User's Guide
Page 320
... port is current. - Valid only for SFX7101 transceivers on the screen. 4. Indicates that the port is not current. • Max. Enables Auto Negotiation on the firmware. • Firmware Update Status - Inactive - Up-to the switch. Displays the maximum cable length determined by current power backoff level. Defining Port Parameters 1. Half - Auto Negotiation is...
... port is current. - Valid only for SFX7101 transceivers on the screen. 4. Indicates that the port is not current. • Max. Enables Auto Negotiation on the firmware. • Firmware Update Status - Inactive - Up-to the switch. Displays the maximum cable length determined by current power backoff level. Defining Port Parameters 1. Half - Auto Negotiation is...
Getting Started Guide
Page 7
... or left freestanding (placed on documentation and firmware. There is installed near an easily accessible 100-250 VAC, 50-60 Hz outlet. • Clearance - The cabling is routed to 95 percent, non-condensing. Site Preparation PowerConnect 6200 series switches can function as a single... entity. The ambient switch operating temperature range is 0 to 45ºC (32 to 113ºF) at support.dell.com for the latest updates on a flat surface). Before installing the ...
... or left freestanding (placed on documentation and firmware. There is installed near an easily accessible 100-250 VAC, 50-60 Hz outlet. • Clearance - The cabling is routed to 95 percent, non-condensing. Site Preparation PowerConnect 6200 series switches can function as a single... entity. The ambient switch operating temperature range is 0 to 45ºC (32 to 113ºF) at support.dell.com for the latest updates on a flat surface). Before installing the ...
Release Notes
Page 2
Table of Contents Introduction 1 Global Support 1 Firmware Specifications 1 Hardware Supported 2 Added Functionality in this Release 3 Changed Functionality in this Release 11 Deprecated Commands and Parameters 15 Issues Resolved 17 CLI Reference Manual Updates 21 User's Guide Updates 24 Known Issues 25 Known Restrictions and Limitations 28 Layer 2 28 Layer 3 29 Management 31 End of Release Notes 32 ii System Firmware Version 3.2.0.6
Table of Contents Introduction 1 Global Support 1 Firmware Specifications 1 Hardware Supported 2 Added Functionality in this Release 3 Changed Functionality in this Release 11 Deprecated Commands and Parameters 15 Issues Resolved 17 CLI Reference Manual Updates 21 User's Guide Updates 24 Known Issues 25 Known Restrictions and Limitations 28 Layer 2 28 Layer 3 29 Management 31 End of Release Notes 32 ii System Firmware Version 3.2.0.6
Release Notes
Page 3
... MUST follow the procedure set forth in the Dell PowerConnect 6200 Series Release 3.2 Upgrade Procedure included in your switch becoming inoperable. Firmware Specifications Firmware Version Details Boot PROM Name Not Applicable Version No. 3.2.0.6 Release Date May 2010 Firmware Upgrade NOTE: Version 3.2 includes improvements to update the boot code AND firmware. It is recommended that the same version...
... MUST follow the procedure set forth in the Dell PowerConnect 6200 Series Release 3.2 Upgrade Procedure included in your switch becoming inoperable. Firmware Specifications Firmware Version Details Boot PROM Name Not Applicable Version No. 3.2.0.6 Release Date May 2010 Firmware Upgrade NOTE: Version 3.2 includes improvements to update the boot code AND firmware. It is recommended that the same version...
Release Notes
Page 7
...but should be disabled if a Voice VLAN is configured for multiple neighbors on the port. ¾ SSH/SSL Refresh The SSH update incorporates the latest security and bug fixes. The feature prevents a class of man-in a VLAN). The miscreant sends ARP requests...all its unsuspecting neighbors. System Firmware Version 3.2.0.6 Page 5 With MLD snooping, IPv6 multicast data is forwarded to only those interfaces associated with Cisco network equipment and is now called the Multicast Group Membership Discovery (MGMD) Proxy. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes ¾...
