Fluke 116 Digital Multimeter Datasheet
Page 1
... Data Actual size R N10140 Compact true-rms meter for HVAC troubleshooting The Fluke 116 was specifically designed for 1 year after calibration, at operating temperatures of reading ] + [ counts ] ) Maximum voltage between any terminal and earth ground Surge protection Display Bar graph Operating temperature Storage temperature Battery Battery life 600 V 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 Digital: 6,000 counts, updates 4/sec 33 segments, updates...
... Data Actual size R N10140 Compact true-rms meter for HVAC troubleshooting The Fluke 116 was specifically designed for 1 year after calibration, at operating temperatures of reading ] + [ counts ] ) Maximum voltage between any terminal and earth ground Surge protection Display Bar graph Operating temperature Storage temperature Battery Battery life 600 V 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 Digital: 6,000 counts, updates 4/sec 33 segments, updates...
Fluke 116 Digital Multimeter Datasheet
Page 2
...800)-36-FLUKE or Fax (905) 890-6866 From other true-rms meters to display non-zero readings when the test leads are dc-coupled. 2 Temperature uncertainty (accuracy) does not include the error of ≤ 3 at full scale. All rights reserved. Auto-V LoZ...holster, User's manual and 9V battery (installed). detects opens or shorts of range. Keeping your world up and running. AC volts is ac coupled, 5 Hz to 100 % of 500 µs or longer. 0.9 % + 2 0.9 % + 1 1.5 % + 2 0.9 % + 2 1.9 % + 2 1.9 % + 2 5 % + 20 10 % + 2 typical 1 % + 102 1 % + 182 Ordering information Fluke-116 HVAC ...
...800)-36-FLUKE or Fax (905) 890-6866 From other true-rms meters to display non-zero readings when the test leads are dc-coupled. 2 Temperature uncertainty (accuracy) does not include the error of ≤ 3 at full scale. All rights reserved. Auto-V LoZ...holster, User's manual and 9V battery (installed). detects opens or shorts of range. Keeping your world up and running. AC volts is ac coupled, 5 Hz to 100 % of 500 µs or longer. 0.9 % + 2 0.9 % + 1 1.5 % + 2 0.9 % + 2 1.9 % + 2 1.9 % + 2 5 % + 20 10 % + 2 typical 1 % + 102 1 % + 182 Ordering information Fluke-116 HVAC ...
Fluke 116 Users Manual
Page 2
... description of the problem. Fluke Europe B.V. LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for three years from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. THIS ... not cover fuses, disposable batteries, or damage from the date of purchase. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to you. 11/99 Fluke Corporation P.O. Resellers...
... description of the problem. Fluke Europe B.V. LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for three years from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. THIS ... not cover fuses, disposable batteries, or damage from the date of purchase. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to you. 11/99 Fluke Corporation P.O. Resellers...
Fluke 116 Users Manual
Page 3
... is displayed when the Meter measures a voltage ≥30 V or a voltage overload (OL) condition. True-rms Multimeter Introduction The Fluke Model 116, is unspecified. 1 Register your Meter at www.fluke.com. This meter meets ...CAT III IEC 61010-1 2nd Edition standards. The IEC 61010-1 2nd Edition safety standard defines four measurement categories (CAT I to the presence of danger from transient impulses. When making frequency measurements >1 kHz, the Y symbol is a battery-powered...
... is displayed when the Meter measures a voltage ≥30 V or a voltage overload (OL) condition. True-rms Multimeter Introduction The Fluke Model 116, is unspecified. 1 Register your Meter at www.fluke.com. This meter meets ...CAT III IEC 61010-1 2nd Edition standards. The IEC 61010-1 2nd Edition safety standard defines four measurement categories (CAT I to the presence of danger from transient impulses. When making frequency measurements >1 kHz, the Y symbol is a battery-powered...
Fluke 116 Users Manual
Page 4
116 Users Manual Safety Information A "XWWarning" statement identifies hazardous conditions and actions that could damage the Meter or the equipment under test. If in this manual or the protection provided by the Meter might be impaired. • Do not use the Meter or test leads if they appear damaged, or if the Meter is not operating properly. • Always use test leads that...
116 Users Manual Safety Information A "XWWarning" statement identifies hazardous conditions and actions that could damage the Meter or the equipment under test. If in this manual or the protection provided by the Meter might be impaired. • Do not use the Meter or test leads if they appear damaged, or if the Meter is not operating properly. • Always use test leads that...
