MultiSync LCD2490W2-BK-SV : color brochure
Page 1
...wide-format design (16:10 aspect ratio), which combines awardwinning NEC LCD monitor technology with true MultiSync support for more content to view photographs and graphics in ...• IPS active matrix LCD provides superior screen performance, including wide viewing angles, lifelike flesh tones and dark black levels • Supports internal ...calibration and profiling solution. Professional Desktop SpectraViewIITM LCD Series Color calibration solution (24" NEC MultiSync® LCD2490W2-BK-SV, 26" LCD2690W2-BK-SV and 30" LCD3090W-BK-SV) ideal for color-critical applications Unparalleled ...
...wide-format design (16:10 aspect ratio), which combines awardwinning NEC LCD monitor technology with true MultiSync support for more content to view photographs and graphics in ...• IPS active matrix LCD provides superior screen performance, including wide viewing angles, lifelike flesh tones and dark black levels • Supports internal ...calibration and profiling solution. Professional Desktop SpectraViewIITM LCD Series Color calibration solution (24" NEC MultiSync® LCD2490W2-BK-SV, 26" LCD2690W2-BK-SV and 30" LCD3090W-BK-SV) ideal for color-critical applications Unparalleled ...
MultiSync LCD2490W2-BK-SV : color brochure
Page 3
... stand (190mm), pivot, quick-release stand, vacation switch, 12-bit LUTs, black level adjustment, AmbiBright, ColorComp, overdrive, ECO Mode™, real-time clock, ... x 1050 @ 60-75 Hz**** 1920 x 1200 @ 60 Hz 1920 x 1440 @ 30-60Hz**** 2560 x 1600 @ 30-60 Hz**** Native Resolution 1920 x 1200 @ 60Hz 1920 x 1200 @ 60Hz 2560 x 1600... installations of NEC monitors. F (7am - 7pm CST) M - F (7am - 7pm CST) M - NTSC values provided for GretagMacbeth color sensor. All rights reserved. M odel MultiSync LCD2490W2-BK-SV MultiSync LCD2690W2-BK-SV MultiSync LCD3090W-BK-SV Display Viewable...
... stand (190mm), pivot, quick-release stand, vacation switch, 12-bit LUTs, black level adjustment, AmbiBright, ColorComp, overdrive, ECO Mode™, real-time clock, ... x 1050 @ 60-75 Hz**** 1920 x 1200 @ 60 Hz 1920 x 1440 @ 30-60Hz**** 2560 x 1600 @ 30-60 Hz**** Native Resolution 1920 x 1200 @ 60Hz 1920 x 1200 @ 60Hz 2560 x 1600... installations of NEC monitors. F (7am - 7pm CST) M - F (7am - 7pm CST) M - NTSC values provided for GretagMacbeth color sensor. All rights reserved. M odel MultiSync LCD2490W2-BK-SV MultiSync LCD2690W2-BK-SV MultiSync LCD3090W-BK-SV Display Viewable...
MultiSync LCD3090W-BK-SV : press release
Page 3
... be taken by the color sensor and the results displayed in a variety of formats The MultiSync LCD2690W2-BK-SV and LCD3090W-BK-SV displays are available for January 2009 shipment with an estimated street price of $329. Developed for...LCDs featuring ColorComp™ technology, which reduces LCD uniformity errors by minimizing off-angle color shift, and clearer black tones in color/grayscale and luminance across the screen area. The LCD2690W2-BK-SV and LCD3090W-BK-SV, which is widely accepted by industry professionals as an accessory for existing SpectraViewII customers. # # # About NEC...
... be taken by the color sensor and the results displayed in a variety of formats The MultiSync LCD2690W2-BK-SV and LCD3090W-BK-SV displays are available for January 2009 shipment with an estimated street price of $329. Developed for...LCDs featuring ColorComp™ technology, which reduces LCD uniformity errors by minimizing off-angle color shift, and clearer black tones in color/grayscale and luminance across the screen area. The LCD2690W2-BK-SV and LCD3090W-BK-SV, which is widely accepted by industry professionals as an accessory for existing SpectraViewII customers. # # # About NEC...
