HP Surestore 80fx - Optical Jukebox Support and Manuals

Get Help and Manuals for this Hewlett-Packard item

View All Support Options Below
Free HP Surestore 80fx manuals!
Problems with HP Surestore 80fx?

Ask a Question

Popular HP Surestore 80fx Manual Pages

Optical Drive and Library SCSI-2 Command Reference - Page 10

... Error Codes A-9 DSP Error Codes A-19 B. Autochanger Error Codes Chapter Overview B-2 Request Sense Error Codes B-3 Additional Sense Data Format for Error Recovery For all models, EXCEPT 40fx and 80ex B-8 Hardware Error Codes B-19 Autochanger Move Error Codes B-29 Jukebox Micro-Move Error Codes B-32 Diagnostic Tests B-40 C. Drive 3-74 A. Micro/Macro-Moves HP Surestore Optical...
Optical Drive and Library SCSI-2 Command Reference - Page 19

..., 125ex and 220mx D-17 Table E-1. HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex, and 220mx C-2 Table C-2. Micro-Move Error Codes B-32 Table B-11. Sequence Tests (For models 40fx, 80ex, 125ex, and 220mx B-44 Table C-1. Jukebox FRUs (For the 40fx, 80ex, 125ex and 220mx models C-4 Table D-1. Hardware Error Codes (For the 40fx, 80ex, 125ex, and...
Optical Drive and Library SCSI-2 Command Reference - Page 48

... 8 Reserved (0) 9 Reserved (0) 10 Reserved (0) 11 Reserved (0) 12 Additional Sense Code 13 Additional Sense Code Qualifier 14 Reserved (0) 15 SKSV Sense Key Specific Information 16 Sense Key Specific Information 17 Sense Key Specific Information 18 Internal Error Code (MSByte) 19 Internal Error Code 20 Internal Error Code 21 Internal Error Code (LSByte) Chapter 2 2-11
Optical Drive and Library SCSI-2 Command Reference - Page 158

... SCSI-2 Drive Command Set Log Sense Command (4DH) Table 2-115 Parameter Codes/Structure for all pages Chapter 2 2-121 Code Length Bytes Description 1 12 Sectors Corrected with Retries 2 12 Total Number of Retry Attempts 3 12 Total Sectors Corrected 5 14 Total Bytes Processed 6 12 Total Number of Uncorrectable Sectors 0 46 Request for Blank Check Errors Param.
Optical Drive and Library SCSI-2 Command Reference - Page 190

... Diagnostic Causes the library to the jukebox Read Buffer Command Reads data from the jukebox Log Sense Retrieves statistical information about the library. Jukebox SCSI-2 Commands Table 3-1 Jukebox SCSI-2 Command Set Numerical List of Commands Numerical List of the specified destination element. Prevent/Allow Medium Removal Prevents or allows the manual insertion or removal of the...
Optical Drive and Library SCSI-2 Command Reference - Page 192

... to determine if the optical library is vendor unique and should always be set to successfully complete a command. Jukebox SCSI-2 Commands Table 3-2 NOTE Jukebox SCSI-2 Command Set Alphabetical List of Commands Alphabetical List of Commands Code (hex.) Name Description ... for use by a single SCSI initiator. Determines a specific error condition when the library fails to 0.
Optical Drive and Library SCSI-2 Command Reference - Page 238

... Number Time Stamp (MSByte) Time Stamp Time Stamp Time Stamp (LSByte) Chapter 3 3-51 Jukebox SCSI-2 Commands Table 3-49 Table 3-50 Jukebox SCSI-2 Command Set Log Sense Command (4DH) Error Logs Table Format (For 40fx, 80ex, 125ex and 220mx models ONLY) Byte Description 0 Page Code 30H 1 Reserved = 0 2-3 Number of bytes to follow 4-5 Current entry number (range 1 - 50...
Optical Drive and Library SCSI-2 Command Reference - Page 240

... Recovery Count at time of 10 entries, one entry per hard error (Table 3-52 on the 40fx and 80ex models. Move totals and the ten most recent hard errors are recoverable with page code 31H. NOTE Table 3-51 NOTE Table 3-52 Jukebox SCSI-2 Command Set Log Sense Command (4DH) Move Success Log Table Format This log...
Optical Drive and Library SCSI-2 Command Reference - Page 279