Fluke 116 Users Manual
Page 5
... the replacement fuse specified or the protection may be impaired. • Check the test leads for disposal. 3 Contact Fluke or a qualified recycler for continuity before use the Auto Volts function to manual J Earth ground D AC and DC ~ Do not dispose of this function's low input impedance (≈3 kΩ). Symbols B AC (Alternating Current) N Battery (Low battery when shown on display.) F DC (Direct...
... the replacement fuse specified or the protection may be impaired. • Check the test leads for disposal. 3 Contact Fluke or a qualified recycler for continuity before use the Auto Volts function to manual J Earth ground D AC and DC ~ Do not dispose of this function's low input impedance (≈3 kΩ). Symbols B AC (Alternating Current) N Battery (Low battery when shown on display.) F DC (Direct...
Fluke 116 Users Manual
Page 6
116 Users Manual Display 5 4 3 2 1 14 13 6 12 15 7 9 8 10 11 16 eeo02f.eps No. B R The Meter function is set to Diode Test C O Input is set to Continuity. Display freezes present reading. 4 E K Display hold enabled. Measured input voltage ≥ 30 V, or voltage overload condition (OL). Symbol Meaning A s The Meter function is a negative value. D Y X Unsafe voltage.
116 Users Manual Display 5 4 3 2 1 14 13 6 12 15 7 9 8 10 11 16 eeo02f.eps No. B R The Meter function is set to Diode Test C O Input is set to Continuity. Display freezes present reading. 4 E K Display hold enabled. Measured input voltage ≥ 30 V, or voltage overload condition (OL). Symbol Meaning A s The Meter function is a negative value. D Y X Unsafe voltage.
Fluke 116 Users Manual
Page 7
... reading displayed G LoZ The Meter is selected. 5 H nµ°F°C mVµA MkΩ kHz Measurement units. L (Bar graph) Analog display. M Auto Volts The Meter is too large for best resolution. N + Bar graph polarity O 0L W The input is in the Auto Volts function. Symbol Meaning F M MIN MAX AVG mode enabled. I DC AC Direct current or alternating current J N Battery low warning. Auto Auto ranging. True...
... reading displayed G LoZ The Meter is selected. 5 H nµ°F°C mVµA MkΩ kHz Measurement units. L (Bar graph) Analog display. M Auto Volts The Meter is too large for best resolution. N + Bar graph polarity O 0L W The input is in the Auto Volts function. Symbol Meaning F M MIN MAX AVG mode enabled. I DC AC Direct current or alternating current J N Battery low warning. Auto Auto ranging. True...
Fluke 116 Users Manual
Page 8
Calibration required. Internal error. The Meter must be repaired before it will operate. B Input terminal for all measurements. bAtt CAL Err EEPr Err F11Err Error Messages Battery must be replaced before the Meter will operate. Meter calibration is required before the Meter will operate. The Meter must be repaired before it will operate. 6 116 Users Manual Terminals COM + 2 1 edy01f.eps No. Description A Common (return) terminal for measuring voltage, continuity, resistance...
Calibration required. Internal error. The Meter must be repaired before it will operate. B Input terminal for all measurements. bAtt CAL Err EEPr Err F11Err Error Messages Battery must be replaced before the Meter will operate. Meter calibration is required before the Meter will operate. The Meter must be repaired before it will operate. 6 116 Users Manual Terminals COM + 2 1 edy01f.eps No. Description A Common (return) terminal for measuring voltage, continuity, resistance...
Fluke 116 Users Manual
Page 10
.... Manual and Autoranging The Meter has both Manual and Autorange modes. • In the Autorange mode, the Meter selects the range with the best resolution. • In the Manual Range mode, you apply a different voltage. 116 Users Manual Battery Saver ("Sleep Mode") The Meter automatically enters "Sleep mode" and blanks the display if there is no function change, range change or button press for at least one second or turn the rotary switch. When a new...
.... Manual and Autoranging The Meter has both Manual and Autorange modes. • In the Autorange mode, the Meter selects the range with the best resolution. • In the Manual Range mode, you apply a different voltage. 116 Users Manual Battery Saver ("Sleep Mode") The Meter automatically enters "Sleep mode" and blanks the display if there is no function change, range change or button press for at least one second or turn the rotary switch. When a new...