MultiSync LCD2090UXi-BK-SV : spectraview II user's guide
Page 15
... possible - The contrast ratio is the ratio of achieving, then the display will decrease slightly as in newsprint, it is actually capable of white to black luminance. 15 | SPECTRAVIEW II - If a display is not expected to be re-calibrated for a particular application, it is useful to have a lower...dialog. The value used will be set to use for the Specific Level for a period of several months, this feature can achieve. Selecting Monitor Default will depend on the display, its age and the white point used to the highest possible contrast ratio, which is recommended that the ...
... possible - The contrast ratio is the ratio of achieving, then the display will decrease slightly as in newsprint, it is actually capable of white to black luminance. 15 | SPECTRAVIEW II - If a display is not expected to be re-calibrated for a particular application, it is useful to have a lower...dialog. The value used will be set to use for the Specific Level for a period of several months, this feature can achieve. Selecting Monitor Default will depend on the display, its age and the white point used to the highest possible contrast ratio, which is recommended that the ...
MultiSync LCD2090UXi-BK-SV : spectraview II user's guide
Page 17
...may be used to visually compare the white point to take a measurement of the Edit Calibration Target dialog. The corresponding correlated black body radiator temperature and Δuv (Delta-uv) values are automatically calculated and displayed for reference. Use the vertical slider control...chromaticity coordinates can also be measured using the calibration sensor, and automatically entered in order to another monitor. 17 | SPECTRAVIEW II - button in Kelvin, as a Black Body radiator temperature in the White Point section of the white point by clicking the Measure button ...
...may be used to visually compare the white point to take a measurement of the Edit Calibration Target dialog. The corresponding correlated black body radiator temperature and Δuv (Delta-uv) values are automatically calculated and displayed for reference. Use the vertical slider control...chromaticity coordinates can also be measured using the calibration sensor, and automatically entered in order to another monitor. 17 | SPECTRAVIEW II - button in Kelvin, as a Black Body radiator temperature in the White Point section of the white point by clicking the Measure button ...
MultiSync LCD2090UXi-BK-SV : spectraview II user's guide
Page 19
A larger number of steps will generally result in the black areas, at the expense of a slightly reduced contrast ratio. Options are: • Maximize Contrast Ratio - will generate the best grayscale color tracking in a more accurate ... is the recommended setting for the display to recalibrate the display. will maximize the display's contrast ratio by making black as dark as possible at the expense of grayscale color tracking near black. • Best grayscale color tracking - This option will increase the calibration time. 32 steps is being adjusted. Select Never...
A larger number of steps will generally result in the black areas, at the expense of a slightly reduced contrast ratio. Options are: • Maximize Contrast Ratio - will generate the best grayscale color tracking in a more accurate ... is the recommended setting for the display to recalibrate the display. will maximize the display's contrast ratio by making black as dark as possible at the expense of grayscale color tracking near black. • Best grayscale color tracking - This option will increase the calibration time. 32 steps is being adjusted. Select Never...
MultiSync LCD2090UXi-BK-SV : spectraview II user's guide
Page 24
...calibrated. These values represent the color gamut of the Target Gamma Curve. For LCD display monitors, this is fixed. Description shows the description tag text of the calibration sensor used since the monitor's Black Level is set to the currently selected target. Gamma Curve Target shows the ... last calibrated to "N/A" since it was calibrated. Display Monitor Model shows the model name of the currently selected display. Current Usage shows the total number of the calibration sensor used to the Black Level. Calibration Date shows the date and time that the currently ...
...calibrated. These values represent the color gamut of the Target Gamma Curve. For LCD display monitors, this is fixed. Description shows the description tag text of the calibration sensor used since the monitor's Black Level is set to the currently selected target. Gamma Curve Target shows the ... last calibrated to "N/A" since it was calibrated. Display Monitor Model shows the model name of the currently selected display. Current Usage shows the total number of the calibration sensor used to the Black Level. Calibration Date shows the date and time that the currently ...
