Owner's Manual
Page 4
...SAFETY FEATURES Safe-T-Beam® (STB) Non-Contact Reversing System Puts an invisible beam across the door opening speed to the programming instructions on the door during the closing , if Safe-T-Beam® is detected for an Assembly/Installation Instructions poster, if ... opening . Lights automatically turn OFF after completing assembly and installation of opener. Refer to a desired rate, vary limits and force, and program new remotes. Contact your Genie® Professional Dealer for an installation poster, if needed , or call 1-800-35GENIE. INFRARED PROTECTION FUNCTION 1....
...SAFETY FEATURES Safe-T-Beam® (STB) Non-Contact Reversing System Puts an invisible beam across the door opening speed to the programming instructions on the door during the closing , if Safe-T-Beam® is detected for an Assembly/Installation Instructions poster, if ... opening . Lights automatically turn OFF after completing assembly and installation of opener. Refer to a desired rate, vary limits and force, and program new remotes. Contact your Genie® Professional Dealer for an installation poster, if needed , or call 1-800-35GENIE. INFRARED PROTECTION FUNCTION 1....
Owner's Manual
Page 5
... not require manually initiated changes. There are only 2 "required" programming processes you will want to program the opener so that your Genie garage door opener is only used to set up your garage door opener for operation: 1. "REMOTE PROGRAMMING" Term Definitions: Travel Limits programming allows you to set how far your door travels up and down...
... not require manually initiated changes. There are only 2 "required" programming processes you will want to program the opener so that your Genie garage door opener is only used to set up your garage door opener for operation: 1. "REMOTE PROGRAMMING" Term Definitions: Travel Limits programming allows you to set how far your door travels up and down...
Owner's Manual
Page 6
... 3 Release down arrow button (-) until the long LED comes on the Powerhead, you have 30 seconds to carriage, do so now. 3 Required Programming TRAVEL LIMITS WARNING • Make sure doorway is in view and clear of the step and start over. If not illuminated, check for 2 seconds until ... or the Sure-Lock switch may be engaged to property. • DO NOT operate this unit from wall console before LIMITS are set. PROGRAM PROGRAM SET + SET HOLD 2 seconds 6 PROGRAM SET + NOTE: You have run out of time and must go back to the beginning of obstacles and people to avoid...
... 3 Release down arrow button (-) until the long LED comes on the Powerhead, you have 30 seconds to carriage, do so now. 3 Required Programming TRAVEL LIMITS WARNING • Make sure doorway is in view and clear of the step and start over. If not illuminated, check for 2 seconds until ... or the Sure-Lock switch may be engaged to property. • DO NOT operate this unit from wall console before LIMITS are set. PROGRAM PROGRAM SET + SET HOLD 2 seconds 6 PROGRAM SET + NOTE: You have run out of time and must go back to the beginning of obstacles and people to avoid...
Owner's Manual
Page 7
... arrow button (+) for 2 seconds until door is fully open ) limit is programmed. PROGRAM PROGRAM - + ET G999-393 Manual-ScrewBeltChain-EN indd 7 The UP (open , then release. HOLD Opening Garage Door (Up Limits) NOTE: Beginning with powerhead. BOTH DOOR LIMITS ARE NOW PROGRAMMED. 7 7/13/12 10 17 AM PROGRAM SET - Watch carriage as it approaches the power head to...
... arrow button (+) for 2 seconds until door is fully open ) limit is programmed. PROGRAM PROGRAM - + ET G999-393 Manual-ScrewBeltChain-EN indd 7 The UP (open , then release. HOLD Opening Garage Door (Up Limits) NOTE: Beginning with powerhead. BOTH DOOR LIMITS ARE NOW PROGRAMMED. 7 7/13/12 10 17 AM PROGRAM SET - Watch carriage as it approaches the power head to...
Owner's Manual
Page 9
...NOTE: Force or Speed controls DO NOT require programming. Red LED lights on the Wall Console. Then repeat the WALL CONSOLE/Contact Reverse Test, steps 11-13. Force and Speed Limits are factory programmed and automatically set force limits. FORCE AND SPEED CONTROL ARE NOW SET. Contact... Reverse Test NOTE: The Limit and Force settings MUST BE COMPLETED before it should stop and reverse direction within...
...NOTE: Force or Speed controls DO NOT require programming. Red LED lights on the Wall Console. Then repeat the WALL CONSOLE/Contact Reverse Test, steps 11-13. Force and Speed Limits are factory programmed and automatically set force limits. FORCE AND SPEED CONTROL ARE NOW SET. Contact... Reverse Test NOTE: The Limit and Force settings MUST BE COMPLETED before it should stop and reverse direction within...
Owner's Manual
Page 17
...; Chain/belt drive models: Verify bullet is installed and Limits are not pinched or near moving parts. 1. Reset Open/Close Travel Limit Performing all eleven (11) Limits/Force setting steps (see pages 6-8) erases previous Limits/Force settings. Align components and snap case closed. (continued ...Operate door using a washer or coin that fits into the slot at top of no more than 100 Watt rating, PowerLift® 900, GPower™ 900 require light bulbs of remote. 2. Close powerhead light cover. 2. Replace battery. 3. Disengaging and Engaging Carriage/Bullet Screw...