Fluke 116 Users Manual
Page 11
... or Display Hold, the Meter beeps twice, indicating an invalid operation, and the range does not change the range in the following pages show how to the lowest range. To exit Manual Range, press q for at least 1 second or turn the rotary switch. Power-Up Options To select a Power-Up Option, hold down ("Sleep mode"). bEEP is displayed. 2. Disables auto backlight off and when sleep mode is displayed...
... or Display Hold, the Meter beeps twice, indicating an invalid operation, and the range does not change the range in the following pages show how to the lowest range. To exit Manual Range, press q for at least 1 second or turn the rotary switch. Power-Up Options To select a Power-Up Option, hold down ("Sleep mode"). bEEP is displayed. 2. Disables auto backlight off and when sleep mode is displayed...
Fluke 116 Users Manual
Page 12
For maximum accuracy in making resistance measurements, use the Meter's resistance (e) function. 116 Users Manual Measuring Resistance Testing for Continuity XWWarning eeo04f.eps To avoid electric shock, injury, or damage to the Meter, disconnect circuit power and discharge all highvoltage capacitors before testing resistance, continuity, diodes, or capacitance. 10 eeo06f.eps Note The continuity function works best as a fast, convenient method to check for opens and shorts.
For maximum accuracy in making resistance measurements, use the Meter's resistance (e) function. 116 Users Manual Measuring Resistance Testing for Continuity XWWarning eeo04f.eps To avoid electric shock, injury, or damage to the Meter, disconnect circuit power and discharge all highvoltage capacitors before testing resistance, continuity, diodes, or capacitance. 10 eeo06f.eps Note The continuity function works best as a fast, convenient method to check for opens and shorts.
Fluke 116 Users Manual
Page 13
... input applied between the + and COM jacks. Measuring AC and DC Voltage Volts AC Volts DC V True-rms Multimeter Making Basic Measurements Measuring AC and DC Millivolts Millivolts AC Millivolts DC DC eeo03f.eps Using Auto Volts Selection With the function switch in the l position, the Meter measures ac plus dc millivolts. This function also sets the Meter's input...
... input applied between the + and COM jacks. Measuring AC and DC Voltage Volts AC Volts DC V True-rms Multimeter Making Basic Measurements Measuring AC and DC Millivolts Millivolts AC Millivolts DC DC eeo03f.eps Using Auto Volts Selection With the function switch in the l position, the Meter measures ac plus dc millivolts. This function also sets the Meter's input...
Fluke 116 Users Manual
Page 14
Turn heating unit on and record μA measurement. 12 Flame sensor probe Control Module eeo08f.eps To measure flame rectification circuits: 1. Turn the function switch to earth is > 600 V. • Use the proper switch position and range for your measurement. Connect the Meter between the flame sensor probe and the control module. 3. 116 Users Manual Measuring AC and DC Current WWarning To avoid personal injury or damage to the Meter: • Never attempt to make an in-circuit current measurement when the opencircuit potential to $. 2.
Turn heating unit on and record μA measurement. 12 Flame sensor probe Control Module eeo08f.eps To measure flame rectification circuits: 1. Turn the function switch to earth is > 600 V. • Use the proper switch position and range for your measurement. Connect the Meter between the flame sensor probe and the control module. 3. 116 Users Manual Measuring AC and DC Current WWarning To avoid personal injury or damage to the Meter: • Never attempt to make an in-circuit current measurement when the opencircuit potential to $. 2.
Fluke 116 Users Manual
Page 16
... range. Press g to turn the frequency measurement function on the Meter to switch the Meter into sleep mode. This setting is not saved when the Meter is 0 V for a stable reading. Making Low Impedance Capacitance Measurements For making capacitance measurements on cables with ac volts only. 2. In frequency, the bar graph and range annunciator indicate the AC voltage present. 3. edy09f.eps 14 116 Users Manual Measuring Frequency...
... range. Press g to turn the frequency measurement function on the Meter to switch the Meter into sleep mode. This setting is not saved when the Meter is 0 V for a stable reading. Making Low Impedance Capacitance Measurements For making capacitance measurements on cables with ac volts only. 2. In frequency, the bar graph and range annunciator indicate the AC voltage present. 3. edy09f.eps 14 116 Users Manual Measuring Frequency...