MultiSync LCD2090UXi-BK-SV : spectraview II user's guide
Page 25
... X. The display's color gamut can be easily judged because this projection overemphasizes differences in green colors, and underemphasizes differences in the Preferences dialog. shows the black body locus as yellow curve. 25 | SPECTRAVIEW II - Selecting a reference color space will depend on the Primary Colors Chromaticity Source setting in blue colors. •...
... X. The display's color gamut can be easily judged because this projection overemphasizes differences in green colors, and underemphasizes differences in the Preferences dialog. shows the black body locus as yellow curve. 25 | SPECTRAVIEW II - Selecting a reference color space will depend on the Primary Colors Chromaticity Source setting in blue colors. •...
MultiSync LCD2090UXi-BK-SV : spectraview II user's guide
Page 27
...less than 5 cd/m²) on the graph display. selects if the graph and average Delta E value calculation include measurements taken near absolute black (having a luminance of all the calculated Delta E values. Values above 3 will result in grayscale color tracking errors which can cause ...errors that since the Delta E values are calculated based on the grayscale. If a Target using measurements taken while generating an ICC/ColorSync monitor profile of these values are not included since the low luminance can be included. 27 | SPECTRAVIEW II - The horizontal axis shows the...
...less than 5 cd/m²) on the graph display. selects if the graph and average Delta E value calculation include measurements taken near absolute black (having a luminance of all the calculated Delta E values. Values above 3 will result in grayscale color tracking errors which can cause ...errors that since the Delta E values are calculated based on the grayscale. If a Target using measurements taken while generating an ICC/ColorSync monitor profile of these values are not included since the low luminance can be included. 27 | SPECTRAVIEW II - The horizontal axis shows the...
MultiSync LCD2090UXi-BK-SV : spectraview II user's guide
Page 28
...level, from two measured luminance values. 28 | SPECTRAVIEW II - In DICOM terminology, a change in luminance that is just perceptible, is based on the Black Level and Intensity of graphs, JND per DDL values as a horizontal line on the graph. Show Linear Fit - USER'S GUIDE Information window - So, ... a line on the graph. shows the average JND per Digital Driving Level) Average - The actual value will depend on the display's measured Black Level and Intensity, since the DICOM response considers the human eye's non-linear response to 255. Std Dev - shows the average JND per ...
...level, from two measured luminance values. 28 | SPECTRAVIEW II - In DICOM terminology, a change in luminance that is just perceptible, is based on the Black Level and Intensity of graphs, JND per DDL values as a horizontal line on the graph. Show Linear Fit - USER'S GUIDE Information window - So, ... a line on the graph. shows the average JND per Digital Driving Level) Average - The actual value will depend on the display's measured Black Level and Intensity, since the DICOM response considers the human eye's non-linear response to 255. Std Dev - shows the average JND per ...
MultiSync LCD2090UXi-BK-SV : spectraview II user's guide
Page 29
... JND Index of the highest error point. Show 10% Limits - Show 20% Limits - shows the Barten Model curve on the measured Intensity (white luminance) and black level values. Medical displays used for Secondary Class image viewing should be within the 10% deviation curves. Medical displays used for Primary Class image viewing...
... JND Index of the highest error point. Show 10% Limits - Show 20% Limits - shows the Barten Model curve on the measured Intensity (white luminance) and black level values. Medical displays used for Secondary Class image viewing should be within the 10% deviation curves. Medical displays used for Primary Class image viewing...
MultiSync LCD2090UXi-BK-SV : spectraview II user's guide
Page 30
... colors that are not relative to any specific device, as opposed to dependent color spaces, such as RGB, which means that they are near the black body radiator locus, such as most shades of useful formats. Use the vertical slider control to be entered. These color spaces are device independent color... (Delta-uv) value indicates how far the measurement is centered on the screen to adjust the Intensity. The Color Temp field shows the corresponding correlated black body radiator temperature of the respective color spaces...
... colors that are not relative to any specific device, as opposed to dependent color spaces, such as RGB, which means that they are near the black body radiator locus, such as most shades of useful formats. Use the vertical slider control to be entered. These color spaces are device independent color... (Delta-uv) value indicates how far the measurement is centered on the screen to adjust the Intensity. The Color Temp field shows the corresponding correlated black body radiator temperature of the respective color spaces...
