Optical Drive and Library SCSI-2 Command Reference - Page 10
... HP Surestore Optical Micro-Move IDs D-2
E. Autochanger Error Codes Chapter Overview B-2 Request Sense Error Codes B-3 Additional Sense Data Format for Error Recovery For all models, EXCEPT 40fx and 80ex B-8 Hardware Error Codes B-19 Autochanger Move Error Codes B-29 Jukebox Micro-Move Error Codes B-32 Diagnostic Tests B-40
C. Picker 3-70 Element Type Code 2H - Field Replaceable...
Optical Drive and Library SCSI-2 Command Reference - Page 15
... CDB 2-134 Table 2-125. Read Defect Data Defect List Header 2-143
xiv Read Long Command CDB 2-104 Table 2-96. Supported Log Pages 00H 2-112 Table 2-103. Error Counter Page for Erase Errors 2-120 Table 2-114. Error Counter Page for Byte 8 of the Log Select Command 2-110 Table 2-99. Verify (Group 5) CDB 2-140 Table 2-127...
Optical Drive and Library SCSI-2 Command Reference - Page 19
... Tests (EXCEPT for models 40fx, 80ex, 125ex, and 220mx B-40 Table B-13. HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex, and 220mx C-2 Table C-2. Jukebox FRUs (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx D-2 Table D-2. Hardware Error Codes (For the 40fx, 80ex, 125ex, and 220mx models B-22 Table B-9. Timeout Settings E-2
xviii
Optical Drive and Library SCSI-2 Command Reference - Page 48
...
8
Reserved (0)
9
Reserved (0)
10
Reserved (0)
11
Reserved (0)
12
Additional Sense Code
13
Additional Sense Code Qualifier
14
Reserved (0)
15 SKSV
Sense Key Specific Information
16
Sense Key Specific Information
17
Sense Key Specific Information
18
Internal Error Code (MSByte)
19
Internal Error Code
20
Internal Error Code
21
Internal Error Code (LSByte)
Chapter 2
2-11
Optical Drive and Library SCSI-2 Command Reference - Page 49
... 2-(Not Ready) and the Additional Sense Code/Additional Sense Code Qualifier is set to 04/04-(Logical Unit Not Ready, Format in Progress) and the SKSV bit is set . A Valid bit of an error occurring during a previous command that the Sense Key Specific Information is set to 1, the sense key specific field is defined in bytes, as determined...
Optical Drive and Library SCSI-2 Command Reference - Page 190
... allows the manual insertion or removal of Commands
Code (hex.)
Name
Description
Page Number
1DH
1EH
2BH
3BH 3CH 4DH A5H A6H
B8H
Send Diagnostic
Causes the library to the jukebox
Read Buffer Command
Reads data from the jukebox
Log Sense
Retrieves statistical information about the library.
Jukebox SCSI-2 Commands
Table 3-1
Jukebox SCSI-2 Command Set Numerical List...
Optical Drive and Library SCSI-2 Command Reference - Page 238
... Number
Time Stamp (MSByte)
Time Stamp
Time Stamp
Time Stamp (LSByte)
Chapter 3
3-51 Jukebox SCSI-2 Commands
Table 3-49 Table 3-50
Jukebox SCSI-2 Command Set Log Sense Command (4DH)
Error Logs Table Format (For 40fx, 80ex, 125ex and 220mx models ONLY)
Byte
Description
0
Page Code 30H
1
Reserved = 0
2-3
Number of bytes to follow
4-5
Current entry number (range 1 - 50...
Optical Drive and Library SCSI-2 Command Reference - Page 240
... log Total number of good moves since last hard error Total number of soft errors since last hard error Array of hard error
Chapter 3
3-53
Jukebox SCSI-2 Commands Move totals and the ten most recent hard errors are unrecoverable and generate a hardware error code. The Move Success Log is ONLY supported on page 3-47 with normal operation continuing after...
Optical Drive and Library SCSI-2 Command Reference - Page 279
...Error Codes Internal Error Codes
ODC Error Codes
Code (hex.)
Description
44
Cannot proceed with error correction because the syndrome
buffer was filled
45
Cannot correct the error...the error correction occurred
4E
Unexpected interrupt was detected in the ODC chip
4F
Unexpected firmware ... is set to 0 in the W/R/S
73
Undefined condition is set in the DTS, DLS command
7D
Setup command ...
Optical Drive and Library SCSI-2 Command Reference - Page 281
...Error Codes Internal Error Codes
ODC Error Codes
Code (hex.)
Description
44
Cannot proceed with error correction because the syndrome
buffer was filled
45
Cannot correct the error...the error correction occurred
4E
Unexpected interrupt was detected in the ODC chip
4F
Unexpected firmware ... is set to 0 in the W/R/S
73
Undefined condition is set in the DTS, DLS command
7D
Setup command ...
Optical Drive and Library SCSI-2 Command Reference - Page 302
... FRU
The third most likely cause of an error, but may not fix the associated problem. Appendix B
B-15 Hardware Error
Code
Determined by fault isolation, this error code indicates
the cause of the Hardware
Error Codes are in Table B-9 on page B-29. The values of the failure. Additional Sense Data (For models 40fx, 80ex, 125ex and 220mx ONLY)
Byte...
Optical Drive and Library SCSI-2 Command Reference - Page 306
...made), the unit will return a No Error status. Hardware Error Codes (medium and large models only)
Error Code (hex.)
Failure Description
01
ROM checksum error
02
Register error
03
Microprocessor error
04
Controlled area of an error, but may not fix the associated problem. If an error is broken or jammed beyond recovery without manual intervention), the Autochanger will be returned to...
Optical Drive and Library SCSI-2 Command Reference - Page 310
Autochanger Error Codes
Table B-8
Autochanger Error Codes Hardware Error Codes
Hardware Error Codes (For the 40fx, 80ex, 125ex, and 220mx models ONLY)
Error Code (hex.)
Failure Description
19
SCSI connector loopback error in DB1 or C/D
1A
SCSI connector loopback error in DB2 or MSG
1B
SCSI connector loopback error in DB3 or REQ
1C
SCSI connector loopback error in DB4 or ACK
1D
SCSI ...
Optical Drive and Library SCSI-2 Command Reference - Page 334
....
18 Speed Factor Setting Allows the setting of full
speed). Quarter Speed
Appendix B
B-47 Returns an error code #57H Invalid Configuration if there are no cartridges loaded into the unit. The
number provides 1/Parameter speed (e.g. Autochanger Error Codes
Autochanger Error Codes Jukebox Micro-Move Error Codes
Table B-13
Sequence Tests (For models 40fx, 80ex, 125ex...
Optical Drive and Library SCSI-2 Command Reference - Page 338
...autochanger requires a disk in the mailslot. The test passes if clearance is run by SCSI command, set Byte 1 to be empty.) The autochanger requires a disk in the mailslot. Appendix B
B-51 ...of the isolation process.
Autochanger Error Codes
Autochanger Error Codes Jukebox Micro-Move Error Codes
Table B-13
Sequence Tests (For models 40fx, 80ex, 125ex, and 220mx ONLY)
No.
HP Surestore 160fx Reviews
Do you have an experience with the HP Surestore 160fx that you would like to share?
Earn 750 points for your review!
We have not received any reviews for HP yet.
Earn 750 points for your review!