...; Chain/belt drive models: Verify bullet is installed and Limits are not pinched or near moving parts. 1. Reset Open/Close Travel Limit Performing all eleven (11) Limits/Force setting steps (see pages 6-8) erases previous Limits/Force settings. Align components and snap case closed. (continued ...Operate door using a washer or coin that fits into the slot at top of no more than 100 Watt rating, PowerLift® 900, GPower™ 900 require light bulbs of remote. 2. Close powerhead light cover. 2. Replace battery. 3. Disengaging and Engaging Carriage/Bullet Screw...
Owner's Manual
Page 18
... CAUTION Door closing . 3. See page 8. Force Adjustment Action 1 Press and hold both BLUE FORCE Settings are reset. PROGRAM SET LED Indication/Result RED OFF BLUE OFF Flashes 3 Times The Current UP FORCE SETTING will display. Then the New DOWN...Force Settings Force settings are : 1. However, conditions possibly requiring adjustment are pre programmed at the factory and "learned" during the Open/Close Limit settings steps (see pages 6-7). SEE CHART IN NEXT COLUMN. PROGRAM SET 4 Press either until you reach desired setting. 3 Press and release. ...
... CAUTION Door closing . 3. See page 8. Force Adjustment Action 1 Press and hold both BLUE FORCE Settings are reset. PROGRAM SET LED Indication/Result RED OFF BLUE OFF Flashes 3 Times The Current UP FORCE SETTING will display. Then the New DOWN...Force Settings Force settings are : 1. However, conditions possibly requiring adjustment are pre programmed at the factory and "learned" during the Open/Close Limit settings steps (see pages 6-7). SEE CHART IN NEXT COLUMN. PROGRAM SET 4 Press either until you reach desired setting. 3 Press and release. ...
Owner's Manual
Page 19
... LONG LED ROUND LED RED RED PURPLE PURPLE BLUE BLUE Note: One-piece doors are automatically set to the slowest speed during Limits programming and cannot be positioned further away from door opening if necessary to avoid sunlight but no further off the wall to minimize wear...Place the Source (Red LED) Safe-T-Beams on the criteria mentioned above , you reach the desired setting. 7 Press and release. Note: PowerLift® 900, GPower™ 900 openers DO NOT have the option to confirm setting. Speed Adjustment Action 1 Press and hold for the opener can be affected by door ...
... LONG LED ROUND LED RED RED PURPLE PURPLE BLUE BLUE Note: One-piece doors are automatically set to the slowest speed during Limits programming and cannot be positioned further away from door opening if necessary to avoid sunlight but no further off the wall to minimize wear...Place the Source (Red LED) Safe-T-Beams on the criteria mentioned above , you reach the desired setting. 7 Press and release. Note: PowerLift® 900, GPower™ 900 openers DO NOT have the option to confirm setting. Speed Adjustment Action 1 Press and hold for the opener can be affected by door ...
Owner's Manual
Page 21
... stolen? See pages 6-7. • Be sure door, opener, and springs are properly set with the garage door hardware or springs, contact The Genie Company at garage door. • Replace battery. Sure-Lock™ should be set . Door opener starts for normal operation. no operation. ...Check closing "FORCE" adjustment. Call us: 800-354-3643 Problem What to powerhead. See page 17. • Program remote to do Opener does NOT run closed. • Check if limits are properly set . See pages 10-11. OR Safe-T-Beam® System malfunction. • If a NEW installation...
... stolen? See pages 6-7. • Be sure door, opener, and springs are properly set with the garage door hardware or springs, contact The Genie Company at garage door. • Replace battery. Sure-Lock™ should be set . Door opener starts for normal operation. no operation. ...Check closing "FORCE" adjustment. Call us: 800-354-3643 Problem What to powerhead. See page 17. • Program remote to do Opener does NOT run closed. • Check if limits are properly set . See pages 10-11. OR Safe-T-Beam® System malfunction. • If a NEW installation...
Owner's Manual
Page 22
...174; physical obstruction. Door contact in UP or DOWN travel is in good repair. Thermal cutout Program remote using instructions on a one -piece door. • Contact The Genie Company at 1-800-35GENIE concerning door speed. Remove obstruction. Check door spring, track, rollers, ... Possible Problem Normal operation. Remove obstruction, recheck unit. DO NOT unplug unit. Door component failure detected. Check power supply. Re-program limits, see page 19. Door opener runs slow. • Check operating condition of Safe-T-Beam® pair and nearest other Safe-T-...
...174; physical obstruction. Door contact in UP or DOWN travel is in good repair. Thermal cutout Program remote using instructions on a one -piece door. • Contact The Genie Company at 1-800-35GENIE concerning door speed. Remove obstruction. Check door spring, track, rollers, ... Possible Problem Normal operation. Remove obstruction, recheck unit. DO NOT unplug unit. Door component failure detected. Check power supply. Re-program limits, see page 19. Door opener runs slow. • Check operating condition of Safe-T-Beam® pair and nearest other Safe-T-...