What's The Importance Of The Two Fuses On The Pcb In This Model Of Meter
can I use my meter with out the 3 fuses on the PCB in this model meter
(Posted by mbajukmoses2 6 years ago)

Fluke 177 Videos

Fluke 177 Training
Duration: 5:43
Total Views: 1,632
Evione ElectronicsEpisode 1 Fluke 177 Review
Duration: 15:08
Total Views: 1,517
Multimeter review / buyers guide: Fluke 177 / 179 - Part 1
Duration: 15:08
Total Views: 53,833
Fluke Digital Multimeter Overview - 170, 175, 177, 179 Series
Duration: 4:27
Total Views: 49,371

Popular Fluke 177 Manual Pages

Fluke 73, 77, 175, 177, and 179 Digital Multimeter Datasheet - Page 1

... Feature Max voltage True-rms Temperature Basic dc accuracy Backlight Min/Max/Avg ToolPak meter hanging kit with magnet 73 600 0.3 % 77 1000 0.3 % 175 1000 177 1000 179 179/TPK 1000 1000 0.15 % 0.09 % 0.09 % 0.09 % Opt Opt Opt Included Fluke 73 and 77 Basic autoranging multimeters with TL75 test leads, 9 V battery (installed), and manual. Specifications - 170 Series...
FE 175,177,179 Users Manual - Page 1

Printed in USA. All rights reserved. ® Models 175, 177, 179 True RMS Multimeters Users Manual May 2003 (English) © 2003 Fluke Corporation.
FE 175,177,179 Users Manual - Page 2

... product's specifications, or normal wear and tear of competent jurisdiction, such holding will pay return transportation for repair and return...Fluke assumes no charge, replace or refund the purchase price of a defective product purchased through a Fluke authorized sales outlet and at least ten years from neglect, misuse, contamination, alteration, accident or abnormal conditions of operation...
FE 175,177,179 Users Manual - Page 3

... AC and DC Voltage 6 Measuring Resistance ...6 Measuring Capacitance...6 Testing for Continuity...7 Measuring Temperature (Model 179 Only 7 Testing Diodes ...7 Measuring AC or DC Current 8 Understanding AC Zero Input Behavior of True RMS Meters 8 Measuring Frequency...9 Using the Bar Graph...9 Cleaning ...10 Testing the Fuses...10 Replacing the Battery and Fuses 10 Specifications ...11 i
FE 175,177,179 Users Manual - Page 4

... Meter only as specified in accordance with voltages above 30 V ac rms, 42 V ac peak, or 60 V dc. Meter in this manual or the protection provided by TÜV (Technischer Überwachungs Verein) Product Services ; Read before opening the Meter case or battery door. see manual b Battery (Low battery when shown on the Meter, between the...
FE 175,177,179 Users Manual - Page 5

... is displayed. The Fluke Model 175, Model 177, and Model 179 are designed to protect against transients from the primary supply level (overhead or underground utility service). CAT III meters are batterypowered, true-RMS multimeters (hereafter "the Meter") with a test lead in fixed-equipment installations at : register.fluke.com Models 175, 177 & 179 True RMS Multimeters "Warning" and...
FE 175,177,179 Users Manual - Page 6

...voltage from 1 nF to 600 mV. Note: AC voltage and current AC-coupled, true RMS, up to 1000 V. Common (return) terminal for 30 BA seconds maximum). L.... DC mA from 3.00 mA to 30 kHz. Models 175, 177 & 179 Users Manual Battery Saver ("Sleep Mode") The Meter enters the "... . 1 3 V FUSED 2 4 Item 1 2 3 4 AIK01F.EPS Description Input terminal for AC and DC milliamp ...
FE 175,177,179 Users Manual - Page 7

... units. Replace battery. ...Error Messages Replace the battery immediately. AutoHOLD is interrupted. MIN MAX AVG enabled. Have Meter serviced. Invalid EEPROM data. Invalid calibration data. mVA, Mke, kHz 8 DC, AC 9 b Direct current, alternating current. Unsafe voltage. In MIN MAX AVG mode, MIN MAX AVG recording is enabled. Manual Range The user selects the range. 13 &#177...
FE 175,177,179 Users Manual - Page 8