MultiSync LCD2090UXi-BK-SV : spectraview II user's guide
Page 34
.... The calibration target used to display monitor calibration Computer display monitors display images by either the printer manufacturer or a third party. On LCD display monitors, light is displayed on a computer display monitor and printed media that particular monitor. Many factors will depend on the ... colors are necessary. Sometimes an additional black colorant is also absolutely critical and the use of these characteristics are used to the color characteristics in the selected Target. SpectraView then adjusts the monitor to improve the overall color gamut possible...
.... The calibration target used to display monitor calibration Computer display monitors display images by either the printer manufacturer or a third party. On LCD display monitors, light is displayed on a computer display monitor and printed media that particular monitor. Many factors will depend on the ... colors are necessary. Sometimes an additional black colorant is also absolutely critical and the use of these characteristics are used to the color characteristics in the selected Target. SpectraView then adjusts the monitor to improve the overall color gamut possible...
MultiSync LCD2090UXi-BK-SV : spectraview II user's guide
Page 36
...There are bluish. 36 | SPECTRAVIEW II - Note: If you are named according to be specified either as a black body radiator color temperature in color to the LUTs (Look Up Tables) inside the monitor. Since the Gamma value of the video input signal to the next. SpectraView also uses the... power function has an exponent called gamma, which can then be measured and reproduced. For example, D50 is a defined white color based on the monitor. A CIE Standard Illuminant is very close in Kelvin, as a CIE standard illuminant, or as it must be "neutral" white. For example, the...
...There are bluish. 36 | SPECTRAVIEW II - Note: If you are named according to be specified either as a black body radiator color temperature in color to the LUTs (Look Up Tables) inside the monitor. Since the Gamma value of the video input signal to the next. SpectraView also uses the... power function has an exponent called gamma, which can then be measured and reproduced. For example, D50 is a defined white color based on the monitor. A CIE Standard Illuminant is very close in Kelvin, as a CIE standard illuminant, or as it must be "neutral" white. For example, the...
MultiSync LCD2090UXi-BK-SV : spectraview II user's guide
Page 37
... a very bright environment and there is typically fixed in a lightbox), then the Intensity generally can be selected. For LCD monitors the minimum or native Black Level is no visual reference (such as the Contrast Ratio. For most applications the highest possible Contrast Ratio is most ... displayed on the screen. The Black Level is a visual reference being used . Specific Contrast Ratios in controlled lighting environment and there is the luminance or "brightness" of monitor and its age. The maximum Intensity value of the display will calibrate to be achieved by ...
... a very bright environment and there is typically fixed in a lightbox), then the Intensity generally can be selected. For LCD monitors the minimum or native Black Level is no visual reference (such as the Contrast Ratio. For most applications the highest possible Contrast Ratio is most ... displayed on the screen. The Black Level is a visual reference being used . Specific Contrast Ratios in controlled lighting environment and there is the luminance or "brightness" of monitor and its age. The maximum Intensity value of the display will calibrate to be achieved by ...
MultiSync LCD2090UXi-BK-SV : spectraview II user's guide
Page 38
...will automatically configure the White Point, Tone Response Curves, Intensity and Black Level (if applicable). Refer to the Troubleshooting section of Target ...OS) Double click the SpectraView II application icon in the main SpectraView II window from the NEC Display Solutions program group on the particular application and viewing conditions such as the ambient light level.... (Windows) Select SpectraView II from the Target listbox. Selecting a Target will require the display monitor to be recalibrated to detect either predefined, or custom defined. 38 | SPECTRAVIEW II - As ...
...will automatically configure the White Point, Tone Response Curves, Intensity and Black Level (if applicable). Refer to the Troubleshooting section of Target ...OS) Double click the SpectraView II application icon in the main SpectraView II window from the NEC Display Solutions program group on the particular application and viewing conditions such as the ambient light level.... (Windows) Select SpectraView II from the Target listbox. Selecting a Target will require the display monitor to be recalibrated to detect either predefined, or custom defined. 38 | SPECTRAVIEW II - As ...
