Fluke 115 Support and Manuals

Get Help and Manuals for this Fluke item

View All Support Options Below
Free Fluke 115 manuals!
Problems with Fluke 115?

Ask a Question

Most Recent Fluke 115 Questions

Ohm Scale
ohms reading is wrong
(Posted by piyalr2021 1 year ago)
Where Can I Get Fluke 115 Service Manual
(Posted by stevenedwardmorris 1 year ago)

Fluke 115 Videos

Fluke 115 quick review for electronics applications
Duration: :55
Total Views: 1,813
Fluke 115 comparison to unbranded multimeter part 1
Duration: 9:09
Total Views: 2,722
Fluke 115 TRMS Digital Multimeter
Duration: 1:14
Total Views: 306
[ DJ.Fluke.overmix ] - ] Frick - ??????????? [ - [ 115 ] - HIPHOP
Duration: 2:34
Total Views: 1,078

Popular Fluke 115 Manual Pages

Fluke 115 Digital Multimeter Datasheet - Page 1

... hours typical, without backlight Fluke 115 Multimeter Actual size R N10140 Technical Data Compact true-rms meter for field service technicians The Fluke 115 is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with elapsed time to record signal fluctuations • CAT III 600 V safety rated General specifications Accuracy is the solution for...
Fluke 115 Digital Multimeter Datasheet - Page 2

...volts is ac coupled and ac mV is dc coupled. 2 Frequency is ac coupled, 5 Hz to 5 kHz for ac current.  Fluke Corporation 115 Multimeter Ordering information Fluke-115 Multimeter Included TL75 Test leads, holster, User's manual and 9 V battery (installed). Keeping your world up and running. detects opens or shorts of reading] + [counts]) DC millivolts 600.0 mV 0.1 mV 2.0 % + 3 DC...
Fluke 114,115,117 Manual - Page 3

... and a bar graph. Test Lead Alert XWWarning Personal injury or damage to the Meter can occur if you attempt to IV) based on the magnitude of a potentially hazardous voltage, the Y symbol is unspecified. True-rms Multimeters Introduction The Fluke Model 114, Model 115, and Model 117 are battery-powered, true-rms multimeters (hereafter "the Meter") with a lead in the correct terminals...
Fluke 114,115,117 Manual - Page 4

... leads from Meter before opening the battery door or Meter case. 2 114, 115, and 117 Users Manual Safety Information A "XWWarning" statement identifies hazardous conditions and actions that could cause bodily harm or death. These voltages pose a shock hazard. • Disconnect circuit power and discharge all high-voltage capacitors before testing resistance, continuity, diodes, or capacitance...
Fluke 114,115,117 Manual - Page 5

... voltage N Battery (Low battery when shown on the display.) I Fuse T Double Insulated W Important Information; Refer to measure voltages in hazardous areas. • Avoid working in circuits that could be impaired. • Check the test leads for disposal. 3 Do not use if the readings are high or noisy. • Do not use . True-rms Multimeters Safety Information...
Fluke 114,115,117 Manual - Page 6

... mode. Measured input voltage ≥30 V, or voltage overload condition (OL). X Unsafe voltage. edy02f.eps Model 117 114, 115, & 117 115 & 117 114, 115, & 117 114, 115, & 117 A B C D E 4 Symbol w s R O Y 6 5 4 3 2 1 16 15 VoltAlert 7 14 17 8 9 10 11 12 13 18 Meaning The Meter is a negative value. The Meter function is set to Continuity. 114, 115, and 117 Users Manual Display No.
Fluke 114,115,117 Manual - Page 7

... current 114, 115 & 117 L N Battery low warning. 114, 115, & 117 M 610000 mV Indicates the Meter's range selection. 114, 115, & 117 N (Bar graph) Analog display. 114, 115, & 117 O Auto Volts The Meter is too large for best resolution. 114, 115, & 117 Manual Manual ranging. True-rms Multimeters Display F K Display hold enabled. User sets the Meter's range. 114, 115, & 117...
Fluke 114,115,117 Manual - Page 8

