Popular HP Surestore 1200ex Manual Pages
Optical Drive and Library SCSI-2 Command Reference - Page 10
... A-2 Drive Request Sense Command Values A-3 Drive Request Sense - Field Replaceable Units (FRUs) HP Field Replaceable Units (FRUs C-2
D. Mailslot 3-72 Element Type Code 4H - Sense Key Values A-3 Request Sense - Additional Sense Code Values A-5 Internal Error Codes A-9 DSP Error Codes A-19
B. Micro/Macro-Moves HP Surestore Optical Micro-Move IDs D-2
E. Picker 3-70 Element Type...
Optical Drive and Library SCSI-2 Command Reference - Page 19
Tables
Table B-8. Micro-Move Error Codes B-32 Table B-11. HP Surestore Optical Micro-Move ID Table (For models 40fx, 80ex, 125ex and 220mx D-17 Table E-1. Timeout Settings E-2
xviii Diagnostic Tests (EXCEPT for models 40fx, 80ex, 125ex, and 220mx B-40 Table B-13. Jukebox FRUs (For the 40fx, 80ex, 125ex and 220mx models C-4 Table D-1. Hardware Error Codes (For the 40fx, 80ex, 125ex, and ...
Optical Drive and Library SCSI-2 Command Reference - Page 190
Jukebox SCSI-2 Commands
Table 3-1
Jukebox SCSI-2 Command Set Numerical List of Commands
Numerical List of the specified destination element.
Move Medium
Moves media between library elements. Position To Element
Positions the specified transport element in front of Commands
Code... Medium Removal
Prevents or allows the manual insertion or removal of the storage slots, mailslot, drives, ...
Optical Drive and Library SCSI-2 Command Reference - Page 240
... the Log Sense Command (4DH), Table 3-45 on page 3-53
Hard errors are unrecoverable and generate a hardware error code.
The Move Success Log is ONLY supported on the 40fx and 80ex models. Soft errors are recorded.
NOTE Table 3-51
NOTE Table 3-52
Jukebox SCSI-2 Command Set Log Sense Command (4DH)
Move Success Log Table Format
This log is...
Optical Drive and Library SCSI-2 Command Reference - Page 281
...Error Codes Internal Error Codes
ODC Error Codes
Code (hex.)
Description
44
Cannot proceed with error correction because the syndrome
buffer was filled
45
Cannot correct the error...the error correction occurred
4E
Unexpected interrupt was detected in the ODC chip
4F
Unexpected firmware ... is set to 0 in the W/R/S
73
Undefined condition is set in the DTS, DLS command
7D
Setup command ...
Optical Drive and Library SCSI-2 Command Reference - Page 302
.... Appendix B
B-15
Autochanger Error Codes
Autochanger Error Codes Additional Sense Data Format for the most likely Field Replacable Unit to be the cause of the failure. (See Table A-2 on page A-4.)
Third FRU
The third most likely cause of an error, but may not fix the associated problem. Hardware Error
Code
Determined by fault isolation, this error code indicates
the cause of...
Optical Drive and Library SCSI-2 Command Reference - Page 306
... of an error, but may not fix the associated problem. If an error is found (or if error recovery was made), the unit will return a No Error status. Hardware Error Codes (medium and large models only)
Error Code (hex.)
Failure Description
01
ROM checksum error
02
Register error
03
Microprocessor error
04
Controlled area of attempting to aide service in replacement priority.
It...
Optical Drive and Library SCSI-2 Command Reference - Page 310
Autochanger Error Codes
Table B-8
Autochanger Error Codes Hardware Error Codes
Hardware Error Codes (For the 40fx, 80ex, 125ex, and 220mx models ONLY)
Error Code (hex.)
Failure Description
19
SCSI connector loopback error in DB1 or C/D
1A
SCSI connector loopback error in DB2 or MSG
1B
SCSI connector loopback error in DB3 or REQ
1C
SCSI connector loopback error in DB4 or ACK
1D
SCSI ...
Optical Drive and Library SCSI-2 Command Reference - Page 334
... Codes
Autochanger Error Codes Jukebox Micro-Move Error Codes
Table B-13
Sequence Tests (For models 40fx, 80ex, 125ex, and 220mx ONLY)
No. Requires one loaded cartridge; drives must be run at quarter speed. The
number provides 1/Parameter speed (e.g. Quarter Speed
Appendix B
B-47 The speed factor determines
how fast the system moves the mechanics.
Half Speed
22 Set...
Optical Drive and Library SCSI-2 Command Reference - Page 338
...the UPS is not connected properly or if there is run by SCSI command, set Byte 1 to the magazine number. Calculates a min/max clearance for actual values...Error Codes Jukebox Micro-Move Error Codes
Table B-13
Sequence Tests (For models 40fx, 80ex, 125ex, and 220mx ONLY)
No. Tests 30, 31, 33, 35, 36, 40, and 50 are most likely to select the three (or fewer) FRUs which are executed as a part...
HP SureStore Optical Disk Jukeboxes User's Guide - C1104-90015 - Page 4
In This Manual
This user's guide includes:
Chapter 1
set-up information for the HP SureStore Optical 80ex optical jukebox
Chapter 2
information about choosing and using optical disks
Chapter 3
features description, operating instructions, and troubleshooting information
Appendix A
supplies and customer support
Appendix B
operating this jukebox on a SCSI bus
Appendix C
safety and ...
HP SureStore Optical Disk Jukeboxes User's Guide - C1104-90015 - Page 61
If the configuration is set to change the security code, see "Changing the Administration Menu Password" in this chapter. Used by service personnel only. Toggles between ON and OFF. the OFF configuration disables the vertical sensors. Allows you to ON during normal operation. Should be set to OFF, the jukebox runs with dual picker (disk transport) addressing...
HP SureStore Optical Disk Jukeboxes User's Guide - C1104-90015 - Page 75
...; any jukebox driver separate from your jukebox application software and the
version of your host computer SCSI adapter • jukebox application software you can take when problems occur during operation.
If these procedures do not correct the problem, check the HP web site at www.hp.com/isgsupport/optical/index.html and the other support services listed in this driver
For problems that...
HP SureStore Optical Disk Jukeboxes User's Guide - C1104-90015 - Page 77
... can cause data loss and/or problems with the SCSI interface.
Operating the Jukebox
Operating the Jukebox Troubleshooting
Problem
What to do
No display messages.
• Ensure that the power cord is connected. • Ensure that the SCSI bus is inactive and restart your service representative. Disk inserted in this setting. See "Setting an Operating Configuration" in the...
HP SureStore Optical Disk Jukeboxes User's Guide - C1104-90015 - Page 79
... "Setting an Operating Configuration" in the jukebox. The current administration password is not an error. Select EJECT *, select the slot you chose before attempting another eject. Disk eject attempted but SOURCE NOW EMPTY displays.
Removing power to replace the disk into the slot before your host and application documentation for the application to a device on...