...in the MIN MAX AVG mode.) Press MIN MAX to toggle the backlight on a rotary switch setting, e.g., to step through the low (MIN), average (AVG), and present readings. To pause... Press HOLD to resume normal operation. lights. ⇒ Press HOLD again to activate Display HOLD. Unstable or noisy readings will not be captured. Models 175, 177 & 179 Users Manual MIN MAX AVG Recording Mode ...
FE 175,177,179 Users Manual - Page 9

...operation. the software version number is turned OFF. R Enables "Smoothing" mode. S Disables automatic 2-minute backlight timeout. (Model 177 and 179 Only) 5 After the highest range, the Meter wraps to increment the range. To exit Manual...To enter the Manual Range mode, press RANGE. Dampens display fluctuations of rapidly changing inputs by digital filtering. In the Manual Range mode, ...
FE 175,177,179 Users Manual - Page 10

... leads to the circuit or device, connect the common (COM) test lead before connecting the live lead before testing resistance, continuity, diodes, or capacitance. Models 175, 177 & 179 Users Manual Making Basic Measurements The figures on the following pages show how to the Meter, disconnect circuit power and discharge all high-voltage capacitors before...
FE 175,177,179 Users Manual - Page 12

... mA + + A CAT CAT AIK08F.EPS 8 Models 175, 177 & 179 Users Manual XW Measuring AC or DC Current Warning To avoid personal injury or damage to the Meter: • Never attempt to make an in series, turn power on the lowest ranges are normal. Understanding AC Zero Input Behavior of True RMS Meters Unlike averaging meters, which...
FE 175,177,179 Users Manual - Page 14

Models 175, 177 & 179 Users Manual Cleaning Wipe the case with a damp cloth and mild detergent. HOLD MINMAX RANGE 440 mA 11 A XW Testing the Fuses Warning To avoid electrical shock or injury, remove the test leads and any input signals before replacing the fuse. Dirt or moisture in the terminals can affect readings. Do not use abrasives or solvents. Test fuses as shown below.
FE 175,177,179 Users Manual - Page 16

Models 175, 177 & 179 Users Manual Function Range 1 Resolution Accuracy ± ( [ % of range. 2. Amps input burden voltage (typical): 400 mA input 2 mV/mA, 10...;F 9999 µF 4 1 nF 0.01 µF 0.1 µF 1 µF 1.2 % + 2 1.2 % + 2 1.2 % + 2 10 % typical AC Amps 5 (True RMS) (45 Hz to 1 kHz) DC mV 600.0 mV 0.1 mV 0.15 % + 2 0.09 % + 2 0.09 % + 2 DC Volts 6.000 V 60.00 V 600...
FE 175,177,179 Users Manual - Page 18

... short circuit. 660 V for 30 seconds maximum 14 Models 175, 177 & 179 Users Manual Function Volts AC Volts DC mV/T Overload Protection 1 1000 V RMS 1000 V RMS 1000 V RMS2 Input Impedance (Nominal) > 10 M&#... Function mA A Overload Protection Fused, 44/100 A, 1000 V FAST Fuse Fused, 11 A, 1000 V FAST Fuse Overload 600 mA overload for 2 minutes maximum 20 A overload for high energy circuits...

Fluke 177 Reviews

Do you have an experience with the Fluke 177 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.

Popular Fluke 177 Search Terms

The following terms are frequently used to search for Fluke 177 support:

Ask a New Question
Use the box below to post a new question about Fluke 177.
Manuals / Documents
Download any of our Fluke 177 manuals for free!

We have the following 2 documents available for the Fluke 177:
  • FE 175,177,179 Users Manual
  • Fluke 73, 77, 175, 177, and 179 Digital Multimeter Datasheet
Related Items
View other Fluke Electronics Accessories:

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 177 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke 177 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.