Command Line Interface Guide
Page 263
... ---------1/e1 1/e2 1/e3 Capabilities ---------Yes Yes Yes Network Policy ---------Yes: 1 Yes: 1 No Location -------Yes Yes No PoE ---Yes Yes Yes console# show lldp med configuration ethernet 1/1 Port ---------1/e1 Capabilities ---------Yes Network Policy ---------Yes: 1 Location -------Yes PoE ---Yes show lldp local To display the Link Layer Discovery Protocol (LLDP) information that is advertised...
... ---------1/e1 1/e2 1/e3 Capabilities ---------Yes Yes Yes Network Policy ---------Yes: 1 Yes: 1 No Location -------Yes Yes No PoE ---Yes Yes Yes console# show lldp med configuration ethernet 1/1 Port ---------1/e1 Capabilities ---------Yes Network Policy ---------Yes: 1 Location -------Yes PoE ---Yes show lldp local To display the Link Layer Discovery Protocol (LLDP) information that is advertised...
User's Guide
Page 11
... device, or as a stand-alone device. The PowerConnect 3524P also provides Power over Ethernet (PoE). PowerConnect units can function either as stacking ports when the device is stacked. The PowerConnect 3524 and 3548 series include the following device types: • PowerConnect 3524 • PowerConnect 3524P • PowerConnect 3548 • PowerConnect 3548P PowerConnect 3524 The PowerConnect 3524 provides 24 10/100Mbps ports plus two SFP...
... device, or as a stand-alone device. The PowerConnect 3524P also provides Power over Ethernet (PoE). PowerConnect units can function either as stacking ports when the device is stacked. The PowerConnect 3524 and 3548 series include the following device types: • PowerConnect 3524 • PowerConnect 3524P • PowerConnect 3548 • PowerConnect 3548P PowerConnect 3524 The PowerConnect 3524 provides 24 10/100Mbps ports plus two SFP...
User's Guide
Page 12
...Figure 1-2. Switch software is managed from a: • Web-based interface • SNMP Management Station • Command Line Interface (CLI) PowerConnect 3524/P and PowerConnect 3548/P devices support stacking up to forward traffic when the device is in the stack must be selected as stacking ports when the device ... copper ports that can be used to eight units per stack, or can be running the same software version. In addition, PowerConnect 3548P provides PoE. All stack members are a single unit. During the Stacking setup, one switch is selected as the Stack Master and another ...
...Figure 1-2. Switch software is managed from a: • Web-based interface • SNMP Management Station • Command Line Interface (CLI) PowerConnect 3524/P and PowerConnect 3548/P devices support stacking up to forward traffic when the device is in the stack must be selected as stacking ports when the device ... copper ports that can be used to eight units per stack, or can be running the same software version. In addition, PowerConnect 3548P provides PoE. All stack members are a single unit. During the Stacking setup, one switch is selected as the Stack Master and another ...
User's Guide
Page 17
...Power over existing LAN cabling, without updating or modifying the network infrastructure. PoE removes the need for placing network devices next to devices over Ethernet (PoE) provides power to power sources. PoE can be used in a pure IPv6 network as well as dual stack...A soft switchover is synchronized between the Stack Master and the Backup Master results in a combined IPv4/IPv6 network. PowerConnect 3548/P port replaces PowerConect 3524/P Port Same Configuration Same Configuration Switching from the Stack Master to the Backup Stack Master The Backup Master replaces the...
...Power over existing LAN cabling, without updating or modifying the network infrastructure. PoE removes the need for placing network devices next to devices over Ethernet (PoE) provides power to power sources. PoE can be used in a pure IPv6 network as well as dual stack...A soft switchover is synchronized between the Stack Master and the Backup Master results in a combined IPv4/IPv6 network. PowerConnect 3548/P port replaces PowerConect 3524/P Port Same Configuration Same Configuration Switching from the Stack Master to the Backup Stack Master The Backup Master replaces the...
User's Guide
Page 30
...PoE Device: • Width - 440 mm (17.32 inch) • Depth - 257 mm (10.118 inch) • Height - 43.2 mm (1.7 inch) LED Definitions The front panel contains light emitting diodes (LED) that indicate the status of the port, while the link/duplex/activity LED is located on The PowerConnect 3524 /P and PowerConnect...LNK/ACT FDX The RJ-45 100 Base-T port on the PowerConnect 3524 /P and PowerConnect 3548/P has two LEDs marked as LNK/ACT. 30 Hardware Description Physical Dimensions The PowerConnect 3524/P and PowerConnect 3548/P devices have the following figure illustrates the 10/100 Base...
...PoE Device: • Width - 440 mm (17.32 inch) • Depth - 257 mm (10.118 inch) • Height - 43.2 mm (1.7 inch) LED Definitions The front panel contains light emitting diodes (LED) that indicate the status of the port, while the link/duplex/activity LED is located on The PowerConnect 3524 /P and PowerConnect...LNK/ACT FDX The RJ-45 100 Base-T port on the PowerConnect 3524 /P and PowerConnect 3548/P has two LEDs marked as LNK/ACT. 30 Hardware Description Physical Dimensions The PowerConnect 3524/P and PowerConnect 3548/P devices have the following figure illustrates the 10/100 Base...