...Error Codes Internal Error Codes ODC Error Codes Code (hex.) Description 44 Cannot proceed with error correction because the syndrome buffer was filled 45 Cannot correct the error...the error correction occurred 4E Unexpected interrupt was detected in the ODC chip 4F Unexpected firmware ... is set to 0 in the W/R/S 73 Undefined condition is set in the DTS, DLS command 7D Setup command ...
Optical Drive and Library SCSI-2 Command Reference - Page 281

...Error Codes Internal Error Codes ODC Error Codes Code (hex.) Description 44 Cannot proceed with error correction because the syndrome buffer was filled 45 Cannot correct the error...the error correction occurred 4E Unexpected interrupt was detected in the ODC chip 4F Unexpected firmware ... is set to 0 in the W/R/S 73 Undefined condition is set in the DTS, DLS command 7D Setup command ...
Optical Drive and Library SCSI-2 Command Reference - Page 302

... may not fix the associated problem. Hardware Error Code Determined by fault isolation, this error code indicates the cause of the Hardware Error Codes are in Table B-8 on page A-4.) NOTE The FRU numbers returned are indicators for Error Recovery Table B-6 Request Sense - The values of the failure. First FRU The most likely Field Replacable Unit to be the cause...
Optical Drive and Library SCSI-2 Command Reference - Page 306

... or jammed beyond recovery without manual intervention), the Autochanger will return a No Error status. Up to three FRUs will be the actual cause of a problem. It attempts to isolate the error to aide service in replacement priority. Autochanger Error Codes Hardware Error Codes Autochanger Error Codes NOTE Table B-7 Hardware Error Codes Hardware Errors are indicators for various...
Optical Drive and Library SCSI-2 Command Reference - Page 310

Autochanger Error Codes Table B-8 Autochanger Error Codes Hardware Error Codes Hardware Error Codes (For the 40fx, 80ex, 125ex, and 220mx models ONLY) Error Code (hex.) Failure Description 19 SCSI connector loopback error in DB1 or C/D 1A SCSI connector loopback error in DB2 or MSG 1B SCSI connector loopback error in DB3 or REQ 1C SCSI connector loopback error in DB4 or ACK 1D SCSI ...
Optical Drive and Library SCSI-2 Command Reference - Page 334

...run at half speed. Log 20 Set Speed Factor to Allows the mechanics to all zeros. Half Speed 22 Set Speed Factor to Allows the mechanics ...optical drive. It then moves the cartridge back to the mailslot with a pass/fail result. The number provides 1/Parameter speed (e.g. Autochanger Error Codes Autochanger Error Codes Jukebox Micro-Move Error Codes Table B-13 Sequence Tests (For models...
Optical Drive and Library SCSI-2 Command Reference - Page 338

... Error Codes Jukebox Micro-Move Error Codes Table B-13 Sequence Tests (For models 40fx, 80ex, 125ex, and 220mx ONLY) No. Tests 30, 31, 33, 35, 36, 40, and 50 are executed as a part of special low-level tests are executed to select the three... not connected properly or if there is run by SCSI command, set Byte 1 to be empty.) The autochanger requires a disk in Test 65. Appendix B B-51

HP Surestore 80fx Reviews

Do you have an experience with the HP Surestore 80fx that you would like to share?
Earn 750 points for your review!
We have not received any reviews for HP yet.

Popular HP Surestore 80fx Search Terms

The following terms are frequently used to search for HP Surestore 80fx support:

Ask a New Question
Use the box below to post a new question about HP Surestore 80fx.
Manuals / Documents
Download any of our HP Surestore 80fx manuals for free!

We have the following 5 documents available for the HP Surestore 80fx:
  • Optical Drive and Library SCSI-2 Command Reference
  • 32/64/76 Slot, 5.2 Gbyte Drive Optical Jukebox Upgrade and Conversion Instructions - C1160-90018
  • HP StorageWorks Library and Tape Tools FAQ - Windows GUI Version
  • Adding 2 Drives to the C1150 Series Jukebox - C1154-90001
  • Capacity Upgrade For the C1150 Series Jukebox - C1155-90000

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

HP Manuals

Find free HP Surestore 80fx - Optical Jukebox manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

HP Reviews

View thousands of HP Surestore 80fx - Optical Jukebox user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete HP customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed HP customer service rankings, employee comments and much more from our sister site.

HP Recalls

Find comprehensive HP recall information updated hourly on RecallOwl.com.