PRESCRIBE Commands Command Reference Manual Rev 4.8
Page 172
set MeDia type ATtribute Format MDAT [media-type[, paper-weight, fuser-mode, duplex[, density]]]; Parameters media-type 1 = Plain 2 = Transparency 3 = Preprinted 4 = Label 5 = Bond 6 = Recycled 7 = Vellum 8 = Rough 9 = Letterhead 10 = Color 11 = Prepunched 12 = Envelope 13 = Cardstock 14 = Coated ...
set MeDia type ATtribute Format MDAT [media-type[, paper-weight, fuser-mode, duplex[, density]]]; Parameters media-type 1 = Plain 2 = Transparency 3 = Preprinted 4 = Label 5 = Bond 6 = Recycled 7 = Vellum 8 = Rough 9 = Letterhead 10 = Color 11 = Prepunched 12 = Envelope 13 = Cardstock 14 = Coated ...
PRESCRIBE Commands Command Reference Manual Rev 4.8
Page 173
MDAT fuser-mode 0 = High 1 = Middle 2 = Low 3 = Vellum duplex 0 = Enable 1 = Disable density 1 = Light 2 = Medium Light 3 = Normal 4 = Medium Heavy 5 = Heavy Function The MDAT command is allowed for optimization. File ... back to customize the default attributes of a media type for duplex printing or not. MDAT 2, 1, 0, 1; If the parameters paper-weight and fuser-mode are reset to the thick paper weight and the high fuser temperature mode, disabling the duplex printing, command: !R! EXIT; The paper-weight attribute affects the printing system's transfer bias...
MDAT fuser-mode 0 = High 1 = Middle 2 = Low 3 = Vellum duplex 0 = Enable 1 = Disable density 1 = Light 2 = Medium Light 3 = Normal 4 = Medium Heavy 5 = Heavy Function The MDAT command is allowed for optimization. File ... back to customize the default attributes of a media type for duplex printing or not. MDAT 2, 1, 0, 1; If the parameters paper-weight and fuser-mode are reset to the thick paper weight and the high fuser temperature mode, disabling the duplex printing, command: !R! EXIT; The paper-weight attribute affects the printing system's transfer bias...
PRESCRIBE Commands Command Reference Manual Rev 4.8
Page 358
... the MP tray for a tray when thickness and print-density parameters are omitted. This command is relevant to optimize the electrical properties (such as the fuser temperature and the transfer bias) so that the best print quality is 3. PRESCRIBE Command Reference TATR - EXIT; TATR; To reset all three parameters are omitted...
... the MP tray for a tray when thickness and print-density parameters are omitted. This command is relevant to optimize the electrical properties (such as the fuser temperature and the transfer bias) so that the best print quality is 3. PRESCRIBE Command Reference TATR - EXIT; TATR; To reset all three parameters are omitted...
PRESCRIBE Commands Command Reference Manual Rev 4.8
Page 407
... priority, 116 font mode, 108, 119 saving current, 270 selection by assigning typeface, 294 Font attributes, 291 Font list, 105 printing a, 105 Font mode, 119 Fuser mode, 162, 163 G Graphics state, 228, 272 Gray pattern, 122 Grouping, 27 H Hard disk, 141, 246, 250, 256, 258 error codes, 136 I Image ...Job separation, 145 choosing first or all pages, 145 separating copies by command, 145 K KCGL pen color, 297 KIR, 304 refinement level, 304 KPDL, 287 Kyocera Image Refinement, 304 L left, 307 Lightness, 155 Line, 73, 80, 82, 87 drawing by angle, 82 drawing to absolute, 73 drawing to relative, 80...
... priority, 116 font mode, 108, 119 saving current, 270 selection by assigning typeface, 294 Font attributes, 291 Font list, 105 printing a, 105 Font mode, 119 Fuser mode, 162, 163 G Graphics state, 228, 272 Gray pattern, 122 Grouping, 27 H Hard disk, 141, 246, 250, 256, 258 error codes, 136 I Image ...Job separation, 145 choosing first or all pages, 145 separating copies by command, 145 K KCGL pen color, 297 KIR, 304 refinement level, 304 KPDL, 287 Kyocera Image Refinement, 304 L left, 307 Lightness, 155 Line, 73, 80, 82, 87 drawing by angle, 82 drawing to absolute, 73 drawing to relative, 80...
PRESCRIBE Commands Technical Reference Manual - Rev. 4.7
Page 105
... Asia) or 1 (Asia) Message language B7 selection at power-on 0: Automatically enters message language 1 selection menu at power-on . Interface-independent Parameters (Sheet 1 of page 0 1: Fuser sensor activated 2: Fuser sensor deactivated 3: Page ejection 4: Same as 0; Interface-independent Parameters Table 6.2. Error is valid. 10: XON is ready or waiting.
... Asia) or 1 (Asia) Message language B7 selection at power-on 0: Automatically enters message language 1 selection menu at power-on . Interface-independent Parameters (Sheet 1 of page 0 1: Fuser sensor activated 2: Fuser sensor deactivated 3: Page ejection 4: Same as 0; Interface-independent Parameters Table 6.2. Error is valid. 10: XON is ready or waiting.
PRESCRIBE Commands Technical Reference Manual - Rev. 4.7
Page 110
... Paper type for paper cassettes 1 to 6 Paper type for Envelope Feeder/ Universal Feeder PCL paper source Automatic continue for 'Press GO' Automatic continue timer Quick fuser heater Parameter Value 8: Rough 9: Letterhead 10: Color 11: Prepunched 12: Envelope 13: Cardstock 21: Custom1 22: Custom2 23: Custom3 24: Custom4 25: Custom5 26: Custom6...
... Paper type for paper cassettes 1 to 6 Paper type for Envelope Feeder/ Universal Feeder PCL paper source Automatic continue for 'Press GO' Automatic continue timer Quick fuser heater Parameter Value 8: Rough 9: Letterhead 10: Color 11: Prepunched 12: Envelope 13: Cardstock 21: Custom1 22: Custom2 23: Custom3 24: Custom4 25: Custom5 26: Custom6...