...but should be disabled if a Voice VLAN is configured for multiple neighbors on the port. ¾ SSH/SSL Refresh The SSH update incorporates the latest security and bug fixes. The feature prevents a class of man-in a VLAN). The miscreant sends ARP requests...all its unsuspecting neighbors. System Firmware Version 3.2.0.6 Page 5 With MLD snooping, IPv6 multicast data is forwarded to only those interfaces associated with Cisco network equipment and is now called the Multicast Group Membership Discovery (MGMD) Proxy. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes ¾...
Release Notes
Page 10
... from previous releases, the preference for the future extensibility of OSPF. To assign cost-based only on type of server address. 8 System Firmware Version 3.2.0.6 For example, the OSPF LSA may be either IPv6 or IPv4 depending on the interface type, use the no form of this...by OSPF or indirectly by routers to distribute IP to link-layer address resolution information. ¾ ICMP Enhancements (RFC4443) ICMPv6 code is updated to all trap receivers. ¾ auto-cost reference bandwidth and bandwidth Commands Controls how OSPF calculates the default metric for IPv6 (RFC3596)....
... from previous releases, the preference for the future extensibility of OSPF. To assign cost-based only on type of server address. 8 System Firmware Version 3.2.0.6 For example, the OSPF LSA may be either IPv6 or IPv4 depending on the interface type, use the no form of this...by OSPF or indirectly by routers to distribute IP to link-layer address resolution information. ¾ ICMP Enhancements (RFC4443) ICMPv6 code is updated to all trap receivers. ¾ auto-cost reference bandwidth and bandwidth Commands Controls how OSPF calculates the default metric for IPv6 (RFC3596)....
Release Notes
Page 12
...to ping an IPv6 link-local address over the service/network port • SNMP traps and queries via the service/network port ¾ Updated IPv4 Multicast Routing Support The Multicast package code has been extensively re-engineered and furnished with the following: • PIM-DM advanced to RFC...txt, draft-ietf-idmr-dvmrp-mib-11.txt ¾ MLD Snooping Querier MLD Snooping Querier is a small subset of the MLD Router functionality. 10 System Firmware Version 3.2.0.6 it enhances the switch capability to simulate a MLD router in a Layer 2 network thus removing the need to have a MLD Router in ...
...to ping an IPv6 link-local address over the service/network port • SNMP traps and queries via the service/network port ¾ Updated IPv4 Multicast Routing Support The Multicast package code has been extensively re-engineered and furnished with the following: • PIM-DM advanced to RFC...txt, draft-ietf-idmr-dvmrp-mib-11.txt ¾ MLD Snooping Querier MLD Snooping Querier is a small subset of the MLD Router functionality. 10 System Firmware Version 3.2.0.6 it enhances the switch capability to simulate a MLD router in a Layer 2 network thus removing the need to have a MLD Router in ...
Release Notes
Page 13
... state, the link may create a loop in alternate or backup roles. Note: Loop Guard should not have loop guard enabled. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Changed Functionality in this state until it receives a BPDU and it receives a BPDU with the previous version, provides...timer expires, the port is an enhancement of {dns 2}. Ports in this Release ¾ Spanning Tree Update - 802.1Q-2005 Spanning Tree now supports IEEE802.1Q-2005. System Firmware Version 3.2.0.6 Page 11 When a port is no longer receives BPDUs, MSTP considers this parameter will not flush...
... state, the link may create a loop in alternate or backup roles. Note: Loop Guard should not have loop guard enabled. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Changed Functionality in this state until it receives a BPDU and it receives a BPDU with the previous version, provides...timer expires, the port is an enhancement of {dns 2}. Ports in this Release ¾ Spanning Tree Update - 802.1Q-2005 Spanning Tree now supports IEEE802.1Q-2005. System Firmware Version 3.2.0.6 Page 11 When a port is no longer receives BPDUs, MSTP considers this parameter will not flush...
