Optical Drive and Library SCSI-2 Command Reference - Page 10

...A-5 Internal Error Codes A-9 DSP Error Codes A-19 B. Autochanger Error Codes Chapter Overview B-2 Request Sense Error Codes B-3 Additional Sense Data Format for Error Recovery For all models, EXCEPT 40fx and 80ex B-8 Hardware Error Codes B-19 Autochanger Move Error Codes B-29 Jukebox Micro-Move Error Codes B-32 Diagnostic Tests B-40 C. Micro/Macro-Moves HP Surestore Optical Micro-Move...
Optical Drive and Library SCSI-2 Command Reference - Page 15

... CDB 2-131 Table 2-124. Parameter Codes/Structure for Write Errors 02H 2-113 Table 2-104. Parameter Pointers/Structure for Blank Check Errors 34H 2-120 Table 2-115. Error Counter Page for Last N Error Events Page . . . . . 2-117 Table 2-111. Mode Sense Header 2-126 Table 2-121. Read (Group 5) Command CDB 2-128 Table 2-123. Supported Log Pages 00H 2-112 Table 2-103...
Optical Drive and Library SCSI-2 Command Reference - Page 19

... the 40fx, 80ex, 125ex, and 220mx models B-32 Table B-12. HP Surestore Optical Micro-Move ID Table (For models 40fx, 80ex, 125ex and 220mx D-17 Table E-1. Micro-Move Error Codes B-32 Table B-11. HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex, and 220mx C-2 Table C-2. Timeout Settings E-2 xviii Jukebox FRUs (For all models, EXCEPT 40fx, 80ex, 125ex and...
Optical Drive and Library SCSI-2 Command Reference - Page 48

... 8 Reserved (0) 9 Reserved (0) 10 Reserved (0) 11 Reserved (0) 12 Additional Sense Code 13 Additional Sense Code Qualifier 14 Reserved (0) 15 SKSV Sense Key Specific Information 16 Sense Key Specific Information 17 Sense Key Specific Information 18 Internal Error Code (MSByte) 19 Internal Error Code 20 Internal Error Code 21 Internal Error Code (LSByte) Chapter 2 2-11
Optical Drive and Library SCSI-2 Command Reference - Page 150

... Drive Commands SCSI-2 Drive Command Set Log Sense Command (4DH) Table 2-103 Table 2-104 Error Counter Page for Write Errors 02H Byte 7 6 5 4 3 2 1 0 0 Rsvd (0) Page Code (02H) 1 Reserved (0) 2 Page Length (n-3) (MSByte) 3 Page Length (n-3) (LSByte) 4 Parameter Code (MSByte) (See Table 2-104 on page 2-113 or Table 2-106 on page 2-114) 5 Parameter Code (LSByte) 6 Reserved...
Optical Drive and Library SCSI-2 Command Reference - Page 190

... allows the manual insertion or removal of Commands Code (hex.) Name Description Page Number 1DH 1EH 2BH 3BH 3CH 4DH A5H A6H B8H Send Diagnostic Causes the library to the jukebox Read Buffer Command Reads data from the jukebox Log Sense Retrieves statistical information about the library. Jukebox SCSI-2 Commands Table 3-1 Jukebox SCSI-2 Command Set Numerical List...
Optical Drive and Library SCSI-2 Command Reference - Page 238

... Number Time Stamp (MSByte) Time Stamp Time Stamp Time Stamp (LSByte) Chapter 3 3-51 Jukebox SCSI-2 Commands Table 3-49 Table 3-50 Jukebox SCSI-2 Command Set Log Sense Command (4DH) Error Logs Table Format (For 40fx, 80ex, 125ex and 220mx models ONLY) Byte Description 0 Page Code 30H 1 Reserved = 0 2-3 Number of bytes to follow 4-5 Current entry number (range 1 - 50...
Optical Drive and Library SCSI-2 Command Reference - Page 240

... number of good moves since last hard error Total number of soft errors since last hard error Array of hard error Chapter 3 3-53 Jukebox SCSI-2 Commands The Move Success Log is ONLY supported on page 3-47 with normal operation continuing after recovery. NOTE Table 3-51 NOTE Table 3-52 Jukebox SCSI-2 Command Set Log Sense Command (4DH) Move Success...
Optical Drive and Library SCSI-2 Command Reference - Page 279

