... Format for Error Recovery For all models, EXCEPT 40fx and 80ex B-8 Hardware Error Codes B-19 Autochanger Move Error Codes B-29 Jukebox Micro-Move Error Codes B-32 Diagnostic Tests B-40 C. Micro/Macro-Moves HP Surestore Optical Micro-Move IDs D-2 E. Drive 3-74 A. Disconnect Timeout Settings Disconnect Timeouts E-2 ix Contents Element Type Code 1H - Storage Slot 3-71...
... Format for Error Recovery For all models, EXCEPT 40fx and 80ex B-8 Hardware Error Codes B-19 Autochanger Move Error Codes B-29 Jukebox Micro-Move Error Codes B-32 Diagnostic Tests B-40 C. Micro/Macro-Moves HP Surestore Optical Micro-Move IDs D-2 E. Drive 3-74 A. Disconnect Timeout Settings Disconnect Timeouts E-2 ix Contents Element Type Code 1H - Storage Slot 3-71...
Optical Drive and Library SCSI-2 Command Reference
Page 19
... Codes B-32 Table B-11. Autochanger Move Error Codes B-29 Table B-10. Jukebox FRUs (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx D-2 Table D-2. Jukebox FRUs (For the 40fx, 80ex, 125ex and 220mx models C-4 Table D-1. Hardware Error Codes (For the 40fx, 80ex, 125ex, and 220mx models B-22 Table B-9. HP Surestore Optical Micro-Move ID Table (For models 40fx, 80ex...
... Codes B-32 Table B-11. Autochanger Move Error Codes B-29 Table B-10. Jukebox FRUs (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx D-2 Table D-2. Jukebox FRUs (For the 40fx, 80ex, 125ex and 220mx models C-4 Table D-1. Hardware Error Codes (For the 40fx, 80ex, 125ex, and 220mx models B-22 Table B-9. HP Surestore Optical Micro-Move ID Table (For models 40fx, 80ex...
Optical Drive and Library SCSI-2 Command Reference
Page 347
Micro/Macro-Moves HP Surestore Optical Micro-Move IDs Table D-1 HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) 0 Vertical idle. 1 Move picker transport up to the top of the jukebox, checking for resistance. Fast... into a drive. Used in the vertical find home sequence. 5 Move a small amount upward, to the bottom of the jukebox, checking for resistance. Used in vertical find home sequence. 9 Move picker transport to relieve tension in the vertical find home ...
Micro/Macro-Moves HP Surestore Optical Micro-Move IDs Table D-1 HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) 0 Vertical idle. 1 Move picker transport up to the top of the jukebox, checking for resistance. Fast... into a drive. Used in the vertical find home sequence. 5 Move a small amount upward, to the bottom of the jukebox, checking for resistance. Used in vertical find home sequence. 9 Move picker transport to relieve tension in the vertical find home ...
Optical Drive and Library SCSI-2 Command Reference
Page 348
... the flip clear area (determined in the plunge find home sequence. 12 Move slowly down . Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) E Vertical put mail duck (not used ). 11 Move slowly up . F Vertical saturate...
... the flip clear area (determined in the plunge find home sequence. 12 Move slowly down . Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) E Vertical put mail duck (not used ). 11 Move slowly up . F Vertical saturate...
Optical Drive and Library SCSI-2 Command Reference
Page 349
... on the picker all the way back and flip the picker at the same time. Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) 32 Translate idle. 33 Translate and saturate right. 34 Translate and saturate...
... on the picker all the way back and flip the picker at the same time. Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) 32 Translate idle. 33 Translate and saturate right. 34 Translate and saturate...
Optical Drive and Library SCSI-2 Command Reference
Page 350
.... 73 Plunge put magazine out 2 (not used). 74 Plunge put "). Appendix D D-5 Micro/Macro-Moves Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) 6A Retract the plunge assembly on the picker all the way in the...
.... 73 Plunge put magazine out 2 (not used). 74 Plunge put "). Appendix D D-5 Micro/Macro-Moves Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) 6A Retract the plunge assembly on the picker all the way in the...
Optical Drive and Library SCSI-2 Command Reference
Page 351
... used ). 7C (Used in an emergency cartridge eject). D-6 Appendix D Plunge to the drive. Slow. Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) 76 First time "put" plunge into drive. Assembly is in position in an...
... used ). 7C (Used in an emergency cartridge eject). D-6 Appendix D Plunge to the drive. Slow. Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) 76 First time "put" plunge into drive. Assembly is in position in an...
Optical Drive and Library SCSI-2 Command Reference
Page 352
... picker. Used in error recovery. Either this is interpreted as a cartridge in the drive. Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) 83 Flip during plunge when cartridge is in the top picker. 84 Flip...
... picker. Used in error recovery. Either this is interpreted as a cartridge in the drive. Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) 83 Flip during plunge when cartridge is in the top picker. 84 Flip...
Optical Drive and Library SCSI-2 Command Reference
Page 353
D-8 Appendix D Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) 8E Move picker plunge assembly out to rearm the picker mechanism before switching active picker. 8F Retract picker plunge ...
D-8 Appendix D Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) 8E Move picker plunge assembly out to rearm the picker mechanism before switching active picker. 8F Retract picker plunge ...
Optical Drive and Library SCSI-2 Command Reference
Page 354
... Next part of a two-step move A6. Done after a small vertical movement is done. Retract assembly almost all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) A0 Plunge finish home (not used ). A6 Second part of move is done before the second part of... to a position where the current active picker can be read . A9 Move to "wiggle" the picker. Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all the way back. A1 Plunge finish saturate home (not used ). Is an attempt to switch the active...