Fluke 116 Users Manual
Page 17
... the correct function, AC or DC, selected for compatible current clamps. Refer to measure currents that exceed the rating of the Meter. Forward Bias Single Beep Bad Diode Reverse Bias Bad Diode Open and Shorted eeo07f.eps eeo14f.eps 15 Testing Diodes Good Diode Good ...Diode True-rms Multimeter Making Low Impedance Capacitance Measurements Measuring Current above 600 μA The millivolt and voltage function of the Meter can be used with an optional mV/A output Current Probe to a Fluke catalog or contact your local Fluke representative for your current probe.
... the correct function, AC or DC, selected for compatible current clamps. Refer to measure currents that exceed the rating of the Meter. Forward Bias Single Beep Bad Diode Reverse Bias Bad Diode Open and Shorted eeo07f.eps eeo14f.eps 15 Testing Diodes Good Diode Good ...Diode True-rms Multimeter Making Low Impedance Capacitance Measurements Measuring Current above 600 μA The millivolt and voltage function of the Meter can be used with an optional mV/A output Current Probe to a Fluke catalog or contact your local Fluke representative for your current probe.
Fluke 116 Users Manual
Page 18
The number of the scale. Replacing the Battery aej11f.eps 16 eeo11f.eps 116 Users Manual Using the Bargraph The bar graph is disabled when measuring capacitance and temperature. An input of −30 V turns on the negative sign and the segments up to the middle of segments indicates the measured value and is useful for example (see below), the major...
The number of the scale. Replacing the Battery aej11f.eps 16 eeo11f.eps 116 Users Manual Using the Bargraph The bar graph is disabled when measuring capacitance and temperature. An input of −30 V turns on the negative sign and the segments up to the middle of segments indicates the measured value and is useful for example (see below), the major...
Fluke 116 Users Manual
Page 19
To remove the battery door for battery replacement: 1. Install and tighten battery door screw. Lift the door straight up to install the battery directly into the case, bottom edge first, until it from the case. True-rms Multimeter Cleaning The battery fits inside the battery door, which is then inserted ...17 Remove the battery door screw. 3. Use the finger recess to clean the case top or lens/window. Do not use abrasives, isopropyl alcohol, or solvents to lift the door slightly. 4. Remove the test leads from the Meter before opening the case or battery door. Cleaning...
To remove the battery door for battery replacement: 1. Install and tighten battery door screw. Lift the door straight up to install the battery directly into the case, bottom edge first, until it from the case. True-rms Multimeter Cleaning The battery fits inside the battery door, which is then inserted ...17 Remove the battery door screw. 3. Use the finger recess to clean the case top or lens/window. Do not use abrasives, isopropyl alcohol, or solvents to lift the door slightly. 4. Remove the test leads from the Meter before opening the case or battery door. Cleaning...
Fluke 116 Users Manual
Page 20
116 Users Manual General Specifications Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No... III, Pollution Degree 2 Display Digital: 6,000 counts, updates 4/sec Bar Graph: 33 segments, updates 32/sec Temperature Operating: -10 °C to + 50 °C Storage: -40 °C to 90 %. Extended specifications are available at 0 % to + 60 °C Temperature Coefficient 0.1 x (specified accuracy)/°C (28 °C) Operating Altitude 2,000 meters Battery 9 Volt Alkaline, NEDA ...
116 Users Manual General Specifications Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No... III, Pollution Degree 2 Display Digital: 6,000 counts, updates 4/sec Bar Graph: 33 segments, updates 32/sec Temperature Operating: -10 °C to + 50 °C Storage: -40 °C to 90 %. Extended specifications are available at 0 % to + 60 °C Temperature Coefficient 0.1 x (specified accuracy)/°C (28 °C) Operating Altitude 2,000 meters Battery 9 Volt Alkaline, NEDA ...
Fluke 116 Users Manual
Page 23
... kHz 0.1 % + 2 Notes: [1] All AC ranges except Auto-V LoZ are specified from 1 % to 100% of range are not specified, it is normal for this and other true-rms meters to display nonzero readings when the test leads are disconnected from a circuit or are dc-coupled. [2] Temperature uncertainty (accuracy) does not include the error of ≤3 at 4000...
... kHz 0.1 % + 2 Notes: [1] All AC ranges except Auto-V LoZ are specified from 1 % to 100% of range are not specified, it is normal for this and other true-rms meters to display nonzero readings when the test leads are disconnected from a circuit or are dc-coupled. [2] Temperature uncertainty (accuracy) does not include the error of ≤3 at 4000...