Release Notes
Page 19
... description is configured via the show system id on issuing reload. Resolution Updated the help string to save running -config command. Web: Zone config incorrect with the summertime taken into consideration. Firmware missing no switch 2 priority 2 command does not work. GVRP CLI vs...deleted for the cutthrough configuration to those of issues resolved in SNMP group. Configured non-existing host cannot be changed. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Issues Resolved The following is a list of CLI such that the configuration is understood correctly. Cut...
... description is configured via the show system id on issuing reload. Resolution Updated the help string to save running -config command. Web: Zone config incorrect with the summertime taken into consideration. Firmware missing no switch 2 priority 2 command does not work. GVRP CLI vs...deleted for the cutthrough configuration to those of issues resolved in SNMP group. Configured non-existing host cannot be changed. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Issues Resolved The following is a list of CLI such that the configuration is understood correctly. Cut...
Release Notes
Page 23
...show ip ospf Description Use this command to display the statistics for the check pointing process. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes CLI Reference Manual Updates Non-Stop Forwarding Title nsf no nsf show nsf show checkpoint statistics clear checkpoint statistics vlan routing... the IETF standard implementation of the check pointing process. Use the "no " form of the grace period on a VLAN. System Firmware Version 3.2.0.6 Page 21 Default: Non-stop forwarding. Default: Not applicable This command is optional • planned-only - Use this ...
...show ip ospf Description Use this command to display the statistics for the check pointing process. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes CLI Reference Manual Updates Non-Stop Forwarding Title nsf no nsf show nsf show checkpoint statistics clear checkpoint statistics vlan routing... the IETF standard implementation of the check pointing process. Use the "no " form of the grace period on a VLAN. System Firmware Version 3.2.0.6 Page 21 Default: Non-stop forwarding. Default: Not applicable This command is optional • planned-only - Use this ...
Release Notes
Page 24
..., and then saves the configuration, the older implementation of a protocol group, use the show dot1x Ethernet interface Description The command was updated to display the VLAN Id, or name as a helpful neighbor to create a protocolbased VLAN group. Title show interfaces detail {ethernet ...Configuration information. This has been extended so that any Ethertype may be any valid alpha numeric characters. Default: Not applicable 22 System Firmware Version 3.2.0.6 The group name can be used for assigning a group name to vlan protocol group id. • groupid-The protocol...
..., and then saves the configuration, the older implementation of a protocol group, use the show dot1x Ethernet interface Description The command was updated to display the VLAN Id, or name as a helpful neighbor to create a protocolbased VLAN group. Title show interfaces detail {ethernet ...Configuration information. This has been extended so that any Ethertype may be any valid alpha numeric characters. Default: Not applicable 22 System Firmware Version 3.2.0.6 The group name can be used for assigning a group name to vlan protocol group id. • groupid-The protocol...
Release Notes
Page 26
... control the operational state of the dependent link. Default: Not applicable. User's Guide Updates Configuring Dell PowerConnect Title User's Guide Configuration Guide Description See: Dell™ PowerConnect™ 6200 Series User's Guide See: Dell™ PowerConnect™ 6200 Series Configuration Guide 24 System Firmware Version 3.2.0.6 Causes the group members to change their operational state to follow that of...
... control the operational state of the dependent link. Default: Not applicable. User's Guide Updates Configuring Dell PowerConnect Title User's Guide Configuration Guide Description See: Dell™ PowerConnect™ 6200 Series User's Guide See: Dell™ PowerConnect™ 6200 Series Configuration Guide 24 System Firmware Version 3.2.0.6 Causes the group members to change their operational state to follow that of...
Release Notes
Page 29
... change LAG mode from Static to authorize IP phone based on the received LLDP packet (with network policy TLV). System Firmware Version 3.2.0.6 Page 27 PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Summary ISDP updates are not including Voice VLAN Reply TLV when Voice VLAN ID on interface is changed . Cannot change the LACP...
... change LAG mode from Static to authorize IP phone based on the received LLDP packet (with network policy TLV). System Firmware Version 3.2.0.6 Page 27 PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Summary ISDP updates are not including Voice VLAN Reply TLV when Voice VLAN ID on interface is changed . Cannot change the LACP...