User's Guide
Page 35
... Static OFF Stacking Master LED Green Static OFF Description The switch is required. Power supply LEDs indicate the status of 370W for 24 ports PoE device. The PowerConnect 3524/P and PowerConnect 3548/P devices have an internal power supply (12 Volt). The Stacking LEDs are numbered 1- 8. Power Supplies The device has an internal power supply...
... Static OFF Stacking Master LED Green Static OFF Description The switch is required. Power supply LEDs indicate the status of 370W for 24 ports PoE device. The PowerConnect 3524/P and PowerConnect 3548/P devices have an internal power supply (12 Volt). The Stacking LEDs are numbered 1- 8. Power Supplies The device has an internal power supply...
User's Guide
Page 37
Operation can be verified by power-up or low-voltage conditions. The non-PoE PowerConnect 3524 and PowerConnect 3548 devices have five built-in fans. Ventilation System The PowerConnect 3524/P and PowerConnect 3548/P switches with the PoE feature have two built-in fans. Hardware Description 37 The single reset circuit of the device. If the Master device is reset...
Operation can be verified by power-up or low-voltage conditions. The non-PoE PowerConnect 3524 and PowerConnect 3548 devices have five built-in fans. Ventilation System The PowerConnect 3524/P and PowerConnect 3548/P switches with the PoE feature have two built-in fans. Hardware Description 37 The single reset circuit of the device. If the Master device is reset...
User's Guide
Page 39
...currently installed by checking that the PoE LEDs on the front panel are included: • Device/Switch • AC power cable • RS-232 crossover cable • Self-adhesive rubber pads Installing the PowerConnect 3524/P and PowerConnect 3548/P 39 The RPS is correctly...is installed near an easily accessible 100-240 VAC, 50-60 Hz outlet. • General - Installing the PowerConnect 3524/P and PowerConnect 3548/P Site Preparation The Dell™ PowerConnect™ 3524 /P and PowerConnect 3548/P devices can be mounted in a standard 48.26-am (19-inch) equipment rack, placed on ...
...currently installed by checking that the PoE LEDs on the front panel are included: • Device/Switch • AC power cable • RS-232 crossover cable • Self-adhesive rubber pads Installing the PowerConnect 3524/P and PowerConnect 3548/P 39 The RPS is correctly...is installed near an easily accessible 100-240 VAC, 50-60 Hz outlet. • General - Installing the PowerConnect 3524/P and PowerConnect 3548/P Site Preparation The Dell™ PowerConnect™ 3524 /P and PowerConnect 3548/P devices can be mounted in a standard 48.26-am (19-inch) equipment rack, placed on ...
User's Guide
Page 90
... device is operating normally. - Not Present - The possible field values are : - The power supply is displayed. • Power Supply Status - The non-PoE devices have two fans, while the PoE devices have five fans. The fan is not operating normally. - The fan is operating normally. - Not Present - Checked - The device temperature threshold...
... device is operating normally. - Not Present - The possible field values are : - The power supply is displayed. • Power Supply Status - The non-PoE devices have two fans, while the PoE devices have five fans. The fan is not operating normally. - The fan is operating normally. - Not Present - Checked - The device temperature threshold...
User's Guide
Page 92
... without updating or modifying the network infrastructure. To open the Power Over Ethernet page. Powered devices are devices which receive power from the PowerConnect power supplies, for example IP phones. Fan1 1 Fan2 OK Fan3 OK Fan4 OK Fan5 OK Unit 1 Temperature (Celsius) 27 Temperature ...Sensor Status OK Unit 1 Up time 00,09:30:36 Managing Power over Ethernet Power over Ethernet (PoE) provides power to devices over Ethernet in the tree view. 92 Configuring System Information Powered Devices are connected via Ethernet ports. Power...
... without updating or modifying the network infrastructure. To open the Power Over Ethernet page. Powered devices are devices which receive power from the PowerConnect power supplies, for example IP phones. Fan1 1 Fan2 OK Fan3 OK Fan4 OK Fan5 OK Unit 1 Temperature (Celsius) 27 Temperature ...Sensor Status OK Unit 1 Up time 00,09:30:36 Managing Power over Ethernet Power over Ethernet (PoE) provides power to devices over Ethernet in the tree view. 92 Configuring System Information Powered Devices are connected via Ethernet ports. Power...
User's Guide
Page 94
...The possible field values are defined and assigned to the powered interface connected to the device using the PoE module. Delevering Power - Indicates that the PowerConnect device is displayed in Watts. • Consumed Power - Indicates the percentage of power consumed before an...fault on the device. - Indicates the amount of power the device can supply. Enables PoE traps on the powered device. Indicates the device PoE mode. Searching is functioning. - Indicates that the PowerConnect device is enabled to learn their classification. Off - For example, a power overload or...