... error. edy01f.eps Model 115 & 117 114, 115, & 117 114, 115, & 117 bAtt CAL Err EEPr Err F11 Err Error Messages Battery must be replaced before the Meter will operate. B Common (return) terminal for all measurements. Internal error. The Meter must be repaired before it will operate. 114, 115, and 117 Users Manual Terminals 1 V A COM 3 10 A FUSED 2 No. The Meter...
Fluke 114,115,117 Manual - Page 11

... turning the Meter on. when removing the test leads, remove the live lead; If you press qwhile in MIN MAX AVG or Display Hold, the Meter beeps twice, indicating an invalid operation and the range does not change the range in the following pages show how to the lowest range. Enables low impedance capacitance measurements. Disables...
Fluke 114,115,117 Manual - Page 14

114, 115, and 117 Users Manual Measuring AC or DC Current (115 & 117) XWWarning To avoid personal injury or damage to the Meter: • Never attempt to make an in-circuit current measurement when the opencircuit potential to earth is >600 V. • Check the Meter's fuse before testing. (See "Testing the Fuse") • Use the proper terminals, switch position, and...
Fluke 114,115,117 Manual - Page 19

...8226; Remove test leads from the Meter before opening the case or battery door. • Use ONLY a fuse with the amperage, interrupt voltage, and speed ratings specified. Replacing the Battery and Fuse XWWarning To avoid shock, injury, or damage to lift the door slightly. 4. Remove the battery door screw. 3. True-rms Multimeters Maintenance Fuse edy11f.eps 17 Install and tighten battery door...
Fluke 114,115,117 Manual - Page 20

..., or solvents to the case top, then install the two screws. Finally, insert the Meter into its holster. 3. Remove the Meter from its holster. Cleaning Wipe the case with an 11 A, 1000 V, FAST fuse having a minimum interrupt rating of 17,000 A. Remove the test leads from its holder and replace it with a damp cloth and mild detergent...
Fluke 114,115,117 Manual - Page 21

... Multimeters General Specifications General Specifications Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No 61010-1-04, UL 6101B (2003) and IEC/EN 61010-1 2nd Edition for A input (115 & 117 only 11 A, 1000 V FAST 17 kA Fuse (Fluke...
Fluke 114,115,117 Manual - Page 22

Accuracy Specifications Function DC millivolts DC Volts Range 600.0 mV 6.000 V 60.00 V 600.0 V Auto-V LoZ[1] True-rms 600...1 kHz 2.0 % + 3 0.001 V 0.01 V 0.1 V 1.0 % + 3 2.0 % + 3 Model 114, 115, 117 114, 115, 117 114, 117 114, 115, 117 114, 115, 117 20 114, 115, and 117 Users Manual Certifications UL, P, CSA, TÜV, ; (N10140), VDE IP Rating (dust and water protection IP42 Table 1....
Fluke 114,115,117 Manual - Page 24

... Specifications (cont.) Function Range Resolution Accuracy ± ([% of Reading] + [Counts]) Model AC Amps Truerms[1] (45 Hz to 500 Hz) 6.000 A 10.00 A[3] 20 A for 30 seconds max., 10 minutes rest min. 0.001 A 0.01 A 1.5 % + 3 115, 117 DC Amps 6.000 A 10.00 A[3] 20 A for this and other true-rms meters to display nonzero readings when the test leads...

Fluke 115 Reviews

Do you have an experience with the Fluke 115 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.

Popular Fluke 115 Search Terms

The following terms are frequently used to search for Fluke 115 support:

Ask a New Question
Use the box below to post a new question about Fluke 115.
Manuals / Documents
Download any of our Fluke 115 manuals for free!

We have the following 2 documents available for the Fluke 115:
  • Fluke 114,115,117 Manual
  • Fluke 115 Digital Multimeter Datasheet
Related Items
View other Fluke Electronics Accessories:

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 115 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke 115 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.