HP Surestore 400ex - Optical Jukebox Support and Manuals
Get Help and Manuals for this Hewlett-Packard item
This item is in your list!
View All Support Options Below
Free HP Surestore 400ex manuals!
Problems with HP Surestore 400ex?
Ask a Question
Free HP Surestore 400ex manuals!
Problems with HP Surestore 400ex?
Ask a Question
Popular HP Surestore 400ex Manual Pages
Optical Drive and Library SCSI-2 Command Reference - Page 10
... A-3 Drive Request Sense - Field Replaceable Units (FRUs) HP Field Replaceable Units (FRUs C-2
D. Additional Sense Code Values A-5 Internal Error Codes A-9 DSP Error Codes A-19
B. Storage Slot 3-71 Element Type Code 3H - Disconnect Timeout Settings Disconnect Timeouts E-2
ix Mailslot 3-72 Element Type Code 4H - Micro/Macro-Moves HP Surestore Optical Micro-Move IDs D-2
E. Sense...
Optical Drive and Library SCSI-2 Command Reference - Page 19
... Error Codes B-32 Table B-11. Jukebox FRUs (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx D-2 Table D-2. HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex, and 220mx C-2 Table C-2. Timeout Settings E-2
xviii Micro-Move Error Codes (For the 40fx, 80ex, 125ex, and 220mx models B-32 Table B-12. HP Surestore Optical Micro-Move ID Table (For models...
Optical Drive and Library SCSI-2 Command Reference - Page 190
...SCSI-2 Commands
Table 3-1
Jukebox SCSI-2 Command Set Numerical List of Commands
Numerical List of the specified destination element.
Write Buffer Command
Writes data to perform predefined diagnostic test/exerciser routines. Move Medium
Moves media between library elements. Position To Element
Positions the specified transport element in front of Commands
Code (hex.)
Name
Description...
Optical Drive and Library SCSI-2 Command Reference - Page 240
... via the Log Sense Command (4DH), Table 3-45 on the 40fx and 80ex models.
Move totals and the ten most recent hard errors are recoverable with page code 31H. Soft errors are recorded.
NOTE Table 3-51
NOTE Table 3-52
Jukebox SCSI-2 Command Set Log Sense Command (4DH)
Move Success Log Table Format
This log is intended...
Optical Drive and Library SCSI-2 Command Reference - Page 279
...Error Codes Internal Error Codes
ODC Error Codes
Code (hex.)
Description
44
Cannot proceed with error correction because the syndrome
buffer was filled
45
Cannot correct the error...the error correction occurred
4E
Unexpected interrupt was detected in the ODC chip
4F
Unexpected firmware ... is set to 0 in the W/R/S
73
Undefined condition is set in the DTS, DLS command
7D
Setup command ...
Optical Drive and Library SCSI-2 Command Reference - Page 281
...Error Codes Internal Error Codes
ODC Error Codes
Code (hex.)
Description
44
Cannot proceed with error correction because the syndrome
buffer was filled
45
Cannot correct the error...the error correction occurred
4E
Unexpected interrupt was detected in the ODC chip
4F
Unexpected firmware ... is set to 0 in the W/R/S
73
Undefined condition is set in the DTS, DLS command
7D
Setup command ...
Optical Drive and Library SCSI-2 Command Reference - Page 302
... Horizontal Motor Actual Position
73-77 Reserved (0)
Move Error Code
The movement that was being performed when the error occurred. Autochanger Error Codes
Autochanger Error Codes Additional Sense Data Format for the most likely Field Replacable Unit to be the actual cause of a problem.
Additional Sense Data (For models 40fx, 80ex, 125ex and 220mx ONLY)
Byte 7
6
5
4
3
2
1
0
47...
Optical Drive and Library SCSI-2 Command Reference - Page 306
... FRU that performs a process of elimination for the most likely cause of an error, but may not fix the associated problem. Hardware Error Codes (medium and large models only)
Error Code (hex.)
Failure Description
01
ROM checksum error
02
Register error
03
Microprocessor error
04
Controlled area of RAM checksum error
05
RAM test error
06
SCSI chip error
07
Jukebox controller chip...
Optical Drive and Library SCSI-2 Command Reference - Page 310
Autochanger Error Codes
Table B-8
Autochanger Error Codes Hardware Error Codes
Hardware Error Codes (For the 40fx, 80ex, 125ex, and 220mx models ONLY)
Error Code (hex.)
Failure Description
19
SCSI connector loopback error in DB1 or C/D
1A
SCSI connector loopback error in DB2 or MSG
1B
SCSI connector loopback error in DB3 or REQ
1C
SCSI connector loopback error in DB4 or ACK
1D
SCSI ...
Optical Drive and Library SCSI-2 Command Reference - Page 334
... zeros.
Quarter Speed
Appendix B
B-47 Autochanger Error Codes
Autochanger Error Codes Jukebox Micro-Move Error Codes
Table B-13
Sequence Tests (For models 40fx, 80ex, 125ex, and 220mx ONLY)
No. It does this once for each optical drive. It moves a cartridge from a randomlychosen full slot to the mailslot with a pass/fail result. Log
20 Set Speed Factor to Allows the mechanics...
Optical Drive and Library SCSI-2 Command Reference - Page 338
...tests are executed to select the three (or fewer) FRUs which are executed as a part of the isolation process. The test passes if clearance is 85 encoder counts (1 mm)...UPS is no UPS connected. Appendix B
B-51
Autochanger Error Codes
Autochanger Error Codes Jukebox Micro-Move Error Codes
Table B-13
Sequence Tests (For models 40fx, 80ex, 125ex, and 220mx ONLY)
No. Calculates a min/max...
HP SureStore Optical Disk Jukeboxes User's Guide - C1160-90015 - Page 4
In This Manual
This user's guide includes:
Chapter 1
set-up information for the HP SureStore Optical 80ex optical jukebox
Chapter 2
information about choosing and using optical disks
Chapter 3
features description, operating instructions, and troubleshooting information
Appendix A
supplies and customer support
Appendix B
operating this jukebox on a SCSI bus
Appendix C
safety and ...
HP SureStore Optical Disk Jukeboxes User's Guide - C1160-90015 - Page 67
... computer • brand and model of your host computer SCSI adapter • jukebox application software you can take when problems occur during operation. If these procedures do not correct the problem, check the HP web site at www.hp.com/isgsupport/optical/index.html and the other support services listed in this troubleshooting section. To troubleshoot problems, first refer to that may...
HP SureStore Optical Disk Jukeboxes User's Guide - C1160-90015 - Page 69
... Jukebox
Operating the Jukebox Troubleshooting
Problem
What to a device on the front panel is orange, cycle power to the jukebox.* Try to load the disk again when READY displays.
• If the disk is in the mailslot correctly and these error messages repeat, call your service representative. Chapter 3
3-35 See "Loading an Optical Disk into the Jukebox" in this setting...
HP SureStore Optical Disk Jukeboxes User's Guide - C1160-90015 - Page 71
...setting See "Setting an Operating Configuration" in the jukebox.
You want the disk ejected from again, and eject the disk. Removing power to replace the disk into the slot before your service... the Jukebox
Operating the Jukebox Troubleshooting
Problem
What to do
Disk eject attempted but empty and then EJECT * displays. The current administration password is not an error.
There...
HP Surestore 400ex Reviews
Do you have an experience with the HP Surestore 400ex that you would like to share?
Earn 750 points for your review!
We have not received any reviews for HP yet.
Earn 750 points for your review!