...The possible field values are defined and assigned to the powered interface connected to the device using the PoE module. Delevering Power - Indicates that the PowerConnect device is displayed in Watts. • Consumed Power - Indicates the percentage of power consumed before an...fault on the device. - Indicates the amount of power the device can supply. Enables PoE traps on the powered device. Indicates the device PoE mode. Searching is functioning. - Indicates that the PowerConnect device is enabled to learn their classification. Off - For example, a power overload or...
User's Guide
Page 96
...the inline power on the Power Over Ethernet page. The Power Over Ethernet Table opens. Power Over Ethernet Table Managing PoE Using the CLI Commands The following table summarizes the equivalent CLI commands for viewing fields displayed on an interface. power ...the point of view of the powered device type. Displaying PoE Settings for triggering alarms power inline traps enable Enables PoE device traps show power inline [ethernet Displays PoE configuration information interface ] 96 Configuring System Information PoE settings are defined, and the device is updated. Table ...
...the inline power on the Power Over Ethernet page. The Power Over Ethernet Table opens. Power Over Ethernet Table Managing PoE Using the CLI Commands The following table summarizes the equivalent CLI commands for viewing fields displayed on an interface. power ...the point of view of the powered device type. Displaying PoE Settings for triggering alarms power inline traps enable Enables PoE device traps show power inline [ethernet Displays PoE configuration information interface ] 96 Configuring System Information PoE settings are defined, and the device is updated. Table ...
User's Guide
Page 97
... Class ity low class0 low class0 low class0 low class0 low class0 low class0 Configuring System Information 97 The following is an example of the PoE CLI commands.
... Class ity low class0 low class0 low class0 low class0 low class0 low class0 Configuring System Information 97 The following is an example of the PoE CLI commands.
User's Guide
Page 214
...MED Port Settings page. 2 Click Details. Location - Advertises the network policy attached to a port. • Location Coordinate (16 Bytes in hex. PoE-PSE - The possible field values are saved to the device. Displays the device's location map coordinates (16 bytes in hex). • Location Civic...The possible field value are 6 - 160 bytes in hex. • Location ECS ELIN (10-25 Bytes in Hex) - The field range is a PoE or PSE (Power Sourcing Equipment) device. • Network Policy/Available Network Policy - • Tx Optional TLVs/Available TLVs - Displays the device's civic...
...MED Port Settings page. 2 Click Details. Location - Advertises the network policy attached to a port. • Location Coordinate (16 Bytes in hex. PoE-PSE - The possible field values are saved to the device. Displays the device's location map coordinates (16 bytes in hex). • Location Civic...The possible field value are 6 - 160 bytes in hex. • Location ECS ELIN (10-25 Bytes in Hex) - The field range is a PoE or PSE (Power Sourcing Equipment) device. • Network Policy/Available Network Policy - • Tx Optional TLVs/Available TLVs - Displays the device's civic...
User's Guide
Page 473
..., 460 MDU, 460 Media Endpoint Discovery, 211 Message, 103 Message digest 5, 103, 460 MIB, 219, 460 Multicast, 394 P Passwords, 69, 195 PDU, 461 PING, 461 PoE, 11, 17, 92 Port, 29 Port LEDs, 30 Port mirroring, 312 Ports, 71, 297, 437 Power over Ethernet, 11, 17, 92 Power supplies, 35, 90...
..., 460 MDU, 460 Media Endpoint Discovery, 211 Message, 103 Message digest 5, 103, 460 MIB, 219, 460 Multicast, 394 P Passwords, 69, 195 PDU, 461 PING, 461 PoE, 11, 17, 92 Port, 29 Port LEDs, 30 Port mirroring, 312 Ports, 71, 297, 437 Power over Ethernet, 11, 17, 92 Power supplies, 35, 90...
Getting Started Guide
Page 7
...) are illuminated. The Redundant Power Supply (RPS) is correctly installed by checking that the LEDs on the front panel ( For PoE models) are illuminated. • LEDs on the front panel are illuminated. • Clearance - Allow clearance for operator access. The cabling is adequate ... series switches. Extended Power Supply (EPS) is 0 to 45ºC (32 to 90%, non-condensing. For more information, see the Dell™ PowerConnect™ 3500 Series User's Guide, which is installed near an easily accessible 100-240 VAC, 50-60 Hz outlet. • General - Installation Overview...
...) are illuminated. The Redundant Power Supply (RPS) is correctly installed by checking that the LEDs on the front panel ( For PoE models) are illuminated. • LEDs on the front panel are illuminated. • Clearance - Allow clearance for operator access. The cabling is adequate ... series switches. Extended Power Supply (EPS) is 0 to 45ºC (32 to 90%, non-condensing. For more information, see the Dell™ PowerConnect™ 3500 Series User's Guide, which is installed near an easily accessible 100-240 VAC, 50-60 Hz outlet. • General - Installation Overview...