...Error Codes Internal Error Codes ODC Error Codes Code (hex.) Description 44 Cannot proceed with error correction because the syndrome buffer was filled 45 Cannot correct the error...the error correction occurred 4E Unexpected interrupt was detected in the ODC chip 4F Unexpected firmware ... is set to 0 in the W/R/S 73 Undefined condition is set in the DTS, DLS command 7D Setup command ...
Optical Drive and Library SCSI-2 Command Reference - Page 281

...Error Codes Internal Error Codes ODC Error Codes Code (hex.) Description 44 Cannot proceed with error correction because the syndrome buffer was filled 45 Cannot correct the error...the error correction occurred 4E Unexpected interrupt was detected in the ODC chip 4F Unexpected firmware ... is set to 0 in the W/R/S 73 Undefined condition is set in the DTS, DLS command 7D Setup command ...
Optical Drive and Library SCSI-2 Command Reference - Page 302

... may not be the actual cause of a problem. Additional Sense Data (For models 40fx, 80ex, 125ex and 220mx ONLY) Byte 7 6 5 4 3 2 1 0 47-49 Reserved (0) 50-54 Micro-Move ID History (Table C-2 on page C-17) 55 Failed Micro-Move ID (Table C-2 on page C-17) 56 Micro-Move Error Code (Table B-11 on page B-22. The values...
Optical Drive and Library SCSI-2 Command Reference - Page 306

... and large models only) Error Code (hex.) Failure Description 01 ROM checksum error 02 Register error 03 Microprocessor error 04 Controlled area of an error, but may not fix the associated problem. Simply changing the FRU listed may or may not be returned to aide service in replacement priority. Autochanger Error Codes Hardware Error Codes Autochanger Error Codes NOTE...
Optical Drive and Library SCSI-2 Command Reference - Page 310

Autochanger Error Codes Table B-8 Autochanger Error Codes Hardware Error Codes Hardware Error Codes (For the 40fx, 80ex, 125ex, and 220mx models ONLY) Error Code (hex.) Failure Description 19 SCSI connector loopback error in DB1 or C/D 1A SCSI connector loopback error in DB2 or MSG 1B SCSI connector loopback error in DB3 or REQ 1C SCSI connector loopback error in DB4 or ACK 1D SCSI ...
Optical Drive and Library SCSI-2 Command Reference - Page 334

... to be run at full speed. It then moves the cartridge back to all zeros. Log 20 Set Speed Factor to Allows the mechanics to be empty. 17 Mailslot I /O Test Performs a combination of full speed). Autochanger Error Codes Autochanger Error Codes Jukebox Micro-Move Error Codes Table B-13 Sequence Tests (For models 40fx, 80ex, 125ex, and 220mx ONLY) No.
Optical Drive and Library SCSI-2 Command Reference - Page 338

The test passes if clearance is run by SCSI command, set Byte 1 to the magazine number. The test returns: PASS or... in the mailslot. Clears the value calculated in the mailslot. Appendix B B-51 Autochanger Error Codes Autochanger Error Codes Jukebox Micro-Move Error Codes Table B-13 Sequence Tests (For models 40fx, 80ex, 125ex, and 220mx ONLY) No. Tests 30, 31, 33, 35...

HP Surestore 600fx Reviews

Do you have an experience with the HP Surestore 600fx that you would like to share?
Earn 750 points for your review!
We have not received any reviews for HP yet.

Popular HP Surestore 600fx Search Terms

The following terms are frequently used to search for HP Surestore 600fx support:

Ask a New Question
Use the box below to post a new question about HP Surestore 600fx.
Manuals / Documents
Download any of our HP Surestore 600fx manuals for free!

We have the following 3 documents available for the HP Surestore 600fx:
  • Optical Drive and Library SCSI-2 Command Reference
  • HP StorageWorks Library and Tape Tools FAQ - Windows GUI Version
  • Adding 2 Drives to the C1107 Series Jukebox - C1158-90001

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

HP Manuals

Find free HP Surestore 600fx - Optical Jukebox manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

HP Reviews

View thousands of HP Surestore 600fx - Optical Jukebox user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete HP customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed HP customer service rankings, employee comments and much more from our sister site.

HP Recalls

Find comprehensive HP recall information updated hourly on RecallOwl.com.