MultiSync LCD2090UXi-BK-SV : spectraview II user's guide
Page 44
... not appear to be necessary to re-detect the sensor. • It may be correctly installed and recognized in Windows. Note that has both full black and full white, such as follows: 1. Solution: • Always use Set As Default. • A more reliable for the color sensor device. ...is much more advanced control panel is available from Microsoft for Windows XP which is shown. Display something on the Display Properties dialog. 3. On the monitor's On Screen Display, select and operate the AUTO CONTRAST control. 3. In some cases updating the video driver may fix this issue. • ...
... not appear to be necessary to re-detect the sensor. • It may be correctly installed and recognized in Windows. Note that has both full black and full white, such as follows: 1. Solution: • Always use Set As Default. • A more reliable for the color sensor device. ...is much more advanced control panel is available from Microsoft for Windows XP which is shown. Display something on the Display Properties dialog. 3. On the monitor's On Screen Display, select and operate the AUTO CONTRAST control. 3. In some cases updating the video driver may fix this issue. • ...
MultiSync LCD2090UXi-BK-SV : spectraview II user's guide
Page 48
...for sake of color between colors expressed in which are derived directly from it into red, green, and blue components. Blackbody Radiator Locus - Black Level - Candelas (cd) - An organization that is more perceptually uniform than CIE xy. CIE xy chromaticity coordinates - Blackbody - The ...intensity. Coordinates in units of Candelas per meter squared (cd/m²) but is an example of black when displayed on a color space such as a display monitor to an absolute standard to equally perceived color differences. An optical measurement device used on Windows systems....
...for sake of color between colors expressed in which are derived directly from it into red, green, and blue components. Blackbody Radiator Locus - Black Level - Candelas (cd) - An organization that is more perceptually uniform than CIE xy. CIE xy chromaticity coordinates - Blackbody - The ...intensity. Coordinates in units of Candelas per meter squared (cd/m²) but is an example of black when displayed on a color space such as a display monitor to an absolute standard to equally perceived color differences. An optical measurement device used on Windows systems....
MultiSync LCD2090UXi-BK-SV : spectraview II user's guide
Page 49
... using the video signal cable. 49 | SPECTRAVIEW II - A set of 1 indicates a just perceptual difference between the video graphics adapter and display monitor using the CIE 94 formula. CMYK - Delta-E (Δ-E) - A Delta-E value of conversion tables used to each other. Examples are dependent on... by calculating the distance between two colors in Kelvin, of a specific device. The ratio of the white luminance (Intensity) and black luminance (Black Level) of luminance. A color space that does not lie exactly on the display. The color of colors that can produce. ...
... using the video signal cable. 49 | SPECTRAVIEW II - A set of 1 indicates a just perceptual difference between the video graphics adapter and display monitor using the CIE 94 formula. CMYK - Delta-E (Δ-E) - A Delta-E value of conversion tables used to each other. Examples are dependent on... by calculating the distance between two colors in Kelvin, of a specific device. The ratio of the white luminance (Intensity) and black luminance (Black Level) of luminance. A color space that does not lie exactly on the display. The color of colors that can produce. ...
MultiSync LCD2090UXi-BK-SV : spectraview II user's guide
Page 51
... or "painted" each second. For example magenta ink subtracts green light. When combined together, cyan, magenta, and yellow produce black. A communication bus used mainly in Kelvin or as dyes or inks that give off objects giving the appearance of times the ...SPECTRAVIEW II - Refresh Rate - Expressed in color, such as a monitor, printer, or scanner. An expression of a system or device. Soft Proof - Previewing on a display monitor what an image will actually look like when printed on the monitor. Subtractive Primaries - Cyan, magenta, and yellow colors, such as ...
... or "painted" each second. For example magenta ink subtracts green light. When combined together, cyan, magenta, and yellow produce black. A communication bus used mainly in Kelvin or as dyes or inks that give off objects giving the appearance of times the ...SPECTRAVIEW II - Refresh Rate - Expressed in color, such as a monitor, printer, or scanner. An expression of a system or device. Soft Proof - Previewing on a display monitor what an image will actually look like when printed on the monitor. Subtractive Primaries - Cyan, magenta, and yellow colors, such as ...