the preconfigured values. You can enter the time first hh:mm:ss} | and then the date, or the date...
... example.) • hh:mm - Command Purpose clock set pattern. clock timezone hours- Month. (The first three letters by name; Setting the System Time and Date Manually Beginning in Privileged EXEC mode, use the preconfigured values. You can enter the time first hh:mm:ss} | and then the date, or the date...
User Manual
Page 308
PC7048#show system System Description: Dell Ethernet Switch 308 Managing General System Settings Notice that displays when a user connects to alert other switch administrators of an upcoming event. PC7048...General System Settings Configuration Examples This section contains the following examples: • Configuring System and Banner Information • Configuring SNTP • Configuring the Time Manually Configuring System and Banner Information In this example, an administrator configures the following system information: • System name: PC7048 • System contact: Jane Doe...
PC7048#show system System Description: Dell Ethernet Switch 308 Managing General System Settings Notice that displays when a user connects to alert other switch administrators of an upcoming event. PC7048...General System Settings Configuration Examples This section contains the following examples: • Configuring System and Banner Information • Configuring SNTP • Configuring the Time Manually Configuring System and Banner Information In this example, an administrator configures the following system information: • System name: PC7048 • System contact: Jane Doe...
User Manual
Page 312
... +60 minutes 312 Managing General System Settings console(config)#clock summer-time recurring us 3 Set the local time and date. Configuring the Time Manually The commands in this example manually set 16:13.06 03/01/2010 4 Verify the time settings. console(config)#clock set the system time and date. Summer time...
... +60 minutes 312 Managing General System Settings console(config)#clock summer-time recurring us 3 Set the local time and date. Configuring the Time Manually The commands in this example manually set 16:13.06 03/01/2010 4 Verify the time settings. console(config)#clock set the system time and date. Summer time...
User Manual
Page 315
...operates in a stack is important to generate SNMP traps that inform the NMS about events or problems that occur on the switch to manually configure the local engineID for the stack. Traps generated by the switch can configure various features on the switch. Table 12-1 summarizes the...Value Disabled Enabled Disabled Enabled None configured Enabled Configuring SNMP 315 To enable SNMPv3, you view and configure by using the Web-based Dell OpenManage Switch Administrator and the CLI are disabled. Settings that it might not be necessary to use NMS software to manage or monitor...
...operates in a stack is important to generate SNMP traps that inform the NMS about events or problems that occur on the switch to manually configure the local engineID for the stack. Traps generated by the switch can configure various features on the switch. Table 12-1 summarizes the...Value Disabled Enabled Disabled Enabled None configured Enabled Configuring SNMP 315 To enable SNMPv3, you view and configure by using the Web-based Dell OpenManage Switch Administrator and the CLI are disabled. Settings that it might not be necessary to use NMS software to manage or monitor...
User Manual
Page 352
... from a remote server to open a configuration file and view or change its contents. The configuration scripting feature is not available from another switch • To manually edit the file You might upload a configuration file from the switch to a remote server for the following reasons: • To restore a previous configuration • To...
... from a remote server to open a configuration file and view or change its contents. The configuration scripting feature is not available from another switch • To manually edit the file You might upload a configuration file from the switch to a remote server for the following reasons: • To restore a previous configuration • To...