Optical Drive and Library SCSI-2 Command Reference - Page 10
... Disconnect Timeout Settings Disconnect Timeouts E-2
ix Autochanger Error Codes Chapter Overview B-2 Request Sense Error Codes B-3 Additional Sense Data Format for Error Recovery For all models, EXCEPT 40fx and 80ex B-8 Hardware Error Codes B-19 Autochanger Move Error Codes B-29 Jukebox Micro-Move Error Codes B-32 Diagnostic Tests B-40
C. Micro/Macro-Moves HP Surestore Optical Micro-Move...
Optical Drive and Library SCSI-2 Command Reference - Page 19
..., 80ex, 125ex, and 220mx B-44 Table C-1. HP Surestore Optical Micro-Move ID Table (For all models, EXCEPT 40fx, 80ex, 125ex, and 220mx C-2 Table C-2. Autochanger Move Error Codes B-29 Table B-10. Diagnostic Tests (EXCEPT for models 40fx, 80ex, 125ex, and 220mx B-40 Table B-13. Micro-Move Error Codes B-32 Table B-11. Jukebox FRUs (For all models, EXCEPT 40fx, 80ex, 125ex and 220mx...
Optical Drive and Library SCSI-2 Command Reference - Page 48
...
8
Reserved (0)
9
Reserved (0)
10
Reserved (0)
11
Reserved (0)
12
Additional Sense Code
13
Additional Sense Code Qualifier
14
Reserved (0)
15 SKSV
Sense Key Specific Information
16
Sense Key Specific Information
17
Sense Key Specific Information
18
Internal Error Code (MSByte)
19
Internal Error Code
20
Internal Error Code
21
Internal Error Code (LSByte)
Chapter 2
2-11
Optical Drive and Library SCSI-2 Command Reference - Page 158
...
SCSI-2 Drive Command Set Log Sense Command (4DH)
Table 2-115
Parameter Codes/Structure for all pages
Chapter 2
2-121 Code
Length Bytes
Description
1
12
Sectors Corrected with Retries
2
12
Total Number of Retry Attempts
3
12
Total Sectors Corrected
5
14
Total Bytes Processed
6
12
Total Number of Uncorrectable Sectors
0
46
Request for Blank Check Errors
Param.
Optical Drive and Library SCSI-2 Command Reference - Page 190
... Removal
Prevents or allows the manual insertion or removal of the ...Jukebox SCSI-2 Command Set Numerical List of Commands
Numerical List of the specified destination element. Position To Element
Positions the specified transport element in front of Commands
Code (hex.)
Name
Description
Page Number
1DH
1EH
2BH
3BH 3CH 4DH A5H A6H
B8H
Send Diagnostic
Causes the library to the jukebox...
Optical Drive and Library SCSI-2 Command Reference - Page 192
... 3
3-5 Determines a specific error condition when the library fails to a specific predefined state. Checks to determine if the optical library is vendor unique and should always be set to perform predefined diagnostic test/ exerciser routines. Jukebox SCSI-2 Commands
Table 3-2 NOTE
Jukebox SCSI-2 Command Set Alphabetical List of Commands
Alphabetical List of Commands
Code (hex.)
Name...
Optical Drive and Library SCSI-2 Command Reference - Page 238
... Number
Time Stamp (MSByte)
Time Stamp
Time Stamp
Time Stamp (LSByte)
Chapter 3
3-51 Jukebox SCSI-2 Commands
Table 3-49 Table 3-50
Jukebox SCSI-2 Command Set Log Sense Command (4DH)
Error Logs Table Format (For 40fx, 80ex, 125ex and 220mx models ONLY)
Byte
Description
0
Page Code 30H
1
Reserved = 0
2-3
Number of bytes to follow
4-5
Current entry number (range 1 - 50...
Optical Drive and Library SCSI-2 Command Reference - Page 240
...
Page Code 31H Reserved = 0 Number of bytes to follow Current entry number (range 1 - 10) Number of entries in the log Total number of good moves since last hard error Total number of soft errors since last hard error Array of hard error
Chapter 3
3-53
Jukebox SCSI-2 Commands NOTE Table 3-51
NOTE Table 3-52
Jukebox SCSI-2 Command Set Log...
Optical Drive and Library SCSI-2 Command Reference - Page 279
...Error Codes Internal Error Codes
ODC Error Codes
Code (hex.)
Description
44
Cannot proceed with error correction because the syndrome
buffer was filled
45
Cannot correct the error...the error correction occurred
4E
Unexpected interrupt was detected in the ODC chip
4F
Unexpected firmware ... is set to 0 in the W/R/S
73
Undefined condition is set in the DTS, DLS command
7D
Setup command ...
Optical Drive and Library SCSI-2 Command Reference - Page 281
...Error Codes Internal Error Codes
ODC Error Codes
Code (hex.)
Description
44
Cannot proceed with error correction because the syndrome
buffer was filled
45
Cannot correct the error...the error correction occurred
4E
Unexpected interrupt was detected in the ODC chip
4F
Unexpected firmware ... is set to 0 in the W/R/S
73
Undefined condition is set in the DTS, DLS command
7D
Setup command ...
Optical Drive and Library SCSI-2 Command Reference - Page 302
Hardware Error
Code
Determined by fault isolation, this error code indicates
the cause of an error, but may not fix the associated problem.
Appendix B
B-15 Additional Sense Data (For models 40fx, ... Error Codes are indicators for Error Recovery
Table B-6
Request Sense - Autochanger Error Codes
Autochanger Error Codes Additional Sense Data Format for the most likely Field Replacable ...
Optical Drive and Library SCSI-2 Command Reference - Page 306
...of elimination for the most likely cause of an error, but may not fix the associated problem.
Autochanger Error Codes Hardware Error Codes
Autochanger Error Codes
NOTE Table B-7
Hardware Error Codes
Hardware Errors are indicators for various FRUs runs automatically. If no error can be returned to aide service in replacement priority.
The FRU numbers returned are reported through...
Optical Drive and Library SCSI-2 Command Reference - Page 310
Autochanger Error Codes
Table B-8
Autochanger Error Codes Hardware Error Codes
Hardware Error Codes (For the 40fx, 80ex, 125ex, and 220mx models ONLY)
Error Code (hex.)
Failure Description
19
SCSI connector loopback error in DB1 or C/D
1A
SCSI connector loopback error in DB2 or MSG
1B
SCSI connector loopback error in DB3 or REQ
1C
SCSI connector loopback error in DB4 or ACK
1D
SCSI ...
Optical Drive and Library SCSI-2 Command Reference - Page 334
... be run at half speed. Log
20 Set Speed Factor to Allows the mechanics to a drive, with a pass/fail result. It does this once for each optical drive. Quarter Speed
Appendix B
B-47 It...factor as the first
Utility
parameter given. Autochanger Error Codes
Autochanger Error Codes Jukebox Micro-Move Error Codes
Table B-13
Sequence Tests (For models 40fx, 80ex, 125ex, and 220mx ONLY)
No.
Optical Drive and Library SCSI-2 Command Reference - Page 338
...The test passes if clearance is run by SCSI command, set Byte 1 to the magazine number.
Tests whether or not ...the three (or fewer) FRUs which are executed as a part of the isolation process. The test passes if clearance is 85...returns: PASS or FAIL. Autochanger Error Codes
Autochanger Error Codes Jukebox Micro-Move Error Codes
Table B-13
Sequence Tests (For models 40fx, 80ex, 125ex, and ...
HP Surestore 200fx Reviews
Do you have an experience with the HP Surestore 200fx that you would like to share?
Earn 750 points for your review!
We have not received any reviews for HP yet.