... Next part of a two-step move A6. Done after a small vertical movement is done. Retract assembly almost all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) A0 Plunge finish home (not used ). A6 Second part of move is done before the second part of... to a position where the current active picker can be read . A9 Move to "wiggle" the picker. Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all the way back. A1 Plunge finish saturate home (not used ). Is an attempt to switch the active...
Optical Drive and Library SCSI-2 Command Reference
Page 355
Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) AB Move picker plunge assembly forward a small amount to complete the rearm of two moves to move the thumb ...
Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) AB Move picker plunge assembly forward a small amount to complete the rearm of two moves to move the thumb ...
Optical Drive and Library SCSI-2 Command Reference
Page 356
... the cartridge fully into the magazine after contacting, grabbing, and replacing the first cartridge. Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) B3 Retract picker plunge assembly back far enough to release the thumbs and...
... the cartridge fully into the magazine after contacting, grabbing, and replacing the first cartridge. Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) B3 Retract picker plunge assembly back far enough to release the thumbs and...
Optical Drive and Library SCSI-2 Command Reference
Page 357
... picker plunge assembly after an emergency eject during an ISTAT. Distance has not been learned. Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) BA First of two moves to test for media in picker. Part...
... picker plunge assembly after an emergency eject during an ISTAT. Distance has not been learned. Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) BA First of two moves to test for media in picker. Part...
Optical Drive and Library SCSI-2 Command Reference
Page 358
... return a cartridge into a drive. Distance has not been learned. Appendix D D-13 Micro/Macro-Moves Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) C4 Insert cartridge fully into a drive. Used in error recovery. Distance has been...
... return a cartridge into a drive. Distance has not been learned. Appendix D D-13 Micro/Macro-Moves Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) C4 Insert cartridge fully into a drive. Used in error recovery. Distance has been...
Optical Drive and Library SCSI-2 Command Reference
Page 359
... path. D9 Plunge to a position where the mailslot rotation actuator can by pushed out. Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all the way to mailslot insertion position. Ducks under the mailslot rotation mechanism and positions... the picker so it can move up all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) CE ...
... path. D9 Plunge to a position where the mailslot rotation actuator can by pushed out. Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all the way to mailslot insertion position. Ducks under the mailslot rotation mechanism and positions... the picker so it can move up all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) CE ...
Optical Drive and Library SCSI-2 Command Reference
Page 360
...rotating the mailslot out. E5 Short plunge out, feeling for 80fx, 160fx, 200fx, 160ex, 320ex, 400ex, 300mx, 600mx, and 700mx model jukeboxes. Appendix D D-15 Micro/Macro-Moves Checks that the mailslot has been rotated fully in. Followed by micro-move of a rotate in. ...all the way out. E1 First of the mailslot is felt. Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) DA Move picker plunge assembly to a position where the...
...rotating the mailslot out. E5 Short plunge out, feeling for 80fx, 160fx, 200fx, 160ex, 320ex, 400ex, 300mx, 600mx, and 700mx model jukeboxes. Appendix D D-15 Micro/Macro-Moves Checks that the mailslot has been rotated fully in. Followed by micro-move of a rotate in. ...all the way out. E1 First of the mailslot is felt. Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) DA Move picker plunge assembly to a position where the...
Optical Drive and Library SCSI-2 Command Reference
Page 361
... only for all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) E6 Retract picker plunge assembly a short distance to check media present/media inserted correctly. D-16 Appendix D Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all model jukeboxes. The following move in one direction on...motion in the plunge motor. E8 On powerup, testing for motion in or move IDs are for 330fx, 600fx, 660ex, 1200ex, 1200mx and 2200mx model jukeboxes. Used when path is blocked during powerup.
... only for all models, EXCEPT 40fx, 80ex, 125ex and 220mx) Move ID Description (hex.) E6 Retract picker plunge assembly a short distance to check media present/media inserted correctly. D-16 Appendix D Table D-1 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For all model jukeboxes. The following move in one direction on...motion in the plunge motor. E8 On powerup, testing for motion in or move IDs are for 330fx, 600fx, 660ex, 1200ex, 1200mx and 2200mx model jukeboxes. Used when path is blocked during powerup.
Optical Drive and Library SCSI-2 Command Reference
Page 362
Table D-2 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For models 40fx, 80ex, 125ex and 220mx ONLY) Move ID Description (hex.) 0 No motion; full speed (toward storage slot with intent to grab cartridge Micro/Macro-Moves Appendix D D-17 move ...
Table D-2 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For models 40fx, 80ex, 125ex and 220mx ONLY) Move ID Description (hex.) 0 No motion; full speed (toward storage slot with intent to grab cartridge Micro/Macro-Moves Appendix D D-17 move ...
Optical Drive and Library SCSI-2 Command Reference
Page 363
Table D-2 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For models 40fx, 80ex, 125ex and 220mx ONLY) Move ID Description (hex.) 12 Detect cartridge in storage slot before grabbing the cartridge 14 Pull cartridge back from storage slot 15 ...
Table D-2 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For models 40fx, 80ex, 125ex and 220mx ONLY) Move ID Description (hex.) 12 Detect cartridge in storage slot before grabbing the cartridge 14 Pull cartridge back from storage slot 15 ...
Optical Drive and Library SCSI-2 Command Reference
Page 364
Table D-2 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For models 40fx, 80ex, 125ex and 220mx ONLY) Move ID Description (hex.) 24 Detect cartridge in mailslot before grab 25 Take up the slack in the fingers before grabbing the ...
Table D-2 Micro/Macro-Moves HP Surestore Optical Micro-Move IDs HP Surestore Optical Micro-Move ID Table (For models 40fx, 80ex, 125ex and 220mx ONLY) Move ID Description (hex.) 24 Detect cartridge in mailslot before grab 25 Take up the slack in the fingers before grabbing the ...